• Title/Summary/Keyword: Plasma process

Search Result 2,599, Processing Time 0.031 seconds

Evaluation of Biocompatibility of Extracorporeal Circuit - Development of a Quantification Technique using in-vivo Injection of Tc99m Radioactive Platelets - (체외순환도관의 혈액적합성 평가 - 방사선 동위원소(Tc99m) 활성화 혈소판의 생체 내 주입을 이용한 정량분석법의 개발 -)

  • Lee, Sung-Ho;Sun, Kyung;Choi, Jai-Geol;Son, Ho-Sung;Jung, Jae-Seung;Ahn, Sang-Soo;Oh, Hye-Jung;Lee, Whan-Sung;Lee, Hye-Won;Kim, Kwang-Taik;Jeong, Yoon-Seop;Kim, Young-Ha;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.171-176
    • /
    • 2002
  • Background: Blood-foreign interaction cause activation of coagulation and inflammatory process that may lead to multiorgan dysfunction and determine the surgical outcomes. Of the methods for assessing the biocompatibility, the platelet adhesion study is considered as the most valuable evaluation step in blood-foreign interaction. As the most studies have used in-vitro or ex-vivo conditions, we have developed a technique of quantification for platelet adhesion on the blood contact surface by using in-vivo injection of radioactive platelets. Material and Method: A coupled bypass circuit was designed to connect the proximal and descending thoracic aorta in 6 piglets(20∼25 Kg). One side of the circuit tube was consisted of a heparin coated PVC tube(10mm in ID, n=6, Experimental group), and the other, a non-heparin coated PVC tube(10mm in ID, n=6, Control group). After cannulation, the blood was circulated through the circuit for 2 hours. Platelet concentrate was prepared from homologous pig blood 24 hours before the experiment. The platelet concentrate was incubated with Tc-99m-HMPAO for 30 min and then centrifuged for 10 min. The supernatant was discarded and the radio-labeling efficacy was measured. The radio-labeled platelet concentrate was mixed with the autologous plasma to make the volume 5 ml, and the mixture was injected intravenously into the experimental animal. After 2 hour circulation, 5 pieces of the specimen(10mm in length each) were obtained from each PVC tube. The radioisotopes were counted with a gamma counter(Cobra ll, Packard, USA), and the ratio of radioisotope count was compared between the control and experimental group. Result: The radioisotope count number was 537.3221.1 Ci/min in the control group and 311.1 184.5 Ci/min in the experimental group(p=0.0104). The ratio between the groups was 1 to 0.58 (p=0.004). Conclusion: In vivo quantification using technetium-99m-HMPAO labeled platelets is simple and reproducible in evaluating platelet adhesion on a foreign surface. We suggest this technique to be a useful tool for blood compatibility test.

Rapid Detection of Radioactive Strontium in Water Samples Using Laser-Induced Breakdown Spectroscopy (LIBS) (Laser-Induced Breakdown Spectroscopy (LIBS)를 이용한 방사성 스트론튬 오염물질에 대한 신속한 모니터링 기술)

  • Park, Jin-young;Kim, Hyun-a;Park, Kihong;Kim, Kyoung-woong
    • Economic and Environmental Geology
    • /
    • v.50 no.5
    • /
    • pp.341-352
    • /
    • 2017
  • Along with Cs-137 (half-life: 30.17 years), Sr-90 (half-life: 28.8 years) is one of the most important environmental monitoring radioactive elements. Rapid and easy monitoring method for Sr-90 using Laser-Induced Breakdown Spectroscopy (LIBS) has been studied. Strontium belongs to a bivalent alkaline earth metal such as calcium and has similar electron arrangement and size. Due to these similar chemical properties, it can easily enter into the human body through the food chain via water, soil, and crops when leaked into the environment. In addition, it is immersed into the bone at the case of human influx and causes the toxicity for a long time (biological half-life: about 50 years). It is a very reductive and related with the specific reaction that makes wet analysis difficult. In particular, radioactive strontium should be monitored by nuclear power plants but it is very difficult to be analysed from high-cost problems as well as low accuracy of analysis due to complicated analysis procedures, expensive analysis equipment, and a pretreatment process of using massive chemicals. Therefore, we introduce the Laser-Induced Breakdown Spectroscopy (LIBS) analysis method that analyzes the elements in the sample using the inherent spectrum by generating plasma on the sample using pulse energy, and it can be analyzed in a few seconds without preprocessing. A variety of analytical plates for samples were developed to improve the analytical sensitivity by optimizing the laser, wavelength, and time resolution. This can be effectively applied to real-time monitoring of radioactive wastewater discharged from a nuclear power plant, and furthermore, it can be applied as an emergency monitoring means such as possible future accidents at a nuclear power plants.

Autoradiographic Studies on the Inhibitory Effect of Dibutyryl Cyclic AMP on Mouse Oocyte Maturation in Vitro (Dibutyryl Cyclic AMP가 생쥐여포난자의 성숙에 미치는 억제효과에 관한 자기방사법적 연구)

  • Choi, Choon-Keun
    • Applied Microscopy
    • /
    • v.7 no.1
    • /
    • pp.21-43
    • /
    • 1977
  • This experiment was undertaken in order to localize the labeled dbcAMP (dibutyryl cyclic AMP) in oocytes whose development has been suppressed by cold dbcAMP for 6 or 19 hours in vitro. Mouse oocytes were obtained from the ovaries of 3-4 week old A strain female mice, by puncturing the Graafian follicles in the modified Krebs-Ringer bicarbonate salt solution under the dissecting microscope. Those oocytes which have intact germinal vesicle were cultured in the basic culture medium supplemented with 0.4% bovine serum albumin (BSA). Cultivation of the oocytes was carried out in a microtube developed by Cho (1974). The cultures were then incubated in a humidified 5% $CO_2$ incubator maintained at $37^{\circ}C$ for 6 or 19 hours (Donahue, 1968). DbcAMP was added to culture medium for a final concentration of 100ug/ml, and $^3H-dbc$ AMP (specific activity 13 Ci/mM) for a final concentration of $40{\mu}Ci/ml$ was also added to the medium. For electron microscopic autoradiography, those oocytes recovered from the culture were washed with phosphate buffer (pH 7.4), and immediately prefixed in a 2.5% glutaraldehyde overnight and postfixed for 2 hours at $4 ^{\circ}C$ in 1% osmium tetroxide in phosphate buffer with pH 7.4 (Palade, 1952). After fixation, the materials were dehydrated in graded alcohol series and embedded in Epon 812 mixture based on the standard procedures (Luft, 1961). The thin sections $600-700{\AA}$ thick were mounted on the grids of 200 meshes. The grids containing sections were coated with a nuclear emulsion Kodak NTB-3 and stored in a cold dark box (at $4^{\circ}C$) for 3 weeks. After exposure, the samples were developed with Kodak D-19 and stained with uranyl acetate and lead citrate. Routine observation was made with Hitachi HU-11E electron microsocope. The results of the observation were as followings: 1. It was found that the labeled dbcAMP penetrated the egg plasma membrane and dispersed at random in the cytoplasm. 2. It was also observed that most of the labeled dbcAMP was attached to microfibrillar lattices portion of the oocyte cytoplasm. There fore, it is presumed that the receptor of the dbcAMP is localized in the microfibrillar lattices of the oocyte. 3. It also seems that some other cell organells such as mitochondria, Golgi complex, cortical granules are not directly related to the action of the dbcAMP. 4. The labeled dbcAMP was neither observed in the membrane nor in the nucleus. Therefore, it seems that there is no relationship between the concentration of dbcAMP and the nuclear membranous permeability. 5. There was no difference in number of dbcAMP particles when oocytes were cultured for 6 hours and 19 hours. 6. However, it was observed that, in same of the oocytes suppressed in germinal vesicle by dbcAMP for 19 hours, cell organells were moved and concentrated to a small portion of the cytoplasm, and that the morphology of the organells greatly changed to an abnormal. form. Therefore, it is supposed that those oocytes were in the process of degeneration. From the above results, it is expected that dbcAMP penetrated the egg membrane and was bound to the receptor which seems to be located in the microfibrillar lattiees portion, and that this dbcAMP-receptor complex inhibited some enzyme system of the oocytes which are essential for the germinal vesicle breakdown.

  • PDF

APOPTOTIC EFFECT IN COMBINATION OF CYCLOSPORIN A AND TAXOL ON ORAL SQUAMOUS CELL CARCINOMA CELL LINE THROUGH THE PI-3 KINASE/AKT1 PATHWAY (구강 편평세포암종 세포주에서 Cyclosporin A와 Taxol 투여시 PI-3 kinase/Akt1 Pathway에 의한 세포사멸 병용효과)

  • Kim, Kyu-Young;Lee, Jae-Hoon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.426-436
    • /
    • 2007
  • Oral cancer take up 2-6% of all carcinomas and squamous cell carcinoma, which is the most common type in oral cancer, has a poor prognosis due to its high metastasis and recurrence rates. In treating oral cancer, chemotherapy to the primary, metastasized and recurrent lesion is a very important and useful treatment, even though its widespread usage is limited due to high general toxicity and local toxicity to other organs. Taxol, a microtubule stabilizing agent, is an anticancer drug that induces cell apoptosis by inhibiting depolymerization of microtubules in between the metaphase and anaphase of the cell mitosis. Recently, its effectiveness and mechanism on various tumor has been reported. However, not much research has been done on the application of Taxol to oral squamous cell carcinoma. Cyclosporin A, which is an immunosuppressant, is being used on cancers and when co-administered with Taxol, effectiveness of Taxol is enhanced by inhibition of Taxol induced multidrug resistance. In this study, Cyclosporin A with different concentration of Taxol was co-administered to HN22, the oral squamous cell carcinomacell line. To observe the cell apoptosis and the mechanisms that take part in this process, mortality evaluation of tumor cell using wortmannin, c-DNA microarray, RT-PCR analysis, cytometry analysis and western blotting were used, and based upon the observation on the effect and mechanism of the agent, the following results were obtained: 1. The HN22 cell line viability was lowest when $100{\mu}M$ of Wortmannin and $5{\mu}g/ml$ of Taxol were co-administered, showing that Taxol participates in P13K-AKT1 pathway. 2. In c-DNA microarray, where $1{\mu}g/ml$ of cyclosporine A and 3mg/ml of Taxol were co-administered, no up regulation of AKT1, PTEN and BAD c-DNA that participate in cell apoptosis was observed. 3. When $1{\mu}g/ml$ of Cyclosporin A was applied alone to HN22 cell line, no difference was found in AKT1, PTEN and BAD mRNA expression. 4. Increased AKT1, mRNA expression was observed when $3{\mu}g/ml$ of Taxol was applied alone to HN22 cell line. 5. When $1{\mu}g/ml$ of Cyclosporin A and Taxol($3{\mu}g/ml\;and\;5{\mu}g/ml$) were co-administered to HN22 cell line, PTEN mRNA expression increased, whereas AKT1 and BAD mRNA decreased. 6. As a result of cytometry analysis, in the group of Cyclosporin A($1{\mu}g/ml$) and Taxol($3{\mu}g/ml$) co-administration, increased Annxin V was observed, which shows that apoptosis occurred by deformation of plasma membrane. However, no significant difference was observed with vary ing concentration. 7. In western blot analysis, no caspase 3 was observed in the group of Cyclosporin A($1{\mu}g/ml$) and Taxol($3{\mu}g/ml$) co-administration. From the results of this study, it can be concluded that synergistic effect can be observed in combination therapy of Taxol and Cyclosporin A on oral squamous cell carcinoma cell line, where decreased activity of the cell line was observed. This resulted in decreased AKT1 and BAD mRNA and increased PTEN mRNA expression and when wortmannin and Taxol were co-administered, the viability decreased which confirms that Taxol decreases the viability of tumor cell line. Hence, when Taxol and cyclosporine A are co-administered, it can be assumed that cell apoptosis occurs through AKt1 pathway.

Property of Nickel Silicide with 60 nm and 20 nm Hydrogenated Amorphous Silicon Prepared by Low Temperature Process (60 nm 와 20 nm 두께의 수소화된 비정질 실리콘에 따른 저온 니켈실리사이드의 물성 변화)

  • Kim, Joung-Ryul;Park, Jong-Sung;Choi, Young-Youn;Song, Oh-Sung
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.6
    • /
    • pp.528-537
    • /
    • 2008
  • 60 nm and 20 nm thick hydrogenated amorphous silicon(a-Si:H) layers were deposited on 200 nm $SiO_2$/single-Si substrates by inductively coupled plasma chemical vapor deposition(ICP-CVD). Subsequently, 30 nm-Ni layers were deposited by an e-beam evaporator. Finally, 30 nm-Ni/(60 nm and 20 nm) a-Si:H/200 nm-$SiO_2$/single-Si structures were prepared. The prepared samples were annealed by rapid thermal annealing(RTA) from $200^{\circ}C$ to $500^{\circ}C$ in $50^{\circ}C$ increments for 40 sec. A four-point tester, high resolution X-ray diffraction(HRXRD), field emission scanning electron microscopy(FE-SEM), transmission electron microscopy(TEM), and scanning probe microscopy(SPM) were used to examine the sheet resistance, phase transformation, in-plane microstructure, cross-sectional microstructure, and surface roughness, respectively. The nickel silicide from the 60 nm a-Si:H substrate showed low sheet resistance from $400^{\circ}C$ which is compatible for low temperature processing. The nickel silicide from 20 nm a-Si:H substrate showed low resistance from $300^{\circ}C$. Through HRXRD analysis, the phase transformation occurred with silicidation temperature without a-Si:H layer thickness dependence. With the result of FE-SEM and TEM, the nickel silicides from 60 nm a-Si:H substrate showed the microstructure of 60 nm-thick silicide layers with the residual silicon regime, while the ones from 20 nm a-Si:H formed 20 nm-thick uniform silicide layers. In case of SPM, the RMS value of nickel silicide layers increased as the silicidation temperature increased. Especially, the nickel silicide from 20 nm a-Si:H substrate showed the lowest RMS value of 0.75 at $300^{\circ}C$.

Analysis of Trans Fatty Acid Content in Processed Foods and Meat Products (가공식품과 육가공품의 트랜스 지방산 함량 조사)

  • Park, Jung-Min;Ji, Won-Gu;Kim, Eun-Jung;Park, Da-Jung;Shin, Jin-Ho;Shim, Soon-Mi;Suh, Hyung-Joo;Chang, Un-Jae;Kang, Duk-Ho;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.27 no.4
    • /
    • pp.531-537
    • /
    • 2007
  • Small amounts of trans fatty acids exist naturally in beef and dairy foods. Also, they can be produced in the process of partial hydrogenation to manufacture shortning or margarine. They can provide a better palatability and shelf life. According to the recently studies, trans fatty acids can raise health risk such as heart diseases and coronary artery diseases. They can also increase low-density lipoprotein (LDL) cholesterol and decrease high-density lipoprotein (HDL) cholesterol in the blood plasma, therefore increasing the risk of atherosclerosis and diabetes. The aim of this study was to determine total lipids and trans fatty acids (TFAs) content in processed foods and meat products. The analysis of trans fatty acids was performed in 28 samples of donuts, 18 samples of bakeries, 4 samples of frozen doughs, 2 samples of popcorns, and 4 samples of meat products (ham, sausage, nuget, and bacon). Total lipids in processed foods and meat products were extracted by chloroform-Methanol method and acid digestion, respectively. They were analyzed by gas chromatography using a SP-2560 column and flame ionization detector. The amounts of TFAs per 100 g of foods were 0-3.3% (0.74% on average) in donuts, 0.2-5.8% (1.18% on average) in bakeries, 0.2-6.3% (1.93% on average) in frozen doughs, and 0-5.8% in popcorns. Meat products such as ham, sausage, and nuget analyzed 0.1% of TFAs, respectively and trans fatty acids in bacon were not detected. As a result, the distribution of TFAs in processed foods was widely ranged from O% to 6.3% according to manufacturers and types of products, whereas the content of TFAs in meat products ranged from 0% to 0.1%.

Quantitative Elemental Analysis in Soils by using Laser Induced Breakdown Spectroscopy(LIBS) (레이저유도붕괴분광법을 활용한 토양의 정량분석)

  • Zhang, Yong-Seon;Lee, Gye-Jun;Lee, Jeong-Tae;Hwang, Seon-Woong;Jin, Yong-Ik;Park, Chan-Won;Moon, Yong-Hee
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.5
    • /
    • pp.399-407
    • /
    • 2009
  • Laser induced breakdown spectroscopy(LIBS) is an simple analysis method for directly quantifying many kinds of soil micro-elements on site using a small size of laser without pre-treatment at any property of materials(solid, liquid and gas). The purpose of this study were to find an optimum condition of the LIBS measurement including wavelengths for quantifying soil elements, to relate spectral properties to the concentration of soil elements using LIBS as a simultaneous un-breakdown quantitative analysis technology, which can be applied for the safety assessment of agricultural products and precision agriculture, and to compare the results with a standardized chemical analysis method. Soil samples classified as fine-silty, mixed, thermic Typic Hapludalf(Memphis series) from grassland and uplands in Tennessee, USA were collected, crushed, and prepared for further analysis or LIBS measurement. The samples were measured using LIBS ranged from 200 to 600 nm(0.03 nm interval) with a Nd:YAG laser at 532 nm, with a beam energy of 25 mJ per pulse, a pulse width of 5 ns, and a repetition rate of 10 Hz. The optimum wavelength(${\lambda}nm$) of LIBS for estimating soil and plant elements were 308.2 nm for Al, 428.3 nm for Ca, 247.8 nm for T-C, 438.3 nm for Fe, 766.5 nm for K, 85.2 nm for Mg, 330.2 nm for Na, 213.6 nm for P, 180.7 nm for S, 288.2 nm for Si, and 351.9 nm for Ti, respectively. Coefficients of determination($r^2$) of calibration curve using standard reference soil samples for each element from LIBS measurement were ranged from 0.863 to 0.977. In comparison with ICP-AES(Inductively coupled plasma atomic emission spectroscopy) measurement, measurement error in terms of relative standard error were calculated. Silicon dioxide(SiO2) concentration estimated from two methods showed good agreement with -3.5% of relative standard error. The relative standard errors for the other elements were high. It implies that the prediction accuracy is low which might be caused by matrix effect such as particle size and constituent of soils. It is necessary to enhance the measurement and prediction accuracy of LIBS by improving pretreatment process, standard reference soil samples, and measurement method for a reliable quantification method.

Voltammetric Sensor Incorporated with Conductive Polymer, Tyrosinase, and Ionic Liquid Electrolyte for Bisphenol F (전도성고분자, 티로시나아제 효소 및 이온성 액체 전해질을 융합한 전압전류법 기반의 비스페놀F 검출 센서)

  • Sung Eun Ji;Sang Hyuk Lee;Hye Jin Lee
    • Applied Chemistry for Engineering
    • /
    • v.34 no.3
    • /
    • pp.258-263
    • /
    • 2023
  • In this study, conductive polymers and the enzyme tyrosinase (Tyr) were deposited on the surface of a screen printed carbon electrode (SPCE), which can be fabricated as a disposable sensor chip, and applied to the detection of bisphenol F (BPF), an endocrine disruptor with proven links to male diseases and thyroid disorders, using electrochemical methods. On the surface of the SPCE working electrode, which was negatively charged by oxygen plasma treatment, a positively charged conductive polymer, poly(diallyldimethyl ammonium chloride) (PDDA), a negatively charged polymer compound, poly(sodium 4-styrenesulfonate) (PSS), and another layer of PDDA were layered by electrostatic attraction in the order of PDDA, PSS, and finally PDDA. Then, a layer of Tyr, which was negatively charged due to pH adjustment to 7.0, was added to create a PDDA-PSS-PDDA-Tyr sensor for BPF. When the electrode sensor is exposed to a BPF solution, which is the substrate and target analyte, 4,4'-methylenebis(cyclohexa-3,5-diene-1,2-dione) is generated by an oxidation reaction with the Tyr enzyme on the electrode surface. The reduction process of the product at 0.1 V (vs. Ag/AgCl) generating 4,4'-methylenebis(benzene-1,2-diol) was measured using cyclic and differential pulse voltammetries, resulting in a change in the peak current with respect to the concentration of BPF. In addition, we compared the detection performance of BPF using an ionic liquid electrolyte as an alternative to phosphate-buffered saline, which has been used in many previous sensing studies. Furthermore, the selectivity of bisphenol S, which acts as an interfering substance with a similar structure to BPF, was investigated. Finally, we demonstrated the practical applicability of the sensor by applying it to analyze the concentration of BPF in real samples prepared in the laboratory.

The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion (관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구)

  • Park Young-Woo;Her Keun;Lim Jae-Ung;Shin Hwa-Kyun;Won Yong-Soon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.354-358
    • /
    • 2006
  • Background: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of $T-PLS^{TM}$ through the comparison of clinical effects of $T-PLS^{TM}$ (pulsatile pump) and $Bio-pump^{TM}$ (non-pulsatile pump) used for coronary bypass surgery. Material and Method: The comparison was made on 40 patients who had coronary bypass using $T-PLS^{TM}\;and\;Bio-pump^{TM}$ (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. Result: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with $T-PLS^{TM}\;(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. The $T-PLS^{TM}$-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant $(9.7{\pm}3.9\;cc/min\;in\;T-PLS^{TM}\;vs\;8.9{\pm}3.6\;cc/min\;in\;Bio-pump^{TM},\;p=0.20)$. There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with $T-PLS^{TM}\;(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;versus\;46.8{\pm}23.0mg/dL\;in\;Bio-pump^{TM},\;p<0.05)$. There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with $T-PLS^{TM}$, but the death rate was not statistically significant. Conclusion: Coronary bypass was operated with $T-PLS^{TM}$ (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which $Bio-pump^{TM}$ was used. In addition, $T-PLS^{TM}$ used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of $T-PLS^{TM}$.