• Title/Summary/Keyword: Pipe Resonance

Search Result 73, Processing Time 0.025 seconds

Reduction of Transient Vibration on $H_2$ Piping System for Generator Cooling in a Power Plant (화력발전소 발전기 냉각용 수소배관계 과도진동 개선)

  • Yang, Kyeong-Hyeon;Kim, Sung-Hwi;Cho, Chul-Whan;Bae, Chun-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.588-592
    • /
    • 2002
  • There was the transient vibration on $H_2$ piping system for cooling the generator in a power plant. We found it was resulted from resonance between the natural vibration of the piping system and exciting force from the turbine rotor by measurement and simulation test. We verified it would be changed the mode shape of the piping system by several simulation test for the structural modification of the piping system. Therefore we concluded that the change of natural vibration mode depends on deeply changing effective length of pipe and reducing supports.

  • PDF

Vibration and Noise Reduction of Pump And Pipe System (대형펌프와 조합된 배관계에서 발생하는 이상 진동 및 소음 저감에 관한 연구)

  • 배춘희;원종범;조철환;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.473-477
    • /
    • 2001
  • In this paper, Firstly, it is shown that the high vibration and noise source of piping and pump system is the acoustic resonance. Secondly, in order to decrease the high vibration and noise of piping and pump system, the acoustic mode of piping have been changed and its effectiveness is investigated as applied it at piping system practically.

  • PDF

Vibration and Noise Reduction of Pump And Pipe System (대형급수펌프 토출배관계에 발생하는 규칙적인 이상진동 및 소음 특성 규명)

  • 배춘희;조철환;양경현;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1065-1069
    • /
    • 2003
  • In this paper, Firstly, it is shown that the high vibration and noise source of piping and pump system is the acostic resonance. Secondly, in order to decrese the high vibration and noise of piping and pump system, the acostic mode of piping have been changed and its effectiveness is investigated as applied it at piping system practically.

  • PDF

An experimental investigation on the errect of air entrainment (공기유입이 화재강도에 미치는 영향에 대한 실험적인 연구)

  • Kim, Jin-Guk
    • Fire Protection Technology
    • /
    • s.21
    • /
    • pp.5-12
    • /
    • 1996
  • An experimental investigation has been made with the objcetive of studying the effects of air entrainment of fire strength. A rich jet flame is considered as an fire, and fire, and the air entrainment is controlled by introducing the tone excitation which is generated by means of a loudspeaker-driven cavity. The excitation frequency is chosen for the resonant frequency identified as a pipe resonance due to acoustic excitation. As the excitation intensity increases, the amplitude of oscillating velocity for inducing air entrainment is increased, the flame height decreased and the structure of diffusion flame gradually transformed to that of premixed flame.

  • PDF

Theoretical Analysis of Wave Energy Converter

  • Oh, Jin-Seok;Komatsu, Toshimitsu;Kim, Yun-Hyung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.169-174
    • /
    • 2008
  • Floating devices, such as a cavity resonance device take advantage of both the water motion and the wave induced motions of the floating body itself. The wave energy converter is known commercially as the WAGB(Wave Activated Generator Buoy) and is used in some commercially available buoys to power navigation aids such as lights and horns. This wave energy converter consists of a circular floatation body which contains a vertical center pipe that has free communication with the sea. A theoretical analysis of this power generated by a pneumatic type wave energy converter is performed and the results obtained from the analysis are used for a real wave energy converter for buoy. This paper presents the analysis results and the design method for the WEC(Wave Energy Converter), and the associate results are application to the commercially available WEC for buoy. Maximum performance of WEC occurs at resonance with driving waves. The analysis of WEC is performed with LabVIEW program, and the design method of WEC for buoy is suggested in this paper.

Phase Resonance in Centrifugal Fluid Machinery -A Comparison between Pump Mode and Turbine Mode Operations and a Discussion of Mechanisms of Flow Rate Fluctuation through a Stator-

  • Yonezawa, Koichi;Toyahara, Shingo;Motoki, Shingo;Tanaka, Hiroshi;Doerfler, Peter;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.7 no.2
    • /
    • pp.42-53
    • /
    • 2014
  • Phase resonance in Francis type hydraulic turbine is studied. The phase resonance is a phenomenon that the pressure fluctuation in the penstock of hydraulic turbine installation can become very large when the pressure waves from each guide vane caused by the interaction with the runner vane reach the penstock with the same phase. Experimental and numerical studies have been carried out using a centrifugal fan. In the present study, comparisons between the pump mode and the turbine mode operations are made. The experimental and numerical results show that the rotational direction of the rotor does not affect characteristics of the pressure fluctuation but the propagation direction of the rotorstator interaction mode plays an important role. Flow rate fluctuations through the stator are examined numerically. It has been found that the blade passing flow rate fluctuation component can be evaluated by the difference of the fluctuating pressure at the inlet and the outlet of the stator. The amplitude of the blade passage component of the pressure fluctuation is greater at the stator inlet than the one at the stator outlet. The rotor-stator interaction mode component is almost identical at the inlet and the outlet of the stator. It was demonstrated that the pressure fluctuation in the volute and connecting pipe normalized by the flow rate fluctuation becomes the same for pump and turbine mode operations, and depends on the rotational direction on the interaction mode.

A Study on Design Criteria of Piping System in Petrochemical Plant (석유화학 플랜트의 배관계 설계기준에 대한 연구)

  • Min, Sun-Kuo;Choi, Myung-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.6
    • /
    • pp.192-199
    • /
    • 2002
  • Largely, there are three kinds of the design criteria of piping system in petrochemical plant. The first is on the pipe thickness in accordance with the design pressure of piping system. The second is on the static state evaluation by thermal growth and the other is on the dynamic evaluation by piping vibration. According to the ASME B31.3 code, the internal pressure design thickness fur straight pipe shall be calculated as a code formula. And the static design by thermal displacement is defined 7000 cycles of fatigue life in operating the piping system with a design condition. However, the dynamic design evaluation in comparative with small displacements of high frequencies to the static condition has not established clearly the method, yet. So, this study purposes to present the trial of a proposal of dynamic design criterion on the basis of static design method.

Study on the effect of corrosion defects on VIV behavior of marine pipe using a new defective pipe element

  • Zhang, He;Xu, Chengkan;Shen, Xinyi;Jiang, Jianqun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.552-568
    • /
    • 2020
  • After long-term service in deep ocean, pipelines are usually suffered from corrosions, which may greatly influence the Vortex-Induced Vibration (VIV) behavior of pipes. Thus, we investigate the VIV of defective pipelines. The geometric nonlinearity due to large deformation of pipes and nonlinearity in vortex-induced force are simulated. This nonlinear vibration system is simulated with finite element method and solved by direct integration method with incremental algorithm. Two kinds of defects, corrosion pits and volumetric flaws, and their effects of depth and range on VIV responses are investigated. A new finite element is developed to simulate corrosion pits. Defects are found to aggravate VIV displacement response only if environmental flow rate is less than resonance flow rate. As the defect depth grows, the stress responses increase, however, the increase of the defect range reduces the stress response at corroded part. The volumetric flaws affect VIV response stronger than the corrosion pits.

Analysis of Seismic Response of the Buried Pipeline with Pipe End Conditions (단부 경계조건을 고려한 매설관의 동적응답 해석)

  • Jeong Jin-Ho;Lee Byong-Gil;Jung Du-Hwoe;Park Byung-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.33-43
    • /
    • 2005
  • This work reports results of our study on the dynamic responses of the buried pipelines both along the axial and the transverse directions under various boundary end conditions. In order to investigate the effect of the boundary end conditions for the dynamic responses of the buried pipeline, we have devised a computer program to find the solutions of the formulae on the dynamic responses (displacements, axial strains, and bending strains) under the various boundary end conditions considered in this study, The dynamic behavior of the buried pipelines for the forced vibration is found to exhibit two different forms, a transient response and a steady state response, depending on the time before and after the transfer of a seismic wave on the end of the buried pipeline. We have observed a resonance when the mode wavelength matches the wavelength of the seismic wave, where the mode number(k) of resonance f3r the axial direction. On the other hand, we have not been able to observe a resonance in the analysis of the transverse direction, because the dynamic responses are found to vanish after the seventh mode. From the results of the dynamic responses at many points of the pipeline, we have found that the responses appeared to be dependent critically on the boundary end conditions. Such effects are found to be most prominent especially for the maximum values of the displacement, the strain and its position.

Acoustic Investigation on BFP Piping System in a Power Plant (발전소 급수용 펌프 배관계의 음향학적 현상 고찰)

  • Yang, K.H.;Cho, C.H.;Bae, C.H.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.11
    • /
    • pp.1029-1035
    • /
    • 2011
  • Pressure pulsation of exciting sources that generally occurs on the piping system connected to the discharge of BFP(boiler feed water pump) in power plants causes wave reflection, wave interference, resonance, standing wave and so on. But if the operating speed of the pump is changed, the state of the noise and vibration can be done because characteristics of the exciting source are changed. This paper is to investigate the cause of the noise and vibration occurring on the piping system when the operating speed of BFP is down in accordance with lowering of the power generation. It is approached to two points of view ; Firstly, it is examined whether the pulsation source impacts on the shell mode vibration that vibrates radially across the cross-section of the pipe. But it doesn't affect the shell mode as much as the resonance occurs. Secondly, to find the relation between the pulsation source and the acoustic mode of the piping system, analysis for the piping system by indirect BEM(boundary element method) is carried out. Therefore it is investigated that the mechanism of the noise and vibration relates with acoustic mode of the piping system.