• Title/Summary/Keyword: Plant Status Monitoring

Search Result 135, Processing Time 0.026 seconds

Design and Implementation of Factory Equipment Monitoring System using Grid-based Key Pre-Distribution (그리드 기반 키 선분배 방식을 사용하는 공장 설비 모니터링 시스템 설계 및 구현)

  • CHO, YANGHUI;PARK, JAEPYO;YANG, SEUNGMIN
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.51-56
    • /
    • 2016
  • In this paper, we propose an Arduino-based plant monitoring system. The proposed system is based on the Arduino platform, using an environmental sensor and a pressure sensor for measuring temperature, humidity and illuminance in order to monitor the state of the environment and the facilities of the plant. Monitoring data are transmitted to a ZigBee coordinator connected to a server through a radio frequency transceiver. When using a pressure sensor and the environment sensor data stored on the host server, checking the pressure in the environment of the plant and equipment is intended to report any alarm status to the administrator. Using a grid line-based key distribution scheme, the authentication node dynamically generates a data key to protect the monitoring information. Applying a ZigBee wireless sensor network does not require additional wiring for the actual implementation of a plant monitoring system. Possible working-environment monitoring of an efficient plant can help analyze the cause of any failure by backtracking the working environment when a failure occurs. In addition, it is easy to expand or add a sensor function using the Arduino platform and an expansion board.

Current Status on the Development and Application of Fatigue Monitoring System for Nuclear Power Plants (원전 피로 감시 시스템 개발 및 적용 현황)

  • Boo, Myung Hwan;Lee, Kyoung Soo;Oh, Chang Kyun;Kim, Hyun Su
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.13 no.2
    • /
    • pp.1-18
    • /
    • 2017
  • Metal fatigue is an important aging mechanism that material characteristics can be deteriorated when even a small load is applied repeatedly. An accurate fatigue evaluation is very important for component structural integrity and reliability. In the design stage of a nuclear power plant, the fatigue evaluations of the Class 1 components have to be performed. However, operating experience shows that the design evaluation can be very conservative due to conservatism in the transient severity and number of occurrence. Therefore, the fatigue monitoring system has been considered as a practical mean to ensure safe operation of the nuclear power plants. The fatigue monitoring system can quantify accumulated fatigue damage up to date for various plant conditions. The purpose of this paper is to describe the fatigue monitoring procedure and to introduce the fatigue monitoring program developed by the authors. The feasibility of the fatigue monitoring program is demonstrated by comparing with the actual operating data and finite element analysis results.

Status of Radiation Dose and Radioactive Contamination due to the Fukushima Accident

  • Baba, Mamoru
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.133-140
    • /
    • 2016
  • Backgrounds: The accident at Fukushima Daiichi Nuclear Power Plant (NPP), March 2011, caused serious radioactive contamination over wide area in east Japan. Therefore, it is important to know the effect of the accident and the status of NPP. Materials and Methods: This paper provides a review on the status of radiation dose and radioactive contamination caused by the accident on the basis of publicized information. Results and Discussion: Monitoring of radiation dose and exposure dose of residents has been conducted extensively by the governments and various organizations. The effective dose of general residents due to the accident proved to be less than a mSv both for external and internal dose. The equivalent committed dose of thyroid was evaluated to be a few mSv in mean value and less than 50 mSv even for children. Monitoring of radioactivity concentration has been carried out on food ingredients, milk and tap water, and actual meal. These studies indicated the percentage of foods above the regulation standard was over 10% in 2011 but decreasing steadily with time. The internal dose due to foods proved to be tens of ${\mu}Sv$ and much less than that due to natural $^{40}K$ even in the Fukushima area and decreasing steadily, although high level concentration is still observed in wild plants, wild mushrooms, animals and some kind of fishes. Conclusion: According to extensive studies, not only the effect of the accident but also the pathway and countermeasures against radioactive contamination have been revealed, and they are applied very effectively for restoration of environment and reconstruction of the area.

Heterogeneous Equipment Support Monitoring System for Operation and Maintenance of Solar power plant (태양광발전소 운영유지보수를 위한 이기종 장비 지원 모니터링 시스템)

  • Lim, Su-Chang;Hong, Seok-Hoon;Park, Chul-Young;Cho, Hyun-Wook;Song, Beob-Seong;Kim, Jong-Chan
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.9
    • /
    • pp.1171-1180
    • /
    • 2020
  • The number of the PV systems installed in south korea has been gradually increasing. Interest of operation & management of PV System is rising up as PV System installation trends to increase. The vital function of operation & management is the monitoring system. Most monitoring systems are only available for equipment of suppliers and manufacturers. In this study, a monitoring system was implemented to support multi-domain equipment (inverter, junction box, water distribution board, environmental sensors) that are not limited to specific manufacturers. Monitoring system includes a visualization function, which makes it easy for users to check the power generation and the operation status of the equipment of PV System. In the future, this monitoring system will be utilized as an operation & maintenance foundation element in the PV system industry.

Development of the MES Framework for Injection Mold Plant (사출 금형공장에 적합한 MES Framework 설계 및 구현)

  • 오용주;강정진;허영무;조명우;신봉철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1239-1242
    • /
    • 2003
  • The target of this paper is the manufacturing system of mould plant and the object of system development is the reduction of lead times and the improvement of product quality. From the existing MES framework. we found the module to apply in the mould plant, designed and developed the function of the module. Also. as the environment of development is based on internet, we can check and analysis correctly the status of mould plant from remote site.

  • PDF

Monitoring Onion Growth using UAV NDVI and Meteorological Factors

  • Na, Sang-Il;Park, Chan-Won;So, Kyu-Ho;Park, Jae-Moon;Lee, Kyung-Do
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.50 no.4
    • /
    • pp.306-317
    • /
    • 2017
  • Unmanned aerial vehicles (UAVs) became popular platforms for the collection of remotely sensed data in the last years. This study deals with the monitoring of multi-temporal onion growth with very high resolution by means of low-cost equipment. The concept of the monitoring was estimation of multi-temporal onion growth using normalized difference vegetation index (NDVI) and meteorological factors. For this study, UAV imagery was taken on the Changnyeong, Hapcheon and Muan regions eight times from early February to late June during the onion growing season. In precision agriculture frequent remote sensing on such scales during the vegetation period provided important spatial information on the crop status. Meanwhile, four plant growth parameters, plant height (P.H.), leaf number (L.N.), plant diameter (P.D.) and fresh weight (F.W.) were measured for about three hundred plants (twenty plants per plot) for each field campaign. Three meteorological factors included average temperature, rainfall and irradiation over an entire onion growth period. The multiple linear regression models were suggested by using stepwise regression in the extraction of independent variables. As a result, $NDVI_{UAV}$ and rainfall in the model explain 88% and 68% of the P.H. and F.W. with a root mean square error (RMSE) of 7.29 cm and 59.47 g, respectively. And $NDVI_{UAV}$ in the model explain 43% of the L.N. with a RMSE of 0.96. These lead to the result that the characteristics of variations in onion growth according to $NDVI_{UAV}$ and other meteorological factors were well reflected in the model.

A Study on the Hierarchical Real-time Operation Control and Monitoring for an Flexible Manufacturing System (유연생산시스템의 계층구조적 실시간 운용제어 및 모니터링에 관한 연구)

  • Kim, Jong-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.4
    • /
    • pp.36-43
    • /
    • 1992
  • This paper presents a hierarchical real-time operation control and monitoring scheme of the FMS/CIM center which has been implemented at the Automation and Systems Research Institute of Seoul National University. The hierarchical structure of the whole scheme consists of three lavers. The upper layer is in charge of on-line scheduling, computer network control, shop-floor monitoring and command generation for AGV dispatching, machining, assembly, inspection, set-up, etc. The middle layer has six modules, which are installed in the FMS host computer with the upper layer and run on the multi-tasking basis. Each module is connected to one of six cell controllers distributed in the FMS model plant and transfers operation command down to each cell controller through the Ethernet/TCP-IP local area network. The lower layer is comprised of six cell control software modules for machining cell, assembly cell, inspection cell, set-up stations. AS/RS and AGV. Each cell controller reports the status of the manufacturing facilites to the middle layer as well as ecxecuting the appropriate sequence control of the manufacturing processes.

  • PDF

Development of On-Line Partial Discharge Monitoring System in High Voltage Motors (고압전동기 운전중 부분방전 감시 시스템 개발)

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1175-1178
    • /
    • 2004
  • On-line partial discharge(PD) monitoring system has been developed to monitor in operating large motor stator insulations. This system makes use of remote diagnosis techniques for the evaluation of PD activity in the control center of thermal power plant. This system can be remotely accessed via a modem to build database, analyze status and interpret the pattern of PD activity. A personnel computer is generally connected to ten motors to continuous measurement of the PD activity. The test data can be easily interpreted by a maintenance staff. For assessing the condition of stator winding in motors, this system ensures a reliable measurement and accurate estimation. Capacitive couplers used for on-line PD measurement have been 80pF. The maximum PD magnitude(Qmax), PD pattern and normalized quantity number(NQN) were performed by this system.

  • PDF

Design and Implement of Smart Gateway Interface API for Real-time Monitoring in Smart Factory (스마트 팩토리에서 원격 실시간 모니터링을 위한 게이트웨이 인터페이스 연동 API 설계 및 구현)

  • Jeon, Dong-cheol;Lee, Byung Mun;Hwang, Heejoung
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.5
    • /
    • pp.601-612
    • /
    • 2019
  • As the $4^{th}$ industrial revolution is accelerating, IT convergence application technologies are attracting attention in various fields. In the manufacturing industry, Smart Factory technology, which is blended with IT technology, has been developed to solve the problem casued by the decrease of the labor force, and a monitoring server is required to remotely control the equipment or to inquire about the operation status of the factory. In this paper, we designed and implemented RESTful API for data sharing between factory equipment and monitoring server in Smart Factory. In order to verify the designed API, a testbed was operated for an actual plastics manufacturing plant. As a result, it was confirmed that the testbed can be operated normally in actual operating environment.

Small Unmanned Aerial System (SUAS) for Automating Concrete Crack Monitoring: Initial Development

  • Kang, Julian;Lho, B.C.;Kim, J.W.;Nam, S.H.
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.310-312
    • /
    • 2015
  • Small Unmanned Aerial Systems (SUAS) have been gaining a special attention in the U.S. recently because it is capable of getting aerial footages conveniently and cost effectively, but also because of its potential threat to the safety of our society. Regarding the benefits, one can easily find successful cases. For example, remote controlled or pre-programmed unmanned aircraft help ranch owners monitor their livestocks or crop harvesting status cost-effectively without having to hire human pilots. The professionals in the construction industry also acknowledge the benefits they could gain from using SUAS. Some firms already use a small unmanned aircraft for monitoring their construction activities, which may help project managers figure out construction progress, resolve disputes in real time, and make proactive decisions for quality control. However, there are many technical challenges that my hinder the use of small unmanned aircraft in the construction industry. This paper explores opportunities and challenges in using unmanned aircraft to monitor concrete cracks on the surface of containment building in the nuclear power plant.

  • PDF