• Title/Summary/Keyword: Pixel Analysis

Search Result 703, Processing Time 0.027 seconds

Multi-stage Image Restoration for High Resolution Panchromatic Imagery (고해상도 범색 영상을 위한 다중 단계 영상 복원)

  • Lee, Sanghoon
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.6
    • /
    • pp.551-566
    • /
    • 2016
  • In the satellite remote sensing, the operational environment of the satellite sensor causes image degradation during the image acquisition. The degradation results in noise and blurring which badly affect identification and extraction of useful information in image data. Especially, the degradation gives bad influence in the analysis of images collected over the scene with complicate surface structure such as urban area. This study proposes a multi-stage image restoration to improve the accuracy of detailed analysis for the images collected over the complicate scene. The proposed method assumes a Gaussian additive noise, Markov random field of spatial continuity, and blurring proportional to the distance between the pixels. Point-Jacobian Iteration Maximum A Posteriori (PJI-MAP) estimation is employed to restore a degraded image. The multi-stage process includes the image segmentation performing region merging after pixel-linking. A dissimilarity coefficient combining homogeneity and contrast is proposed for image segmentation. In this study, the proposed method was quantitatively evaluated using simulation data and was also applied to the two panchromatic images of super-high resolution: Dubaisat-2 data of 1m resolution from LA, USA and KOMPSAT3 data of 0.7 m resolution from Daejeon in the Korean peninsula. The experimental results imply that it can improve analytical accuracy in the application of remote sensing high resolution panchromatic imagery.

Performance Analysis of Complex Phase-code for Phase Multiplexes Holographic Memory System (위상 다중화 홀로그래픽 메모리 시스템을 위한 CPC 위상코드의 성능 분석)

  • 조병철;김정진;김은수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.1C
    • /
    • pp.1-8
    • /
    • 2003
  • In this paper, performance of the CPC(complex phase code) which is recently proposed as a practical phase encoding method for phase-code multiplexes holographic memory system is comparatively analyzed with those of the conventional phase codes such as PR(pure random code), RCE(random code with equality), WHM(Walsh Hadamard Matrix). In computer simulation, the size of an address bean is fixed at 32$\times$32 pixels and 0%-25% phase-error ratio in a pixel are intentionally added to the real phase values to consider the nonlinear phase-modulation characteristics of the practical spatial light modulator. From comparative analysis of crosstalks and signal-to-noise ratios for these phase codes by calculating auto-correlation and cross-correlation, it is found that the CPC have the lowest cross-correlation mean value of 0.021, the lowest standard deviation of 0.0113 and the highest signal-to-noise ratio(SNR) of 27.4 among the four types of phase code. In addition, from the calculation of the number of all possible address beams for these four types of phase code as the size of the address beam is fixed to 3232 pixels, the CPC is found to have 6.334$\times$10$^{49}$ address beams, which are relatively higher number than that of the conventional phase codes.

Quality Analysis of GCP Chip Using Google Map (Google Map을 이용한 GCP 칩의 품질 분석)

  • Park, Hyeongjun;Son, Jong-Hwan;Shin, Jung-Il;Kweon, Ki-Eok;Kim, Taejung
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_1
    • /
    • pp.907-917
    • /
    • 2019
  • Recently, the demand for high-resolution satellite images increases in many fields such as land monitoring and terrain analysis. Therefore, the need for geometric correction is increasing. As an automatic precision geometric correction method, there is a method of automatically extracting the GCP by matching between the GCP Chip and the satellite image. For automatic precision geometric correction, the success rate of matching GCP Chip and satellite image is important. Therefore, it is important to evaluate the matching performance of the manufactured GCP Chip. In order to evaluate the matching performance of GCP Chips, a total of 3,812 GCP Chips in South Korea were used as experimental data. The GCP Chip matching results of KOMPSAT-3A and Google Map showed similar matching results. Therefore, we determined that Google Map satellite imagery could replace high-resolution satellite imagery. Also, presented a method using center point and error radius of Google Map to reduce the time required to verify matching performance. As a result, it is best to set the optimum error radius to 8.5m. Evaluated the matching performance of GCP Chips in South Korea using Google Maps. And verified matching result using presented method. As a result, the GCP Chip s in South Korea had a matching success rate of about 94%. Also, the main matching failure factors were analyzed by matching failure GCP Chips. As a result, Except for GCP Chips that need to be remanufactured, the remaining GCP Chips can be used for the automatic geometric correction of satellite images.

Dose and Image Assessment according to Radiologic Factors Variation at Digital Humerus X-ray Examination (디지털 환경에서 Humerus 검사 시 촬영인자 변화에 따른 선량 및 화질 평가)

  • Kim, Seong Min;Hong, Seon Sook;Lee, Kwan Sup;Ha, Dong Yun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose : We aim at presenting the optimum radiologic factor through the evaluation of dose variation and of image quality through the use of a grid in Humerus examination and the change of dose because of the change of radiologic factor. Materials and Methods : We divided it in 3 cases: when using a grid or not and when using IP(Image Plate) in a digital system. Also, as fixing kVp to 70kVp it changed mAs, and fixing mAs to 10 it changed kVp, we put up resolution chart and Burger rose phantom on the acrylic phantom of 7cm (the same level of Humerus) to evaluate the dose and image. We used Image J program to evaluate the quantitative resolution of the obtained image, and made the qualitative evaluation and statistical analysis of the image saved in PACS for 20 radiologic technologist with more than 10 years of experience in order of evaluate its contrast. We used SPSS10(SPSS Inc. Chicago, Illinois) for statistical analysis. Results : We observed the analytic result of resolution by the change of kVp that it was $4.539dGycm^2$ in 60kVp and $757.472dGycm^2$ in 75kVp, which increased about 64.6% of dose, while for the resolution it had the pixel value 30.7% better with 851 in 60kVp than 651 in 75kVp. Also, we analyzed the result of resolution by the change of mAs that it was $3.106dGycm^2$ in 5mAs, and $12.470dGycm^2$ in 20mAs, which increased about 400% of dose, while for the resolution DR had 678 in 5mAs, and 724 in 20mAs that increased about 6.8% of resolution. We made the qualitative evaluation of contrast by the change of kVp that DR showed the higher quality than CR, but the contrast by the change of kVp had no special different at the moment of visual evaluation, nor statistically significant difference(P>0.05). We observed the qualitative evaluation of contraste by the change of mAs that the contrast increased as DR increased mAs, and had statistically significant difference(P<0.05). On the other hand, CR had no significant difference for more than 10mAs nor statistically significant difference(P>0.05). Conclusion : In case of some patients with radiographic exposure by the repeated examination such as emergent patient or Follow up patient, they are considered to try to limit the use of a grid, to set kVp under 65kVp in fixed mode, to select less than 10mAs and to reduce the possibility of patient being bombed.

  • PDF

Detection of Forest Fire and NBR Mis-classified Pixel Using Multi-temporal Sentinel-2A Images (다시기 Sentinel-2A 영상을 활용한 산불피해 변화탐지 및 NBR 오분류 픽셀 탐지)

  • Youn, Hyoungjin;Jeong, Jongchul
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_2
    • /
    • pp.1107-1115
    • /
    • 2019
  • Satellite data play a major role in supporting knowledge about forest fire by delivering rapid information to map areas damaged. This study, we used 7 Sentinel-2A images to detect change area in forests of Sokcho on April 4, 2019. The process of classify forest fire severity used 7 levels from Sentinel-2A dNBR(differenced Normalized Burn Ratio). In the process of classifying forest fire damage areas, the study selected three areas with high regrowth of vegetation level and conducted a detailed spatial analysis of the areas concerned. The results of dNBR analysis, regrowth of coniferous forest was greater than broad-leaf forest, but NDVI showed the lowest level of vegetation. This is the error of dNBR classification of dNBR. The results of dNBR time series, an area of forest fire damage decreased to a large extent between April 20th and May 3rd. This is an example of the regrowth by developing rare-plants and recovering broad-leaf plants vegetation. The results showed that change area was detected through the change detection of danage area by forest category and the classification errors of the coniferous forest were reached through the comparison of NDVI and dNBR. Therefore, the need to improve the precision Korean forest fire damage rating table accompanied by field investigations was suggested during the image classification process through dNBR.

Image Evaluation by Metallic Hip Prosthesis in Computed Tomography Examination (컴퓨터단층촬영검사에서 고관절 삽입물에 의한 영상평가)

  • Min, Byung-In;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.281-288
    • /
    • 2022
  • In this study, four algorithms (Soft, Standard, Detail, Bone) were used for general CT scan (Before MAR) images and MAR (After MAR) images for patients with metal implants inserted into the hip joint. was applied to compare and analyze Noise, SNR, and CNR to find out the optimal algorithm for quantitative evaluation. As the analysis method, Image J program, which can calculate image analysis and area and pixel values on the image reconstructed with four algorithms, was used. In order to obtain Noise, SNR, and CNR, the HU mean value and HU SD value were obtained by designating the bone (ischium) closest to the metal implant in the image for the measurement site, and the background noise was the surrounding muscle. The region of interest (ROI) was equally designated as 15 × 15 mm in consideration of the size of the bone, and the values of SNR and CNR were calculated according to the given equation. As a result, for noise, After MAR and Soft algorithms showed the lowest noise, and SNR and CNR showed the highest for Before MAR and Soft algorithms. Therefore, the soft algorithm is judged to be the most appropriate algorithm for metal implant hip joint CT.

Analysis and Orange Utilization of Training Data and Basic Artificial Neural Network Development Results of Non-majors (비전공자 학부생의 훈련데이터와 기초 인공신경망 개발 결과 분석 및 Orange 활용)

  • Kyeong Hur
    • Journal of Practical Engineering Education
    • /
    • v.15 no.2
    • /
    • pp.381-388
    • /
    • 2023
  • Through artificial neural network education using spreadsheets, non-major undergraduate students can understand the operation principle of artificial neural networks and develop their own artificial neural network software. Here, training of the operation principle of artificial neural networks starts with the generation of training data and the assignment of correct answer labels. Then, the output value calculated from the firing and activation function of the artificial neuron, the parameters of the input layer, hidden layer, and output layer is learned. Finally, learning the process of calculating the error between the correct label of each initially defined training data and the output value calculated by the artificial neural network, and learning the process of calculating the parameters of the input layer, hidden layer, and output layer that minimize the total sum of squared errors. Training on the operation principles of artificial neural networks using a spreadsheet was conducted for undergraduate non-major students. And image training data and basic artificial neural network development results were collected. In this paper, we analyzed the results of collecting two types of training data and the corresponding artificial neural network SW with small 12-pixel images, and presented methods and execution results of using the collected training data for Orange machine learning model learning and analysis tools.

Analysis of Color Characteristics of Marine Oil Spills Using PlanetScope Images (PlanetScope 영상을 이용한 해양 유출유의 색상 특성 분석)

  • Jonggu Kang;Youjeong Youn;Seoyeon Kim;Yemin Jeong;Soyeon Choi;Yungyo Im;Youngmin Seo;Yangwon Lee
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_2
    • /
    • pp.875-883
    • /
    • 2023
  • In this letter, we used PlanetScope imagery to conduct experiments on the color characteristics for oil type classification of marine oil spills through Red-Green-Blue (RGB) histogram analysis. The histograms of marine oil spills can be divided into three categories (dark black tones, light silver tones, and light rainbow tones) according to the distribution of pixel values in each band. Thick oil layers with dark black tones can be classified as heavy oil, while thin oil layers with light silver and rainbow tones can be classified as light oil. As more images are analyzed in the future, these oil spill detection and classification methods will become more generalized and reliable.

Usefulness of Hepatocellular Carcinoma by Hepatic Arterial Perfusion Scintigraphy with $^{99m}Tc$-MAA ($^{99m}Tc$-MAA를 이용한 간세포암의 간동맥 관류 스캔의 유용성)

  • Jeong, Ji-Uk;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Moo-Seok;Song, Hyeon-Seok;Park, Se-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.155-158
    • /
    • 2010
  • Purpose: $^{99m}Tc$-macroaggregated albumin (MAA) hepatic arterial perfusion scintigraphy was known for useful method to evaluate patients receiving intraarterial chemotherapy for liver cancer. This study evaluate about usefulness of normal liver on hepatocellular carcinoma (HCC) from HCC patients. This study is to see the usefullness of Hepatic Arterial Perfusion Scintigraphy (HAPS) by measuring mass size, shape, lung shunting and tumor to normal ratio (T/N ratio) in relative blood stream of HCC patients compared with HCC on normal liver. Materials and Methods: From June 2009 to September 2009, HAPS studies were performed on 7 patients (men 6, women 1, mean 64) who were diagnosed HCC. HAPS was performed after proper hepatic artery $^{99m}Tc$-MAA of 5 mCi (185 MBq) injection by catheter. We performed anterior, posterior, both lateral view, SPECT of chest and abdomen. Then we set up ROI and calculated lung shunting, T/N ratio for each count, count/pixel (mean value). Results: Tumor and liver size analyzed by ROI of anterior, posterior view are 2.0-10.8 cm (mean 3.75 cm), 8.8-18.5 cm (mean 14.6 cm). T/N ratio analyzed by total tumor and total normal mean value are 2.41-5.76 (mean 3.8). lung shunting analyzed by total liver count is 3.14-13.92% (mean 6.77%). Conclusion: HAPS with $^{99m}Tc$-MAA can evaluate mass size, location, quantitative analysis through T/N ratio. also HAPS can evaluate detection of arteriovenous shunt through lung uptake before radioisotope therapy. Therefore HAPS with $^{99m}Tc$-MAA can be useful method in aspect of evaluation and treatment of HCC.

  • PDF

Analysis of Contrast Medium Dilution Rate for changes in Tube Current and SOD, which are Parameters of Lower Limb Angiography Examination (하지 혈관조영검사 시 매개변수인 관전류와 SOD에 변화에 대한 조영제 희석률 분석)

  • Kong, Chang gi;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.603-612
    • /
    • 2020
  • This study has a purpose to look into the effect of the relationship between the Tube current (mA) and SOD(Source to Object Distance), which is a parameter of lower limb angiography examination, and the dilution rate of the contrast medium concentration (300, 320, 350) on the image. To that end, using 3 mm vessel model water phantom, a vessel model custom made in the size of peripheral vessel diameter, this study measured relationships between change of parameters, such as tube current (mA), SOD and varying concentrations (300, 320, 350) of contrast medium dilution into SNR and CNR values while analyzing the coefficients of variance(cv<10). The software used to measure SNR and CNR values was Image J 1.50i from NIH (National Institutes of Health, USA). MPV (mean pixel value) and SD (standard deviation) were used after verifying numerically the image signal for region of interest (ROI) and background on phantom from the DICOM (digital imaging and communications in medicine) 3.0 file transmitted to PACS. As to contrast medium dilution by the change of tube current, when 146 mA and 102 mA were compared, For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 22.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 12.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As a result, set a low tube current value in other tests or procedures including peripheral angiography of the lower extremities in the intervention, and make the table as close as possible to the image receiver, and adjust the contrast agent concentration (300) to CM: N/S dilution (30%: 70%). ) Is suggested as the most efficient way to obtain images with an appropriate concentration while simultaneously reducing the burden on the kidney and the burden on exposure.