• Title/Summary/Keyword: Pipeline leakage

Search Result 131, Processing Time 0.03 seconds

Efficient Leakage Estimation of Public Agriculture Groundwater in Jeju Island (제주도 공공 농업용 지하수의 효율적 누수량 산정 연구)

  • Kim, MinChul;Park, WonBae;Kang, BongRae;Kim, JiMyung
    • Journal of Soil and Groundwater Environment
    • /
    • v.25 no.3
    • /
    • pp.1-11
    • /
    • 2020
  • In this study, leakage ratios of Jeju Island's public agricultural groundwater were calculated by utilizing field measurements of groundwater level and surface reservoir water level. The average leakage ratios were 75.6% at groundwater well A and 57.5% at well B, with the ratio inversely proportional to agricultural water usage. The level of agricultural reservoirs varied at constant intervals at night, and the amount of water leakage associated with the variation was estimated as 0.1 - 16.3 ㎥/h. The leakage ratio was also influenced by pipeline length, average slope, and number of farmhouses. Currently, the estimation of agricultural water leakage on Jeju Island is based upon field inspection which is very labor- and cost intensive. The leakage ratio estimated by monitoring the reservoirs associated with the well A and B were 73.3 and 54.7%, respectively, consistent with the values obtained by field measurements.

Leakage Effect on the Exit Pressure in a Gas Pipeline (가스 파이프라인 내의 누출 현상이 출구 압력에 미치는 영향에 대한 연구)

  • Chang Seung-Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.27-33
    • /
    • 2006
  • This paper investigates leak effect on the outlet pressure at pipeline exit. A modified Weymouth equation(including inclination effect) was used for this study. To investigate leak effect, outlet pressure and ratio of outlet to inlet pressure were compared between no leak and leak conditions for horizontal, upward and downward flows, respectively. Then, effects of leak location as well as leak rate on the outlet pressure were also investigated for all pipeline inclinations.

  • PDF

Soil Breakdown Test using Fixture (Fixture를 이용한 토양 절연파괴 실험)

  • Lee, H.G.;Ha, T.H.;Jung, D.H.;Ha, Y.C.;Kim, D.K.;Bae, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.384-385
    • /
    • 2007
  • The fault current through the earth originated from a power line ground fault might cause arcing through the soil to an adjacent pipeline, which might bring about not only a catastrophic accident such as gas explosion and oil leakage but also a hazard to the safety of workers responsible for the maintenance and repair of the pipeline. In this paper we experimented on the soil breakdown test using the fixture and outlined the standards for the separation distance of a buried pipeline adjacent to the power line tower.

  • PDF

The TRS Terminal for Wireless Remote Corrosion Monitoring System (무선 원격 부식모니터링용 TRS 단말기)

  • Ha, Tae-Hyeon;Bae, Jeong-Hyo;Lee, Hyeon-Gu;Ha, Yun-Cheol;Kim, Dae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.544-547
    • /
    • 2003
  • The owner of water pipeline has a burden of responsibility for the protection of corrosion and the prevention against leakage of water. So, they have been installed a CP(Cathodic Protection) System in odor to protect corrosion. And they also have been measured and analyzed the data about P/S(Pipe to Soil) potential of water pipeline. The P/S potential is basic data of evaluation for water pipeline corrosion. They need remote automatic corrosion monitoring system for easy maintenance. In this paper, The communication method was studied mainly. And the specifications of proposed TRS (Truncked Radio System ) terminal for corrosion monitoring are introduced briefly.

  • PDF

A Computationally Efficient Retina Detection and Enhancement Image Processing Pipeline for Smartphone-Captured Fundus Images

  • Elloumi, Yaroub;Akil, Mohamed;Kehtarnavaz, Nasser
    • Journal of Multimedia Information System
    • /
    • v.5 no.2
    • /
    • pp.79-82
    • /
    • 2018
  • Due to the handheld holding of smartphones and the presence of light leakage and non-balanced contrast, the detection of the retina area in smartphone-captured fundus images is more challenging than retinography-captured fundus images. This paper presents a computationally efficient image processing pipeline in order to detect and enhance the retina area in smartphone-captured fundus images. The developed pipeline consists of five image processing components, namely point spread function parameter estimation, deconvolution, contrast balancing, circular Hough transform, and retina area extraction. The results obtained indicate a typical fundus image captured by a smartphone through a D-EYE lens is processed in 1 second.

Development of TDR-based Water Leak Detection Sensor for Seawater Pipeline of Ship (시간영역반사계를 이용한 해수배관시스템의 누수 탐지용 센서 개발 연구)

  • Hwang, Hyun-Kyu;Shin, Dong-Ho;Kim, Heon-Hui;Lee, Jung-Hyung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.6
    • /
    • pp.1044-1053
    • /
    • 2022
  • Time domain reflectometry (TDR) is a diagnostic technique to evaluate the physical integrity of cable and finds application in leak detection and localization of piping system. In this study, a cable-shaped leak detection sensor was proposed using the TDR technique for monitoring leakage detection of ship's engine room seawater piping system. The cable sensor was developed using a twisted pair arrangement and wound by an absorbent material. The availability and performance of the sensor for leak detection and localization were evaluated on a lab-scale pipeline set up. The developed sensor was installed onto the pipes and flanges of the lab-scale set up and various TDR waveforms were acquired and analyzed according to the dif erent variables including the number of twists and sheath thickness. The result indicated that the twisted cable sensor was able to produce clear and smooth signal as compared to the TDR sensor with a parallel arrangement. The optimal number of twist was determined to be above 10 per the unit length. The optimal diameter of sheath thickness that results in the desired sensitivity was determined to be ranging from 80% up to 120% of the diameter of the conductor. The linear regression analysis for estimation of leak localization was carried out to estimate the location of the leakage, and the result was a determination coefficient of 0.9998, indicating a positive relationship with the actual leakage point. The proposed TDR based leak detection method appears to be an effective method for monitoring leakage of ship's seawater piping system.

Evaluation of Corrosion Characteristics on Welding Part of Leakage Water Pipe by Underwater Welding Electrode (수중용접봉으로 용접한 누수 배관 용접부위의 부식 특성 평가)

  • Kim, Jin-Gyeong;Moon, Kyung-Man
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.93-94
    • /
    • 2006
  • The repair welding of small leakage parts on the water pipeline in engine room is often and important factor in standby and emergency condition in a ship. So, the purpose of this study is to evaluate the corrosion characteristics of welding part of leakage water pipe in case of some underwater welding electrodes. The corrosion current density between welding metal and base metal was considerably different according to used underwater welding electrodes. In case of DC welding, its corrosion characteristics was better than that of AC welding.

  • PDF

Effect of Ear and Near-side Single Circular Pit Depth and Bulk Stress on Magnetic Flux Leakage at ferromagnetic Pipeline (강자성 배관 외.내부 면의 단일 원형 홈의 깊이와 부피응력이 누설자속에 미치는 영향)

  • Ryu, Kwon-Sang;Park, Young-Tae;Atherton, D.L.;Clapham, L.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.3
    • /
    • pp.263-269
    • /
    • 2003
  • Magnetic flux leakage (MFL) signals were used for corrosion inspection of buried oil and gas pipeline. 3D finite element analysis was used to examine the effects of far and near-side pit depth and tensile stress on MFL signals. Anisotropci materials were used, and the effects of simulated tensile stress on MFL were investigated. The axial and radial MFL signals depended on far and near-side single pit depth and on the bulk stress, but the circumferential MFL signal did not depend on them. The axial and radial MFL signals increased with increasing pit depth and the bulk stress, but the circumferential MFL signal was scarcely changed.

A Study on the Measurement of Axial Cracks in the Magnetic Flux Leakage NDT System (자기누설 비파괴 검사 시스템에서 축방향 미소결함 측정에 관한 연구)

  • Kim, Hui-Min;Park, Gwan-Soo;Rho, Yong-Woo;Yoo, Hui-Ryong;Cho, Sung-Ho;Kim, Dong-Kyu;Koo, Sung-Ja
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.2
    • /
    • pp.49-57
    • /
    • 2012
  • From among the NDT (Non-Destructive Testing) methods, the MFL (Magnetic Flux Leakage) PIG (Pipeline Inspection Gauge) is especially suitable for testing pipelines because the pipeline has high magnetic permeability. MFL PIG showed high performance in detecting the metal loss and corrosions. However, MFL PIG is difficult to detect the crack which occured by exterior-interior pressure difference in pipelines and the shape of crack is very long and narrow. Therefore, the new PIG is needed to be researched and developed for detecting the cracks. The CMFL (Circumferential MF) PIG performs magnetic fields circumferentially and can maximize the magnetic flux leakage at the cracks. In this paper, CMFL PIG is designed and the distribution of the magnetic fields is analyzed by using 3 dimensional nonlinear finite element method (FEM). By Simulating and Measuring the magnetic leakage field, it is possible to detect of axial cracks in the pipeline.

DCT based Magnetic Flux Leakage Analysis for Defect Feature Extraction of Gas Pipelines (DCT 기반의 자기 누설 신호 분석을 통한 가스 배관에서의 결함 신호 특징 추출)

  • Han, Byung-Gil;Park, Gwan-Soo;Yoo, Hui-Ryong;Rho, Young-Woo;Choi, Doo-Hyun
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.359-360
    • /
    • 2006
  • Magnetic Flux Leakage (MFL) methods are widely employed for the non-destructive testing of gas pipelines. In the application of MFL pipeline inspection technology, corrosion anomalies are detected and identified via their leakage filed due to changes in wall thickness. This paper presents discrete cosine transform (DCT) based MFL signal analysis for defect feature extraction of natural gas pipelines. The original MFL signals are transformed into new ones based on the analysis. The usefulness of the approach has been shown by the experimental results.

  • PDF