• Title/Summary/Keyword: Pitot Probe

Search Result 22, Processing Time 0.015 seconds

An Experimental Study of Test Section Velocity Calibration for Low-Speed Wind Tunnel (저속풍동 시험부 속도교정에 관한 실험적 연구)

  • Oh, Se-Yoon;Lee, Jong-Geon;Kim, Sung-Cheol;Kim, Sang-Ho;Ahn, Seung-Ki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.3
    • /
    • pp.230-236
    • /
    • 2012
  • The purpose of this research is to determine the calibration constants of the wind speed measurement systems required to calculate the wind tunnel velocity in the test section. In the present work, the aerodynamic calibration tests of the test section were conducted in the Agency for Defense Development's Low-Speed Wind Tunnel. The test speed ranged from 10 to 100 m/s with a reference pitot-static pressure probe. The validity of the calibration results was evaluated by comparing them with the previous calibration constants. The calibration results show that fair to good agreement is obtained with resonable accuracy.

Instrumentation for Performance Test of Turbo Compressor (터보 압축기 성능시험을 위한 계측기기 선정)

  • Park, Tae-Choon;Kang, Young-Seok;Yang, Soo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.46-52
    • /
    • 2008
  • The instrumentation was studied in order to measure aerodynamic performance and efficiency of a compressor as a component of a 5MW-class gas turbine for power generation. In case of an axial compressor, the distributions of static pressure on a casing can be obtained by averaging at each stage and those of total pressure and temperature in the flow field of the compressor can be measured with a Kiel temperature probe. In case of a centrifugal compressor, the static pressures at the hub and the tip, respectively, of an impeller exit are considerably different, so the pressures need to be measured at both positions and thereafter averaged. The distributions of static pressures in a diffuser and a deswirler are measured at ten positions along five streamlines in one pitch. In addition the flow field can be measured in detail by 5-hole Pitot tube in order to analyze the flow characteristics of the core flow region and wake region and the rotor-stator interaction of the compressor.

  • PDF