• 제목/요약/키워드: Pin implant

검색결과 25건 처리시간 0.025초

단층촬영상에서 계획된 임플랜트 매식 각도 및 위치에 대한 스텐트 핀의 상대적 각도 및 위치에 대한 평가 (The angulation and the position change of the planned implant after tomographic imaging)

  • 강병철
    • Imaging Science in Dentistry
    • /
    • 제37권3호
    • /
    • pp.127-131
    • /
    • 2007
  • Purpose: To measure the differences of the splint pin angulation and the position of the planned implant site after conventional tomographic analysis. Materials and Methods: The angulation and the location of the metal splint pin retained in acrylic stent were compared with the corrected angulation and the location of the implant fixture on the 331 tomographic images. Results: The stent pins were located buccal in 40%, lingual in 10% to the corrected implant site after analysis of the conventional tomographic image. The angle and the location of the maxillary splint pin were mainly directed buccal on incisor and canine regions. The angle and the location of the splint pins in premolar and molar regions needed less corrections in both maxilla and mandible. Conclusions: This study demonstrated that the use of tomographs was essential for successful dental implant planning.

  • PDF

R.P.I.(ring pin implant)를 응용한 치아의 재식과 이식 (Transplantation and Replantation Using R.P.I.(ring pin implant))

  • 김재철
    • 대한심미치과학회지
    • /
    • 제8권1호
    • /
    • pp.36-44
    • /
    • 1999
  • No one really doubts that the hottest area of dentistry in 21st century would most likely be 'implant'. With the support of a vast amount of research, implant has been successfully and rapidly absorbed into the field of general dentistry including private practitioners. For teeth with hopeless(or refractory) periodontitis or periapical pathosis, with no hesitation most dentists would think extraction as the sole treatment option followed by prosthodontic replacement possibly including implant. Not many dentists would take Trasplantation/Replantation as another treatment option for a particular condition. Dentistry is often more focused on 'Restoration' than 'Preservation' of natural dentition. 'Biologic Implant' is obviously much closer to the concept of 'Preservation'. Many different types of biologic implant system have been introduced to clinical dentistry so far. Many of those have failed to earn reasonable acknowledgement despite of the clinical success they brought. For some reason biologic implant has rather been alienated for long time. RPI(Ring Pin Implant) is designed to improve the prognosis and success rate of transplanted/replanted teeth. RPI is a Ti-based custom made implant system. It is fabricated either by electric casting or milling process. The major feature RPI gas is the 'ring & hole' structure. The hole should be no less than 1mm diameter to allow bone bridge formation thru it. The ring structure and bone bridge formation creates anti-torque activity, which largely increases the 'initial stability' of the transplanted/replanted teeth. It is also reported that RPI is beneficial in the aspect of resisting root resorption following replantation/transplantation procedure.

  • PDF

질소이온주입에 따른 생체안전성 티타늄 임플란트의 마모특성 (Wear Properties of Biocompatible Ti Implant due to Nitrogen Ion Implantation)

  • 최종운;손선희;변응선;정용수
    • 한국안전학회지
    • /
    • 제14권4호
    • /
    • pp.126-134
    • /
    • 1999
  • In this study, plasma source ion implantation was used to improve the wear properties of biocompatible titanium implant. In order to observe the effect of ion energy and dose on wear property of titanium implant, pin-on-disk type wear tests in Hank's solution were carried out. The friction coefficient of ion implanted specimens were increased from 0.47 to 0.65 under high energy and ion dose conditions. As increasing ion energy and ion dose, the amount of wear was reduced.

  • PDF

한 환자에서 실패한 임플란트 부착장치들의 원인과 이중관 임플란트 피개 의치의 적용 (Causes of failed implant attachments and application of double crown implant overdenture in one patient)

  • 권재욱;조진현
    • 대한치과보철학회지
    • /
    • 제56권4호
    • /
    • pp.368-374
    • /
    • 2018
  • 본 증례의 환자는 약 10여년 전 2개의 임플란트를 이용하여 Gold Hader bar 하악 임플란트 피개 의치로 수복하였고, 3년 6개월의 사용으로 인한 bar의 심한 마모로 유지력을 상실하였다. 이를 Locator 부착장치를 이용하여 하악 피개 의치를 수리하였으나, Locator 사용 6년 6개월 후 male 부위가 완전히 닳은 상태로 내원하게 되었다. 다음으로는 하이브리드 이중관(Hybrid telescopic double crown with friction pin)을 사용하여 임플란트 피개 의치를 새로 제작하였고, 이를 2년동안 관찰한 결과 우수한 예후를 보여주고 있다. 여기에서 한 환자에서 2가지(Gold Hader bar, Locator)방법으로 수복한 임플란트 피개 의치에서 각 부착장치의 실패원인에 대해서 알아보고, 이중관 피개 의치의 장단점과 성공을 위한 조건에 대해서 보고하고자 한다.

Implant overload 감소를 위한 교합면 형성 방법 (A method of contouring occlusal surface for reduction of implant overload)

  • 이병우;박찬진;조리라;이양진
    • 구강회복응용과학지
    • /
    • 제19권2호
    • /
    • pp.105-108
    • /
    • 2003
  • After stage-two surgery, the highest incidence of failure has been attributed to implant overload. However, the biomechanical factors cited inthe literature that contribute to implant overload, such as bone type, cuspal inclination, horizontal offset, maxillary compared to mandibular arch, the inclusion of natural teeth within the prosthesis, and occlusal harmony are superimposed on physiologic variations. Following two cases, including reduction of cuspal inclination and usage of modified incisal pin, showed a method of contouring occlusal surface for reduction of unpreditable implant overload.

REMOVAL TORQUE OF BICORTICALLY STABILIZED RBM(RESORBABLE BLAST MEDIA) PIN IMPLANTS IN RABBIT TIBIA

  • Kim, Kwon-Sik;Suh, Kyu-Won;Lee, Richard Sung-Bok;Ryu, Jae-Jun
    • 대한치과보철학회지
    • /
    • 제44권6호
    • /
    • pp.722-733
    • /
    • 2006
  • Statement of problem. The use of small diameter implants having less than 3 mm in diameter were restricted because of lack of bonding strength to bone. Purpose. The purpose of this study was to observe how much resorbable blast media pin implants increase the binding force to the bone compared to machined transitional pin implants by measuring removal torque, and whether they can be used as final implants for replacement of small diameter teeth. Material and method. Fifteen rabbits were used in this study. Two kinds of implants (resorbable blast media pin implants and machined transitional pin implants) were inserted in each tibia bicortically. After healing time of 2, 4 and 8 weeks, the removal torque values were recorded and the rabbits were sacrificed for histological analysis. Linear finite element method analyses were conducted to compare bicortical fixation with monocortical fixation. Result and conclusion. Within the limitation of this in vivo study, the following conclusions were drawn: 1) The removal torque value of RBM pin implants showed statistically significant increase compared to machined pin implants at 2, 4, and 8 weeks respectively (p<0.05). 2) The removal torque value of RBM pin implants at 2, 4, and 8 weeks was increased statistically significantly with time (p<0.05). 3) Bicortical fixation showed better stress distribution compared with monocortical fixation in a linear finite element method analysis. 4) RBM pin implants are not recommended as transitional implants because they showed a lot of bone fracture in histologic specimens.

성견에서 차단막/골이식재 복합체를 이용한 임플란트 주위 골유도재생 효과: 임상적, 방사선학적, 조직학적 평가 (Local ridge augmentation using a composite of bone substitute and collagen membrane at peri-implant dehiscence defects: a clinical, radiographic and histological analyses.)

  • 송영우;윤소라;차재국;이중석;최성호;정의원
    • 대한치과의사협회지
    • /
    • 제55권10호
    • /
    • pp.676-687
    • /
    • 2017
  • Objectives : The aim of this study was to evaluate the effects of a composite of bone substitute and collagen barrier membrane (bone patch) for local ridge augmentation at peri-implant dehiscence defects on the clinical efficacy and positional stability in dogs. Materials and methods : Implant placement and ridge augmentation procedure were performed at surgically created peri-implant dehiscence defects in canine mandible (n=6). Four treatment modalities were randomly applied: i) bone patch group, ii) Guided bone regeneration (GBR) without pin fixation group (bone graft and collagen membrane), iii) GBR with pin fixation group, and iv) negative control group. After 12 weeks, clinical, micro-CT and histological analyses were performed. Results : Histologic analysis showed that bone patch group had similar results to GBR group and GBR with fixation group in terms of new bone formation. Micro-CT analysis revealed similar results to histologic analysis in terms of total volume maintenance. Operating time was shorter in bone patch group compared to GBR group and GBR with fixation groups. Conclusions : GBR using bone patch could simplify the ridge augmentation procedure with reduced operating time and equivalent biological performance compared to the conventional procedure.

  • PDF

Mixed reality visualization in shoulder arthroplasty: is it better than traditional preoperative planning software?

  • Sejla Abdic;Nicholas J. Van Osch;Daniel G. Langohr;James A. Johnson;George S. Athwal
    • Clinics in Shoulder and Elbow
    • /
    • 제26권2호
    • /
    • pp.117-125
    • /
    • 2023
  • Background: Preoperative traditional software planning (TSP) is a method used to assist surgeons with implant selection and glenoid guide-pin insertion in shoulder arthroplasty. Mixed reality (MR) is a new technology that uses digital holograms of the preoperative plan and guide-pin trajectory projected into the operative field. The purpose of this study was to compare TSP to MR in a simulated surgical environment involving insertion of guide-pins into models of severely deformed glenoids. Methods: Eight surgeons inserted guide-pins into eight randomized three-dimensional-printed severely eroded glenoid models in a simulated surgical environment using either TSP or MR. In total, 128 glenoid models were used and statistically compared. The outcomes compared between techniques included procedural time, difference in guide-pin start point, difference in version and inclination, and surgeon confidence via a confidence rating scale. Results: When comparing traditional preoperative software planning to MR visualization as techniques to assist surgeons in glenoid guide pin insertion, there were no statistically significant differences in terms of mean procedure time (P=0.634), glenoid start-point (TSP=2.2±0.2 mm, MR=2.1±0.1 mm; P=0.760), guide-pin orientation (P=0.586), or confidence rating score (P=0.850). Conclusions: The results demonstrate that there were no significant differences between traditional preoperative software planning and MR visualization for guide-pin placement into models of eroded glenoids. A perceived benefit of MR is the real-time intraoperative visibility of the surgical plan and the patient's anatomy; however, this did not translate into decreased procedural time or improved guide-pin position.

무선 Biotelemetry용 인체 이식형 안테나 (A Scalp-Implantable Antenna for Wireless Biotelemetry)

  • 유형석
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.112-115
    • /
    • 2016
  • This paper demonstrates a scalp-implantable miniaturized antenna at the medical implant communication service (MICS) (402-405MHz) band. The antenna size is only $27.63mm^3$($8.5mm{\times}6.5mm{\times}0.5mm$), which is the smallest antenna for the MICS band. Miniaturization is achieved by using a symmetrical serpentine shaped radiating patch and placing open-end slots in the ground plane. In addition, co-axial feeding is used for excitation with a shorting pin connected between the radiator and ground. The antenna was simulated in a homogeneous skin model and in the human scalp. An experimental prototype of the proposed antenna was fabricated and measured in a skin-mimicking gel. Good agreement was obtained between the measurement and simulation results, showing a broad bandwidth of 49 MHz (from 395 to 444 MHz) for |S11| less than -10 dB and a maximum gain of -42.87 dBi. This gain is higher than the previous MICS antenna with respect to antenna size.

장기간 사용한 이중관 의치의 실패원인 및 자연치와 임플란트를 이용한 이중관 의치 수복증례 (Causes of failures of long-term used double crown denture and new rehabilitation with dental implant and tooth combined denture using remaining teeth and implants)

  • 서정교;조진현
    • 대한치과보철학회지
    • /
    • 제56권4호
    • /
    • pp.384-390
    • /
    • 2018
  • 치주적으로 지지가 불리한 소수의 잔존치가 남은 환자에게 있어 하이브리드 텔레스코픽형 이중관의치는 장기적으로 안정적인 예후를 보이는 치료가 된다. 편측 악궁에 소수 잔존치가 남고 반대측 악궁에 다수의 자연치가 존재 하는 경우 임플란트를 식립하여 자연치와 혼재된 형태의 이중관 의치를 제작 할 시 의치의 지지 및 안정요소의 향상과 더불어 저작력의 균형을 맞추어 줄 수 있게 된다. 본 증례는 55세 여자 환자로 만성 치주염으로 인해 치주 지지가 감소한 소수 잔존치 상태에서 자연치만으로 하이브리드 텔레스코픽형 이중관 의치 치료를 통해 9.5년간 의치를 사용하였다. 9.5년 후 지대치 파절로 내원 하여 임플란트의 식립을 통해 자연치와 임플란트가 혼재된 하이브리드 텔레스코픽형 이중관 의치로 재수 복 하였으며, 이를 통해 재 치료에서도 장기적 예후의 안정성을 기대 할 수 있다.