• Title/Summary/Keyword: Plastic adhesion

Search Result 213, Processing Time 0.032 seconds

Surface Modification by Atmospheric Pressure DBDs Plasma: Application to Electroless Ni Plating on ABS Plates

  • Song, Hoshik;Choi, Jin Moon;Kim, Tae Wan
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.3
    • /
    • pp.133-138
    • /
    • 2013
  • Acrylonitrile-butadiene-styrene (ABS) plastic is a polymer material extensively used in electrical and electronic applications. Nickel (Ni) thin film was deposited on ABS by electroless plating, after its surface was treated and modified with atmospheric plasma generated by means of dielectric barrier discharges (DBDs) in air. The method in this study was developed as a pre-treatment for electroless plating using DBDs, and is a dry process featuring fewer processing steps and more environmentally friendliness than the chemical method. After ABS surfaces were modified, surface morphologies were observed using a scanning electron microscope (SEM) to check for any physical changes of the surfaces. Cross-sectional SEM images were taken to observe the binding characteristics between metallic films and ABS after metal plating. According to the SEM images, the depths of ABS by plasma are shallow compared to those modified by chemically treatment. The static contact angles were measured with deionized (DI) water droplets on the modified surfaces in order to observe for any changes in chemical activities and wettability. The surfaces modified by plasma showed smaller contact angles, and their modified states lasted longer than those modified by chemical etching. Adhesion strengths were measured using 3M tape (3M 810D standard) and by 90° peel-off tests. The peel-off test revealed the stronger adhesion of the Ni films on the plasma-modified surfaces than on the chemically modified surfaces. Thermal shock test was performed by changing the temperature drastically to see if any detachment of Ni film from ABS would occur due to the differences in thermal expansion coefficients between them. Only for the plasma-treated samples showed no separation of the Ni films from the ABS surfaces in tests. The adhesion strengths of metallic films on the ABS processed by the method developed in this study are better than those of the chemically processed films.

Long term results in the unilateral cleft lip repair by Mulliken's method (Mulliken 방법을 이용한 일측성 구순열의 장기 추적 결과)

  • Kim, Seok-Kwun;Moon, In-Sun;Lee, Chang-Ho;Heo, Jung;Kwon, Yong-Seok;Lee, Keun-Cheol
    • Archives of Plastic Surgery
    • /
    • v.36 no.2
    • /
    • pp.174-182
    • /
    • 2009
  • Purpose: The Mulliken's method is a one of the very excellent technique to correction of the unilateral cleft lip. It could decrease the need of additional operation and second operation by the early simultaneous correction of unilateral cleft lip and nasal deformity, at a time. Numerous procedures were advocated for the correction of nasal deformity, but with general dissatisfaction of the results, it became obvious that no one procedure is the ideal one. The authors have been operating on unilateral cleft lip by Mulliken's method and long term follow - up of postoperative result was evaluated. Methods: The authors have done long term follow - up of result in the 75 cases unilateral cleft lip patient, during 1 ~ 7 years. That was repaired by simultaneous correction of cleft lip and nasal deformity by Mulliken's method at the period from June, 1997 to December, 2007. The patients were unilateral complete cleft lip 39 cases, unilateral incomplete cleft lip 36 cases. In the severe complete cleft lip cases, lip adhesion operation was done before definite operation. The mean age of unilateral cleft lip operation was 3.2 months. Five anthropometric parameters, which were upper lip, cutaneous lip and vermilion mucosa height, nasal tip protrusion, columella length were measured by Sliding Vernier Caliper. The anthropometric analysis was performed preoperative and postoperative at 6 months, 3, 5 and 7 years and the results were com pared with those of age - matched, normal children. T - tests were used to analyze the differences between the measurements. Results: Long - term postoperative results were evaluated by anthropometrically. Most patients showed adequate growth of upper lip height, vermilion mucosa height and columella length. But nasal tip protrusion was relatively short compare with normal value. Incomplete cleft lip group was nearly normal growth results than complete cleft lip group. Conclusion: In conclusion, we could make harmonious Cupid's bow, natural philtrum and lip, appropriate nasal shape by Mulliken's method. But nasal tip protrusion was under the normal values on complete and incomplete group. And incomplete group was more good results than complete group. We have experienced repair of cleft lip by Mulliken's method with 75 cases of unilateral cleft lip patients and conclude that it was very useful and good method.

Characterization of Concrete Composites with Mixed Plastic Waste Aggregates (복합 폐플라스틱 골재 치환 콘크리트의 기초 물성 평가)

  • Lee, Jun;Kim, Kyung-Min;Cho, Young-Keun;Kim, Ho-Kyu;Kim, Young-Uk
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.3
    • /
    • pp.317-324
    • /
    • 2020
  • Plastic wastes generated from domestic waste are separated by mixed discharge with foreign substances, and the cost of the separation and screening process increases, so recycling is relatively low. In this study, as a fundamental study for recycling mixed plastic wastes generated from domestic waste into concrete aggregates, changes in concrete properties according to the plastic waste types and the substitution rate were evaluated experimentally. The mixed plastic waste aggregate(MPWA) was found to have a lower density and a higher absorption rate compared to the coarse aggregate with good particle size distribution. On the other hand, the single plastic waste aggregate(SPWA) was composed of particles of uniform size, and both the density and the absorption rate were lower than that of the fin e aggregate. It was found that the MPWA substitution concrete did not cause a material separation phenomenon due to a relatively good particle size distribution even with the largest amount of plastic waste substitution, and the amount of air flow increased little. The compressive strength and flexural strength of the PWA substitution concrete decreased as the amount of substitution of the PWA increased due to the low strength of the PWA, the suppression of the cement hydration reaction due to hydrophobicity, and the low adhesion between the PWA and the cement paste. It was found that the degree of deterioration in compressive strength and flexural strength of concrete substituted with MPWA having good particle size distribution was relatively small.

Quantitative analysis of mutans streptococci adhesion to various orthodontic bracket materials in vivo (다양한 교정용 브라켓 원재료에 부착하는 mutans streptococci 양의 비교분석)

  • Yu, Jin-Kyoung;Ahn, Sug-Joon;Lee, Shin-Jae;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.39 no.2
    • /
    • pp.105-111
    • /
    • 2009
  • Objective: To estimate the effects of bracket material type on enamel decalcification during orthodontic treatment, this study analyzed the adhesion level of mutans streptococci (MS) to orthodontic bracket materials in vivo. Methods: Three different types of orthodontic bracket materials were used: stainless steel, monocrystalline sapphire, and polycrystalline alumina. A balanced complete block design was used to exclude the effect of positional variation of bracket materials in the oral cavity. Three types of plastic individual trays were made and one subject placed the tray in the mouth for 12 hours. Then, the attached bacteria were isolated and incubated on a mitis salivarius media containing bacitracin for 48 hours. Finally, the number of colony forming units of MS was counted. The experiments were independently performed 5 times with each of the 3 trays, resulting in a total of 15 times. Mixed model ANOVA was used to compare the adhesion amount of MS. Results: There was no difference in colony forming units among the bracket materials irrespective of jaw and tooth position. Conclusions: This study suggested that the result of quantitative analysis of MS adhesion to various orthodontic bracket materials in vivo may differ from that of the condition in vitro.

A Study on the Mechanical and Physical Properties of Sawdustboard combined with Plastic Chip (플라스틱칩 결체(結締) 톱밥보드의 기계적(機械的) 및 물리적(物理的) 성질(性質)에 관(關)한 연구(硏究))

  • Lee, Phil-Woo;Suh, Jin-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.44-55
    • /
    • 1987
  • In order to study the effect of sawdustboard combined with plastic chips, 0.5mm($T_1$), 1mm($T_2$), 1.4mm($T_3$) thick nylon fiber. polypropylene rope fiber(RP), and 0.23mm thick moth-proof polypropylene net fiber(NP) were cut into 0.5, 1, 2cm long plastic chips. Thereafter, sawdustboard combined with plastic chips prepared as the above and plastic non-combined sawdustboard(control) were manufactured into 3 types of one-, two-, and three layer with 5 or 10% combination level. By the discussions and results at this study, the significant conclusions of mechanical and physical properties were summarized as follows: 1. The MORs were shown in the order of 3 layer> 2 layer> 1 layer among plastic non-combined boards, and $T_3$ < $T_2$ < $T_1$ < RP (NP(5%) < NP(l0%) among plastic combined boards. In 2cm long plastic chip in 1 layer board, the highest strength through all the composition was recognized. 1 layer board showing the lower strength with 0.5cm plastic chip rendered to the bending strength improvement by 2 or 3 layer board composition. On the other hand, 2 or 3 layer combined with 1, 2cm long polypropylene net fiber chips incurred MOR's conspicuous decrease requiring optimum plastic chip combined level and consideration to combined type. 2. MOE in plastic non-combined 3 layer board exhibited sandwich construction effect by higher resin content application to surface layer in the order of 3layer>1layer>2layer with the highest stiffness of the board combined with polypropylene chip, while nylon chip-combined board had little difference from plastic non-combined board. In relevant to length and layer effect, 3 layer board combined with the 0.5cm long polypropylene net fiber chip in 5% and 10% combined level presented 34-43% and 44-76% stiffness increase against plastic non-combined board(control), respectively. Moreover, in 1 layer board, 30% stiffness increase with 10% against 5% combined level in the 1 and 2cm long polypropylene net fiber chip was obtained. 3. Stress at proportional limit(Spl) showing the fiber relationship (r: 0.81-0.97) between MOR presented in the order of 1 layer<2 layer<3 layer in plastic non-combined board. Correspondingly, combined effect by layer and plastic chip length was similar to MOR's. 4. Differently from previous properties(MOR, MOE, Spl). work to maximum load(Wml) of 2 layer board approached to that of 3 layer board. Conforming the above phenomenon. 2 layer combined with 0.5cm long polypropylene net fiber chip kept the greater work than 1 layer. The polypropylene combined board superior to nylon -and plastic non - combined board seemed to have greater anti - failing capacity. 5. Internal bond strength(IB), in contrast to MOR's tendency. showed in the order of T1

  • PDF

Oxygen Barrier Coating with Carbon Interlayer on Polypropylene

  • Kim, Seong-Jin;Song, Eun-Gyeong;Jo, Gyeong-Sik;Yun, Tae-Gyeong;Mun, Myeong-Un;Lee, Gwang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.210-210
    • /
    • 2012
  • Gas barrier coating from dense thin film deposition has been one of the important applications such as food-packaging and organic display. Especially for food-packaging, plastic container has been widely used due to its low price and high through-put in mass production. However, the plastic container with low surface energy like polypropylene (PP) has been limited to apply gas barrier coating. That is because a gas barrier coating could not adhere to PP due to its too low surface energy and high porosity of PP. In this research, we applied carbon coating consisting of Si and O as an interlayer between silicon oxide (SiOx) and PP. A carbon layer was found to provide better adhesion, which was experimentally proved by oxygen transmission rate (OTR) and SEM images. However, we also found that there is a limitation in the maximum thickness of a carbon layer and SiOx film due to their high stress level. For this conflict, we obtain the optimal thickness of a carbon layer and SiOx film showing optimal gas barrier property.

  • PDF

A Study on identification and improvement of adhesive quality using adhesive theory at micro/nano scale contact (응착이론을 이용한 마이크로/나노스케일 접촉에서의 응착특성 규명 및 개선에 관한 연구)

  • Kim, Gyu-Sung;Yoon, Jun-Ho
    • 전자공학회논문지 IE
    • /
    • v.44 no.3
    • /
    • pp.42-50
    • /
    • 2007
  • In this paper, elastic and plastic adhesion index was very important in deciding adhesive characteristics and varying elastic and plastic index, dimensionless load and pull-off force were analyzed and simulated. Finally, using AFM, experimental surface roughness parameters of substrates and pull-off force between tip and substrates were produced. Using these values, pull-off forces were calculated and were compared with experimental pull-off forces. Through simulation and experiment, it was found that interaction of asperity also had very important influence on adhesive contact.

SURGICAL TREATMENT OF LARGE CYST ON THE MANDIBLE BY USING SAGGITAL SPLIT RAMUS OSTEOTOMY (하악골에 발생한 거대 낭종에서 하악지 시상분할골절단술을 이용한 외과적 치료)

  • Park, Hong-Ju;Ryu, Jae-Young;Kook, Min-Suk;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.1
    • /
    • pp.100-107
    • /
    • 2008
  • First of all a good surgical access is considered among various approach methods to the cystic lesion. A poor surgical access can lead to a failure of the whole treatment. A sagittal split ramus osteotomy (SSRO) on the large cyst occurring in the mandibular ramus lets us not only reduce operation time, but can additionally contribute to a good visual field. In addition, a merit exists that it lets this operating method provide soft tissue adhesion for proximal and distal segment and decrease post operative necrosis. We experienced three cases of a large cyst on the mandibular angle and ramus. By employing a sagittal splitting of the mandible, it provided good surgical access and operation results without recurrence during a follow-up period. The surgical technique described may be helpful in treating similar large cysts.

The Protective Effect of Prostaglandin E1 Against Ischemia-reperfusion Injury of Musculocutaneous Flaps (백서 복직근피판에 있어 허혈-재혈류 손상에 미치는 Prostaglandin E1의 예방효과)

  • Hong, Joon Pio;Chung, Yoon Kyu;Chung, Soon-Hee
    • Archives of Reconstructive Microsurgery
    • /
    • v.9 no.2
    • /
    • pp.190-198
    • /
    • 2000
  • 본 연구는 백서 복직근피판에 있어 허혈-재혈류 손상에 미치는 prostaglandin E1(PGE-1)의 예방효과를 분석 실험하였으며, 그 기전으로 내피세포의 intercellular adhesion molecule-1(ICAM-1)이 down regulation 됨을 확인하였다. 기존의 PGE-1은 혈관 확장 및 혈소판 응고 저하 등의 기전으로 피판 이식술 후 주로 사용하였으나, 허혈-재혈류 손상 시에 PGE-1 역할에 대한 연구는 잘 알려진바 없다. 허혈-재혈류 손상에 대한 기전은 현재 여러 가설로 설명되고 있으나, 최근 내피 세포와 백혈구의 역할이 주목을 받고 있다. 장시간 허혈 상태의 피판은 재혈류시 백혈구가 내피세포에 접착함으로써 직간접적인 경로로 독소를 생성하며, 결국 내피세포 및 주변조직의 괴사로 이어진다. 본 연구는 면역조직학 염색을 통한 내피세포의 ICAM-1 발현 억제와 그로 인한 백혈구의 내피세포 접착 억제를 그 기전으로 볼 수 있었으며, PGE-1을 술 중 투여함으로써 피판의 생존율을 향상시킬 수 있었다.

  • PDF

CLINICAL STUDY OF TEMPOROMANDIBULAR JOINT OPEN SURGERY (측두하악관절 관혈적 수술에 관한 임상적 연구)

  • Shim, Cheong-Hwan;Kim, Young-Kyun;Yun, Pil-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.1
    • /
    • pp.55-65
    • /
    • 2005
  • Most patients with temporomandibular disorder can be treated conservatively. However, open TMJ surgery can be needed in some patients. We analysed the patients with TMD which open surgery has performed since 1998. Open surgery was carried out in 8 patients. Age ranged from 22 to 61 years, with a mean of 42.8years. All patients were male. Final diagnosis was obtained based upon clinical, radiographic and operative finding as follows; habitual luxation, bony ankylosis, traumatic arthritis, disc displacement with destructive change, disc displacement and adhesion. Etiologic factors included trauma(4), infection(2), and unknown(2). Open surgery included arthroplasty with either of condylectomy, eminectomy, meniscoplasty, capsurrohaphy. All patients were recovered uneventfully without severe complications. Some mouth opening limitation and mouth opening deviation remained. Postoperative aggressive physical therapy and careful follow up were performed. In conclusion, open TMJ surgery must be considered in organic disease such as ankylosis, tumor and TMD without favorable recovery after long-term conservative therapy.