• 제목/요약/키워드: Placements

검색결과 152건 처리시간 0.035초

비신축성 직물의 고무 밴드 봉제 조건에 따른 신장 특성 분석 (Characterization of Elongation Behavior According to Sewing Conditions for Elastic Bands on Woven Fabrics)

  • 엄란이;이예진
    • 한국의류학회지
    • /
    • 제45권4호
    • /
    • pp.648-660
    • /
    • 2021
  • This study analyzes how sewing conditions for elastic bands on woven fabrics affect elongation. The directions of the elastic bands were vertical, horizontal, vertical and horizontal crossing, and horizontal and vertical crossing. Intervals between the elastic bands were 3.0 cm and 6.0 cm. The woven fabric was tailored for the elastic band sewing using warp, weft, and bias. Consequently, it was possible to visually confirm elongation differences according to the sewing condition of the elastic bands. A detailed examination demonstrated that the horizontal or vertical placement of elastic bands tailored in a crosswise direction produces high vertical elongation and low horizontal contraction. However, elastic bands sewed in crossing directions, regardless of warp and weft directions, resulted in both high vertical elongation and high horizontal contraction. In all cases, the more elastic bands were used, the higher the horizontal elongation. In conclusion, appropriate placements of elastic bands on woven fabric increases motion convenience.

Optimum actuator placement for damping of vibrations using the Prestress-Accumulation Release control approach

  • Poplawski, Blazej;Mikulowski, Grzegorz;Pisarski, Dominik;Wiszowaty, Rafal;Jankowski, Lukasz
    • Smart Structures and Systems
    • /
    • 제24권1호
    • /
    • pp.27-35
    • /
    • 2019
  • This paper proposes a quantitative criterion for optimization of actuator placement for the Prestress-Accumulation Release (PAR) strategy of mitigation of vibrations. The PAR strategy is a recently developed semi-active control approach that relies on controlled redistribution of vibration energy into high-order modes, which are high-frequency and thus effectively dissipated by means of the natural mechanisms of material damping. The energy transfer is achieved by a controlled temporary removal of selected structural constraints. This paper considers a short-time decoupling of rotational degrees of freedom in a frame node so that the bending moments temporarily cease to be transferred between the involved beams. We propose and test a quantitative criterion for placement of such actuators. The criterion is based on local modal strain energy that can be released into high-order modes. The numerical time complexity is linear with respect to the number of actuators and potential placements, which facilitates quick analysis in case of large structures.

육군 착용형 로봇을 장착하기 위한 기능성 의복 설계 요소 조사 (Survey on the Functional Clothing Design Factors for the Military Wearable Robot)

  • 엄란이;이예진
    • 한국의류학회지
    • /
    • 제45권6호
    • /
    • pp.1004-1016
    • /
    • 2021
  • This study aims to derive the design requirements for functional clothing worn with military wearable robots using a survey of people with military experience. Specifically, 982 adult males with military and muscular exercise experience were surveyed for their demands for the clothing worn with wearable robots during military activities. The study showed that it is necessary to develop functional clothing worn inside robots suitable for frequent movements of soldiers to improve their comfort level of wearable robots. The surveyed soldiers indicated that they preferred the top and bottom clothing with high-pressure levels because the upper body felt fatigued during transportation, while both the upper and lower body got exhausted during marches. The survey of design requirements revealed that the participants preferred a top with long sleeves and a bottom with ankle-length leggings in color similar to current military uniforms. We conclude that it is important to design functional clothing worn inside wearable robots in different forms depending on frequent movements, e.g., with differentiated pressures and material placements.

The Methodological Aspects of Forecasting and the Analysis of Macroeconomic Indicators

  • VYBOROVA, Elena Nikolaevna
    • 동아시아경상학회지
    • /
    • 제10권2호
    • /
    • pp.31-42
    • /
    • 2022
  • Purpose - The main research goals by macroeconomic analysis is to assess the effectiveness of state regulation, the sustainability of development, and the financial stability of the state. Research design, Data, and methodology - The research were analyzed using the methods of multivariate statistics and application of the software package Stat graphics. The volume of data from the 1995 to the 2021 was analyzed by Russian Federation. The scale of research on Belarus: to be analyzed the amount of data from the 2015 by 2021, on Kazakhstan - from the 19941, on Kyrgyzstan - from the 2002, on Tajikistan - from the 2008, on Armenia - from the 2021, on Japan - since the 1970, on China - since the 1950, on South Korea - since the 1953. Result - The methods of multivariate statistics was demonstrated exact of result in forecasting of macroeconomic indicators. The most of tendency with the accurate results of are described using the second-degree polynomials. In the most research of country there are the macroeconomic proportion are broken. Conclusion - In the countries studied, the monetary aggregates have a significant growth rate. The shares with a substantial monetary stock and the speed of its growth are divided in the two groups: having placements in the real sectors of the economy and not having received the same result of development from the growth of the monetary stock.

직무 스트레스와 간호사가 인식하는 간호단위 관리자의 진성 리더십이 임상간호사의 재직의도에 미치는 영향 (Effect of Job Stress and Perception of Unit Managers' Authentic Leadership on the Clinical Nurses' Intention to Stay )

  • 이혜자;채덕희
    • 한국직업건강간호학회지
    • /
    • 제32권3호
    • /
    • pp.99-110
    • /
    • 2023
  • Purpose: This study examined the job stress and perception of unit managers' authentic leadership on clinical nurses' intention to stay in nursing. Methods: This descriptive cross-sectional study utilized self-administered questionnaires. The study recruited a convenience sample of 211 clinical nurses from threertiary hospitals in South Korea. The survey was conducted between July and August 2021. The collected data underwent hierarchical multiple regression analyses. Results: The regression analyses indicated that clinical nurses' intention to stay was significantly associated with job stress (B=-0.06, 95% CI [-0.09, -0.04]), six or more years of clinical practice (B=0.60, 95% CI [0.13, 1.07]), men (B=0.87, 95% CI [0.30, 1.44]), and being placed on their desired nursing unit (B=0.39, 95% CI [0.27, 0.76]). Intention to stay was not found to be associated with authentic leadership by the unit managers. Conclusion: It is essential to implement workplace health promotion programs to prevent and reduce job stress among nurses to retain proficient clinical nurses. Additionally, nursing workforce management strategies tailored to the specific sex and career path of nurses are necessary. Moreover, careful consideration should be given to nursing unit placements that align with the individual aptitudes of nurses.

TOWARDS A SPATIAL FRAMEWORK FOR SUPPORTING BUILDING CONSTRUCTION INSPECTION

  • Saud Aboshiqah;Bert Veenendaal;Robert Corner
    • 국제학술발표논문집
    • /
    • The 5th International Conference on Construction Engineering and Project Management
    • /
    • pp.558-565
    • /
    • 2013
  • The process and efficiency of monitoring building and construction violations is a concern of the construction industry. The detection of violations requires appropriate and sufficiently accurate spatial information to manage and support a comprehensive inspection process and monitor compliance. A building inspection workflow must extract appropriate spatial and measurement in-formation from a variety of sources, identify potential violations across a range of compliance criteria and determine the quality of resulting inspection reports. This paper presents a framework for supporting building inspections using spatial information and methods to detect construction violations and compliance. Current inspection processes involve issues around the identification of building violations, access to building regulations and existing spatial information, integration of a range of spatial and non-spatial information, and the quality of decisions within the inspection workflows. A survey of building inspectors was conducted and used together with the issues identified to establish the requirements for a spatial inspection framework. The results demonstrate how such a framework can support improved decision-making and reduced fieldwork effort in detecting and measuring the accuracy of building violations involving building placements, street offsets and footprint areas.

  • PDF

환자중심의 수직코어 계획을 위한 종합병원 부문간 상관배치에 관한 연구 (A Study on Correlation between Departments Layout of General Hospitals for Patient-centered Vertical Core Plan)

  • 이현진;박재승
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제19권2호
    • /
    • pp.31-40
    • /
    • 2013
  • Purpose: It seems obvious that the hospital structures become more large-sized and tall-risen in Korea today. Nothing is more influential than the vertical core plan on the movements of various people in such large-tall hospitals. The present paper, therefore, aims to study on the efficient hospital core space paying first attention to patients by analysing the data on relations between/among department layouts of vertical and horizontal movements. Methods: This study sampled representative 14 hospitals and drew their degrees of data importance on the basis of precedented relative studies. This study also analysed their placements on the blueprint and made confirmations of their arrangements through their homepage on line. Actual visits were made to make sure of the spacial connections between/among departments in the hospitals as well. Results: Even in emergency case in need for vertical movements, the central main core spaces are usually used, which is because special vertical transportation systems are not provided. In these cases, the main core spaces are very important for those who have to move vertically and/or horizontally according to the locations and types of main cores. While special lifts or dumbwaiters are prepared to install for the important articles, such as samples of pathology department, most patients should share with regular visitors the elevators not separated visually and spatially from them. Implications: Vertical core plans are greatly dependent on the ward types and hospital styles. This study is hopefully expected to contribute itself to the standard setting-up of comfortable and quick vertical core system operations for patients.

Comparison of removal torques between laser-etched and modified sandblasted acid-etched Ti implant surfaces in rabbit tibias

  • Park, Kyung-Soon;Al Awamleh, Abdel Ghani Ibrahim;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권1호
    • /
    • pp.73-78
    • /
    • 2018
  • PURPOSE. The purpose of this study was to analyze the effects of two different implant surface treatments on initial bone connection by comparing the Removal Torque Values (RTQs) at 7 and 10 days after chemically modified, sandblasted, large-grit and acid-etched (modSLA), and Laser-etched (LE) Ti implant placements. MATERIALS AND METHODS. Twenty modSLA and 20 LE implants were installed on the left and right tibias of 20 adult rabbits. RTQs were measured after 7 and 10 days in 10 rabbits each. Scanning electron microscope (SEM) photographs of the two implants were observed by using Quanta FEG 650 from the FEI company (Hillsboro, OR, USA). Analyses of surface elements and components were conducted using energy dispersive spectroscopy (EDS, Horiba, Kyoto, Japan). RESULTS. The mean RTQs were $12.29{\pm}0.830$ and $12.19{\pm}0.713$ Ncm after 7 days (P=.928) and $16.47{\pm}1.324$ and $16.17{\pm}1.165$ Ncm after 10 days (P=.867) for LE and modSLA, respectively, indicating no significant inter-group differences. Pore sizes in the LE were $40{\mu}m$ and consisted of numerous small pores, whereas pore sizes in the modSLA were $5{\mu}m$. In the EDS analysis, Ti, O, and C were the only three elements found in the LE surfaces. Na, Ca, Cl, and K were also observed in modSLA, in addition to Ti, O, and C. CONCLUSION. The implants showed no significant difference in biomechanical bond strength to bone in early-stage osseointegration. LE implant can be considered an excellent surface treatment method in addition to the modSLA implant and can be applied to the early loading of the prosthesis clinically.

상악 전치부에서 단일 치아 발거 후 즉시 임플란트 식립 (Immediate implant placement in areas of aesthetic priority)

  • 이승훈;김영성;김원경;이영규
    • Journal of Periodontal and Implant Science
    • /
    • 제37권3호
    • /
    • pp.637-646
    • /
    • 2007
  • Implants placed immediately after tooth extraction have been shown to be a successfully predictable treatment modality. Several clinical papers suggest that placing implants immediately after tooth extraction may provide some advantages: reduction of the number of surgical procedures or patient visits, preservation of the dimensions of alveolar ridge, and shortening of the interval between the removal of the tooth and the insertion of the implant supported restoration. In this case report, three patients received single immediate implant placements to replace a maxillary anterior tooth at the time of extraction. As the three cases were somewhat different, treatment protocols had to be modified as follows: Case 1. Immediate implant placement with healing abutment connection. Case 2. Immediate implant placement with immediate provisionalization. Case 3. Immediate implant placement with Guided Bone Regeneration(GBR). Every implant of these cases was placed in proper position buccolingually, mesiodistally and apicocoronally, The procedures following implantation such as immediate provisionalization and GBR were free of problem. Healing of each case was uneventful. In all cases, treatment outcomes were mostly satisfactory and the results maintained during follow-up periods. However, one case (Case 3) showed some papilla loss due to failure in delicate soft tissue handling during surgery. This papilla loss was compromised by prosthetic means. In conclusion, immediate implant placement in the fresh extraction socket can be a valid and successful option of treatment in aesthetic area. Moreover, this treatment protocol seems to maintain the preexisting architecture of soft and hard tissues in most cases.

Retrospective clinical study of ultrawide implants more than 6 mm in diameter

  • Ku, Jeong-Kui;Yi, Yang-Jin;Yun, Pil-Young;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.30.1-30.6
    • /
    • 2016
  • Background: The prognosis of wide implants tends to be controversial. While wider implants were initially expected to result in a larger osseointegration area and have higher levels of primary stability, they were reported to have a relatively high rate of failure. The clinical outcome of ultrawide implants of more than 6 mm in diameter was evaluated through a retrospective study. Methods: The investigation was conducted on patients who had received ultrawide implant (${\geq}6mm$ diameter) placements in Seoul National University Bundang Hospital from January 2008 to December 2013. Complications were investigated during the maintenance period, and marginal bone loss was measured using periapical radiography. Primary stability immediately after the implant placement and second stability after second surgery or during impression were measured using $Osstell^{(R)}$ Mentor (Osstell, Sweden) as an implant stability quotient (ISQ). Results: Fifty-eight implants were placed in 53 patients (30 male, 23 female), and they were observed for an average of $50.06{\pm}23.49$ months. The average ISQ value increased from $71.22{\pm}10.26$ to $77.48{\pm}8.98$ (P < 0.005). The primary and secondary stability shows significantly higher at the mandible than at the maxilla (P < 0.001). However, mean survival rate shows 98.28 %. Average marginal bone loss of 0.018 and 0.045 mm were measured at 12 and 24 months after the loading and 0.14 mm at final follow-up date (mean 46.25 months), respectively. Also in this study, the bone loss amount was noticeably small compared to regular implants reported in previous studies. Conclusions: The excellent clinical outcome of ultrawide implants was confirmed. It was determined that an ultrawide implant can be used as an alternative when the bone quality in the posterior teeth is relatively low or when a previous implant has failed.