• 제목/요약/키워드: Plasma test

검색결과 1,363건 처리시간 0.021초

대기오염 물질 저감을 위한 저온 플라즈마 반응공정의 특성 (Characteristics of Non-Thermal Plasma Process for Air Pollution Control)

  • 송영훈;신동남;신완호;김관태;최연석;최영석;이원남;김석준
    • 한국대기환경학회지
    • /
    • 제16권3호
    • /
    • pp.247-256
    • /
    • 2000
  • Basic characteristics of non-thermal plasma process to remove C2H4 and NO have been experimentally investigated with a packed-bed type reactor and an ac power supply. The performance of the non-thermal plasma generated by ac power supply was compared with that of a wire-plate type reactor equipped with a pulsed power supply. The result shows that the non-thermal plasma can be effectively generated with an AC power supply that can be easily fabricated with conventional techniques. In order to understand the basic reaction mechanisms of the non-thermal plasma process, parametric tests for different carrier gases(air and nitrogen) and for different reaction pathways have been performed. The test results show that O3 generated by non-thermal plasma plays an dominant role to oxidize C2H4 and NO over N and O radicals when these pollutant gases are carried by dry air under room temperature condition. Experimental observations, however, indicate that N and O radicals can significantly affect on the removal process of the pollutant gases under certain conditions.

  • PDF

플라즈마 표면처리에 의한 Silk/PLA 바이오복합재료의 계면접착 (Interfacial Adhesion of Silk/PLA Biocomposites by Plasma Surface Treatment)

  • 추보영;권미연;이승구;조동환;박원호;한성옥
    • 접착 및 계면
    • /
    • 제5권4호
    • /
    • pp.9-16
    • /
    • 2004
  • 견섬유와 폴리라틱산(PLA) 사이의 계면접착 특성을 향상시키기 위하여 천연섬유 표면을 아르곤과 에틸렌 플라즈마로 각각 처리하였다. 플라즈마 표면처리 후, 견섬유의 표면 모폴로지와 접착이 크게 변화하였다. 다음의 여러 플라즈마 처리조건이 본 연구에 사용되었다: 10, 25, 50 그리고 150 W의 전력, 1, 3, 5, 7 그리고 10분의 처리시간 및 10과 50 sccm의 가스흐름속도, 플라즈마 처리된 Silk/PLA 바이오복합재료의 계면전단강도는 단섬유 micro-droplet debonding 시험방법으로 측정하였다. 결과는 Silk/PLA 바이오복합재료의 계면접착을 향상시키기 위한 최적의 플라즈마 처리 조건을 제공하여 주었다.

  • PDF

삼상 교류 플라즈마 발생의 안정화 (Stabilization of Plasma in a Three-Phase AC Plasma Generator)

  • 이경호;김광수;이홍식;임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.209-211
    • /
    • 2002
  • A simple-structured thermal plasma generator for waste gas treatment has been studied. The thermal plasma technology applied to waste treatment has undoubtedly gained high importance owing to its outstanding properties such as flexibility, compact reactor, and clean treatment. Moreover, the thermal plasma generated by ac power has some additional advantages such as simple electrode system and easy maintenance. A prototype 200kW class plasma generator with specifications of 10-30m/sec gas velocity and 3000-5000K temperature on the center just outside of the nozzle has been designed and tested. Case studies on heat transfer, heat flow, velocity distribution, and temperature distribution using a commercial simulation package show lots of flexibility in design. The experimental results from theprototype generator show that the ac thermal plasma is easily controlled by working gas flow once it is ignited. A stabilization condition is discussed with the data from monitoring arc voltage drops with respect to gas flow rate during the test.

  • PDF

Research of aluminum nitride water load for the 4.6 GHz 500 kW LHCD system of the CFETR

  • Dingzhen Li;Liyuan Zhang;Lianmin Zhao;Fukun Liu;Min Cheng;Huaichuan Hu;Taian Zhou
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3126-3132
    • /
    • 2023
  • To meet the increasing heating needs of the China Fusion Experimental Tokamak Reactor (CFETR), the output power in each Lower Hybrid Current Drive (LHCD) transmission line should be increased from 250 kW to 500 kW. Therefore, a new high-power water load must be developed for the 4.6 GHz 500 kW LHCD system. This paper aims to report the most recent research progress of the water load: aluminum nitride (AlN) ceramic is used as the media material to isolate the water and vacuum, and the radio frequency (RF) simulation results show that the return loss of the water load is less than -25dB at 4.6 GHz over a wide temperature range. Under 500 kW continuous wave (CW) operation, the maximum temperatures of the ceramic and water are separately 67 ℃ and 62 ℃, resulting in thermal deformation of the ceramic of approximately 0.003 mm. Moreover, the AlN water load was tested on the 4.6 GHz 250 kW high-power test bench and found to work well with low reflected power.

Simulations for the cesium dynamics of the RF-driven prototype ion source for CRAFT N-NBI

  • Yalong Yang;Yong Wu;Lizhen Liang;Jianglong Wei;Rui Zhang;Yahong Xie;Wei Liu;Chundong Hu
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1145-1152
    • /
    • 2024
  • To realize an initial objective of the negative ion-based neutral beam injection (N-NBI) at the Comprehensive Research Facility for Fusion Technology (CRAFT) test facility, which targets an H0 beam power of 2 MW at an energy of 200-400 keV and a pulse duration of 100 s, it is crucial to study the cesium dynamics of the negative ion source. Here a numerical simulation program CSFC3D is developed and applied to simulate the distribution and time dynamics of cesium during short pulses. The calculations show that most of the cesium on the plasma grid (PG) area originates from the release of cesium that is accumulated within the ion source in the plasma phase. Increasing the wall temperature reduces the loss of cesium on the wall of the ion source. Furthermore, the thickness of the cesium monolayer is directly influenced by the PG temperature. Both simulated and experimental results demonstrate that maintaining the PG temperature between 180 ℃ and 200 ℃ is essential for enhancing the performance of the ion source and optimizing the cesium behavior.

이온 질화층이 TiN 박막의 밀착성에 미치는 영향 (The Adhesion of TiN Coatings on Plasma-nitrided Steel)

  • 고광만;김홍우;김문일
    • 열처리공학회지
    • /
    • 제4권4호
    • /
    • pp.1-14
    • /
    • 1991
  • In PECVD(Plasma-Enhanced Chemical Vapor Deposition) process, titanium nitride is thin and its adhesion is poor for the protective coatings. Therefore it has been studied that intermediate layer forms between substrate and TiN thin film. Using R.F. plasma nitriding, nitride layer was first formed, then TiN thin film coated by PECVD. The chemical composition of the coatings has been characterized using AES, EDS and their crystallographic structure by means of XRD. Mechanical properties such as microhardness and film adhesion have also been determined by vickers hardness test, scratch test and indentation test. As a result, there was no difference in chemical composition and structure between the TiN deposition only and the composite of TiN deposition on nitrided steel. It was found that nitrided substrate increased the hardness of TiN coatings and was beneficial in preventing the plastic deformation in the substrate. Therefore the effective load bearing capacity of the TiN coatings on nitrided steel was increased and their adhesion was improved as well. According to the results of this study, the processes that lead to the formation of composite layers characterized by good working properties, i.e., high microhardness, adhesion and resistance to deformation.

  • PDF

지르코니아 /NiCrAlY 계 플라즈마 용사피막의 고온 파괴거동에 관한 연구 (A Study on High Temperature Fracture Behavior of Plasma Sprayed Zirconia/ NiCrAlY Coating System)

  • 김연직;임재규
    • 대한기계학회논문집A
    • /
    • 제20권10호
    • /
    • pp.3234-3242
    • /
    • 1996
  • This paper describes experimental results of modified small punch( MSP) test conducted to evaluate the fracure characteristics and mechanical properties of plasma sparayed zirconia ($ZrO_2$ stabilized with 8wt. % $Y_20_3$ : YSZ) NiCrAlY composite. The mixing ratios of YSZ/NiCrAlY were 0/100, 25/75, 50/50, 100/0 v.%. Test temperatures ranged from 293K to 1473K. This study is directed at development of thermal barrrier coating(TBC) system with superior heat resistance and mechanical properties. The microstructure and fracture process of the composite were examined by SEM and AE method. The mechanical properties of 100% YSZ were nearly independent of the temperatures tested in this study. In contrast, the NiCrAlY-containing composites showed a significant decrease of the mechanical properties above 1273K, showing a ductile- brittle transition behavior up to the temperature. Furthermore, it can seen that 25% YSZ/75% NiCrAlY composite gave the highest fracure strength and fracture energy among the mixing ratio tested over the temperature range.

혈장지 단백질에 대한 핵자기 공명 분광 분석 (The proton nuclear magnetic resonance spectral analysis of human blood plasma lipoprotein)

  • 송인찬;강사욱;김노경;임정기;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1989년도 춘계학술대회
    • /
    • pp.29-34
    • /
    • 1989
  • 300 MHz proton NMR spectra of human blood plasma were analyzed by deconvolution of spectrum, and we compared its results with Fossel's test in normal (15 cases), liver cancer (14 cases) , and other cancer (14 cases) groups. This analysis had enabled us to obtain dynamic characteristics of each individual lipoprotein. As a result of deconvolution method, the VLDL and chylomicron intensity level were found to be elevated in the patients with liver cancer. Moment ratio values of $CH_2$ resonance in the raw spectrum were found to be higher than the normal group for patients with, malignant tumors other than liver cancer. These differences between the three groups could not be found in the conventional Fossel's test. We could simulate plasma spectra by addition of spectra of individual lipoproteins through deconvolution method. Further clinical trials in larger populations and additional biochemical method may shed new light on many of clinical and biochemical interests for knowing characteristics about lipoprotein not separated from blood and the background of Fossel test.

  • PDF

ADHESION STRENGTH OF DIAMOND COATED WC-Co TOOLS USING MICROWAVE PLASMA CVD

  • Kiyama, Nobumichi;Sakamoto, Yukihiro;Takaya, Matsufumi
    • 한국표면공학회지
    • /
    • 제29권5호
    • /
    • pp.540-544
    • /
    • 1996
  • To apply the CVD diamond film to coated tools, it is necessary to make adhesion strength between diamond film and substrate stronger. So adhesion strength of diamond coated WC-Co tools using Microwave Plasma CVD and cutting test of Al-18mass%Si alloy using diamond cutting tools were studied. Diamond coating was carried out using Microwave Plasma CVD apparatus. Reaction gas was used mixture of methane and hydrogen. Substrate temperature were varied from 673K to 1173K by control of microwave output power and reaction pressure. By observation of SEM, grain size became larger and larger as substrate temperature became higher and higher. Also all deposits were covered with clear diamond crystals. XRD results, the deposits were identified to cubic diamond. An analysis using Raman spectroscopy, the deposit synthesized at lower substrate temperature (673K) showed higher quality than deposit synthesized at higher substrate temperature (1173K). As a result of scratch adhesion strength test, from 873K to 1173K adhesion strength decreased by rising of substrate temperature. The deposit synthesized at 873K showed best adhesion strength. In the cutting test of Al-18mass%Si alloy using diamond coated tools and the surface machinability of Al-Si works turned with diamond coating tools which synthesized at 873K presented uniform roughness. Cutting performance of Al-18mass%Si alloys using diamond coated WC-Co tools related to the adhesion strength.

  • PDF

광중합기를 이용한 광학적 치아우식활성도 검사법 (DEVELOPMENT OF OPTICAL CARIES ACTIVITY TEST USING DENTAL CURING LIGHT)

  • 이난영;김미라;오유향;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제31권4호
    • /
    • pp.671-679
    • /
    • 2004
  • 레이저와 플라스마 광, 할로겐 광 중합기를 이용하여 각 개인의 우식 활성토를 측정할 수 있는지를 규명하기 위해 7-8세 아동 45명을 대상으로 치아의 순면과 협면에 각 광원을 조사하고 특수 필터를 사용하여 초기 치아우식증으로 판별된 치아의 개수를 측정하여 기존의 우식활성도 측정방법인 dDfFtT rate와 mutans streptococci 측정법, Lactobacilli 측정법과 비교, 평가하고 그 특이도, 민감도, 예측력을 평가하였다. 1. 아르곤 레이저, 플라스마 광, 할로겐 광 조사시 육안검사시 보다 유의하게 많은 초기우식 병소가 관찰되었다(p<0.05). 2. 아르곤 레이저, 플라스마 광, 할로겐 광을 이용한 우식활성도 측정법은 dDfFtT rate와 양의 상관관계 (${\gamma}=0.42,\;0.41,\;0.39$)를 보였다(p<0.01). 3. 기존의 우식활성도 측정방법을 기준으로 하여 평가한 결과 특이도와 민감도, 예측력은 모두 레이저가 가장 높았으며 플라스마 광, 할로겐 광 순으로 나타났다. 이상의 결과를 종합하여 볼 때 아르곤 레이저와 플라스마 광, 할로겐 광을 이용한 형광법은 모두 양호한 진단학적 지표를 보여줌으로써 향후 광학적 우식활성검사법으로 활용 가능성이 높을 것으로 사료된다.

  • PDF