• Title/Summary/Keyword: Plastic Optical Fiber

Search Result 135, Processing Time 0.026 seconds

Monitoring of Retrofitted Reinforced Concrete Beams with Hybrid Fiber Reinforced Polymer (광섬유 센서를 이용한 복합 섬유 재료로 보강된 철근 콘크리트 보의 모니터링)

  • 이옥기;신영수;김기수;김종우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.509-514
    • /
    • 2001
  • The Fibre-optic Bragg grating (FBG) sensor is broadly accepted as a structural health monitoring device for Fibre reinforced plastic (FRP) materials by either embedding into or bonding onto the structures. The accuracy of the strain measured by using the FBG sensor is highly dependent on the bonding characteristics among the bare optical fibre, protective coating, adhesive layer and host material. In general, the signal extracted from the embedded FBG sensor should reflect the straining condition of the host structure. This paper presents a theoretical model to evaluate the differential strains between the bare fibre and host material with different adhesive thickness and modulus of the protective coating of the embedded FBG sensor.

  • PDF

Application of Shearography for Nondestructive Evaluation of Internal Defects in CFRP (CFRP에 내재된 결함의 비파괴 평가를 위한 Shearography기법 적용)

  • 최상우;이준현
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2002.06a
    • /
    • pp.245-251
    • /
    • 2002
  • Electronic Speckle Pattern Interferometry(ESPI) is one of optical technique to measure displacement precisely, uses CCD camera to show result image in real time. General ESPI system measures in-plane or out-of-plane displacement. Shearography is one of electronic speckle pattern interferometric methods which allow full-field observation of surface displacement derivatives and it is robust in vibration. The shearography provides non-contacting technique of evaluating defects nondestructively In this study, the shearography was used to evaluate defects in Carbon Fiber Reinforced Plastic(CFRP). Various sizes of artificial defects were embedded in various depths of woven CFRP plate. Effects due to the variation of size and depth of defects were evaluated in this study.

  • PDF

A Study on Bending Vibration of Laminated Rotating Disc (복합재료 회전체의 휨진동에 관한 연구)

  • Park, Sung-Jin;LEE, Seung-Hyeon
    • Journal of Urban Science
    • /
    • v.10 no.1
    • /
    • pp.11-20
    • /
    • 2021
  • In this study, the vibration characteristics were theoretically analyzed by modeling a free isotropic rotating disk with an outer periphery with a fixed inner periphery, paying attention to disks used as storage devices for information devices, especially magnetic disks, magneto-optical disks, and compact disks in which the head and disk are non-contact. Iluminate with Composite materials represented by fiber-reinforced plastics (FRP) have high specific strength (strength/density) and specific stiffness (narrowness/density). It is used in the elements, and its use is rapidly expanding. Under this circumstance, the disk currently manufactured using an isotropic material made of various plastic materials such as aluminum or polycarbonate as a base material is an extremely anisotropic material made of a composite material, and the circumferential stiffness of the disk is made of reinforcing fibers in the circumferential direction. It is modeled as an anisotropic rotating disk with increased, and its influence on the vibration characteristics is revealed.

Fiber-optic Goniometer to Measure Knee Joint Angle for the Diagnosis of Gait Disturbance (보행장애 진단을 위한 무릎관절 각도 측정용 광섬유 각도센서)

  • Kim, S.G.;Shin, S.H.;Jeon, D.;Hong, S.H.;Sim, H.I.;Jang, K.W.;Yoo, W.J.;Lee, B.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.1009-1013
    • /
    • 2013
  • In this study, we developed a fiber-optic goniometer for the continuous measurement of knee joint angle which provides important medical information on Alzheimer's disease. The fiber-optic goniometer is composed of a light-emitting diode (LED), a plastic optical fiber (POF), and a voltage output photodiode (PD). As a sensing part of the fiber-optic goniometer, a unclad fiber with regular intervals of 1 mm was fabricated to improve efficiency of bending loss according to the angle variation of knee joint. The emitting light with a center wavelength of 470 nm from a LED is guided by a POF to the PD, the transmitted light is then attenuated by the bending loss inside the bent POF. The intensity variation of the light transmitted from the POF gives rise to a change in output voltage in the fiber-optic goniometer. Therefore, we measured the real-time output voltage of the proposed fiber-optic goniometer using the unclad fiber according to the knee joint angle. Through the repeated experiments, the fiber-optic goniometer shows that it has a reversibility and a wide measurable angle range.

A Study on AE Signal Analysis of Composite Materials Using Matrix Piezo Electric Sensor (매트릭스형 피에조센서를 이용한 복합재료 AE신호 분석에 관한 연구)

  • Yu, Yeun-Ho;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • As fiber reinforced composite materials are widely used in aircraft, space structures and robot arms, the study on non-destructive testing methods has become an important research area for improving their reliability and safety. AE (acoustic emission) can evaluate the defects by detecting the emitting strain energy when elastic waves are generated by the initiation and growth of crack, plastic deformation, fiber breakage, matrix cleavage, or delamination. In the paper, AE signals generated under uniaxial tension were measured and analyzed using the $8{\times}8$ matrix piezo electric sensor. The electronic circuit to control the transmitting distance of AE signals was designed and constructed. The optical data storage system was also designed to store the AE signal of 64channels using LED (light emitting diode) elements. From the tests, it was shown that the source location and propagation path of AE signals in composite materials could be detected effectively by the $8{\times}8$ matrix piezo electric sensor.

A study on strength reinforcement of one-sided reinforced hybrid laminates made of 22MnB5 and carbon fiber reinforced plastics (22MnB5 / 탄소섬유 강화 플라스틱으로 제작된 단면 보강 하이브리드 적층판의 강도 보강에 관한 연구)

  • Lee, Hwan-Ju;Jeon, Young-Jun;Kim, Dong-Earn
    • Design & Manufacturing
    • /
    • v.16 no.2
    • /
    • pp.1-6
    • /
    • 2022
  • As environmental regulations are strengthened, automobile manufacturers continuously research lightweight structures based on carbon fiber reinforced plastic (CFRP). However, it is difficult to see the effect of strength reinforcement when using a single CFRP material. To improve this, a hybrid laminate in which CFRP is mixed with the existing body structural steel was proposed. In this paper, CFRP patch reinforcement is applied to each compression/tensile action surface of a 22MnB5 metal sheet, and it was evaluated through a 3-point bending experiment. Progressive failure was observed in similar deflection on bending deformation to each one-sided reinforced specimen. After progressive failure, the tensile reinforced specimen was confirmed to separate the damaged CFRP patch and 22MnB5 sheet from the center of the flexure. The compression reinforced specimen didn't separate that CFRP patch and 22MnB5, and the strength reinforcement behavior was confirmed. In the compression reinforced specimen, damaged CFRP patches were observed at the center of flexure during bending deformation. As a result of checking the specimen of the compression reinforcement specimen with an optical microscope, It is confirmed that the damaged CFRP patch and the reinforced CFRP patch overlapped, resulting in a concentrated load. Through the experimental results, the 22MnB5 strength reinforcement characteristics according to the reinforcement position of the CFRP patch were confirmed.

Visualization of Epidermis and Dermal Cells in ex vivo Human Skin Using the Confocal and Two-photon Microscopy

  • Choi, Sang-Hoon;Kim, Wi-Han;Lee, Yong-Joong;Lee, Ho;Lee, Weon-Ju;Yang, Jung-Dug;Shim, Jong-Won;Kim, Jin-Woong
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.61-67
    • /
    • 2011
  • The confocal laser scanning microscopy and two-photon microscopy was implemented based on a single laser source and an objective lens. We imaged and compared the morphology of identical sites of ex vivo human skin using both microscopes. The back-scattering emission from the sample provided the contrast for the confocal microscopy. The intrinsic autofluorescence and the second harmonic generation were used as the luminescence source for the two-photon microscopy. The wavelength of the Ti:Sapphire laser was tuned at 710 nm, which corresponds to the excitation peak of NADH and FAD in skin tissue. The various cell layers in the epidermis and the papillary dermis were clearly distinguished by both imaging modalities. The two-photon microscopy more clearly visualized the intercellular region and the nucleus of the cell compared to the confocal microscopy. The fibrous structures in the dermis were more clearly resolved by the confocal microscopy. Numerous cells in papillary dermal layer, as deep as $100\;{\mu}m$, were observed in both CLSM and two-photon microscopy. While most previous studies focused on fibrous structure imaging (collagen and elastin fiber) in the dermis, we demonstrated that the combined imaging with the CLSM and two-photon microscopy can be applied for the non-invasive study of the population, distribution and metabolism of papillary dermal cells in skin.

QUICK DETERMINATION OF MEAT COLOR, METMYOGLOBIN FORMATION AND LIPID OXIDATION IN BEEF, PORK AND CHICKEN BY NEAR-INFRARED SPECTROSCOPY

  • Mitsumoto, Mitsuru;Sasaki, Keisuke;Murakami, Hitoshi
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1259-1259
    • /
    • 2001
  • Meat becomes brown and rancid during storage in the refrigerator and display in the case. Color changes, metmyoglobin formation and lipid oxidation are the important problems in the transportation / distribution of meat and retail display. The freshness of meat is determined by the sense of vision and smell. Since conventional method determining lipid oxidation is time consuming and destructive (it needs to homogenize meat with reagents, filtrate, time for reaction and read optical density using spectroscopy), more rapid and nondestructive technical tools are desired. The objective of this work was to evaluate near-infrared spectroscopy as an analytical tool for determining meat color, metmyoglobin formation and lipid oxidation. in beef, pork and chicken. Semitendinosus and longissimus thoracis muscles from six beef steers, biceps femoris and longissimus thoracis muscles from twelve LWD crossbred pigs, and superficial pectoral muscles from twenty-four broilers were used. About a 5-cm diameter and 1-cm thick sample (20.0g) was cut from the muscle and placed on plastic foam, over-wrapped with PVC film, and displayed under flourescent lights at 4 degrees C. during 10 days for beef and pork or 4 days for chicken. The spectra was measured by NIR systems Model 5500 Spectrophotometer using fiber optic scan at range of 400 - 1100 nm. Data were recorded at 2 nm intervals and 10 scans / 10 sec were averaged for every sample. Data obtained were saved as log 1/Re, where Re is the reflectance energy, and then mathematically transformed to second derivatives to reduce effects of differences in particle size. $L^{*}$, $a^{*}$ and $b^{*}$, and metmyoglobin formation were determined by conventional spectrophotometer using the integrating sphere unit. 2-Thiobarbituric acid reactive substances (TBARS) were measured for lipid oxidation. A multiple linear regression was used to find the equation which would best fit the data. The number of wavelengths used in the equation was selected based on the fewer number compared to the increasing multiple correlation and Decreasing standard error. (omitted)

  • PDF

Embedded System Design of Automotive Media Server Platform with the MOST Interface (MOST 인터페이스를 갖는 차량용 미디어 서버 플랫폼에 대한 임베디드 시스템 설계)

  • Kwak, Jae-Min;Park, Pu-Sik
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.3
    • /
    • pp.262-267
    • /
    • 2006
  • For growing need for the multimedia application in the vehicles, the MOST protocol has been focused on. The MOST protocol supports three kinds of communication modes; short control message, asynchronous packets, and reserved synchronous stream data. Because of a variety of transportation, the MOST is suitable for various applications in vehicle environment. In this paper, we implemented embedded system which is MOST-enabled AMS platform and tested the network communication operation through the control port and the synchronous channel of the source port. We implemented the prototype platforms which communicate each other on the MOST's POF network. Moreover we implemented the DivX decoder attached AMS platform and verified the operation by transferring the video stream and the control messages through the MOST network.

  • PDF