• 제목/요약/키워드: Plane motion accuracy

검색결과 77건 처리시간 0.031초

NC 선반의 정면 운동정도 측정장치의 개발 (Development of plane Motion Accuracy Measurement Unit of NC Lathe)

  • 김영석;한지희;정정표;윤원주;송인석
    • 한국정밀공학회지
    • /
    • 제21권7호
    • /
    • pp.101-106
    • /
    • 2004
  • Measurements of linear motion accuracy for one axis of NC lathe have achieved with laser interferometer system, but measurement of plane motion accuracy for two axes on zx-plane of NC lathe have not achieved with the above system. Therefore in this study, measuring unit system is organized using two optical linear scales in order to acquire error. data during of plane motion of ATC(Automatic Tool Change.) of NC lathe by reading zx-plane coordinates. Two optical linear scales of measuring unit are fixed on zx-plane of NC lathe, and moving part of the scales are fixed to the ATC and then error motion data of z, x-coordinates of the ATC are received from the scales through the PC counter card inserted in computer at constant time intervals using tick pulses coming out from computer. And then, error motion data files acquired from measuring are saved in computer memory and the aspect of plane motion are modeled to plots, and range of the error data, means. average deviations, and standard deviations etc. are calculated by means of statistical treatments using computer programs.

Accuracy and Reliability of The Spine-Pelvis Monitor to Record Three-Dimensional Characteristics of The Spine-Pelvic Motion

  • Kim, Jung-Yong;Yoon, Kyung-Chae;Min, Seung-Nam;Yoon, Sang-Young
    • 대한인간공학회지
    • /
    • 제31권2호
    • /
    • pp.345-352
    • /
    • 2012
  • Objective: The aim of this study is to evaluate the accuracy and reliability of Spine-Pelvis Monitor(SPM) that was developed to measure 3-dimensional motion of spine and pelvis using tilt sensor and gyro sensor. Background: The main cause of low back pain is very much associated with the task using the low back and pelvis, but no measurement technique can quantify the both spine and pelvis. Method: For testing the SPM, 125 angles from three anatomical planes were measured three times in order to evaluate the accuracy and reliability. The accuracy of SPM in measuring dynamic motion was evaluated using digital motion analysis system. The motion pattern captured by two measuring methods was compared with each other. In result, the percentage error and Cronbach coefficient alpha were calculated to evaluate the accuracy and reliability. Results: The percentage error was 0.35% in flexion-extension on sagittal plane, 0.43% in lateral bending on coronal plane, and 0.40% in twisting on transverse plane. The Cronbach coefficient alpha was 1.00, 0.99 and 0.99 in sagittal, coronal and transvers plane, respectively. Conclusion: The SPM showed less than 1% error for static measurement, and showed reasonably similar pattern with the digital motion system. Application: The results of this study showed that the SPM can be the measuring method of spine pelvis motion that enhances the kinematic analysis of low back dynamics.

리니어 스케일을 이용한 NC 선반의 원 운동정도 측정 시스템의 구성 (Organization of Circular Motion Accuracy Measuring System of NC Lathe using Linear Scales)

  • 김영석;김재열;김종관;한지희;정정표
    • 한국공작기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.1-6
    • /
    • 2004
  • Measurements of circular motion accuracy of NC lathe have achieved with ball bar systems proposed by Bryan, but the ball bar systems have ifluenced on the measuring data by way of the accuracy of the balls and the contacts of balls and bar seats. Therefore in this study, error data during of circular motion of ATC(Automatic Tool Changer) of NC lathe will be acquired by reading zx plane coordinates using two optical linear scales. Two optical linear scales of measuring unit are fixed on z-x plane of NC lathe, and the moving part is fixed to ATC and then is made to receive data of coordinates of the ATC at constant time intervals using tick pulses comming out from computer. And then, error data files of radial direction of circular motion are calculated with the data read, and the aspect of circular motion are modeled to plots, and are analysed by means of statistical treatments of circularity, means, standard deviations etc.

리니어 스케일을 이용한 NC 선반의 직선 운동정도 측정 (Measuring of Linear Motion Accuracy of NC Lathe using Linear Scales)

  • 김영석;김재열;한지희;정정표;윤원주;송인석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1243-1248
    • /
    • 2003
  • It is very important to measure linear motion accuracy of NC lathe as it affects all other parts of machines machined by them in industries. If the motion accuracy of NC lathe is bad, the dimension accuracy and the change-ability of works will be bad in the assembly of machine parts. In this paper, computer software systems are organized to measure linear motion of ATC(Automatic tool changer) on zx plane of NC lathe using two linear scales and the time pulses coming out from computer in order to get data at constant time intervals from the linear scales. And each sets of error data obtained from the test is discripted to plots and the results of linear motion errors are expressed as numerics by computer treatment.

  • PDF

Machining Center의 공간정도 측정장치의 개발 (Developement of Measuring Units of Space Motion Accuracy in Machining Center)

  • 김영석;남궁석
    • 한국정밀공학회지
    • /
    • 제12권2호
    • /
    • pp.37-47
    • /
    • 1995
  • In recent years, it has been variously developed for testing the accuracy of circular motion of NC machine tools, for example Telescoping Ball Bar Method by Bryan, Circular test Method by Knapp and $r^{-{\theta} }$ Method by Tsutsumi etc., but these methods are all 2-dimentional measuring methods on plane. These simple methods of circular motion accuracy test of NC machine tools have been studied by many reserchers as above, but it is not yet settled in the code of measuring methods of motion errors of NC machine tools, because of errors of measuring units and sensors, and also especially the difficulties of centering of measuring units and the spindle of machining center. In this paper, in use of 2 rotary encoders and 1 magnetic type linear scale with resolution of 0.5 .mu. m, it has become possible for measuring of 3 dimentional space motion accuracy.

  • PDF

NC 선반에서 직선 사이클 평면 위치결정 정도 측정 시스템의 구성 (The Organization of Measuring Systems of Linear Cycle Plane Positioning Accuracy on NC Lathes)

  • 김영석;김재열;송인석;곽이구;정정표;한지희
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.387-392
    • /
    • 2002
  • It is very important to measure linear cycle plane positioning accuracy of NC lathes as they affect those of all other machines machined by them in industries. For example, if the linear cycle plane positioning accuracy of each axes directions is bad, the accuracy of works will be wrong and the change-ability will be bad in the assembly of machine parts. In this paper, computer software systems are organized to measure linear displacements of ATC(Automatic tool changer) of NC lathes using linear scale and time pulses comming out from computer in order to get data at constant time intervals from the sensors. And each sets of error data gotten from the test is expressed to plots by computer treatment and the results of linear cycle plane positioning error motion estimated to numerics by statistical treatments.

  • PDF

AFM 시스템을 위한 XYZ 3축 스테이지의 설계 (The design of XYZ 3-axis stage for AFM system)

  • 김동민;김기현;심종엽;권대갑;엄천일
    • 한국결정학회:학술대회논문집
    • /
    • 한국결정학회 2002년도 정기총회 및 추계학술연구발표회
    • /
    • pp.36-36
    • /
    • 2002
  • To Establish of standard technique of length measurent in 2D plane, we develope AFM system. The XY scanner scans the sample only in XY plane, while the Z scanner scans the specimen only in Z-direction. Cantilever tip is controlled to has constant height relative to speciman surface by feedback of PSPD signal. To acquire high accuracy, Z-axis measuring sensor will be added.(COXI or others). In this paper we design XYZ stage suitable for this AEM system. For XY stage, single module parallel-kinnematic flexure stage is used which has high orthogonality and minimum out-of-plane motion. To obtain best performance optimal design is performed. For XY stage, to be robust about parasitic motion optimal design of maximizing Z and tilt stiffness is performed under the constraint of motion range and stage size. And for Z stage, optimal design of maximizing 1st resonant frequency is performed. Because if resonant frequency is get higher, scan speed is improved. So it makes reduce the error by sensor drift. Resultly XYZ stage each have 1st natural frequency of 115㎐, 201㎐, 2.66㎑ and range 109㎛, 110㎛, 12㎛.

  • PDF

균형 재활 훈련을 위한 특정 회전 움직임에서 피검자 동작 분석을 위한 깊이 센서 기반 키넥트 시스템의 정확성 및 부정확성 평가 (Evaluation of Accuracy and Inaccuracy of Depth Sensor based Kinect System for Motion Analysis in Specific Rotational Movement for Balance Rehabilitation Training)

  • 김충연;정호현;전성철;장경배;전경진
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권5호
    • /
    • pp.228-234
    • /
    • 2015
  • The balance ability significantly decreased in the elderly because of deterioration of the neural musculature regulatory mechanisms. Several studies have investigated methods of improving balance ability using real-time systems, but it is limited by the expensive test equipment and specialized resources. Recently, Kinect system based on depth data has been applied to address these limitations. Little information about accuracy/inaccuracy of Kinect system is, however, available, particular in motion analysis for evaluation of effectiveness in rehabilitation training. Therefore, the aim of the current study was to evaluate accuracy/inaccuracy of Kinect system in specific rotational movement for balance rehabilitation training. Six healthy male adults with no musculoskeletal disorder were selected to participate in the experiment. Movements of the participants were induced by controlling the base plane of the balance training equipment in directions of AP (anterior-posterior), ML (medial-lateral), right and left diagonal direction. The dynamic motions of the subjects were measured using two Kinect depth sensor systems and a three-dimensional motion capture system with eight infrared cameras for comparative evaluation. The results of the error rate for hip and knee joint alteration of Kinect system comparison with infrared camera based motion capture system occurred smaller values in the ML direction (Hip joint: 10.9~57.3%, Knee joint: 26.0~74.8%). Therefore, the accuracy of Kinect system for measuring balance rehabilitation traning could improve by using adapted algorithm which is based on hip joint movement in medial-lateral direction.

비트 플레인 정합에 의한 디지털 영상 안정화 (Digital image stabilization based on bit-plane matching)

  • 이성희;전승원;고성제
    • 한국통신학회논문지
    • /
    • 제23권6호
    • /
    • pp.1471-1481
    • /
    • 1998
  • 본 논문에서는 비트 플레인 영생(bit-plane image)에서의 정합을 이용하여 디지털 영상 안정화를 수행하는 새로운 기법을 제안한다. 제안된 기법에서는 기존의 전역 탐색 알고리즘을 하나의 비트 플레인으로부터 추출한 이진 영상에 적용함으로써 움직임 추정에 소요되는 계산량을 줄이면서도 기존 방식들보다 우수한 웅직임 추정 성능을 갖도록 하였다. 더욱이 제안된 기법은 조도 변화를 고려하여 비트 플레인을 선정하는데 있어서 적응 기법을 적용함으로써 견고한 성능을 갖도록 하였다. Brute-force 방식을 기준으로 RMSE(root mean square error)를 이용하여 제안하는 방식과 기존의 방식들을 비교하였고, 실험 결과에서 제안하는 방식이 카메라의 움직임 벡터를 기존 방식들보다 정확하게 검출하고 있음을 확인하였다. 또한 제안하는 방식은 기존 방식들에 비해서 연산량이 작고, 보다 간단한 방식으로 디지털 영상 안정화를 수행하고 있다.

  • PDF