• Title/Summary/Keyword: Pin on disk

Search Result 247, Processing Time 0.027 seconds

The effect of solid lubricant on the frictional characteristics of Cu base sintered friction material. (소결 마찰재의 마찰특성에 미치는 고체 윤활제의 영향)

  • 정진현;이범주;조정환;정동윤;권석진
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1996.04b
    • /
    • pp.45-54
    • /
    • 1996
  • The effect of graphite on the frictional characteristics of Cu-based sintered friction materials was studied by pin-on-disk type wear test. A study has been carried out concerning the optimum concentration of graphite in sintered friction material to obtain the minimum wear rate and low friction coefficient . Friction coefficient and wear rate were increased as increasing the content of graphite in the matrix. In the study the optimum concentration of graphite was 19vol % to get the minimum wear rate and optimal frick'ion coefficient.

  • PDF

Wear Characteristics of $Cr_{2}O_{3}\;and\;ZrO_{2}$Coating Materials by Plasma Spray ($Cr_2O_3$$ZrO_{2}$ 플라즈마 용사한 코팅재의 마모 특성)

  • Kim, Sung-Ig;Kim, Hee-Gon;Lee, Bong-Gil;Kim, Gui-Shik
    • Tribology and Lubricants
    • /
    • v.22 no.6
    • /
    • pp.335-341
    • /
    • 2006
  • This paper reports the wear characteristics of two types of coating materials, which are $Cr_2O_3$ and $ZrO_2$, by coated plasma thermal spray method. The wear test was carried out under air, grease, and bearing fluid conditions. The wear testing machine of a pin-on disk type were used to measure friction forces, friction coefficients and the weight losses of the coating specimens on the various sliding velocity and loading condition. The wear surface of specimens were observed by scanning electron microscope (SEM) photographs.

Tribological Performance of Supper-A Dental Material (치과용 재료 Supper-A의 트라이볼로지적 고찰)

  • Choi, Won-Sik;Kim, Won-Ku;Kwon, Soon-Hong;Chung, Sung-Won;Kwon, Soon-Gu;Park, Jong-Min
    • Tribology and Lubricants
    • /
    • v.23 no.6
    • /
    • pp.318-322
    • /
    • 2007
  • The wear characteristics in supre-A dental material have been investigated. The wear tests were performed by using pin-on-disk wear tester at room temperature. Vickers hardness and fracture toughness measurement of dental materials were preformed. Microscopic observations on worn surfaces of specimens were conducted by SEM. The friction coefficient of supper-A material was investigated according to weight and slinging velocity. The hardness of supper-A material was a half of the enamel of natural teeth.

Experimental Study on Hardness and Wear Characteristics of Welded Rails (레일 용접부의 경도와 마멸특성에 관한 실험적 연구)

  • Kim, Chung-Kyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.2 s.173
    • /
    • pp.431-437
    • /
    • 2000
  • In this paper, thermite and gas pressure weldings have been used to join rails in-track and analyzed as functions of hardness and wear characteristics. The wear rate of thermite welded rail is low compared with that of gas pressure welded rail, which is tested in a pin-on-disk wear tester. The hardness of thermite welded materials is relatively high and narrowly distributed between three zones; welded part, thermally affected zone, and base matrix. Wear of a welded rail may be a major factor in railroad maintenance costs and failures at the rail-rail huh joint.

Effects of Counterpart Materials on Dry Sliding Wear and Friction Behavior of Co-Fe, Co-Ni Bond Materials for Diamond Tools (다이아몬드 공구용 Co-Fe, Co-Ni 본드 소재의 마멸상대재에 따른 건식 미끄럼 마찰 및 마멸거동)

  • 권용진;김용석
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.28-28
    • /
    • 2003
  • 고온가압소결(Hot Pressing) 된 다이아몬드 공구용 Co-Fe, Co-Ni계 금속본드의 상온 건식 미끄럼 마멸시험을 행하고, 조성에 따른 각 본드의 마멸 특성을 비교하고 마멸 기구를 규명하였다. 미끄럼 마멸시험은 pin-on-disk 형태의 마멸시험기를 사용하여 각 조성의 성분, 적용하중 그리고 마멸상대재를 변수로 상온, 대기 중에서 실시되었다. 마멸속도는 마멸시험 전후의 시편의 무게 감량을 이론밀도와 거리로 나누어 계산되었다. 마멸기구의 규명을 위하여 시험된 시편의 마멸면과 마멸단면을 SEM과 EDS를 이용하여 분석하였다. 시험 결과 Co-Fe system의 경우 그 마멸속도는 마멸상대재의 영향보다는 Fe 첨가에 따른 시편의 미세조직과 기계적 성질의 차이에 따라 크게 변화하였다. 그러나 Co-Ni system의 마멸속도는 마멸 상대재에 따라 크게 변화하는 것이 관찰되었다. $Al_2$O$_3$를 상대재로 마멸된 경우에는 마멸속도가 시편/상대재 접촉면에서 형성되는 산화층의 영향을 크게 받았고, glass bead(83% SiO$_2$)를 상대재로 한 경우에는 시편의 경도와 마멸속도는 서로 반비례하였다.

  • PDF

Relationship between Oxidation and Wear of Ultra-High Molecular Weight Polyethylene for Total Joint Arthroplasty

  • Lee, Kwon-Yong
    • KSTLE International Journal
    • /
    • v.2 no.1
    • /
    • pp.55-58
    • /
    • 2001
  • The most widely-used orthopaedic grade polymer bearing liner material, ultrahigh molecular weight polyethylene (UHMWPE), for the total joint arthroplasty degrades after gamma-irradiation sterilization through the progressive oxidation in a shelf and in vivo. Oxidative degradation makes UHMWPE brittle and leads to decrease in mechanical properties. In this study the relationship between post-gamma-irradiation aging time and wear of UHMWPE was investigated. Six retrieved polyethylene hip liners implanted for 3-16 years and then stored in air for 1.5-6.5 years until tests were used. Two types of pin-on-disk wear testing were conducted by the uni-directional repeat pass rotating and by the linear reciprocating stainless steel disks against stationary polyethylene pins under 4Mpa at 1Hz with bovine serum lubrication in ambient environment. Wear of retrieved polyethylene hip liners does not have direct correlation with in vivo or total aging time. Linear reciprocal sliding motion generated more remarkable wear than uni-directional repeat pass sliding motion. It indicates that kinematic motion affects very crucially on the wear of aged UHMWPE having brittle white band region.

  • PDF

Characteristics of Plasma Nitriding and Nitrocarburizing of Steam Treated Sintered Steels (스팀처리된 소결강의 플리즈마 질화 및 연질화 특성)

  • 박주승
    • Journal of Powder Materials
    • /
    • v.4 no.4
    • /
    • pp.268-274
    • /
    • 1997
  • Characteristics of plasma nitriding and nitrocarburizing for steam treated sintered steels were studied. Fe-0.8%C powder containing Ni, Cu were sintered at 112$0^{\circ}C$ and steamed at 52$0^{\circ}C$. Temperature of plasma nitriding and nitrocarburizing was varied from 50$0^{\circ}C$ to $600^{\circ}C$. Gas mixture of nitriding was set at $N_2$ : $H_2$ =80:20 (vol.%), but $CH_4gas$ was added 1~2 vol.% for nitrocarburizing. Steam treatment for sintered steels brought not only the formation of oxide layer but also decarburizing near the surface. Decrease in hardness near the surface resulted from the formation of ferrite due to decarburizing. Thus, the low hardness was recovered not with plasma nitriding but with plasma nitrocarburixing. Wear resistance properties of steamed specimens and ni-trocarburized specimens were better than those of nitrided specimens according to the pin-on-disk wear test. On the other hand, the fatigue life of steamed specimen was shorter than that of nitrocaiburized specimen.

  • PDF

심전계(ECG)의 제작설계

  • 서병설
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.2
    • /
    • pp.247-250
    • /
    • 1988
  • Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology.

  • PDF

Analysis of Wear Debris on the Lubricated Machine Surface by the Neural Network (Neural Network에 의한 기계윤활면의 마멸분 해석)

  • 박흥식
    • Tribology and Lubricants
    • /
    • v.11 no.3
    • /
    • pp.24-30
    • /
    • 1995
  • This paper was undertaken to recognize the pattern of the wear debris by neural network as a link for the development of diagnosis system for movable condition of the lubricated machine surface. The wear test was carried out under different experimental conditions using the wear test device was made in laboratory and wear testing specimen of the pin-on-disk type were rubbed in paraffine series base oil, by varying applied load, sliding distance and mating material. The neural network has been used to pattern recognition of four parameter (diameter, elongation, complex and contrast) of the wear debris and learned the friction condition of five values (material 3, applied load 1, sliding distance 1). The three kinds of the wear debris had a different pattern characteristic and recognized the friction condition and materials very well by the neural network. The characteristic parameter of the large wear debris over a few micron size enlarged recognition ability.

An Investigation of Sliding Wear and Microstructural Evolution of Ultra-Fine Grained Pure Al Fabricated by ARB Process (누적압연접합(Accumulative Roll-Bonding, ARB)에 의한 Al의 결정립 미세화와 마모 특성 연구)

  • Park K.S.;Lee T.O.;Kim Y.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2000.10a
    • /
    • pp.21-24
    • /
    • 2000
  • Ultra-fine grains were produced in pure Al using an Accumulative Rolling-Bonding (ARB) process. After several cycles of the ARB process, pure Al sheets were filled with the ultra-fine grains whose diameters were several hundred nano-meters. With ARB cycles, the nature of grain boundaries of the ultra-fine grains changed from diffusive sub-boundaries to well-defined high angle boundaries. After 7 cycles, ultra-fine polycrystals with large misorientations between neighboring grains were obtained. Sliding wear tests using a pin-on-disk type wear tester were co ducted on the ultra-fine grained pure Al. Wear rates of pure Al increased with the increase of ARB cycle numbers in spite of the increase in hardness. Worn surfaces and cross-sections were examined with optical microscopy (OM) and scanning electron microscopy (SEM) In investigate the wear mechanism of the ultra-fine grained pure Al.

  • PDF