• Title/Summary/Keyword: Pile loading test

Search Result 251, Processing Time 0.026 seconds

Permanent Deformations of Piles in Sand Under Cyclic Lateral Loads (모래지반에서 반복수평하중을 받는 말뚝의 영구변형)

  • Paik, Kyu-Ho;Park, Won-Woo
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.11
    • /
    • pp.63-73
    • /
    • 2010
  • Monopiles, used as one foundation option for offshore wind turbines, are usually subjected to great cyclic lateral loads due to wind and wave. In this study, model pile load tests were performed using calibration chamber and three model piles with different pile lengths in order to investigate the behavior of laterally cyclic loaded piles driven into sand. Model test results show that the first loading cycle generates a bigger displacement than the following ones, and the permanent displacement of piles by one loading cycle decreases with increasing the number of cycles. 1-way cyclic loading causes the permanent displacement in the same direction as cyclic loading, whereas 2-way cyclic loading causes the permanent displacement in the reverse direction of initial loading. It is also observed that the permanent displacement of piles due to cyclic lateral loads increases with decreasing relative density of soil and with increasing the magnitude of cyclic loads. However, it is insensitive to the earth pressure ratio of soil and embedded pile length. In addition, based on the model pile load test results, equations for estimation of the permanent lateral displacement and rotation angle of piles due to 1-way cyclic lateral loads are proposed.

Bearing Capacity Evaluation of Drilled Shaft for Top & Down Method (탑다운 기초 현장타설말뚝의 지지력 평가)

  • Cho, Chun-Whan;Kim, Hong-Mook;Kim, Woong-Kyu;Kwon, Se-Oh;Sung, Byung-Wan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.58-65
    • /
    • 2004
  • Recently, the top & down method with drilled shafts as a foundation of high rise building is often adopted for the purpose of construction period reduction and construction cost effectiveness. It is common to omit the loading test as a Quality assurance on account of the high capacity of drilled shafts for the top & down method. It seems that the capacity of drilled shaft in recent top & down method is beyond that of conventional loading test method.However, the quality assurance for the drilled shaft as foundation of high rise building becomes much more important since the drilled shaft should bear much higher working load. It may be a small scale test pile could be an alternative as a quality assurance for the drilled shaft with high capacities. Through a case study, this paper gives an idea for solving the limitation of the conventional loading test method for the quality assurance of drilled shaft with high capacities. In particular, this paper analyzed the scale effect for a small drilled shaft installed into bedrock, which could be used for an alternative.

  • PDF

Analysis of Load-Settlement Behaviour Characteristics of Granular Compaction Piles from the Model Tests (모형실험에 의한 조립토 다짐말뚝의 하중-침하 관련 거동특성 분석)

  • Kim, Hong-Taek;Kang, Yun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.4
    • /
    • pp.33-45
    • /
    • 2004
  • In the present study, more systematic laboratory model tests under various conditions are carried out to investigate load-sharing characteristics among the granular pile and adjacent soils and bearing capacity characteristics with different pile lengths. Further to evaluate effects of both a loading area and a spacing of pile installation on the bearing capacity and bearing capacity characteristics of each pile in group, model test results are also analyzed for the purpose of an efficient design of granular compaction piles. From the analysis of the model test results, it is found that the ultimate capacity of granular compaction group piles increases with a decrease in the installation distance among granular piles. It is also found that the dominant failure mode of the granular compaction piles is bulging failure. It is further realized that the length of a granular pile could not significantly affect on the ultimate granular pile capacity.

  • PDF

Cyclic behavior of connection between footing and concrete-infilled composite PHC pile

  • Bang, Jin-Wook;Hyun, Jung Hwan;Lee, Bang Yeon;Kim, Yun Yong
    • Structural Engineering and Mechanics
    • /
    • v.50 no.6
    • /
    • pp.741-754
    • /
    • 2014
  • The conventional PHC pile-footing connection is the weak part because the surface area and stiffness are sharply changed. The Composite PHC pile reinforced with the transverse shear reinforcing bars and infilled-concrete, hereafter ICP pile, has been developed for improving the flexural and shear performance. This paper investigates the cyclic behavior and performance of the ICP pile-footing connection. To investigate the behavior of the connection, one PHC and two ICP specimens were manufactured and then a series of cyclic loading tests were performed. From the test results, it was found that the ICP pile-footing connection exhibited higher cyclic behavior and connection performance compared to the conventional PHC pile-footing connection in terms of ductility ratio, stiffness degradation and energy dissipation capacity.

Lateral Resistance Analysis of Single Pile Using Strain Wedge Model in Sand (모래지반에서 쐐기모델을 이용한 단독말뚝의 수평저항력 해석)

  • Bae, Jong-Soon;Kim, Ji-Seong;Kim, Sung-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.11
    • /
    • pp.39-46
    • /
    • 2010
  • The magnitude of the lateral resistance that resists the lateral movement of the pile is controlled by the amount of the pile movement and the strength and stiffness of soil. In this paper, we proposed an equation which produces the lateral resistance of the laterally loaded single pile using the strain wedge model of the soil deformation. The results of this equation is compared with results of model test, field test, p-y curve and other methods. It is found that the result of proposed equation is smaller than the result of model test. The results of loading test considerably coincide with those of proposed equation; however, a few of deviations are generated as the displacement of pile head increases. Moreover, coincidences exist between the results of the proposed equation and those of finite difference method.

Analysis of Laterally Loaded Single Piles using Pressuremeter Test (공내재하시험을 이용한 수평하중을 받는 단말뚝의 해석)

  • Lee, Yong-An;Lee, Ju-Hyung;Chung, Moon-Kyung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1051-1060
    • /
    • 2010
  • In this study, the pressuremeter test (PMT) and the standard penetration test (SPT) were performed on the lateral pile loading tests site to evaluate the coefficient of subgrade reaction, which is used for load-deformation behavior analysis of laterally loaded piles by elastic subgrade reaction method. As a result, widely used empirical formulas of the coefficient of subgrade reaction by N values of SPT is evaluated conservatively lateral behavior of piles. While the method of directly used PMT results and evaluation method of the coefficient of subgrade reaction considering deformation moduli of soil and a pile diameter that is able to estimate very similar to actual load-deformation behavior of laterally loaded piles in deformation range of 0.5%-1.0% of a pile diameter.

  • PDF

A proposal for the analysis of the PDA testing results of the extra-long piles (초장대말뚝의 동재하시험 해석방안)

  • Lee, Myung-Whan;Hong, Hun-Sung;Kim, Sung-Hoi;Jun, Young-Suk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1269-1278
    • /
    • 2006
  • These days the construction of extra-long piles increases. It is not unusual to install piles whose length exceed 45m. In such cases, the estimated value of negative skin friction becomes larger, often larger than the design load. In order to be sure of the safety of the super structure, the magnitude of the positive skin friction and the base bearing capacity should be known. In practice dynamic pile loading tests using PDA is the only possible measure to meet this requirement. However the analysis of dynamic pile loading test for such extra-long piles requires a thorough understanding of the pile-soil behaviour. In this paper, a new method to evaluate the positive skin friction and end bearing capacity from the normally performed PDA test is proposed. The proposed method was verified by performing specially designed pilot testings.

  • PDF

Analysis of Loading Translation Behavior for Drilled Shafts Modeling Pile through Lateral Loading Test (현장타설 모형말뚝의 수평재하시험을 통한 하중전이 거동 분석)

  • Park, Jun-Beom;Kim, Hong-Lark;Yoon, Myung-June;Heo, Seong-Jun;Kim, Hong-Taek
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1011-1016
    • /
    • 2009
  • In this study, to performed laboratory model tests in order to verify on load transfer condition of drilled shaft under lateral loading. To conducted model test on polystyle drilled shaft under multi layer ground conditions. In model test, to measured the strain of drilled shaft and displacement under later loading. In order to verify on model test results, to conduct the numerical analysis.

  • PDF

Seismic analysis of turbo machinery foundation: Shaking table test and computational modeling

  • Tripathy, Sungyani;Desai, Atul K
    • Earthquakes and Structures
    • /
    • v.12 no.6
    • /
    • pp.629-641
    • /
    • 2017
  • Foundation plays a significant role in safe and efficient turbo machinery operation. Turbo machineries generate harmonic load on the foundation due to their high speed rotating motion which causes vibration in the machinery, foundation and soil beneath the foundation. The problems caused by vibration get multiplied if the soil is poor. An improperly designed machine foundation increases the vibration and reduces machinery health leading to frequent maintenance. Hence it is very important to study the soil structure interaction and effect of machine vibration on the foundation during turbo machinery operation in the design stage itself. The present work studies the effect of harmonic load due to machine operation along with earthquake loading on the frame foundation for poor soil conditions. Various alternative foundations like rafts, barrette, batter pile and combinations of barrettes with batter pile are analyzed to study the improvements in the vibration patterns. Detailed computational analysis was carried out in SAP 2000 software; the numerical model was analyzed and compared with the shaking table experiment results. The numerical results are found to be closely matching with the experimental data which confirms the accuracy of the numerical model predictions. Both shake table and SAP 2000 results reveal that combination of barrette and batter piles with raft are best suitable for poor soil conditions because it reduces the displacement at top deck, bending moment and horizontal displacement of pile and thereby making the foundation more stable under seismic loading.

Evaluation of Load Transfer Characteristics of Barrette Pile Based on Bi-directional Loading Tests (양방향 재하시험결과를 활용한 바렛말뚝의 하중전이특성 평가)

  • Park, Seong Wan;Lim, Dae Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.2C
    • /
    • pp.41-49
    • /
    • 2009
  • Due to the increased size of civil infrastructure and the cost of materials, the needs exists for utilizing large sized cast-inplace piles in lieu of conventional precast piles. Among them, the barrette pile has become more commonly used in fields where a diaphragm wall is the retaining wall, to improve workability and economical efficiency, and to ensure hole stability under deep soil layers. In this paper, the bearing capacity and displacement characteristics of the barrette pile are evaluated by using the bi-directional loading test data obtained from four different sites. In addition, the design value of pile shaft resistance, ${\beta}$, is assessed with previous literatures and load transfer analysis. Finally, numerical analyses were performed to analyze the load-displacement behavior, and the interface effect on the piles, using the 3-dimensional finite element method.