• 제목/요약/키워드: Pilot scale system

검색결과 358건 처리시간 0.027초

석탄 합성가스 제조를 위한 pilot급 가스화 시스템 운전특성 (Operation Characteristics of Pilot-Scale Gasification System for Coal Syngas Production)

  • 정석우;정우현;이승종;윤용승
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.429-432
    • /
    • 2007
  • Gasification has been regarded as a very important technology to decrease environmental pollution and to obtain higher efficiency, The coal gasification process converts carbon containing coal into a syngas, composed primarily of CO and $H_2$. And the coal syngas can be used as a source for power generation or chemical material production. This paper illustrates the operation characteristics and results of pilot-scale coal syngas production facilities. The entrained-bed pilot scale coal gasifier was operated normally in the temperature range of $1,300{\sim}1,400^{\cdot}C$, $2{\sim}3kg/cm^2$ pressure. And Indonesian KPC coal produced syngas that has a composition of $46{\sim}54$% CO, $20{\sim}26$% $H_2$, and $5{\sim}8$% $CO_2$.

  • PDF

Pilot 규모의 열분해 용융 소각 시스템에서의 열분해 및 연소 특성 연구 (A Study on the Pyrolysis and Combustion Characteristics of Solid Waste in a Pilot scale Pyrolysis Melting Incinerator)

  • 류태우;양원;박주원;김봉근;이기방;김희열;박상신;전금하
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.168-174
    • /
    • 2006
  • A pilot scale (200kg/hr) pyrolysis melting incineration system is designed and constructed in Korea Institute of Industrial Technology. The incineration process is composed of pyrolysis, gas combustion, ash melting, gas stabilization, waste heating boiler, and bag filter. For each unit process, experimental approaches have been conducted to find optimal design and operating conditions. Especially, a pyrolysis is very important process in that it is a way of energy recirculation and minimizing the waste products. This paper presents major results of the most efficient operating conditions in a pilot scale pyrolysis melting incinerator.

  • PDF

활성슬러지 공정에 의한 Kraft 펄프 폐수의 독성 제거 (Removal of Toxicity from Kraft Pulp Mill Effluents by Activated Sludge Process)

  • 김영관
    • 상하수도학회지
    • /
    • 제8권3호
    • /
    • pp.9-18
    • /
    • 1994
  • 활성슬러지 공정을 이용하여 Kraft 펄프공장에서 배출되는 유출수에 잔류하는 만성독성의 제거가능성을 평가하기 위하여 pilot plant를 운전하였다. 독성 이외에도 폐수내의 BOD, SS, resin과 fatty acids, 색도, 그리고 AOX와 같은 오염물질의 제거효과도 측정되었다. Pilot plant는 정상상태에서 약 10주 동안 운전되었으며 운전기간 동안의 평균 F/M 비율은 0.28, 그리고 sludge age는 8.4일로 계산되었다. 평균 MLSS 농도는 4,309mg/l이었으며 이중 휘발성 물질은 57%이었다. 운전기간 동안, BOD 제거계수(k)는 $30^{\circ}C$에서 8.2/일 이었으며 BOD 제거율은 full-scale 운전시보다 3~6% 정도 낮은 84%로 나타났다. 활성슬러지 유출수의 만성독성 시험은 Dinnel 방법과 BML 방법이 활용되었으며, 시험결과 pilot plant 활성슬러지 시스템에서도 효율적인 운전을 통하여 90% 이상의 독성제거가 가능함을 알 수 있었다. Pilot plant의 진 공정을 통해서 색도와 AOX의 제거는 매우 미미하였으나 resin과 fatty acids는 뛰어난 제거율을 나타내었다.

  • PDF

Development and Fabrication of Heating and Water Sparging Remediation System (HWSRS) for DNAPL-contaminated Groundwater Treatment

  • Lee, Ju-Won;Park, Won-Seok;Gong, Hyo-Young;Lee, Ae-Ri;Kim, Da-Eun;Baek, Seung-Chon;Lee, Jong-Yeol
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권6호
    • /
    • pp.32-37
    • /
    • 2013
  • The scope of this study was to develop, design, and build an ex-situ remediation system of using the heating and water sparging treatment for the highly volatile DNAPL (Dense Non-Aqueous Phase Liquid) contaminated groundwater, and to conduct pilot testing at the site contaminated with DNAPL. The TCE (Trichloroethylene) removal was at the highest rate of 94.6% with the water sparging at $70^{\circ}C$ in the lab-scale test. The pilot-scale remediation system was developed, designed, and fabricated based on the results of the lab-scale test conducted. During the pilot-scale testing, DNAPL-contaminated groundwater was detained at heat exchanger for the certain period of time for pre-heating through the heat exchanger using the thermal energy supplied from the heater. The heating system supplies thermal energy to the preheated DNAPL-contaminated groundwater directly and its highly volatile TCE, $CCl_4$ (Carbontetrachloride), Chloroform are vaporized, and its vaporized and treated water is return edback to the heat exchanger. In the pilot testing the optimum condition of the HWSRS was when the water temperature at the $40^{\circ}C$ and operated with water sparging concurrently, and its TCE removal rate was 90%. The efficiency of the optimized HWSRS has been confirmed through the long-term performance evaluation process.

Pilot Scal Multi-stage CSTR에서 전분질 원료의 연속 에탄올발효 (Continuous Ethanol Fermentation Using Starchy Raw Material in Pilot Scale Multi-stage CSTR)

  • 남기두;이인기;조훈호;최명호;김운식
    • 한국미생물·생명공학회지
    • /
    • 제20권3호
    • /
    • pp.324-328
    • /
    • 1992
  • 보다 경제적인 공정개발을 위하여 pilot scale의 다단 연속발효공정(multi-stage CSTR)에서 전분질 원료의 에탄올 발효를 연구하였다. 에탄올 발효를 쌀보리는 30일, cassava는 60이 동안 성공적인 운전을 할 수 있었으며, 원료는 저온 증자를 위하여 20-mesh sieve를 통과한 가루를 사용하였다. 최적화된 운전조건하에서 cassava의 overall productivity는 에탄올 농도 9.51(v/v)에서 $1.27g/{\ell}{\cdot}h$로써 종래 산업적 규모의 회분식 공정에서 얻는 것보다 약 2배 증가되었다.

  • PDF

Pilot 규모 산성가스 제거공정 운전 특성 (Operation Characteristics of Pilot-scale Acid Gas Removal Process)

  • 이승종;류상오;정석우;윤용승
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.533-536
    • /
    • 2009
  • The gasification technology is a very flexible and versatile technology to produce a wide variety products such as electricity, steam, hydrogen, Fisher-Tropsch(FT) diesels, Dimethyl Ether(DME), methanol and SNG(Synthetic Natural Gas) with near-zero pollutant emissions. Gasification converts coal and other low-grade feedstocks such as biomass, wastes, residual oil, petroleum coke, etc. to a very clean and usable syngas. Syngas is produced from gasifier including CO, $H_2$, $CO_2$, $N_2$, particulates and smaller quantities of $CH_4$, $NH_3$, $H_2S$, COS and etc. After removing pollutants, syngas can be variously used in energy and environment fields. The pilot-scale coal gasification system has been operated since 1994 at Ajou University in Suwon, Korea. The pilot-scale gasification facility consists of the coal gasifier, the hot gas filtering system, and the acid gas removal (AGR) system. The acid gas such as $H_2S$ and COS is removed in the AGR system before generating electricity by gas engine and producing chemicals like Di-methyl Ether(DME) in the catalytic reactor. The designed operation temperature and pressure of the $H_2S$ removal system are below $50^{\circ}C$ and 8 kg/$cm^2$. The iron chelate solution is used as an absorbent. $H_2S$ is removed below 0.1 ppm in the H2S removal system.

  • PDF

Pilot Sequence Assignment for Spatially Correlated Massive MIMO Circumstances

  • Li, Pengxiang;Gao, Yuehong;Li, Zhidu;Yang, Dacheng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권1호
    • /
    • pp.237-253
    • /
    • 2019
  • For massive multiple-input multiple-output (MIMO) circumstances with time division duplex (TDD) protocol, pilot contamination becomes one of main system performance bottlenecks. This paper proposes an uplink pilot sequence assignment to alleviate this problem for spatially correlated massive MIMO circumstances. Firstly, a single-cell TDD massive MIMO model with multiple terminals in the cell is established. Then a spatial correlation between two channel response vectors is established by the large-scale fading variables and the angle of arrival (AOA) span with an infinite number of base station (BS) antennas. With this spatially correlated channel model, the expression for the achievable system capacity is derived. To optimize the achievable system capacity, a problem regarding uplink pilot assignment is proposed. In view of the exponential complexity of the exhaustive search approach, a pilot assignment algorithm corresponding to the distinct channel AOA intervals is proposed to approach the optimization solution. In addition, simulation results prove that the main pilot assignment algorithm in this paper can obtain a noticeable performance gain with limited BS antennas.

남조류 제거를 위한 선회식 가압부상장치 현장 적용에 관한 연구 (A Study on Pilot Scale Cyclonic-DAF Reactor for Cyanobacteria Removal)

  • 오홍석;강선홍;남숙현;김은주;구재욱;황태문
    • 한국환경복원기술학회지
    • /
    • 제21권5호
    • /
    • pp.17-28
    • /
    • 2018
  • Cyclonic-dissolved air flotation(Cyclonic-DAF), an advanced form of pressure flotation, applies a structure that enables the forming of twirling flows. This in turn allows for suspended matter to adhere to microbubbles and float to the surface of a treatment tank during the process of intake water flowing through a float separation tank. This study conducted a lab-scale test and pursued geometrical modeling using computational fluid dynamics(CFD) to establish a pilot scale design. Based on the design parameters found through the above process, a pilot cyclonic-DAF system($10m^3/hr$) for removing algae was created. Upon developing the pilot-scale cyclonic-DAF system, a type of algae coagulant(R-119) was applied as the coagulant to the system for field testing through which the removal rates of chlorophyll-a and cyanobacteria were evaluated. The chlorophyll-a and harmful cyanobacteria of the raw water at region B, the field-test site, were found to be $177.9mg/m^3$ and 652,500cells/mL respectively. Treated waters applied with 60mg/L and 100mg/L of algae coagulant presented removal efficiencies of approximately 95% and 97%, respectively. The cyanobacteria cell number of the treated waters applied with 60mg/L and 100mg/L of algae coagulant both that were equal to or less than 1,000cells/mL and were below attention level criteria for the issuance of algae boundary.

Nitromethane 분해를 위한 초임계수 산화(SCWO) 공정 최적화 (Optimization of Supercritical Water Oxidation(SCWO) Process for Decomposing Nitromethane)

  • 한주희;정창모;도승회;한기도;신영호
    • Korean Chemical Engineering Research
    • /
    • 제44권6호
    • /
    • pp.659-668
    • /
    • 2006
  • 실험계획법을 이용하여 nitromethane을 초임계수산화(SCWO)로 분해시키는 공정의 최적화 연구를 진행하였다. Lab scale 반응설비를 이용하여 처리수의 COD와 T-N을 최소화하는 SCWO 공정의 최적 운전조건을 도출하였으며, scale-up 문제점을 파악하기 위해 SCWO pilot plant 실험 결과와 lab scale 최적화 실험 결과를 비교하였다. 처리수의 COD와 T-N을 최적화 목적 변수(KPOV)로 설정하였으며, 예비실험을 통해 반응 온도(temp)와 nitromethane과 암모니아수의 몰 비(NAR)를 주요 운전 변수(KPIV)로 설정하였다. 최적화 실험은 통계적 실험계획법인 중심합성설계법을 사용하였으며, 실험결과의 해석은 반응표면법을 활용하였다. 주 효과 분석결과 처리수의 COD는 Temp 증가에 따라 급격하게 감소하며, NAR 증가에 따라 약간 감소하는 것으로 나타났으며, T-N은 Temp 와 NAR 증가에 따라 감소하였다. Temp가 $420{\sim}430^{\circ}C$로 낮을 때에는 NAR 증가에 따라 T-N이 급격히 감소하였으나, $450^{\circ}C$ 이상으로 높을 때에는 큰 변화가 없었다. 최적화 실험 결과를 회귀분석 하여 처리수의 COD와 T-N 을 예측할 수 있도록 Temp와 NAR이 변수인 2차식으로 회귀식을 도출하였으며, 결정계수($r^2$)와 표준화잔차의 정규성을 분석하여 회귀식이 실험결과를 잘 모사하는 것을 확인하였다. 회귀식을 이용하여 COD < 2 mg/L, T-N<40 mg/L를 동시에 만족시키며 부식 위험이 적은 nitromethane 분해 최적 운전 조건은 Temp $450-460^{\circ}C$, NAR 1.03-1.08로 설정하였다. SCWO pilot plant를 이용하여 nitromethane 분해 최적 조건을 검증하고, SCWO 공정의 scale-up 문제점을 파악하는 연구를 실시하였다. SCWO pilot plant 실험 결과를 lab scale 반응설비에서 도출한 COD와 T-N의 회귀식과 비교한 결과 오차가 증가하지만 회귀식이 pilot plant 실험결과도 잘 나타내는 것을 확인할 수 있었다. Pilot plant 실험결과에 대한 회귀식의 적합성은 실험값과 예측값의 비교도와 표준화잔차의 정규성으로 검증하였다.

Feasibility Study on the Landfill Monitoring and Leakage Detection System

  • Park, Jun-Boum;Kwon, Ki-Bum;Oh, Myoung-Hak;Mishra, Anil Kumar
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2007년 가을학술발표회
    • /
    • pp.558-569
    • /
    • 2007
  • It is important to obtain real-time data from long-term monitoring of landfills and develop leachate leakage detection system for the integrated management of landfills. A novel real time monitoring system and early leakage detection system was suggested in this study. The suggested monitoring system is composed of two parts; (1) a set of moisture sensors which monitor the areas surrounding the landfill, and (2) a set of moisture and temperature sensors which monitor the landfill inside. For the assessment for landfills stabilization, real-time monitoring system was evaluated in dry and wet cell of pilot-site. In addition, the grid-net electrical conductivity measurement system was also suggested as early leakage detection system. In this study, the field applicability of suggested systems was evaluated through pilot-scale field tests. The results of pilot-scale field model tests indicate that the grid-net electrical conductivity measurement method can be applicable to the detection of landfill leachate at the initial stage of intrusion, and thus has a potential for monitoring leachate leakage at waste landfills.

  • PDF