• Title/Summary/Keyword: Plant Safety

Search Result 2,560, Processing Time 0.041 seconds

DISTRIBUTED HMI SYSTEM FOR MANAGING ALL SPAN OF PLANT CONTROL AND MAINTENANCE

  • Yoshikawa, Hidekazu
    • Nuclear Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.237-246
    • /
    • 2009
  • Digitalization of not only non-safety but also safety-grade I &C systems with full computerized Main Control Room (MCR) is the recent trend of I&C systems of nuclear power plants (NPP) around the world, while plant maintenance has been shifting from traditional time based maintenance to condition based maintenance. In order to cope with the new trend of operation and maintenance in NPP, a concept of online distributed diagnostic system for both plant operation and maintenance has been proposed in order to further improve both the plant efficiency and the work environment of plant operation staff members by organizational learning. In this respect, the research subjects of human machine interface (HMI) for the online distributed diagnostic system are also discussed for supporting the plant personnel at both MCR and local working places in the plant by the application of advanced ICT (Information and Communication Technologies).

Establishment of Analytical Method for Residues of Ethychlozate, a Plant Growth Regulator, in Brown Rice, Mandarin, Pepper, Potato, and Soybean Using HPLC/FLD

  • Kim, Jae-Young;Lee, Jin Hwan;Lee, Sang-Mok;Chae, Young-Sik;Rhee, Gyu-Seek;Chang, Moon-Ik
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.2
    • /
    • pp.111-119
    • /
    • 2015
  • BACKGROUND: Ethychlozate (ECZ) is a plant growth regulator of synthetic auxin for agricultural commodities (ACs). Accurate and sensitive method to determine ECZ in diverse ACs on global official purpose is required to legal residue regulation. As the current official method is confined to the limited type of crops with poor validation, this study was conducted to improve and extend the ECZ method using high-performance liquid chromatography (HPLC) in all the registered crops with method verification. METHODS AND RESULTS: ECZ and its acidic metabolite (ECZA) were both extracted from acidified samples with acetone and briefly purified by dichloromethane partition. ECZ was hydrolyzed to form ECZA and the combined ECZA was finally purified by ion-associated partition including hexane-washing. The instrumental quantitation was performed using HPLC/ FLD under ion-suppression of ECZA with no interference by sample co-extractives. The average recoveries of intra- and inter-day experiment ranged from 82.0 to 105.2% and 81.7 to 102.8%, respectively. The repeatability and reproducibility for intra- and inter-day measurements expressed as a relative standard deviation was less than 8.7% and 7.4%, respectively. CONCLUSION: Established analytical method for ECZ residue in ACs was applicable to the nation-wide pesticide residues monitoring program with the acceptable level of sensitivity, repeatability and reproducibility.

PERIODIC SAFETY REVIEW ON KORI UNIT 1 (고리 1호기 주기적안전성 평가)

  • Kim, Tae-Ryong
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.403-414
    • /
    • 2003
  • Periodic safety review on Kori Unit 1 has been successfully done for the first time in Korea. 11 safety factors of the review were fully evaluated in accordance with the domestic legal system. Although it is the oldest nuclear power plant in Korea, Kori Unit 1 was found to have maintained good operating conditions and continuously enhanced its safety by implementing post-TMI action plans and other safety issues, such as replacing steam generators and process/control system. It can be therefore confirmed that safe operation of Kori Unit 1 is guaranteed until next periodic safety review. Nevertheless, some corrective action items were recommended to enhance further its safety level, such as equipment qualification, additional ageing management program, strengthening of some procedures related to administration and human factor. The results of PSR can be utilized for the continued operation beyond the design life as long as the plant safety is maintained and improved. Experiences of the PSR on Kori Unit 1 can be also applied to PSR on other plants.

  • PDF

A Study on Risk Analysis and Acident Prevention Heater Interlock By-pass (Heater interlock by-pass로 인한 위험분석 및 사고방지에 대한 연구)

  • Son Jae-geun;Park Kyo-Shik;Kang Tae-Yeon;Yeo Yeong-Koo
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.1 s.18
    • /
    • pp.24-27
    • /
    • 2003
  • In this paper it was investigated 15 heaters of CDU plant heater, NCC plant heater, CO plant heater, Aromatic plant heater and so on while running in our country. It was also analysed the standard of operation procedure, the action in alarm, the interlock system, the operating situation of the interlock by-pass and major accident about the heater and so on. This paper presents the installation of the on-line monitoring, the additional installation of the local pressure gauge and temperature gauge, the check in starting operation,'the management of the interlock by-pass, the change of manufacturer causing the disorder of instrument sensor, the management method of DCS alarm for methods of the interlock prevention and facilities improvement. It was few information about the heater interlock in the inside and outside of the country We mainly have studied with reflecting the opinion of the operator and manager on site, the sheet of process trouble and operation procedure and so on. we think that the accident relating to the interlock will significantly reduce if the companies apply the conclusion of this study(i.e. methods of the interlock prevention and facilities improvement).

  • PDF

Human Factors Design Review of CFMS for Improving the Safety of Nuclear Power Plant (원전의 안전성 제고를 위한 CFMS의 인간공학적 설계 검토)

  • 이용희;정광태
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.201-208
    • /
    • 1997
  • In order to improve the safety of nuclear power plant, we performed a human factors review for the CFMS(Critical Function Monitoring system) design of nuclear power plant. Three works were performed in this study. In first work, we developed human factors engineering program plan(HFEPP) and human factors engineering verification and validation plan (HFE-V & V plan) to effectively perform CFMS design and review. In second work, we identified human engineering discrepancies(HEDs) for CFMS design through human factors design review and proposed those resolutions. In the third work, we developed the evaluation and management methodology for identified KEDs. Methodology developed in this study can be used in other complex system as well as in CFMS design review.

  • PDF

Development of an Intellectual Property Core for Floating Point Calculation for Safety Critical MMIS

  • Mwilongo, Nelson Josephat;Jung, Jae Cheon
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.17 no.2
    • /
    • pp.37-48
    • /
    • 2021
  • Improving the plant protection system against unforeseen changes/transients during operation is essential to maintain plant safety. Under this condition, it requires rapid and accurate signal processing. The use of an Intellectual Property (IP) core for floating point calculations for Safety Critical MMIS can make numerical computations easier and more precise, improving system accuracy. It can represent and manipulate rational numbers as well as a much broader range of values with dynamic range in nuclear power plant. Systems engineering approach (SE) is used through the development process, it helps to reduce complexity and avoid omissions and invalid assumptions as delivers a better understanding of the stakeholders needs. For the implementation on the FPGA target board, the 32-bit floating-point arithmetic with IEEE-754 standards has designed using Simulink model in Matlab for all operations of addition, subtraction, multiplication and division and VHDL code generated.

Antibacterial and virucidal activity of 28 extracts from plants endemic to Korea against Bacillus cereus, Staphylococcus aureus, and murine norovirus

  • Hyun-Joo Chang;Ji Hye Han;Nari Lee;Sung-Wook Choi
    • Journal of Applied Biological Chemistry
    • /
    • v.66
    • /
    • pp.345-352
    • /
    • 2023
  • Antibacterial activity against foodborne bacteria (Bacillus cereus, Staphylococcus aureus, Salmonella Enteritidis) and inhibitory activity against murine norovirus, a human norovirus surrogate, of 28 extracts from plants endemic to Korea were investigated in this study. All plant extracts showed antibacterial activity only against gram-positive bacteria, B. cereus and S. aureus. Extracts from Callistemon speciosus and Nymphaea tetragona showed inhibition zones of 16.54 and 24.35 mm against B. cereus and S. aureus, respectively, presenting the highest antibacterial activities recorded in this study. Among all samples, Ardisia japonica extract at concentrations of 100 and 200 ㎍/mL showed the highest virucidal activities of 96.6 and 100.0%, respectively. Ardisia japonica, Duchesnea indica, Polygonum aviculare, and Geum japonicum extracts showed high antibacterial and virucidal activity simultaneously without Raw 264.7 cell cytotoxicity. These plant extracts may serve as potential antimicrobials to control foodborne infections.

A Study on the Improvement of Safety Awareness through Process Safety Management of Biogas Plant

  • Hong, Eun Ju;Jeong, Myeong Jin
    • International Journal of Advanced Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.104-110
    • /
    • 2019
  • Since 1986, domestic sewage treatment plants have installed and operated biogas plants that produce biogas (digested gas) using food, livestock manure and sewage sludge as part of the use of alternative energy for energy independence. Despite concerns about safety accidents and risks of large-scale accidents due to the continuous expansion of biogas plants, the Ministry of Environment has managed and supervised biogas plants to be environmental plants, focusing on environmental management. There is a lack of safety awareness of workers' processes. Only recently has the process safety management (PSM) system been implemented in biogas plants, but workers' perceptions of process safety have changed. As there is a difference in the degree of safety process management and safety awareness among workers, it is necessary to establish clear and systematic safety management standards. Therefore, The purpose of this study is to examine whether the application of the plant safety management (PSM) system to biogas plants is effective for workers' safety awareness in order to ensure safe operation of biogas plants and prevent workers' safety accidents in advance.

Commercial Grade Item Dedication of Digital Devices for Safety-related System in Nuclear Power Plant (원자력발전소 안전등급 계통 적용을 위한 디지털 상용기기 품질검증)

  • Hong, Young Hee;Bae, Byung Hwan;Park, Jaehyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1637-1639
    • /
    • 2014
  • In the past, the analog protection relays have been widely used for the safety-related systems in the nuclear power plants due to their stability and reliability. Meanwhile, as the high performance digital system has been developed, the digital systems have been adopted in the non-safety systems. However, since the digital systems currently used in the non-safety systems were not developed according to Q-class standard, Commercial Grade Item Dedication (CGID) procedure should be performed in order to apply them to the safety-related system. The purpose of this paper is to describe the CGID procedure including the analysis of the hardware architecture as well as the software embedded in protective relay to apply to the emergency diesel generator in the nuclear power plant. The entire CGID procedure was performed strictly according to the international standard and regulations.