• Title/Summary/Keyword: Placement plan

Search Result 129, Processing Time 0.041 seconds

Rehabilitation using short implants in the mandibular fully edentulous patient with severe alveolar bone loss: a case report (치조골 흡수가 심한 하악 완전 무치악 환자에서 짧은 임플란트를 이용한 고정성 보철 수복 증례)

  • Hwang, Hee-Sun;Lee, Ki-Young;Kim, Yu-Lee
    • The Journal of the Korean dental association
    • /
    • v.54 no.9
    • /
    • pp.692-702
    • /
    • 2016
  • A short dental implant is considered as possible solution in difficult clinical situations for the placement of a regular length implant. Using a short implant avoiding more invasive surgical procedures simplifies the treatment plan and shortenes the duration of treatment. In this case, 71-year-old female came up with discomfort from her old mandibular denture. As she had fully edentulous mandible and got a negative feedback from removable denture, implant-supported fixed prosthesis was planned. Six short implants were placed on her mandible with severe alveolar bone loss. After 1 year follow up period, implants were well retained with any other abnormal findings. The patient was satisfied with her prostheses and satisfactory outcomes were attained in terms of both esthetic and functional clinical results.

  • PDF

A Study on Criteria of Selecting Artwork According to Artwork's Location in Architectural Space (건축공간내 미술장식품의 설치위치에 따른 선정요인에 관한 연구)

  • 김남효
    • Korean Institute of Interior Design Journal
    • /
    • no.39
    • /
    • pp.20-27
    • /
    • 2003
  • The purpose of this study is to provide a practical guide for selecting architectural artwork and analyze relationship between artwork and interior space & facade. The problems with many outdoor artwork did not make the characteristics of the specific environment and did not form a big flow in the urban contextualism. Choosing the artwork, architectural environment for artwork is very much part of the designers' task. When artwork is to be specifically acquired for a particular projects, designer and client must work together to make choices and plan placement. The data are collected through evaluation surveys of college students and graduate students majoring in interior architecture & design, and analyzed by using SPSS-WIN program to find the major characterized factors. It is concluded that architectural artwork should be constituted with nine major factors of interior space - theme/scale, situation/contemporay accord, finished materials harmony, line/two-three dimensional form, proportion/rhythm, sequence, natural/artificial form, abstract/reality expression, originality - and eight major factors of facade - situation, abstract/reality expression, finished materials harmony, theme/sequence, natural/artificial form, proportion/rhythm, static/dynamic expression, originality/. contemporay accord.

Implant-assisted Removable Prosthetic Rehabilitation of a Patient with Crossed Occlusion

  • Oh, Hyun-Su;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • Journal of Korean Dental Science
    • /
    • v.14 no.1
    • /
    • pp.32-39
    • /
    • 2021
  • 'Crossed occlusion' is the condition in which occlusal intercuspation is lost when several teeth on upper and lower jaw remain. This report describes a clinical case in which a patient had two upper-left posterior teeth and two lower-right posterior teeth; typically known as left-right crossed occlusion. Considering the patient's general condition and financial situation, the treatment plan included placement of two implants on each jaw against the remaining teeth using surgical guide. To find out the ideal position of implants, digital diagnostic wax-up was preceded by superimposing the cast and cone beam computed tomography image, which was aided with radiographic stents. The consequent surveyed implant bridge provided stable vertical stop for fabrication of the implant assisted removable partial dentures. The patient was satisfied with the functionality and esthetics of definitive prosthesis.

The use of surgical guide stent for implant placement (임플란트 식립을 위한 수술 가이드의 사용)

  • Lee, Ji-Yeon;Yoon, Ji-Young;Oh, Namsik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.366-375
    • /
    • 2014
  • Surgical guide not only provide diagnosis and treatment plan, but even location and direction of implantation. Surgical guide could be divided into non-limited design, partially limited design, and completely limited design. Partially limited design is easily manufactured and inexpensive but less accuracy, compared to completely limited design. From this approach, partially limited design may be particularly effective in patients who present with a single missing tooth or partially edentulous teeth. Completely limited design is anatomically accuracy, esthetical and functional, optimized treatment for prosthetic and biomechanical perspective, and also minimizes discomfort for post-treatment. The purpose of this study is to review previous studies of various surgical guides and applying in clinic.

Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study

  • Beretta, Mario;Poli, Pier Paolo;Maiorana, Carlo
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.4
    • /
    • pp.184-193
    • /
    • 2014
  • Purpose: The aim of the present study was to evaluate the in vivo accuracy of flapless, computer-aided implant placement by comparing the three-dimensional (3D) position of planned and placed implants through an analysis of linear and angular deviations. Methods: Implant position was virtually planned using 3D planning software based on the functional and aesthetic requirements of the final restorations. Computer-aided design/computer-assisted manufacture technology was used to transfer the virtual plan to the surgical environment. The 3D position of the planned and placed implants, in terms of the linear deviations of the implant head and apex and the angular deviations of the implant axis, was compared by overlapping the pre- and postoperative computed tomography scans using dedicated software. Results: The comparison of 14 implants showed a mean linear deviation of the implant head of 0.56 mm (standard deviation [SD], 0.23), a mean linear deviation of the implant apex of 0.64 mm (SD, 0.29), and a mean angular deviation of the long axis of $2.42^{\circ}$ (SD, 1.02). Conclusions: In the present study, computer-aided flapless implant surgery seemed to provide several advantages to the clinicians as compared to the standard procedure; however, linear and angular deviations are to be expected. Therefore, accurate presurgical planning taking into account anatomical limitations and prosthetic demands is mandatory to ensure a predictable treatment, without incurring possible intra- and postoperative complications.

A Study on the Planning Strategy of Tenant Variety and Placement for Urban Entertainment Center (도심 쇼핑센터(UEC)의 테넌트 구성 및 배치계획에 관한 연구)

  • Lee, Hyun-Soo;Oh, Jung-Ah
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.2
    • /
    • pp.174-185
    • /
    • 2012
  • The purpose of this study is to suggest planning strategy of tenant mix for UEC based on the final result of tenant mix analysis of five different research cases. The following is the comprehensive explanation about the result of tenant mix planning strategy for UEC currently in operation and when planning a new facility. First, overall research cases in this study show the tendency of following an old tradition, which stresses direct sales focusing on retail and dining adaptation. In order to compensate the defect, it is suggested to adopt new type of tenants with the functional mix of retail and dining with entertainment rather than decreasing the proportion of retail and dining tenant and increasing it of entertainment tenant. Second, the floorplan of UEC should adopt racetrack or circuit form that can stimulate shoppers' circular movement so to expose them to as much tenants as possible. Service consumption mode related tenants are required to place on the side or the edge of UEC, while retail consumption mode related tenants should be planned in the center. Among dining consumption mode related tenants, impulse dining tenants like a coffee shop should be placed at the turning point or at the end of the pathway, destination tenants like a restaurant and a food court, on the other hand, is needed to be placed in the center of the space. In case of Entertainment related tenants, destination tenants like bookstore or multiplex should also be placed at the end of the pathway, and on the way to those tenants, it is required to place general tenants that can share target customers with them. On the contrary, game center or record shop like tenants that can stimulate impulse sales should be placed on the visitor's main move or near the other destination tenants. Third, anchor tenants play an important role in gathering people to the UEC, and then induce them to visit the other tenants that are located near the anchors. Thus it is suggested to plan to place general tenants on the same floor as anchor tenants are placed so they can share the characteristics of target customers which create synergy effect.

  • PDF

A torque-measuring micromotor provides operator independent measurements marking four different density areas in maxillae

  • Di Stefano, Danilo Alessio;Arosio, Paolo;Piattelli, Adriano;Perrotti, Vittoria;Iezzi, Giovanna
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.1
    • /
    • pp.51-55
    • /
    • 2015
  • PURPOSE. Bone density at implant placement site is a key factor to obtain the primary stability of the fixture, which, in turn, is a prognostic factor for osseointegration and long-term success of an implant supported rehabilitation. Recently, an implant motor with a bone density measurement probe has been introduced. The aim of the present study was to test the objectiveness of the bone densities registered by the implant motor regardless of the operator performing them. MATERIALS AND METHODS. A total of 3704 bone density measurements, performed by means of the implant motor, were registered by 39 operators at different implant sites during routine activity. Bone density measurements were grouped according to their distribution across the jaws. Specifically, four different areas were distinguished: a pre-antral (between teeth from first right maxillary premolar to first left maxillary premolar) and a sub-antral (more distally) zone in the maxilla, and an interforaminal (between and including teeth from first left mandibular premolar to first right mandibular premolar) and a retroforaminal (more distally) zone in the lower one. A statistical comparison was performed to check the inter-operators variability of the collected data. RESULTS. The device produced consistent and operator-independent bone density values at each tooth position, showing a reliable bone-density measurement. CONCLUSION. The implant motor demonstrated to be a helpful tool to properly plan implant placement and loading irrespective of the operator using it.

Prediction and Reduction of Alarm Sound Propagated through Elevator Shaft (엘리베이터 샤프트를 통한 경보음 전달 예측과 개선)

  • Jeong, Jeong-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.89-96
    • /
    • 2019
  • In this study, alarm sound generated as a priority alert system propagation through an elevator shaft in apartment buildings were simulated using room acoustic simulation software. The simulations were conducted on three kinds of elevator hall plan with a different number of elevators and placement. First, the elevator shaft without sound absorption material was simulated as a condition of the present. When the distance from the alarm sound generating floor became farther, alarm sound level was decreased. However, the alarm sound level three-floor distance was about 54 dB(A)~56 dB(A) which were louder than a background sound level of typical apartment buildings. Sound absorption material placement proposed by previous studies were simulated and the alarm sound levels were decreased about 12 dB~16 dB. These levels were similar or lower than the background level of apartment buildings. From these results, it can be concluded that placing sound absorption material on the surface of the elevator shaft wall can be one of the methods to control the alarm sound as regulated in NFSC.

A Study on the Eco-friendly Properties of Apartment Housing Playground in Germany (독일 공동주택 놀이터의 친환경적 특성 연구)

  • Kim, Ja Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.5
    • /
    • pp.87-98
    • /
    • 2015
  • As an apartment house as well as improving quality of life is becoming one of the brands, it is increasing the importance of the outer space with the facilities in the housing complex. In particular, the outdoor playground such as the community facilities that children and adults share as the activity areas for residents has received attention. However, actually children have not used many of Korean apartment housing playgrounds that were installed formally in the scrap area according to the housing plan by residential construction standards. it is considered necessary to improve the quality of the playground in housing complex and reform it in order to make the eco-friendly play space in which children can play safely and h healthily. As an alternative, we analyzed the eco-friendly properties of the playgrounds installed in the eco-friendly housing complex in Germany and derived the main planning elements of eco-friendly playground. In the observational survey of the 10 playgrounds in 9 housing complexes in 5 regions in Germany, we evaluated the environment-friendliness of these playgrounds in the 8 fields(location and placement, ecological environment, play space, play equipment and facilities, additional facilities, materials and resources, energy saving, environmental load reduction) according to the levels(suitable, partial reflection, unsuitable, non-reflection) of reflection of eco-friendly planning factors. The following is the summary of the results about the reflection of eco-friendly planning factors. In terms of "suitable": location and placement(88.8%), play equipment and facilities(73.5%), additional facilities(60.6%), environmental load reduction(54%), and ecological environment(50%) were higher than others. In terms of "unsuitable": there was nothing. In terms of "non-reflection": energy saving(95%), additional facilities(32.2%), and materials and resources(30.9%) were in order. Therefore, on the basis of these results, this study proposed the planning indicators to be considered first and the planning factors that should be complemented and improved in the construction of apartment housing playground in future.

Factors affecting maxillary sinus pneumatization following posterior maxillary tooth extraction

  • Lim, Hyun-Chang;Kim, Sangyup;Kim, Do-Hyup;Herr, Yeek;Chung, Jong-Hyuk;Shin, Seung-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.4
    • /
    • pp.285-295
    • /
    • 2021
  • Purpose: The aims of the present study were 1) to quantitatively evaluate the extent of sinus pneumatization and 2) to determine the factors affecting sinus pneumatization. Methods: Based on implant treatment records, a list of patients who underwent implant placement on the posterior maxilla was obtained. Among them, patients with pre-extraction and post-extraction (before implant placement) panoramic radiographs were selected. After excluding radiographs with low resolution and image distortion, the radiographs before and after extraction were superimposed using computer software. Subsequently, the extent of sinus pneumatization (the vertical change of the sinus floor) was measured. Simple and multiple mixed models were used to determine the factors affecting sinus pneumatization. Results: A total of 145 patients were eligible for the present investigation. The average extent of sinus pneumatization was 1.56±3.93 mm at 176 tooth sites. Male sex, single tooth extraction, extraction of an endodontically compromised tooth, a class I root-sinus relationship, and sinus membrane thickening >10 mm favored pneumatization, but without statistical significance. The maxillary second molar presented the greatest pneumatization (2.25±4.39 mm) compared with other tooth types. This finding was confirmed in the multiple mixed model, which demonstrated a statistically significant impact of the extraction of a second molar compared with the extraction of a first premolar. Conclusions: Maxillary sinus pneumatization was 1.56±3.93 mm on average. The extraction of a second molar led to the greatest extent of pneumatization, which should be considered in the treatment plan for this tooth site.