• Title/Summary/Keyword: Pipe diameter

검색결과 799건 처리시간 0.029초

관재료 및 피복재료별 농경지 암거배수 효과 분석 (Analyses of subsurface drainage effects of farmland with respect to pipe and envelop material)

  • 정상옥
    • 한국농공학회지
    • /
    • 제37권5호
    • /
    • pp.53-61
    • /
    • 1995
  • Analyses of subsurface drainage effects of farmland with respect to pipe and envelop material are made by the laboratory experiments using soil box to give basic information for the subsurface drainage system planning and design. Three different diameter PVC perforated pipes and a mesh pipe are used with envelop materials such as sand, rice bran, and crushed stone. Steady state subsurface drainage flow rate increased as envelop material changed from sand to rice bran and crushed stone. This indicates that as the hydraulic conductivity of the envelop material increases, the drainage flow rate increases. On the other hand, for a given envelop material, the mesh pipe which has the largest openning area shows the largest flow rate while small diameter PVC pipes show small flow rates. This tells that as the openning area and pipe diameter increase, the flow rate increases, too. Therefore, selection of pipe and envelop material should be made in accordance with the design drainage flow rate. Unsteady state subsurface drainage flow rate with respect to time differs for different envelop material. In case the sand was used as an envelop material, the small diameter PVC pipes show larger flow rates than the large diameter PVC pipe and mesh pipe. When the rice bran was used, the mesh pipe shows the largest flow rate, while small diameter pipes show smaller flow rates. In case the crushed stone was used as an envelop material, the large diameter PVC pipe and mesh pipe show larger flow rates, while small diameter pipes show a little bit smaller flow rates. However, the variation of flow rates among different pipes is the smallest when the crushed stone is used. The flow rate curve with respect to the pipe changes little for the crushed stone envelop which has a large hydraulic conductivity, while that changes much for the sand and rice bran envelops. However, it is difficult to draw a consistent relationship between the drainage flow rate and pipe for all the envelop materials. Since the subsurface drainage experiments are made only under the restricted laboratory condition in this study, further study including field experiment is required.

  • PDF

Explicit Design of Uniformly Rough Pipe

  • Yoo, Dong-Hoon
    • Korean Journal of Hydrosciences
    • /
    • 제7권
    • /
    • pp.107-124
    • /
    • 1996
  • Pipe design normally requires pump power, discharge or pipe diameter for each condition given. Due to several investigators the pipe friction factor con now be estimated by explicit way for a wide range of flow condition. In various problems of pipe design, however, the flow condition cannot be pre-determined even for a uniformly rough pipe. In these cases a lot of iterations are often required to have an accurate solution with ordinary approach. This paper presents the direct computation method of discharge and pipe diameter without any iteration process. Introducing the power law of friction factor, various non-dimensional physical numbers are derived such as power-diameter number, power-discharge number, diameter-slope number and discharge-slope number. One of the physical numbers concerned with discharge or pipe diameter can be related to a combination of the other in an explicit way.

  • PDF

지열교환기의 배관자재에 따른 난방효율 분석 (Heating Efficiency of the Underground Heat Exchanger by Different Pipe Materials)

  • 오인환;이준학;정우철
    • 한국축산시설환경학회지
    • /
    • 제4권2호
    • /
    • pp.127-136
    • /
    • 1998
  • To use the earth heat for the livestock housing, an underground heat exchanger is developed and pipes are layed in the depth of 2.5m under the ground. The pipes have two different kinds of diameter (200mm, 100mm) and materials (PE, PVC). The results of heating effect in winter and spring are following. The temperature in different soil depth varies from 5$^{\circ}C$ by 1.5m depth, to 9$^{\circ}C$ by 3.5m. So it should be better to have the depth greater than 2.5m. The difference of air temperature between the inside and outside pipe was 9.9 Kelvin(K) with 200mm diameter and 13.4K with the 100mm diameter with the same material in winter. By the lower outside temperature from -7.2$^{\circ}C$, it could keep the air temperature above 6$^{\circ}C$ through the 100mm diameter pipe. The heating performance was 593 W with 200mm diameter, 118W with 100mm diameter (PE), and 115W with 100m diameter (PVC), respectively. As the outside temperature varies from -1.5$^{\circ}C$ to 18.6$^{\circ}C$ in early spring, the air temperature through the pipes show 4∼8$^{\circ}C$. While the difference between maximum and minimum outside temperature is 14K, the one through the pipes could be reduced by 2K. Pipes with small diameter can more reduce the difference than the pipe with larger diameter.

  • PDF

용접공정 및 용접형상 변화에 따른 소구경 분기배관 용접부의 피로특성 (Fatigue Properties of the Small Diameter Branch Welded Pipe Joint with variation of Welding Procedures and Welding Shapes.)

  • 백종현;김철만;김우식
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2003년도 추계학술발표대회 개요집
    • /
    • pp.191-193
    • /
    • 2003
  • S-N fatigue tests were conducted to investigate the fatigue strength of the small diameter socket and butt welded joints of carbon steels. Experimental parameters were pipe diameter, throat depth, shape of socket welds and welding procedure. Filler metals used in SMAW and GTAW procedure were E9016-G with diameter of 4.0 mm and ER70S-G with diameter of 2.4 m. API 5L Gr.B pipes were adopted as a small diameter branch pipes. All socket fittings were machined from ASTM A105 carbon steel. Fatigue strength in socket weld joints increased with increasing pipe diameter, area of weld metal and weld leg length of pipe side.

  • PDF

소구경 분기배관 용접부의 피로강도에 미치는 용접부 형상 및 용접공정의 영향 (Influence of Welding Shapes and Welding Procedures on Fatigue Strength of Small Diameter Branch Welded Pipe Joint)

  • 백종현;김철만;김우식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1092-1097
    • /
    • 2003
  • S-N fatigue tests were conducted to investigate the fatigue strength of small diameter socket and butt welded joints made of carbon steels. Experimental parameters were pipe diameter, throat depth, shape of socket welds and welding procedure. Filler metals used in SMAW and GTAW procedure were E9016-G with diameter of 4.0 mm and ER70S-G with diameter of 2.4 mm. API 5L Gr.B pipes were adopted as a small diameter branch pipes. All socket fittings were machined from ASTM A105 carbon steel. Tensile strength was not affected by the welding procedure. Fatigue strength in socket weld joints increased with increasing pipe diameter, area of weld metal and weld leg length of pipe side.

  • PDF

용접부의 형상과 공정변화에 따른 소구경 분기배관의 피로강도 특성평가 (S-N Fatigue Strength of Small Diameter Branch Welded Pipe with Variation of Welding Shapes and Welding Procedures)

  • 백종현;김우식
    • Journal of Welding and Joining
    • /
    • 제22권3호
    • /
    • pp.50-55
    • /
    • 2004
  • S-N fatigue tests were conducted to investigate the fatigue strength of small diameter socket and butt welded joints made of carbon steels. Experimental parameters were pipe diameter, throat depth, shape of socket welds and welding procedure. Filler metals used in SMAW and GTAW procedure were E9016-G with diameter of 4.0 m and ER70S-G with diameter of 2.4 m. API 5L Gr.B pipes were adopted as a small diameter branch pipes. All socket fittings were machined from ASTM A105 carbon steel. Tensile strength was not affected by the welding procedure. Fatigue strength in socket weld joints increased with increasing pipe diameter, area of weld metal and weld leg length of pipe side.

배수재의 직경과 형상변화가 수평진공배수에 미치는 영향 (Effects of Size and Shape of Drain on Horizontal Vacuum Drain)

  • 유남재;박병수;정길수;이병곤
    • 산업기술연구
    • /
    • 제21권A호
    • /
    • pp.293-301
    • /
    • 2001
  • This paper is experimental results of investigating the efficiency of horizontal vacuum drainage system. Effects of size and shape of drain on horizontal vacuum drainage were studied. Model tests in the laboratory with soft marine clay were carried out with drain pipe of having three different diameters and PBD (Plastic Board Drain) of strip shape so that consolidation settlement of soft clay due to applied vacuum pressure, amount of discharge, ground settlement and distributions of pore pressure and undrained shear strength were measured during testing. From results of model test, amount of discharge due to vacuum pressure was increased with the diameter of pipe drain whereas the drain efficiency of pipe in per unit area of drain surface was decreased with diameter of pipe. The rate of discharge per unit time was reduced very fast with diameter of pipe. Settlement of ground surface with time was increased with diameter of pipe as a result of increase of discharge to drain pipe.

  • PDF

상수급수관 인입관경 제안 및 수리해석 (Hydraulic Analysis and Sizing of Inlet-Pipe Diameter for the Water Distribution Network)

  • 신성교;김은주;최시환
    • 한국환경과학회지
    • /
    • 제31권1호
    • /
    • pp.33-42
    • /
    • 2022
  • The objective of this study is to determine the appropriate size of the inlet pipe diameter and thereby conduct hydraulic analysis for the Korean water distribution network. To this end, the data tables for equivalent pipe diameters and outflow rates presently employed in Korea were adopted. By incorporating the table of equivalent pipe diameters, it was found that the size of the inlet pipe diameter was overestimated, which can cause shortage of water pressure and malfunctioning or insufficiency of outflow rate in the corresponding adjacent region. However, by conducting hydraulic analysis based on the table of outflow rates, relatively reasonable flow rates were observed. Furthermore, by comparing the real demand-driven analysis (RDDA) approach and demand-driven analysis (DDA) approach toward managing the huge water demand, it was observed that DDA could not effectively respond to real hourly usage conditions, whereas RDDA (which reflects the hourly effects of inlet pipe diameter and storage tanks) demonstrated results similar to that of real water supply.

대구경 관로의 노후도 평가 연구(I) : 평가모형 개발 (Assessment of the Deterioration of Large-Diameter Pipe Networks (I) : Development of an Assessment Model)

  • 김응석;이승현;윤기용
    • 한국산학기술학회논문지
    • /
    • 제15권1호
    • /
    • pp.482-487
    • /
    • 2014
  • 본 연구(I)의 목적은 현재 K-water에서 실시하는 대구경 노후관로 개량사업시 매설관의 노후도를 판단할 수 있는 방법을 제시하였다. 대구경 관로의 노후도 평가모형을 개발하기 위해 국내의 대표적 평가기법 중 1995년 평가법, 2002년 평가법, 상태평가법 등 3개를 분석하였다. 대구경 관로의 노후도를 평가하기 위하여 기존의 3가지 평가방법별 인자의 우선순위를 바탕으로 공통 인자와 대구경 관로의 특성을 고려할 수 있는 인자를 함께 고려하여 10개 인자를 선정하였다. 또한 개발모형의 인자별 가중치는 국내의 대구경 관로의 실험 및 분석 값을 바탕으로 한 회귀식과 전문가 의견과 관리경험 등을 고려하여 산정하였다. 따라서 기존의 3가지 모형의 특성을 고려하여 개발된 평가모형은 대구경 관로의 노후도를 평가하기에 보다 신뢰성 있는 모형으로 판단된다.

해양온도차 발전을 위한 심층수 파이프 직경에 따른 에너지 손실량 검토 (Feasibility Study on Cold Water Pipe Diameter by Friction Loss and Energy Conversion on OTEC)

  • 정훈;허균영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.170-170
    • /
    • 2010
  • The energy conversion from the temperature difference between hot and cold source like ocean thermal energy conversion (OTEC), requires a long and large-diameter pipe (about 1000 to 10,000 meters long) to reach the deep water. The pipe diameter ranges from 2.8 meter for proposed early test systems, to 5 meter for large, commercial power generation systems. The pipe must be designed to resist collapsing pressures produced by water temperature and density differences, and the reduced pressure required to induce flow up the pipe. Other design considerations include the external-drag effect on the pipe due to ocean currents, and the wave-induced motions of the platform to which the pipe is attached. Various approaches to the pipe construction have been proposed, including aluminum, steel, concrete, and fiberglass. More recently, a flexible pipe construction involving the use of fiberglass reinforced plastic has been proposed. This report presents the results of a scaled fixed cold water pipe (CWP) model test program performed by EES(Engineering Equation Solver) to demonstrate the feasibility of this pipe approach.

  • PDF