• 제목/요약/키워드: Piping support

검색결과 76건 처리시간 0.022초

스트레인게이지를 활용한 발전소 터빈 및 주증기 배관의 열팽창 측정 (Thermal Expansion Measurement of Turbine and Main Steam Piping by Using Strain Gages in Power Plants)

  • 나상수;정재원;봉석근;전동기;김윤석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.886-891
    • /
    • 2000
  • One of the domestic co-generation plants have undergone excessive vibration problems of turbine attributed to external force for years. The root cause of turbine vibration may be shan alignment problem which sometimes is changed by thermal expansion and external farce, even if turbine technicians perfectly performed it. To evaluate the alignment condition from plant start-up to full load, a strain measurement of turbine and main steam piping subjected to thermal loading is monitored by using strain gages. The strain gages are bonded on both bearing housing adjusting bolts and pipe stoppers which. installed in the x-direction of left-side main steam piping near the turbine inlet in order to monitor closely the effect of turbine under thermal deformation of turbine casing and main steam piping during plant full load. Also in situ load of constant support hangers in main steam piping system is measured by strain gages and its results are used to rebalance the hanger rod load. Consequently, the experimental stress analysis by using strain gages turns out to be very useful tool to diagnose the trouble and failures of not only to stationary components but to rotating machinery in power plants.

  • PDF

화력발전소 발전기 냉각용 수소배관계 과도진동 개선 (Reduction of Transient Vibration on $H_2$ Piping System for Generator Cooling in a Power Plant)

  • Yang Kyeong Hyeon;Kim Sung Hwi;Cho Chul Whan;Bae Chun Hee
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.360.2-360
    • /
    • 2002
  • There was the transient vibration on $H_2$ piping system fer cooling the generator in a power plant. We found it was resulted from resonance between the natural vibration of the piping system and exciting force from the turbine rotor by measurement and simulation test. We verified it would be changed the mode shape of the piping system by several simulation test for the structural modification of the piping system. (omitted)

  • PDF

발전용 고온 배관의 점검 및 실시간 변위감시 기술 (Technology of Inspection and Real-time Displacement Monitoring on Critical Pipe for Power Plant)

  • 현중섭;허재실;조선영;허정열;이성기
    • 대한기계학회논문집A
    • /
    • 제33권10호
    • /
    • pp.1177-1186
    • /
    • 2009
  • High temperature steam pipes of thermal power plant are subject to a severe thermal range and usually operates well into the creep range. Cyclic operation of the plant subjects the piping system to mechanical and thermal fatigue damages. Also, poor or malfunctional supports can impose massive loads or stress onto the piping system. In order to prevent the serious damage and failure of the critical piping system, various inspection methods such as visual inspection, computational analysis and on-line piping displacement monitoring were developed. 3-dimensional piping displacement monitoring system was developed with using the aluminum alloy rod and rotary encoder sensors, this system was installed and operated on the high temperature steam piping of "Y" thermal power plant successfully. It is expected that this study will contribute to the safety of piping system, which could minimize stress and extend the actual life of critical piping.

FUZZY SUPPORT VECTOR REGRESSION MODEL FOR THE CALCULATION OF THE COLLAPSE MOMENT FOR WALL-THINNED PIPES

  • Yang, Heon-Young;Na, Man-Gyun;Kim, Jin-Weon
    • Nuclear Engineering and Technology
    • /
    • 제40권7호
    • /
    • pp.607-614
    • /
    • 2008
  • Since pipes with wall-thinning defects can collapse at fluid pressure that are lower than expected, the collapse moment of wall-thinned pipes should be determined accurately for the safety of nuclear power plants. Wall-thinning defects, which are mostly found in pipe bends and elbows, are mainly caused by flow-accelerated corrosion. This lowers the failure pressure, load-carrying capacity, deformation ability, and fatigue resistance of pipe bends and elbows. This paper offers a support vector regression (SVR) model further enhanced with a fuzzy algorithm for calculation of the collapse moment and for evaluating the integrity of wall-thinned piping systems. The fuzzy support vector regression (FSVR) model is applied to numerical data obtained from finite element analyses of piping systems with wall-thinning defects. In this paper, three FSVR models are developed, respectively, for three data sets divided into extrados, intrados, and crown defects corresponding to three different defect locations. It is known that FSVR models are sufficiently accurate for an integrity evaluation of piping systems from laser or ultrasonic measurements of wall-thinning defects.

원자로 냉각재배관 엘보우 및 서포트 스컷트용 (Fracture Resistance Characteristics of SA516-Gr.70 Steel Plate for RCS Piping Elbow and Support Skirt)

  • 손종동;임만배
    • 한국안전학회지
    • /
    • 제21권4호
    • /
    • pp.49-54
    • /
    • 2006
  • The evaluation of elastic-plastic fracture characteristic was investigated in ferrite steel SA 516- Gr70 used for reactor coolant piping elbow and support skirt of pressure vessels. This paper describes the effect of temperature on J-R curve characteristic of this material. The elastic-plastic fracture mechanics parameter J is obtained with unloading compliance method. The test method were analyzed according to ASTM E 813-89 and E 1152-89. Unloading compliance $J_{IC}$ tests were performed on 1 CT specimens at varied temperatures from $25^{\circ}C$ to about $400^{\circ}C$ using a high temperature extensometer. At all temperature, valid $J_{IC}$ measurements could be made and $J_{IC}$ decreased with increasing temperature. SEM fractography schematically illustrates microvoid initiation, growth and coalescence at the tip of a preexisting crack.

Development for Life Assessment System for Pipes of Thermal Power Plants

  • Hyun, Jung-Seob;Heo, Jae-Sil;Kim, Doo-Young;Park, Min-Gyu
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권4호
    • /
    • pp.583-588
    • /
    • 2016
  • The high-temperature steam pipes of thermal power plants are subjected to severe conditions such as creep and fatigue due to the power plant frequently being started up and shut down. To prevent critical pipes from serious damage and possible failure, inspection methods such as computational analysis and online piping displacement monitoring have been developed. However, these methods are limited in that they cannot determine the life consumption rate of a critical pipe precisely. Therefore, we set out to develop a life assessment system, based on a three-dimensional piping displacement monitoring system, which is capable of evaluating the life consumption rate of a critical pipe. This system was installed at the "M" thermal power plant in Malaysia, and was shown to operate well in practice. The results of this study are expected to contribute to the increase safety of piping systems by minimizing stress and extending the actual life of critical piping.

Thermal stress analysis for high pressure and temperature pipelines in ultra steam turbine (UST) system

  • 최대건
    • 대한조선학회지
    • /
    • 제52권2호
    • /
    • pp.19-24
    • /
    • 2015
  • A reliable assessment and analysis of the condition of high pressure and temperature steam pipelines requires defining stress state, which will take into consideration not just the impact of internal pressure and temperature but all applied loads. For that, usage of modeling and numerical methods for calculation and analysis of stress state is essential. The main aim of piping stress analysis is to check the design of piping layout, which will allow simple, efficient and economical piping supports and provide flexibility to the piping system for loads and stresses. The piping stress analysis is carried out using CAESER II software. By using this software we can evaluate stresses, stress ratios, flange condition, support loads, element forces and displacements at each node and points. In this paper, only the maximum and minimum displacement results are tabulated, which is also shown in detail by an example of main steam pipelines of UST Main Engine System [1].

부생가스 연료배관의 설계변경에 따른 안전성 평가 (Safety Assessment of By-product Gas Piping after Design Change)

  • 윤기봉;응웬반장;위엔두안선;정성용;이주영;김지윤
    • 한국가스학회지
    • /
    • 제17권2호
    • /
    • pp.50-58
    • /
    • 2013
  • 공정플랜트에는 다양한 배관이 고압, 고온의 인화성, 폭발성 물질을 이송하고 있다. 잦은 설계 변경 및 증설 등으로 복잡한 형상으로 배관이 형성되어 있는 경우가 많으나 배관의 구조가 단순하여 실제 위험성에 비해 안전 관리가 부족한 경우가 많다. 본 연구에서는 국내 한 업체에서 부생가스를 연료로 사용하던 배관을 설계 변경하여 천연가스와 혼합하여 사용하도록 사례를 활용하여, 배관의 안전성을 평가 하는 방법을 예시하였다. 배관의 설계 변경 후 안전성을 ASME 기준에 따라 재평가하고, 배관의 주요 관리부위를 결정하는 방법을 제시하였다. 배관의 분기 및 루프 등이 다수 복잡하게 연결되어있는 가스혼합용 믹싱드럼 배관 시스템을 대상으로 해석하였다. 배관의 주요부위 응력 민감도를 이해하기 위해 배관의 지지대 구속조건 및 외부 온도를 변화시켜 가면서 이들의 영향을 연구하였다. 또한 부생가스가 포함하고 있는 수소가스에 의한 손상 가능성에 대해서도 논의하였다.

유동식 그루브 조인트로 연결된 엘보 요소의 한계상태 평가 (Limit State Evaluation of Elbow Components Connected with Flexible Groove Joints)

  • 김성완;윤다운;전법규;박동욱;장성진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제28권3호
    • /
    • pp.91-99
    • /
    • 2024
  • 배관시스템은 다양한 산업 분야에서 이용되는 중요한 설비이며 생활 및 안전과 관련된 영역에서 사용되고 있다. 배관시스템은 건축물 및 시설의 주요 구조부에 고정되어 있으나 외부 하중을 지지하지 않으며 주어진 고유기능을 수행하는 비구조요소이다. 지진하중으로 인한 배관시스템은 두 지지점 사이의 서로 다른 거동으로 발생하는 위상차로 인한 상대 변위의 영향을 받으며 변위 지배적인 반복거동 때문에 손상이 발생할 가능성이 있다. 배관시스템에서 피팅과 조인트는 지진하중에 취약한 대표적인 요소이다. 배관시스템의 피팅과 조인트에 대한 내진성능과 한계상태를 평가하고자 한다면 상대변위를 모사하기 위한 높은 스트로크를 가지는 엑츄에이터가 필요하나 실험을 수행할 수 있는 설비가 많지 않아 어려움이 있다. 따라서 피팅과 조인트로 연결된 배관시스템의 내진성능과 한계상태를 평가하기 위해서는 요소 단위의 실험이 필요하다. 이 연구에서는 수직배관시스템에서 지진하중에 취약한 요소인 피팅과 조인트를 포함하는 엘보 시험체에 대하여 내진성능을 평가하는 방법을 제시하였다. 엘보 시험체는 90° 배관 엘보의 양단에 직관부를 유동식 그루브 조인트를 이용하여 연결하였다. 엘보 시험체에 대하여 변형각에 기반을 둔 주기하중 프로토콜을 이용하여 내진성능을 평가하였다. 평가된 내진성능에 대한 여유도를 확인하기 위하여 일정한 진폭에 대한 주기하중을 적용하여 한계상태를 평가하였다.

도시가스 매설이중배관 건전성 향상에 관한 실험적 연구 (An Experimental Study on the Improvement of City Gas Buried Double Piping Integrity)

  • 임형덕
    • 한국산업융합학회 논문집
    • /
    • 제23권5호
    • /
    • pp.757-763
    • /
    • 2020
  • City gas buried pipes are managed by corrosion protection to prevent corrosion. In the case of the press-in section, the double pipe and the main pipe may cause corrosion under the influence of stray current, which can shorten the life of the pipes. In addition, if the insulator is filled in the press-in section, the press-in section itself is a single structure, and can be directly affected by external impact, and when the surrounding ground subsidence occurs, the stress may be concentrated, resulting in serious consequences. In this study, a serration-type shock absorber in the form of a sliding support was proposed as a new buried double piping construction method using EPS. The serration-type shock absorber can contribute to the improvement of the integrity of the buried double piping, as it can utilize the gas piping's own ductility and stress distribution characteristics with proper anti-corrosion management and shock-absorbing material properties by preventing contact inside the buried double pipe. However, for application to ground piping, there remains a task to supplement the vulnerability against fire due to the characteristics of EPS materials.