• Title/Summary/Keyword: Plant Performance

Search Result 3,390, Processing Time 0.045 seconds

Effect of Recirculated Exhaust Gas upon Performance and Exhaust Emissions in Power Plant Boilers with FGR System (FGR 시스템 공력 플랜트 보일러의 성능 및 배기 배출물에 미치는 재순환 배기의 영향)

  • Bae, Myung-Whan;Jung, Kwong-Ho;Choi, Seung-Chul;Cho, Yong-Soo;Kim, Yi-Suk
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1686-1691
    • /
    • 2004
  • The effect of recirculated exhaust gas on performance and exhaust emissions with FGR rate are investigated by using a natural circulation, pressurized draft and water tube boiler with FGR system operating at several boiler loads and over fire air(OFA) damper openings. The purpose of this study is to apply the FGR system to a power plant boiler for reducing $NO_{x}$ emissions. To activate the combustion, the suction damper of two stage combustion system installed in the upper side of wind box is opened by handling the lever between $0^{\circ}$ and $90^{\circ}$ , and the OFA with 0 to 20% into the flame is supplied, as the combustion air supplied to burner is reduced. It is found that the fuel consumption rate divided by evaporation rate does not show an obvious tendency to increase or decrease with rising the FOR rate, and $NO_{x}$ emissions are decreased, at the same OF A damper opening, as FOR rates are elevated and boiler loads are dropped.

  • PDF

A Development of the Performance Analysis Program Package of the Automatic Temperature Control System for Heating (난방용 자동온도조절기 성능분석용 프로그램 및 패키지 개발)

  • Kim, Yong-Ki;Woo, Nam-Sub;Lee, Tae-Won;Ahn, Byung-Cheon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1209-1214
    • /
    • 2009
  • Various automatic temperature control systems have been used widely in Korea for the conservation of heating energy and the enhancement of thermal comfort in residential buildings. But the heating control performance for automatic temperature control systems extensively vary with the design and operational conditions of the heating system, the climate condition and others. It was introduced in this study a numerical calculation program package to analyze heating control characteristics of the automatic temperature control system. This package is able to analyze the room air temperature, return water temperature, supplied heating flux and flow rate, and so on. One the other hand, the simulation results were verified by comparing with the field test results.

  • PDF

Performance and Operation of Biological Activated Carbon (생물활성탄접촉조의 성능과 조작)

  • Lee, Gangchoon;Yoon, Taekyung
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.83-90
    • /
    • 2006
  • Performance and operation of BAC in ozone-BAC advanced water treatment process were investigated using the pilot scale test plant built in D water purification plant. The performance was evaluated by the removal efficiencies of DOC, BDOC, ammonia nitrogen and THMs. The effect of EBCT on DOC removal was experimented for an effective operating condition, and the amount of attached biofilm was analyzed in various water temperatures and position of BAC. Two removal mechanisms, adsorption and biological decomposition by attached biofilm, were predominant to decrease the concentration of various contaminants. DOC was removed 40%, and the removal rate was decreased in winter time due to the lowered activity of attached biofilm. BDOC was effectively removed. THMs and ammonia nitrogen were mainly removed not in ozonation process but in BAC. Water temperature deeply influenced in removal efficiency of ammonia nitrogen. The amount of attached biofilm depended on water temperature and height of packed activated carbon column. Considering DOC removal efficiency and design EBCT of commercial BAC plant, the proper EBCT was 12.5 minutes.

Algorithms for effective combustion control of refuse incineration plant (쓰레기 소각로의 효율적인 연소제어를 위한 퍼지예측제어 알고리즘)

  • 박종진;강신준;우광방
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.20-23
    • /
    • 1997
  • Refuse incineration plant operations involve many kinds of uncertain factors, such as the variable physical properties of refuse as fuel and the complexity of the burning phenomenon. That makes it very difficult to apply conventional control methods to the combustion control of the refuse. In this paper, an adaptive fuzzy model predictive controller is proposed for the combustion control of the refuse. And computer simulation was carried out to evaluate performance of the proposed controller.

  • PDF

Analysis of Dynamic Behavior of Natural Circulation Heat Recovery Steam Generators

  • Kim, Sung-Ho;Lee, Chi-Hwan;Cho, Chang-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.134.3-134
    • /
    • 2001
  • The dynamic behavior of heat recovery steam generators for combined cycle power plant is simulated in cases of startup and shutdown conditions. To ensure performance and design data, dynamic model of the HRSG was developed and dynamic simulation was performed. The dynamic analysis will undoubtedly reduce costs which is associated with plant startup and contribute to a smooth commercial plant operation.

  • PDF

The study of Line - frequency Control in performance improvement of plant Control system. (계통주파수 제어를 위한 발전제어 특성개선)

  • Hur, Sung-Khang;Song, Seong-Il
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.114-117
    • /
    • 1987
  • This study is concerned with the improvement of the Automatic Boiler Control and Turbine Governor system to maintain line - frequency within $60{\pm}0.1\;HZ$. This describes the current problems of plant control system, the method, and equipments to be developed for each plant based on the experimental test were carried out at field, and, lastly, the results of the study with the progress of it.

  • PDF

Performance Analysis of the Mid-Level Communication Network for DCS in NPP (원자력 발전소 분산제어 시스템을 위한 중위 계층 통신망의 성능 분석)

  • Lee, Sung-Woo;Yim, Han-Suck
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.816-818
    • /
    • 1998
  • In this paper, a highly reliable communication network for DCS (Distributed Control System) in nuclear power plant is designed. The structure and characteristics of DCS in nuclear power plant is briefly explained. The features needed for a communication network for DCS in nuclear power plant is described. According to the above features, a layer structure for the communication network is determined and each layer is designed in detail. Accuracy of the model was evaluated by computer simulation.

  • PDF

Aldose reductase inhibition of the methanolic extracts of selected noxious and exotic plants

  • Lee, Ju Sung;Woo, Dong Geon;Cho, Ga Eul;Lee, Sanghyun
    • Journal of Applied Biological Chemistry
    • /
    • v.62 no.2
    • /
    • pp.203-209
    • /
    • 2019
  • The inhibition of aldose reductase (AR) by the extracts from sixteen noxious and exotic plants was examined. Among them, Aster pilosus showed the highest inhibition of AR ($IC_{50}$ value $0.11{\mu}g/mL$). This study showed that A. pilosus with promising AR-inhibitory activities can be utilized for the development of natural therapies for treating and managing diabetic complications.