• Title/Summary/Keyword: Plasma Discharge

Search Result 1,419, Processing Time 0.035 seconds

Effects of ZrO2 Addition on Optical and Electrical Properties of MgO Films as a Protective Layer for AC PDPs (ZrO2 첨가에 따른 AC PDP 보호막용 MgO 박막의 광학적 전기적 특성)

  • Kim, Chang-Il;Jung, Young-Hun;Lee, Young-Jin;Paik, Jong-Hoo;Choi, Eun-Ha;Jung, Seok;Kim, Jeong-Seok
    • Korean Journal of Materials Research
    • /
    • v.18 no.8
    • /
    • pp.422-426
    • /
    • 2008
  • The effects of an addition of $ZrO_2$ on the microstructure and electrical properties of MgO films as a protective layer for AC plasma display panels were investigated. MgO + a 200 ppm $ZrO_2$ protective layer prepared by e-beam evaporation exhibited a secondary electron emission coefficient ($\gamma$) that was improved by 21% compared to that of a pure MgO protective layer. The relative density and Vickers hardness increased with a further addition of $ZrO_2$. These results suggest that the discharge properties and optical properties of MgO protective layers are closely related to the relative density and Vickers hardness. The good optical and electrical properties of $\gamma$, at 0.080, a grain size of $19\;{\mu}m$ and an optical transmittance of 91.93 % were obtained for the MgO + 200 ppm $ZrO_2$ protective layer sintered at $1700^{\circ}C$ for 5 hrs.

Nasal adenocarcinoma in a dog (개의 비강샘암종 증례)

  • Yoon, Jeong-Sik;Jung, Ji-Youl;Jo, Suk-Hee;Kim, Jae-Hoon;Woo, Gye-Hyeong;Jeon, Jae-Nam;Kim, Jae-Hoon
    • Korean Journal of Veterinary Research
    • /
    • v.49 no.1
    • /
    • pp.67-71
    • /
    • 2009
  • A 10-year old female Yorkshire terrier with nasal discharge and swelling was referred to the local animal hospital. Abnormal mass of right nasal cavity was detected in physical examination and radiography. According to the radiographs of the head, there was an evidence of bony destruction in right nose. Oronasal fistula was detected in right maxillary canine teeth. After surgical excision, the sample of nasal mass was refereed to Pathology Department of Veterinary Medicine in Jeju National University. Grossly, the enlarged mass was soft and 3 ${\times}$ 3 cm in size. Histopathologically, the neoplastic mass was composed of tubular to tubulopapillary structures which were lined by single to 6~7 layers of cuboidal to ciliated columnar cells. These neoplastic cells showed invasive tendency to adjacent normal parenchyma. They had uniform, round to oval nuclei, cytoplasm with small vacuoles and indistinct cellular margin. The number of mitotic figures was varied in different areas, ranged from 0 to 4 per high power field. Necrotic foci and infiltration of inflammatory cells including neutrophils, lymphocytes, and plasma cells also presented in the mass. Immunohistochemically, the neoplastic cells demonstrated strong positive reaction for cytokeratin (CK) 18 but were negative for CK 7 and 8. Based on the gross, histopathology and immunohistochemistry, this mass was diagnosed as nasal adenocarcinoma originated from respiratory epithelium.

Observation of Light-Propagation along the Tube of Cold Cathode Fluorescent Lamp (냉음극 형광램프의 광 전파)

  • Cho, Y.H.;Jin, D.J.;Kim, J.H.;Han, S.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.114-126
    • /
    • 2011
  • The light propagation along a long positive column has been observed in a cold cathode fluorescent lamp. The optical signals are observed with the DC and AC voltage power during lamp operation. The light propagating is observed in the operation with the DC-rippled voltage as well as the AC-voltage. The optical signals propagate from the high voltage side to the ground. These signals show two kinds of features according to the before and after Townsend breakdown. At the dark current before Townsend breakdown, the optical intensity is damped and the propagation velocity is $10^4{\sim}10^5m/s$. At the high current of normal glow after Townsend breakdown, the propagation velocity is 1$10^5{\sim}10^6m/s$ without damping.

Electrochemical Performance of AlF3-Coated LiV3O8 for Aqueous Rechargeable Lithium Ion Batteries

  • Tron, Artur;Kang, Hyunchul;Kim, Jinho;Mun, Junyoung
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.60-68
    • /
    • 2018
  • In aqueous rechargeable lithium ion batteries, $LiV_3O_8$ exhibits obviously enhanced electrochemical performance after $AlF_3$ surface modification owing to improved surface stability to fragile aqueous electrolyte. The cycle life of $LiV_3O_8$ is significantly enhanced by the presence of an $AlF_3$ coating at an optimal content of 1 wt.%. The results of powder X-ray diffraction, energy dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, inductively coupled plasma-optical emission spectrometry, and galvanostatic charge-discharge measurements confirm that the electrochemical improvement can be attributed mainly to the presence of $AlF_3$ on the surface of $LiV_3O_8$. Furthermore, the $AlF_3$ coating significantly reduces vanadium ion dissolution and surface failure by stabilizing the surface of the $LiV_3O_8$ in an aqueous electrolyte solution. The results suggest that the $AlF_3$ coating can prevent the formation of unfavorable side reaction components and facilitate lithium ion diffusion, leading to reduced surface resistance and improved surface stability compared to bare $LiV_3O_8$ and affording enhanced electrochemical performance in aqueous electrolyte solutions.

The Fine Structure of Human Fetal Nail Matrix (한국인 태아 조기질의 미세구조에 관한 연구)

  • Sohn, Hyung-Sun;Choi, Jae-Kwon;Chung, Yun-Young;Bae, Choon-Sang
    • Applied Microscopy
    • /
    • v.26 no.1
    • /
    • pp.79-93
    • /
    • 1996
  • The differentiation of nail matrix and fine structure of matrix cells were studied with light and electron microscope using specimens from nails of thumb finger in Korean fetuses 14 to 24 weeks old. Fetal nail matrix consisted of two horizontal layers, thicker ventral and thinner dorsal matrices, originating from invagination of epidermis in proximal nail field. Matrix being generally thicker in its distal region than the apex became gradually thickened with increase of the fetal age. Each matrix consisted of single layer of basal cells and multiple layers of squamous cells which are arranged close to and parallel to the central axis of the nail mairix. The process of keratinization of fetal nail matrix was noted to be occured concurrently in the ventral and dorsal matrices along the central axis of matrix toward distal and dorsal direction. Squamous cells became matured with accumulation of tonofilaments, increase of keratohyalin granules, discharge of membrane coating granules, and narrowing of intercellular spaces, thickening of plasma membrane and finally being transformed into horny cells of nail plate. Horny cells of nail plate filled with fibrous elements in the electron dense amorphous substance. These findings of keratinization process of fetal nail matrix appeared to be similar to those of keratinization in epidermis and inner root sheath of the hair. In the nail matrix, however, corresponding region to the keratogenous zone of growing hair follicle was not observed. Vacuolated squamous cells of nail matrix seen on light microscopy was considered to be artefactual product, but squamous cells with condensed small nuclei rarely found adjacent nail plate was considered to be one of the squamous cells with unknown function. Proximal end of nail plate was observed on dorsal surface of nail field distal to the proximal nail fold at 14 and 16 weeks old human embryos. Proximal prolongation of the proximal end of nail plate was occured with advancing fetal age and afterward 21 weeks nail plate invaded into nail matrix. Melanin granule containing cells and Merkel cells were present only on the basal layer of dorsal nail matirx.

  • PDF

Growth of vertically aligned carbon nanotubes on a large area Si substrates by thermal chemical vapor deposition

  • Lee, Cheol-Jin;Park, Jung-Hoon;Son, Kwon-Hee;Kim, Dae-Woon;Lyu, Seung-Chul;Park, Sung-Hoon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.212-212
    • /
    • 2000
  • Since the first obserbvation of carbon nanotubes, extensive researches have been done for the synthesis using arc discharge, laser vaporization, and plasma-enhanced chemical vapor deposition. Carbon nanotubes have unique physical and chemical properties and can allow nanoscale devices. Vertically aligned carbon nanotubes with high quality on a large area is particularly important to enable both fundamental studies and applications, such as flat panel displays and vacuum microelectronics. we have grown vertically aligned carbon nanotubes on a large area of Si substrates by thermal chemical vapor deposition using C2H2 gas at 750-950$^{\circ}C$. we deposited catalytic metal on Si susbstrate using thermal evaporation. The nanotubes reveal highly purified surface. The carbon nanotubes have multi-wall structure with a hollow inside and it reveals bamboo structure agreed with base growth model. Figure 1 shows SEM micrograph showing vertically aligned carbon nanotubes whih were grown at 950$^{\circ}C$ on a large area (20mm${\times}$30mm) of Si substrates. Figure 2 shows TEM analysis was performed on the carbon nanotubes grown at 950$^{\circ}C$ for 10 min. The carbon nanotubes are multi-wall structure with bamboo shape and the lack of fringes inside the nanotube indicates that the core of the structure is hollow. In our experiment, carbon nanotubes grown by the thermal CVD indicate base growth model.

  • PDF

Venous Thromboembolism Following Acute Ischemic Stroke: A Prospective Incidence Study

  • Ko, Keun Hyuk;Kang, Ji-Hoon;Kang, Sa-Yoon;Lee, Jung Seok;Song, Sook-Keun;Oh, Jung-Hwan;Kim, Joong-Goo;Han, Eun Young;Lee, Ho Kyu;Choi, Jay Chol
    • Journal of Neurocritical Care
    • /
    • v.11 no.2
    • /
    • pp.102-109
    • /
    • 2018
  • Background: A sians were known to have a relatively lower incidence of venous thromboembolism (VTE), and there is insufficient evidence to suggest a specific D-dimer threshold level for screening VTE in patients with acute stroke. Methods: We prospectively enrolled patients with acute ischemic stroke admitted to Jeju National University Hospital. The inclusion criteria were: 1) aged ${\geq}18$ years, 2) admission within seven days of symptom onset, and 3) an initial National Institute of Health Stroke Scale (NIHSS) score >1 for the affected lower limb. Ultrasound scans of the lower limbs and plasma D-dimer assays were performed on days 7-14 and 15-28 after stroke onset. Results: Of 285 patients admitted during the study period, 52 patients met inclusion criteria (mean age 74.5, male 40.4%, median initial NIHSS score 12, and unable to walk unassisted at discharge 76.9%). During 7-14 days, 23 of 52 patients (44.2%) had a D-dimer level above 1.57 mg/L, and 9.6% had a level above 5.50 mg/L. Proximal deep vein thrombosis (DVT) was detected in 3 patients (5.8%, 95% confidence Interval 1.2-16.0%) on ultrasound examination. All DVTs were found in elderly female patients with severe leg weakness. No patient was diagnosed with pulmonary embolism during the study period. Conclusion: The incidence of VTE seems to be very low among Korean patients with acute ischemic stroke. Advanced age, female sex, and severe leg weakness were important risk factors for developing DVT in this study.

Effect of ZnO Nanoparticle Presence on SCC Mitigation in Alloy 600 in a Simulated Pressurized Water Reactors Environment

  • Sung-Min Kim;Woon Young Lee;Sekown Oh;Sang-Yul Lee
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.6
    • /
    • pp.401-411
    • /
    • 2023
  • This study investigates the synthesis, characterization, and application of zinc oxide (ZnO) nanoparticles for corrosion resistance and stress corrosion cracking (SCC) mitigation in high-temperature and high-pressure environments. The ZnO nanoparticles are synthesized using plasma discharge in water, resulting in rod-shaped particles with a hexagonal crystal structure. The ZnO nanoparticles are applied to Alloy 600 tubes in simulated nuclear power plant atmospheres to evaluate their effectiveness. X-ray diffraction and X-ray photoelectron spectroscopy analysis reveals the formation of thermodynamically stable ZnCr2O4and ZnFe2O4 spinel phases with a depth of approximately 35 nm on the surface after 240 hours of treatment. Stress corrosion cracking (SCC) mitigation experiments reveal that ZnO treatment enhances thermal and mechanical stability. The ZnO-treated specimens exhibit increased maximum temperature tolerance up to 310 ℃ and higher-pressure resistance up to 60 bar compared to non-treated ZnO samples. Measurements of crack length indicate reduced crack propagation in ZnO-treated specimens. The formation of thermodynamically stable Zn spinel structures on the surface of Alloy 600 and the subsequent improvements in surface properties contribute to the enhanced durability and performance of the material in challenging high-temperature and high-pressure environments. These findings have significant implications for the development of corrosion-resistant materials and the mitigation of stress corrosion cracking in various industries.

A Study on the characteristic analysis and optimization according to Ballast design of Induction Lamp (고출력 무전극램프의 점등회로 설계를 통한 특성분석 및 최적화에 관한 연구)

  • Chung, Young-Il;Jung, Dae-Chul;Park, Dae-Hee;Kim, Yong-Kab
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.1
    • /
    • pp.31-37
    • /
    • 2017
  • In this paper, we implemented for the development of a high output induction lamp system, which lamp design is optimized by gas type, mixing ratio, pressure and discharge tube size, amalgam type and mixing ratio, and characteristics of ferrite core in the lamp. It's the circuit design by improving the power factor and efficiency according to the driving method, which has analyzing the characteristics according to the waveform and frequency. Finally, luminaries design part for applying the optimal lighting system considering the surrounding environment, the characteristics of the lighting circuit for electrodeless lamp has analyzed and the improvement has been proceeded. In conclusion, the driving frequency has optimized at 135kHz with degrading $7{\sim}10^{\circ}C$ based on the results of the optical characteristics of the induction lamp on peak noise FET(Q3,Q4) damage.

Magnetron Sputter Coating of Inner Surface of 1-inch Diameter Tube

  • Han, Seung-Hee;An, Se-Hoon;Song, In-Seol;Lee, Keun-Hyuk;Jang, Seong-Woo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.135-135
    • /
    • 2015
  • Tubes are of extreme importance in industries as for fluid channels or wave guides. Furthermore, some weapon systems such as cannons use the tubes as gun barrels. To increase the service life of such tubes, a protective coating must be applied to the tubes' inner surface. However, the coating methods applicable to the inner surface of the tubes are very limited due to the geometrical restriction. A small-diameter cylindrical magnetron sputtering gun can be used to deposit coating layers on the inner surface of the large-bore tubes. However, for small-bore tubes with the inner diameter of one inch (~25 mm), the magnetron sputtering method can hardly be accommodated due to the space limitation for permanent magnet assembly. In this study, a new approach to coat the inner surface of small-bore tubes with the inside diameter of one inch was developed. Instead of using permanent magnets for magnetron operation, an external electro-magnet assembly was adopted around the tube to confine the plasma and to sustain the discharge. The electro-magnet was operated in pulse mode to provide the strong axial magnetic field for the magnetron operation, which was synchronized with the negative high-voltage pulse applied to the water-cooled coaxial sputtering target installed inside the tube. By moving the electro-magnet assembly along the tube's axial direction, the inner surface of the tube could be uniformly coated. The inner-surface coating system in this study used the tube itself as the vacuum chamber. The SS-304 tube's inner diameter was 22 mm and the length was ~1 m. A water-cooled Cu tube (sputtering target) of the outer diameter of 12 mm was installed inside of the SS tube (substrate) at the axial position. The 50 mm-long electro-magnet assembly was fed by a current pulse of 250 A at the frequency and pulse width of 100 Hz and 100 usec, respectively. The calculated axial magnetic field strength at the center was ~0.6 Tesla. The central Cu tube was synchronously driven by a HiPIMS power supply at the same frequency of 100 Hz as the electro-magnet and the applied pulse voltage was -1200 V with a pulse width of 500 usec. At 150 mTorr of Ar pressure, the Cu deposition rate of ~10 nm/min could be obtained. In this talk, a new method to sputter coat the inner surface of small-bore tubes would be presented and discussed, which might have broad industrial and military application areas.

  • PDF