• 제목/요약/키워드: Planar Coil

검색결과 72건 처리시간 0.017초

Study of Apparent Diffusion Coefficient Changes According to Spinal Disease in MR Diffusion-weighted Image

  • Heo, Yeong-Cheol;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.146-149
    • /
    • 2017
  • In this study, we compared the standardized value of each signal intensity, the apparent diffusion coefficient (ADC) that digitizes the diffusion of water molecules, and the signal to noise ratio (SNR) using b value 0 400, 1400 ($s/mm^2$). From March 2013 to December 2013, patients with suspicion of simple compound fracture and metastatic spine cancer were included in the MR readout. We used a 1.5 Tesla Achieva MRI system and a Syn-Spine Coil. Sequence is a DWI SE-EPI sagittal (diffusion weighted imaging spin echo-echo planar imaging sagittal) image with b-factor ($s/mm^2$) 0, 400, 1400 were used. Data analysis showed ROI (Region of Interest) in diseased area with high SI (signal intensity) in diffusion-weighted image b value 0 ($s/mm^2$) Using the MRIcro program, each SI was calculated with images of b-value 0, 400, and 1400 ($s/mm^2$), ADC map was obtained using Metlab Software with each image of b-value, The ADC is obtained by applying the ROI to the same position. The standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of simple compression fractures were $0.47{\pm}0.04$ and $0.23{\pm}0.03$ and the standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of the metastatic spine were $0.57{\pm}0.07$ and $0.32{\pm}0.08$ And the standardized values of the two diseases were statistically significant (p < 0.05). The ADC ($mm^2/s$) for b value 400 ($s/mm^2$) and 1400 ($s/mm^2$) of the simple compression fracture disease site were $1.70{\pm}0.16$ and $0.93{\pm}0.28$ and $1.24{\pm}0.21$ and $0.80{\pm}0.15$ for the metastatic spine. The ADC ($mm^2/s$) for b value 400($s/mm^2$) was statistically significant (p < 0.05) but the ADC ($mm^2/s$) for b value 1400 (p > 0.05). In conclusion, multi - b value recognition of signal changes in diffusion - weighted imaging is very important for the diagnosis of various spinal diseases.

소형 모바일 기기용 공진형 무선전력전송 시스템의 공진기 평면화 및 소형화에 따른 특성 연구 (Characteristic Study of Small-sized and Planer Resonator for Mobile Device in Magnetic Wireless Power Transfer)

  • 이훈희;정창원
    • 전자공학회논문지
    • /
    • 제54권4호
    • /
    • pp.16-21
    • /
    • 2017
  • 본 논문은 모바일 기기(노트북, 핸드폰, 태블릿 PC 등)를 위한 공진형 무선전력전송 시스템(Magnetic Resonance - Wireless Power Transfer; MR-WPT)의 실용성을 높이기 위한 평면형 소형 공진기 설계 방법을 제안하였다. 제안된 소형 평면형 공진기는 네 개의 루프와 공진기를 사용하는 공진형 무선전력 시스템에 적용 되며, 또한 무선전력 시스템은 송신기(Tx)와 수신기(Rx)가 동일한 루프와 공진기로 이루어졌다. 제안된 공진기는 나선형(Spiral) 코일의 형태로 소형 모바일 크기에 적합한 $50mm{\times}50mm$의 크기 이내로 설계 되었으며, 나선형 공진기의 선 두께와 선간 갭(gap) 그리고 선의 길이를 달리하는 4종류의 나선형 공진기를 선정하였다. 또한 작은 공진기 부피에서 높은 인덕턴스와 캐패시턴스를 얻기 위해 공진기 기판 (아크릴 ${\varepsilon}_r=2.56$, tan ${\delta}=0.008$)의 양면을 모두 활용하였다. 또한 루프는 공진기 부피를 최소화하기 위해 공진기와 동일 평면상에 설계 하였고, 이 또한 서로 다른 3가지의 크기를 사용하였다. 제안된 무선전력전송 시스템은 Tx와 Rx 두 개의 아크릴 기판에 제작되었으며, Tx와 Rx의 루프와 공진기는 구리시트로 만들어졌다. 제안된 12개의 조합 (공진기 4종 ${\times}$ 루프 3종)의 루프와 공진기에 대한 전력전송효율을 근 전송 거리 (1cm~5cm)상에서 시뮬레이션과 측정을 통해 산출하였다. 측정 결과 전력전송효율은 전송거리 1~5 cm에 따라 ${\fallingdotseq}40%$ 그리고 최대 ${\fallingdotseq}70%$ 이며, 이때 공진주파수는 A4WP 표준 무선전력전송 주파수인${\fallingdotseq}6.78MHz$를 유지한다. 제안된 부피에서 최소화된 평면형의 소형 공진기를 이용한 소형 모바일 기기의 공진형 무선전력 어플리케이션에 대한 가능성을 실험적으로 확인하였다.