• 제목/요약/키워드: Pin Screw

검색결과 37건 처리시간 0.026초

재사용 파이프서포트(V2)의 품질관리 향상에 관한 연구 (A Study on Quality Management Improvement of Used Pipe Support(V2))

  • 박종근;최명기
    • 한국안전학회지
    • /
    • 제34권3호
    • /
    • pp.36-41
    • /
    • 2019
  • As the prefabricated shoring system structure, which is a temporary structure, is often collapsed due to various reasons during concrete pouring, and directly affects not only the safety of the workers but also the quality of the final building, it is necessary to ensure the safety. It is considered that the pipe supports which are widely used as the prefabricated shoring materials in the construction site do not satisfy the performance criteria in many cases. Therefore, this study investigated the detailed conditions for satisfying the performance criteria and suggested the factors for improving the quality control level in order to prevent collapse accidents due to pipe supports reused at the construction site, As the results of test in order to understand the effect of the pipe supports (V2), which are being reused in the field, on the performance by factor, the performance was evaluated to be high in case of the small female screw clearance and the supporting pin with 12mm in diameter or larger.

송아지에서 발생한 긴뼈골절의 내고정 치료 6례 (Internal Fixation of Long Bone Fractures in 6 Calves)

  • 박진욱;조기래;김중현;최석화;김근형
    • 한국임상수의학회지
    • /
    • 제24권4호
    • /
    • pp.658-662
    • /
    • 2007
  • The simple and easy treatment with cast or splint has been applied to stabilize long bone fractures in farm animals. Applying cast or splint is relatively easier than surgical fixation and may temporarily stabilize fracture site. However, the internal fixation provides strong stabilization and early recovery of limb function. In this report, we describe six cases of limb fractures in calves repaired by internal fixation. Fracture sites are various and affected ages are between 1 day and several months old. In some cases, patients were treated with cast or splint before admitting to Veterinary Medical Center. In these patients, regardless of initial treatment fractures were not immobilized. Consequently we decided to treat these patients with open reduction and internal fixation. The fracture repair with implants(bone plate, screw, cerclage wire, and intramedullary pin) were effective and satisfactory in calves which had been failed by application of cast. Although the cost of orthopedic treatment in farm animal is one of the most important considerations from the practical point of view, internal fixation has many benefits in newborn and young calves. And simplicity of postoperative management is also practically significant benefit expected from infernal fixation In conclusion, we suggest that internal fixation will produce better result than external coaptation in calve.

하악 과두 골절의 개방 정복 시 근위 골편의 수복법 (A Technique for Assist in Positioning the Proximal Segment during Open Reduction of a Fractured Mandibular Condyle)

  • 김명국
    • Archives of Plastic Surgery
    • /
    • 제33권6호
    • /
    • pp.792-796
    • /
    • 2006
  • Purpose: After exposure of fracture site, the proximal segment must be reduced to their preinjury position for open reduction of fractured mandibular condyle. We examined the use of inter-maxillary fixation screws or titanium screws tied with stainless steel wire to assist in positioning of proximal segment. Since it enables to make a relatively small preauricular incision by not disturbing the operative field like Moule pin, we can reduce the danger of injury to the facial nerve. Methods: A preauricular approach was used for exposure, reduction, and rigid fixation in 4 cases of mandibular condylar fractures. Inter-maxillary fixation screws or titanium screws tied with stainless steel wire were used to assist in aligning proximal segment. The joints were submitted to functional exercises and postoperative radiologic and clinical follow-ups were performed. Results: No facial nerve lesions were found in all 4 cases. Radiologic follow-up showed correct reduction and fixation in all 4 cases. Clinical follow-up showed an initial limitation, but normal morbility of the condyle was achieved within 4 months after the operation, with a maximum mouth opening of $34.1{\pm}5.2mm$ after 12 months. There found no occlusal disturbances, no trismus, no lateral deviations of the mandible. Conclusion: By using Inter-maxillary fixation screws tied with stainless steel wire, it was shown that reducing the proximal segment to their preinjury position is easy to perform and it enables us to make a minimal dissection below preauricular skin incision to avoid facial nerve injury.

단측성 외고정 기구를 이용한 개의 대퇴골 신연에 있어서 골수강내 K-강선 삽입의 효과 (Effects of Intramedullary K-wire Insertion on Femoral Lengthening in Canine with Monolateral External Fixator)

  • 황재민;김영기;진희택;석성훈;이희천;고필옥;장홍희;이효종;연성찬
    • 한국임상수의학회지
    • /
    • 제23권3호
    • /
    • pp.291-299
    • /
    • 2006
  • During long bone lengthening, there are many disadvantages including axial deviation, malalignment and re-fracture which are commonly encountered inspite of its proven abilities. To study the effects of intramedullary K-wire application on the lengthening of long bone, ten skeletally mature mongrel dogs were separated into two groups(Group I, II). Right femurs of group I(5 dogs) were fixed with only monolateral external fixator after subperiosteal osteotomy. Right femurs of group II(5 dogs) were fixed with mono lateral external fixator and intramedullary K-wire after subperiosteal osteotomy. Lengthening was started at 7 days after the surgery with the rate of 0.5 mm per day for 5 weeks and the dogs were sacrificed after 15 weeks postoperatively to examine histologic differences and evaluate bone mineral density. Radiographic examination at an interval of two weeks was done to evaluate the type of callus formed and to analyze complications including instability of external skeletal fixation and axial deviation. Bone mineral density at the lengthened area and contralateral nonlengthened area were measured using quantitative computerized tomography. Histological examination of regenerated bone was performed using Masson's trichrome stain method. The radiographs demonstrated poor callus formation, higher incidence of axial deviation and screw loosening in the group I compared to the group II. The bone mineral density at the lengthened area in the group II was higher than that of the group I(P<0.05). Histological examination showed that the new bone trabeculae in the group II were greater than that of the group I. In conclusion, the combination of monolateral external fixator and intramedullary K-wire can prevent pin loosening, axial deviation and reduce healing period in dogs.

동측 원위 비골 지주를 이용한 경-거-종골 관절 유합술 (Tibiotalocalcaneal Arthrodesis Using Ipsilateral Distal Fibula Buttress)

  • 조세현;이정수;정순택;박형빈;황선철;정재헌;차민석
    • 대한족부족관절학회지
    • /
    • 제10권2호
    • /
    • pp.213-217
    • /
    • 2006
  • Purpose: To evaluate the clinical and radiological results of tibio-talo-calcaneal arthrodesis using ipsilateral distal fibula buttress which had advantages of extended operative field and release of contracted soft tissue. Materials and Methods: We retrospectively reviewed 4 postraumatic compartment syndrome, 2 residual poliomyelitis, 1 posttraumatic osteoarthritis with subtalar joint infection and 1 posttarumatic sciatic nerve palsy patients who underwent a tibio-talo-calcaneal arthrodesis from April, 1996 to March, 2002. Each of the cases was notable for a severe rigid equinovarus, persistent pus drainage of calcaneal area and paralytic foot. The mean duration of follow up was 18 months (range, $13{\sim}42$ months). The pain, function and alignment were evaluated by the modified ankle hindfoot scale of the American Orthopaedic Foot and Ankle Society (AOFAS) and patients satisfaction clinically. The radiological union were evaluated by plain AP and lateral radiographs. Results: The AOFAS score improved from 58 points (range, $47{\sim}78$) preoperatively to 82 (range, $60{\sim}89$) postoperatively. Patents satisfaction checked at 12 months after operation had favorable results (excellent and good 80%). Union rate was 100% radiographically and the mean duration of union was 12.5 weeks (range $8{\sim}22$ weeks). There was 2 cases of superficial pin tract infection and one protrusion of screw. Conclusion: Tibio-talo-calcaneal arthrodesis using ipsilateral distal fibula buttress was good modality of arthrodesis which provides wide operative field and release of contracted soft tissue in some cases of contracted foot.

  • PDF

슬괵건을 이용한 관절경적 전방십자인대 재건술 (Clinical Results of Arthroscopic Anterior Cruciate Ligament Reconstruction using Hamstring Tendon)

  • 송은규;서형연;이근배;윤택림;심상돈
    • 대한관절경학회지
    • /
    • 제3권1호
    • /
    • pp.17-23
    • /
    • 1999
  • 목적 : 전방십자인대 손상환자에서 슬괵건을 이용한 관절경적 전방십자인대 재건술을 시행하고 그 임상적 결과를 고찰하고자 한다. 대상 및 방법 : 1996년 3월부터 1997년 3월까지 슬괵건을 이용한 관절경적 전방십자인대 재건술을 시행받고 최단 12개월에서 최장 24개월(평균 16개월)까지 추시가 가능하였던 62례를 대상으로 하였으며 평균 연령은 27세이었다. 임상적 결과는 이학적검사 및 Lysholm Knee score와 Telos 기기를 이용한 술전, 술후 전방전위정도를 측정하여 평가하였다. 결과 : Lysholm Knee score는 술전 평균 57.0점이었으며 술후 추시상 평균 91.8점으로 증가하였다. 62명 전례에서 추시상 운동범위가 정상으로 회복되었고 파행이나 계단을 오르내리는데 어려움이 없었으며 보조기구없이 보행이 가능하였다. Lachman검사는 술전에는 경도(+)의 양성이 24례, 중등도(++)의 양성이 24례, 중도(+++)의 양성이 14례였으며 술후 추시상 48례에서 음성으로 전환되었으며 14례에서 경도의 양성이 관찰되었다. Telos 기기를 이용한 전방전위검사에서 정상 슬관절과의 차이가 20 lb 검사상 술전 평균 13.4mm였으나 술후 추시상 평균 4.7mm로 감소하여 전방전위 안정성이 회복되었으며 통계학적으로 유의한 차이를 보였다(P<0.05). 슬개골 주위 합병증으로는 슬개골 연발음이 18례(29.5%), 대퇴사두고근의 위축이 23례(36.5%)에서 관찰되었다. 수술중 기술상의 이유로 semifix 나사 삽입을 위한 유도핀의 삽입위치 불량이 2례에서 있었고 술후 semifix 나사의 비정상 위치가 3례에서 관찰되었다. 결론 : 슬괵건을 이용한 관절경적 전방십자인대 재건술은 슬관절의 기능적 안정성을 확보하는데 효과적인 수술방법이나 그 수술방법이 복잡하고 semifix 나사의 삽입위치 불량이나 술후 슬개골 주위의 합병증이 발생할 수 있으므로 유의하여야 할 것으로 생각된다.

  • PDF

구순구개열 환자에서 Locator® 유지장치가 장착된 milled titanium bar를 이용한 가철성 임플란트 피개 국소의치의 보철수복증례 (Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report)

  • 양상현;김경아;김자영;서재민
    • 대한치과보철학회지
    • /
    • 제53권3호
    • /
    • pp.207-214
    • /
    • 2015
  • 본 증례는 구순구개열 환자에서 상순의 반흔, 상악 잔존치조제의 과도한 흡수, 협소한 구개 및 상악골의 열성장을 동반한 3급 악간관계로 인해 통상의 가철성 국소의치 수복에 한계를 보이기 때문에 상악 무치악 부위에 4개의 임플란트를 식립 후, CAD/CAM 시스템으로 밀링한 titanium bar를 이용한 상악 가철성 임플란트 피개 국소의치를 계획하였다. 통상의 주조방법은 주조 후 수축을 하게 되지만 CAD/CAM 시스템으로 밀링한 titanium bar는 높은 정밀성과 경제성 그리고 가벼운 장점이 있다. 하지만 실제 임상에서 milled bar는 아주 균등하고 정확한 마찰결합을 얻기 힘들며 의치의 반복적인 착탈에 의해 마찰 유지력이 감소 할 수 있다. 이에 milled bar와 함께 사용할 수 있는 다양한 보조 유지장치(e.g. friction pin, $ERA^{(R)}$, $CEKA^{(R)}$, magnetics, $Locator^{(R)}$ 등)를 같이 사용함으로써 부가적인 유지력, 경제성 및 교체의 용이성 등을 추가적으로 얻을 수 있다. 본 증례에서 milled titanium bar의 상부면에 drill and tapping 방법으로 $Locator^{(R)}$ 유지장치를 연결하였다. milled bar에 screw hole을 형성하고 3개의 $Locator^{(R)}$ 유지장치를 20 Ncm으로 체결하여 추가적인 유지력을 확보하였다. 보철수복 후, 환자가 원하는 심미적인 안모, 저작 기능 및 의치 유지에 만족할 만한 결과를 얻었기에 이를 보고하고자 한다.