유동화공법에 의해 제조한 고유동 콘크리트의 원가분석에 관한 기초적 연구 (A Fundamental Study on the Estimation of Construction Cost of High Fluidity Concrete Applying Flowing Concrete Method)

  • 한민철;손성운;오선교;김성수;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술.기술논문발표회
    • /
    • pp.99-102
    • /
    • 2002
  • This paper discusses the estimation of construction cost of high fluidity concrete using segregation reducing type superplasicizer with 350kgf/cm2 of design strength and 60$\pm$5cm of slump flow in order to verify the cost down effect of high fluidity concrete compared with that of plain concrete with 350kgf/cm2 of design strength and 18cm of slump and with 210kgf/cm2 of design strength and 15cm of slump. According to research, under same strength levels, although material cost of high fluidity concrete is somewhat higher than that of plain concrete due to segregation reducing type superplasticizer, labor cost and equipment cost of high fluidity concrete is cheaper than that of plain concrete. However, based on the strength differences, high fluidity concrete shows lower material cost, labor cost and equipment cost than that of plain concrete due to decreasing in size of member and re-bar caused by high strength development of concrete.

  • PDF

고로슬래그 미분말을 사용한 고유동콘크리트의 내동해성에 관한 실험적 연구 (An Experimental Study on the Frost Resistance of High-Flowing Concrete Using Granulated Blast-Furnace Slag)

  • 김무한;권영진;강석표
    • 콘크리트학회논문집
    • /
    • 제12권2호
    • /
    • pp.43-51
    • /
    • 2000
  • This study is to investigate for the frost resistance of high-flowing concrete using finely ground granulated blast-furnace slag with experimental parameters, such as type of binder, type of superplasticizer and method of curing. The resistance to freezing and thawing of high-flowing concrete by type of binder and superplasticizer is presented differently. Though the frost resistance of high-flowing concrete is satisfactory under standard condition, it is required that high-flowing concrete has entrained air like plain concrete. Because the critical spacing factor, being capacity of frost resistance, of high-flowing concrete is longer that of plain concrete, the frost resistance of high-flowing concrete, using finely ground granulated furnace blast slag, is superior to that of plain concrete.

콘크리트 혼입용 분말형 구체방수재의 품질기준에 관한 연구 (A Study on the Guide Line of Quality of Waterproofing Admixture of Powder Type for Concrete)

  • 우영제;배기선;오상근;김형무
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.967-974
    • /
    • 2000
  • By testing compressive strength, water absorption and water premeablity, to establish the standard of quality of waterproofing admixture of power type for concrete, we propose guide line as following ; $.$Setting time: more than 1 hour, within 10 hours $.$Slump: To be satisfied with request of user $.$Air content: To be satisfied with request of user $.$Safety: Without crack or deformation $.$Ratio of compressive strength: $\circled1$ At 3 days : more than plain specimen by 0.9 (An inorganic material) more than plain specimen by 0.4 (An inorganic material mixed organic) $\circled2$ At 7, 28 days : more than plain specimen by 1.0 $.$Ratio of water absorption Coefficient: $\circled1$An inorganic material: less than plain specimen by 1.0 $\circled2$ An inorganic material mixed organic : under than plain specimen by 0.8 $.$Ratio of water premeablity : $\circled1$ An inorganic material : less than plain specimen by 1.0 $\circled2$ An inorganic material mixed organic : under than plain specimen by 0.8

팽창재를 혼입한 철근콘크리트 슬래브의 휨 거동에 관한 실험적 연구 (Experimental Study on Flexural Behavior of RC Slabs with Expansive Additives)

  • 박홍용;김철영;최익창;배상욱;이호석
    • 콘크리트학회논문집
    • /
    • 제12권4호
    • /
    • pp.31-40
    • /
    • 2000
  • This study aims to improve serviceability of concrete by inducing chemical prestress with the application of expansive additives for concrete. For this purpose, material tests and 4 point-bending tests of RC slabs were performed to verify the effect of expansive additives on the concrete. and the critical aspects of the structural behavior were investigated. The results of the material tests show that the optimal proportion of expansive additives is 13% of total cement weigth and the properties of expansive concrete in that proportion are the same as those of plain concrete. Both the experimental cracking load and service load of the expansive concrete slabs are increased in comparison with those of the plain concrete. In addition to the above results, the deflection of expansive concrete is smaller than that of plain concrete, and permanent strains resulting from cyclic load are decreased. It can be concluded that the use of expansive additives to induce chemical prestress in RC slabs greatly improves the serviceability.

구조체 콘크리트의 건조수축 균열저감에 관한 Mock-up 실험 (Mock-up Test on the Reduction of Drying Shrinkage Crack in Structural Concrete)

  • 윤섭;송승헌;한민철;김경환;정용희;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.393-396
    • /
    • 2005
  • This paper presents the results of drying shrinkage of concrete using shrinkage-reducingadmixture(DSRA) studied by the authors through mock-up test. DSRA is proportioned by expansive admixture and shrinkage reducing agent(SRA). Flowing concrete method is also applied to assist the concrete to reduce drying shrinkage by decreasing water content at the same time. The use of EA and SRA does not affect fluidity, bleeding and setting time. Compressive strength of concrete using EA along with SRA exhibited less than that of plain concrete. However, The compressive strength with combination of EA-SRA along with flowing concrete method shows comparable to that of plain concrete. The application of developed method can contribute to reducing drying shrinkage by as much as 30-40$\%$ compared with that of plain concrete.

  • PDF

고로슬래그미분말을 혼입한 콘크리트의 염분침투성에 미치는 압축하중의 영향 (Effect of Compressive Loading on the Chloride Penetration of Concrete Mixed with Granulated Blast Furnace Slag)

  • 김동훈;임남기;호리구치 다카시
    • 한국건축시공학회지
    • /
    • 제9권6호
    • /
    • pp.71-78
    • /
    • 2009
  • 하중을 고려한 염분침투성의 평가가 대단히 중요한 것으로 확인되었다. 본 연구에서는 압축응력하에서 Plain콘크리트에서는 47%정도, BFS콘크리트에서는 89%정도 증가 하는 것으로 나타났다. 무하중 상태에서 BFS를 혼입한 콘크리트의 확산계수가 BFS 무혼입 콘크리트에 비해 적은 것이 확인되었다. 이러한 영향은 압축응력이 발생하는 환경하에서도 같은 경향을 나타내었다. 압축응력이 작용하는 환경 하에서 BFS콘크리트는 Plain콘크리트와 같이 하중의 증가와 함께 확산계수가 증가하는 것으로 확인 되었다. 또한, Plain콘크리트에 비해 압축하중의 영향을 크게 받는 것으로 확인 되었다. BFS의 비표면적이 높을수록 확산 계수가 작은 것으로 확인되었고, 이러한 경향은 고응력 환경에서 현저히 나타나는 것이 확인되었다. BFS의 치환율이 증가할수록 확산계수가 작은 것이 확인되었다. 또한, 압축응력이 작용하는 환경 하에서 BFS의 치환에 의한 염분침투성의 억제 효과가 더욱 더 현저히 나타나는 것으로 확인되었다.

셀룰로우스섬유보강 콘크리트의 소성수축 균열에 관한 실험적 연구 (Experimental Study for Plastic Shrinkage Cracking of Cellulose Fiber Reinforced Concrete)

  • 원종필;박찬기;안태송
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.319-323
    • /
    • 1998
  • Plastic shrinkage cracking is a major concern for concrete, especially for flat structures as highway pavement, slabs for parking garages, and walls. One of the methods to reduce the adverse effect of plastic shrinkage cracking is to reinforced concrete with short randomly distributed fibers. The contribution of cellulose fiber to the plastic shrinkage crack reduction potential of cement composites and its evaluation are presented in this paper. The effects of differing amounts of fibers(0.9kg/㎥, 1.3kg/㎥, 1.5kg/㎥) were studied. The results of tests of the cellulose fiber reinforced concrete were compared with plain concrete and polypropylene fiber reinforced concrete. Results indicated that cellulose fiber reinforcement showed an ability to reduce the total area and maximum crack width significantly(as compared to plain concreted to plain concrete and polypropylene fiber concrete).

  • PDF

섬유보강에 의한 콘크리트 포장의 초기수축제어 (Early Shrinkage Control of Concrete Pavement by Fiber Reinforcements)

  • 최성용;박종섭;정우태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.433-434
    • /
    • 2010
  • 본 연구는 각 섬유 종류 변화에 따른 콘크리트 포장의 수축특성을 분석하기 위해 각종 길이변화시험을 수행하였다. 그 결과 섬유 보강 콘크리트의 경우가 Plain에 비해 각종 수축저항성능이 향상되는 경향을 나타냈으며 특히, 건조수축에서 우수한 성능을 나타냈고, 국내산 폴리프로필렌 섬유를 혼입한 경우 건조수축에서 Plain에 비해 약 75% 이상 수축량이 감소하였다.

  • PDF

플라이애시를 대량 사용한 콘크리트의 배합설계를 위한 기초적 연구 (A Fundamental Study on the Mix Design in High Volume Fly-Ash Concrete)

  • 심재형;김재환;최희용;강석표;최세진;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.641-646
    • /
    • 2001
  • Generally, when Fly-Ash was used as replacement material of cement in concrete, it might occur retardation of setting and hardening. So, it is unable to use a large amount of Fly-Ash as replacement for cement. However, if it is used as replacement material of fine aggregate in concrete, we can use a large amount of Fly-Ash and settle a problem of natural-aggregate exhaustion. Furthermore, engineering properties of High Volume Fly-Ash Concrete Is better than that of plain concrete But, the larger Fly-Ash is replaced, the more fluidity of High Volume Fly-Ash Concrete decrease, because porous organization of Fly-Ash adsorb water and Superplasticizer. In this study, after appending additional water to High Volume Fly-Ash Concrete in proportion to weight of Fly-Ash, we intend to find proper ratio which doesn't affect strength and satisfy fluidity As a result of this study, it was found that fluidity of mortar with 25~28 percentage of additional water was satisfied with fluidity of plain mortar, and compressive strength of that was similar to plain mortar's

  • PDF

팽창콘크리트를 사용한 RC 슬래브의 휨거동에 관한 연구 (Flexural Behavior of RC Slabs with Expansive Concrete)

  • 박홍용;김철영;최익창;이호석;배상욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.585-588
    • /
    • 1999
  • This study is performed to verify the effect of CSA expansive additives for concrete by material properties test and 4 point-bendig test of RC slabs. The result shows that the variations of compress strength, bending strength, and modulus of elasticity of expansive concrete are the same as those of plain concrete. And the crack load of RC slabs with expansive concrete are increased in comparision with that of plain concrete, but the ultimate strength of RC slabs with expansive concrete is decreased.

  • PDF