• 제목/요약/키워드: Plant Capacity

검색결과 1,525건 처리시간 0.03초

면진된 비상디젤발전기의 지진위험도 평가 (Seismic Risk Evaluation of Isolated Emergency Diesel Generator System)

  • 김민규;대조정수;전영선
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.217-222
    • /
    • 2007
  • An Emergency Diesel Generator (EDG) is one of the safety related equipments of a Nuclear Power Plant. The seismic capacity of an EDG in nuclear power plants influences the seismic safety of the plants significantly. A recent study showed that the increase of the seismic capacity of the EDG could reduce the core damage frequency (CDF) remarkably. It is known that the major failure mode of the EDG is a concrete coning failure due to a pulling out of the anchor bolts. The use of base isolators instead of anchor bolts can increase the seismic capacity of the EDG without any major problems. This study introduces a seismic risk analysis method and presents sample results about the seismically isolated and conventional EDG system.

  • PDF

개구 저감률에 의한 원전 SC벽체의 내력 평가 (Evaluation of Structural Capacity of SC Walls in Nuclear Power Plant accounting for the Area Lost to Openings)

  • 정철헌;정래영;문일환;이정휘
    • 대한토목학회논문집
    • /
    • 제33권6호
    • /
    • pp.2181-2193
    • /
    • 2013
  • 지금까지 수행된 개구부가 존재하는 벽체에 대한 연구는 대부분 RC 벽체에 대해서 수행되었으며, SC(Steel plate Concrete) 벽체에 설치되는 개구부에 대한 연구는 수행된 예가 적다. 최근에 국내에서 개발된 SC 벽체는 원전구조물에 일부 적용되고 있지만, 관련 설계기준인 KEPIC-SNG에서도 개구부를 갖는 SC 벽체에 대한 설계법은 명확하게 정의되지 않았다. 본 연구에서는 원전구조물내 벽체에 설치되는 SC 벽체를 대상으로 개구 저감률이 구조내력에 미치는 영향을 평가하였다. 개구 저감률을 고려한 구조내력 평가 결과는 실험 및 수치해석 결과와 비교분석하였다.

Performance Analysis of Gas Turbine for Large-Scale IGCC Power Plant

  • Joo, Yong-Jin;Kim, Mi-Yeong;Park, Se-Ik;Seo, Dong-Kyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.415-419
    • /
    • 2016
  • As the need for clean coal technology has grown, so has the global research and development efforts into integrated gasification combined cycle (IGCC) plants. An IGCC plant couples a gas turbine to a gasification block. Various technical and economic problems exist in designing such a system. One such problem is the difficulty in realizing economies of scale because the single-train flow capacity of commercial IGCC synthetic gas turbine plants is limited; the capacity does not exceed a net power rating of 300 MW. To address this problem, this study modeled and simulated a synthetic gas turbine with the goal of evaluating the feasibility of a 500 MW or larger IGCC plant. First, a gas turbine with the best output and efficiency was chosen for use with natural gas. The turbine was modeled using GateCycle (a simulation tool), and the integrity of the model validated by comparing the result to the design value. Next, off-design modeling was carried out for a gas turbine with synthetic gas based on its on-design model, and the result was compared with the study result of the gas turbine manufacturer. The simulation confirmed that it is possible to create a large capacity IGCC plant by undertaking the remodeling of a gas turbine designed to use natural gas into one suitable for synthetic gas.

정수장 마이크로 소수력 발전기 적용에 대한 연구 (A Study on the Application of Micro Hydro Power Generator at the Water Treatment Plant)

  • 김종겸;박영진;김일중
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.67-72
    • /
    • 2014
  • Inflow or outflow from the water treatment plant and the sewage water has potential energy. If this potential energy can be converted into electrical energy by water turbine generator, it can help to save energy because of the high capacity utilization. So recently, micro hydro power plant is reviewed in the water treatment facility. If generation capacity is low, induction generator is primarily used. If output capacity is low, generated power is supplied to the inside load. Induction generator can cause voltage drop by the inrush current at a start-up and requires reactive power for magnetization. In this study, we analyzed the flow of power and voltage variation against inrush current that occurs when the induction generator starts under the terms that loads of linear and non-linear of the water purification plant are used. Analysis results are that the voltage drop is within an allowable range and the power factor is slightly reduced by the need of reactive power.

Overwintering Capacity Affected by Seeding Time and Method of Chinese Milk Vetch, Astragalus sinicus L., in Upland Field

  • Lee Ji Hyun;Kang Byeung Hoa;Shim Sang In
    • 한국작물학회지
    • /
    • 제50권2호
    • /
    • pp.67-72
    • /
    • 2005
  • Overwintering capacity, closely related to winter hardiness, of Chinese milk vetch planted with different sowing times and sowing practices was investigated to improve the incorporation into cropping system in Korea. The tolerance to low temperature was evaluated with $LT_50$ using leaf disc leaching method. Dry weight of CMV was reduced remarkably with delayed planting from Sep. 5 to Oct. 20. The differences in tolerance to freezing temperature were not conspicuous among CMV genotypes, however, the differences between genotype (collections at different regions) were due to the plant architecture, mainly to the leaf angle. The crouching genotype collected at central region of Korean peninsula, which showed excellent freezing tolerant, has planophile leaves. The feature of internal constituents of CMV genotypes did not show any noticeable differences with respect to the freezing tolerance which evaluated by leaf disc leaching experiment. To overcome the poor overwintering capacity, tolerant genotype should be developed by selection with considering the plant architecture. The reduction of CMV growth during overwintering period was ameliorated with furrow-sowing under late-sown condition, therefore, when the CMV is inevitably sown late after recommended time, the seeds should be sown on furrow to overcome the cold stress.

토양함수량이 인삼의 광합성 및 생육에 미치는 영향 (Effects of Soil Water Regimes on Photosynthesis, Growth and Development of Ginseng Plant (Panax ginseng C. A. Meyer))

  • 이성식;양덕조;김요태
    • 한국작물학회지
    • /
    • 제27권2호
    • /
    • pp.175-181
    • /
    • 1982
  • 사양토에서 인삼생육의 최적 토양 함수량 구명키 위해 토양함수량별 지상하부, 생식생장, 광합성 등을 조사한 바 그 결과는 다음과 같다. 1. 근건물중 및 동직경은 62%(절대수분 13.9%)가 가장 양호하였다. 2. 엽면적, 엽건물중은 62%(절대수분 13.9%)가 가장 양호하였으며 개체당 개화수, 결실율, 종자생산량도 같은 경향이었다. 3. 단위 면적당 광합성량은 토양 함수량이 많을수록 증가하였으나 개체당 광합성량은 62%가 가장 양호하였다. 4. 증산량은 토양함수량과 비례하였으나 기공의 밀도는 반비례하였다.

  • PDF

광해지역 토착 자생식물에 의한 중금속 흡수 (Heavy Metal Uptake by Native Plants in Mine Hazard Area)

  • 최형욱;최상일;양재규
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권3호
    • /
    • pp.27-33
    • /
    • 2010
  • The purpose of this study was in search of native plant species showing metal-resistant property and excessively accumulating heavy metals in metal-contaminated soil or abandoned mines as well as in evaluation of applicability of phytoremediation. In the study area, species showing excessively accumulating heavy metals were a shepherd´s purse, pampas grass, a Korean lettuce, a Hwansam vine, the Korean persicary, a foxtail, a goosefoot, and a water pepper. The first screened plant species in Sambo mine were as shepherd's purse, Korean lettuce and pampas grass Among them the shepherd´s purse can be excluded because it is a seasonal plant and has lower removal capacity for heavy metals. The Korean lettuce was also excluded because of having lower removal capacity for heavy metals. Pampas grass is a highly bionic plant species constantly growing from spring. However it has weak points such as little accumulation capacity for zinc as well as small values of an accumulation factor and a translocation factor. Another problem is regarded as removal of roots after the clean up if pampas grass is applied to a farmland. In Sanyang mine, wormwood and Sorijaengi were considered as adaptable species.

건설전원용량에 따른 신설전원의 안정도특성 (The Stability Dependency of New Generator on the Existing System Capacity)

  • Nam, Sang-Cheon
    • 대한전기학회논문지
    • /
    • 제35권7호
    • /
    • pp.285-295
    • /
    • 1986
  • This study is to investigate the stability of expanded new generator plant depending on the capacity of existing system. We examined the transmitting power limit to the existing system as its capacity increase for the various system configuration with fixed location of plants and substations. The results show that the stability has decreasing tendency when the existing source capacity increase. Thus it can be concluded that new generator has little stability problem when it connected to small system, whereas large existing system capacity gives remarkable difficulty in adopting new generator.

  • PDF

한국 고유의 산채류 첨가 식이가 흰쥐의 지방 대사 및 항산화능과 Cadmium 제독에 미치는 영향 (Effect of Korean Native Plant Diet on Lipid Metabolism, Antioxidative Capacity and Cadmium Detoxification in Rats)

  • 박진아
    • Journal of Nutrition and Health
    • /
    • 제32권4호
    • /
    • pp.353-368
    • /
    • 1999
  • This study was performed to investigate the effects of Korean native plant diets on lipid and cadmium (Cd) metabolisms and also antioxidative enzyme activities in rats. Seventy male Sprague-Dawley rats weighing 210.3$\pm$2.7g were blocked into ten groups according to body weight. Rats were raised for four weeks with diets containing 0 or 0.04%(w/w) cadmium chloride and 5%(w/w) plant powder-Ssook(Artemisia princeps var. orientalis HARA), Chamchwi(Aster scaber THUNB), Gomchwi(Lingularia fischeri TUBCZ). or Solbeerum (Portulaca oleracea LINNE). Food intake, weight gain, food efficiency ratio, and weights of liver, kidney, spleen and epididymal fat were significantly lower in Cd-exposed groups, food efficiency ratio, and weights of liver, kidney, spleen and epididymal fat were significanlty lower in Cd-exposed groups. Plasma total lipid level, liver total lipid, cholesterol and triglycerde concentrations, and fecal total lipid, cholesterol and triglyceride excretions were decreased by Cd administration. Total lipid and triglyceride concentration in plasma and liver were lower in Chamchwi groups together with increased fecal total lipid and triglyceride excretions. Cholesterol concentration in plasma and liver were lower in Gomchwi groups with increased fecal cholesterol excretions. Activities of red-blood-cell superoxide dismutase(SOD), and liver catalase, SOD and glutathione peroxidase (GSH-px) were decreased significantly by Cd administration. Thiobarbituric acid reactive substance(TBARS) concentrations of plasma and liver were increased by Cd administration. Thiobarbituric acid reactive substance(TBARS) concentration of plasma and liver were increased by Cd administration. Administration of plant diets decreased plasma and liver catalase, SOD and GSH-px activities in Cd-free diet groups and increased them in Cd-administered groups. Plasma and liver TBARS concentrations were decreased in animals fed plant diets, with Chamchwi showing the most effective antioxidative capacity. The concentration of Cd accumulated in blood and tissue decreased in Cd-exposed groups fed plant diets. Liver Cd concentration were lower in the Chamchwi and Gomchwi groups, and kidney Cd levels were lower in the Ssook and Chamchwi groups. Among them, Chamchwi was the most effective in Cd detoxification. In conclusion, Chamchwi and Gomchwi were effective in lowering tissue lipid levels, with Chamchwi having the greatest antioxidative and detoxifying effects.

  • PDF

Plant Defense Responses Coming To Shape

  • Kwon, Chi-An
    • The Plant Pathology Journal
    • /
    • 제26권2호
    • /
    • pp.115-120
    • /
    • 2010
  • Although still poorly understood, accumulating evidence clearly supports that plants also have a good immune system which have been developed and acquired during the evolution. The lack of specific mobile immune cells like a B or T cell in plants additionally suggests that most plant cells have capacity for defending themselves against numerous pathogens. Rapidly growing advances in understanding plant defense responses implicate that plant and animal immune responses are evolutionarily convergent although their origins are thought to be different. On the basis of recent findings, here current understanding of plant defense responses will be discussed.