• Title/Summary/Keyword: Piezoelectric Transducers

Search Result 217, Processing Time 0.027 seconds

The Principles and Metrical Applications of Immunocsensors (면역센서의 원리와 의학적 응용)

  • 김의락;백세환
    • KSBB Journal
    • /
    • v.17 no.2
    • /
    • pp.121-136
    • /
    • 2002
  • Immunosensors are of great interest because of their potential utility as specific, simple, label-free, direct detection means and provision of reduction in size, cost and time of analysis comparing with conventional immunoassay. In the last two decades, many reports have been published on the use of immunosensors for a wide range of applications to clinical diagnostics, pharmaceutical chemistry, environmental monitoring, biotechnology and food industries. There are also numerous transduction techniques developed such as electrochemical techniques, piezoelectric crystal, and surface plasmon resonance receiving much attention for the direct monitoring of immune reactions at solid surfaces. In this article, the principles, characteristics, structures, fonctions and clinical applications of immunosensors were reviewed

Experimental Study on Upstream Fueled Cavity Flame-Holder Scramjet Engine (상류 분사 공동 화염 지지부를 가지는 스크램제트 엔진에 관한 실험적 연구)

  • Jeung, In-Seuck;O'Byrne, Sean;Houwing, A.F.P.;Jeong, Eun-Ju
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.197-204
    • /
    • 2006
  • The model cavity scramjet engine experiments are carried out using T3 free-piston shock tunnel. Upstream hydrogen fuel is injected before the cavity with different injection pressure. OH planar laser-induced fluorescence is used to investigate the combustion zone and piezoelectric pressure transducers are used to define the pressure rise due to the combustion. Main combustion region is a mixing layer which is between air and fuel. Also high OH fluorescence signal is appeared in the shear layer above the cavity in high equivalence ratio. From the OH signal in the cavity, this fuel injection system can be a role as a flame- holder.

  • PDF

Acoustic waves in a high-frequency ultrasonic cleaner (고주파 초음파 세정기의 파동 해석)

  • 최성훈;김진오;김용훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.656-661
    • /
    • 1997
  • Ultrasonic cleaning at high frequency near 1MHz, called megasonic cleaning, is commonly used to remove particles less than 1.mu.m by generating accelerations on them. Ultrasonic waves generated from piezoelectric transducers are transmitted through a non-metallic inner container which is used to isolate a cleaning object from metallic ions. The transmission characteristics of a double-structured megasonic cleaner on the variations of parameters such as the thickness and oblique angle of a inner container, chemical ratio of a cleaning agent and temperature and transmittivity are investigated. The results are used to determine an optimum cleaning condition.

  • PDF

A Study on PZT-5A Probe for Nondestructive Inspection (비파괴검사를 위한 PZT 5A 탐촉자에 관한 연구)

  • 황현석;정규원;이종덕;송준태
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.245-248
    • /
    • 1996
  • In this study, piezoelectric transducers were designed and manufactured using PZT-5A which had relatively high electromechanical coefficient, NDT system was developed with was able to inspect automatically using stepping motors, PC-Lab, and PC-Scope The optimum design conditions for NDT were presented and verified comparing PZT-5A probes with comercial probes. It was proved with comercial probes. It was proved by simulation and experiments that Epoxy is good as material of matching and backing layers. The envelope was reduced 60% with matching layer and 76% with matching and backing layer. NDT was successfully carried out for aluminum test pieces. Distance error of PZT-5A probe was 2.8%.

  • PDF

Incidence Angle Estimation by the Tonpilz Type Underwater Acoustic Vector Sensor with a Quadrupole Structure (Quadrupole 구조를 가진 Tonpilz형 수중 음향 벡터 센서를 이용한 입사각 추정)

  • Lim, Youngsub;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.8
    • /
    • pp.569-579
    • /
    • 2012
  • Typical Tonpilz type underwater acoustic transducers making use of piezoelectric ceramics detect the magnitude of an acoustic pressure, a scalar quantity, and convert this pressure into a proportional output voltage. The scalar sensor has no directional sensitivity. In this paper, we have proposed a new vector sensor based on the Tonpilz transducer structure, which is sensitive to both the magnitude and the azimuthal direction of an acoustic wave. Validity of this new design has been confirmed with analytic equations and finite element analyses.

Detection of onset of failure in prestressed strands by cluster analysis of acoustic emissions

  • Ercolino, Marianna;Farhidzadeh, Alireza;Salamone, Salvatore;Magliulo, Gennaro
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.4
    • /
    • pp.339-355
    • /
    • 2015
  • Corrosion of prestressed concrete structures is one of the main challenges that engineers face today. In response to this national need, this paper presents the results of a long-term project that aims at developing a structural health monitoring (SHM) technology for the nondestructive evaluation of prestressed structures. In this paper, the use of permanently installed low profile piezoelectric transducers (PZT) is proposed in order to record the acoustic emissions (AE) along the length of the strand. The results of an accelerated corrosion test are presented and k-means clustering is applied via principal component analysis (PCA) of AE features to provide an accurate diagnosis of the strand health. The proposed approach shows good correlation between acoustic emissions features and strand failure. Moreover, a clustering technique for the identification of false alarms is proposed.

An Evaluation of the Uncertainty of Pressure Measurement Systems (압력 측정 시스템의 불확도 평가)

  • 최주호;홍성수
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.15-23
    • /
    • 2002
  • Uncertainty components and evaluation of the system of pressure measurement are presented in this paper. Since early in 1980s, measurement uncertainty is getting more important due to ISO/IEC 17025, which is established for international test and calibration laboratories. Up to now it is true that accuracy, precision, error and etc. have been commonly used in industry to define the amount of error to the products and equipment, but these terms ought to be united into uncertainity in the future. This paper describes how to indicate measurement uncertainty and types of measurement errors, and then shows the evaluation result of measurement system using piezoelectric pressure transducers.

Design of High Efficiency Power Supply and Power Amplifier for Ultrasonic Parametric Array Transducer (초음파 파라메트릭 어레이 트랜스듀서용 고효율 전원 및 전력 증폭기 설계)

  • Kim, Jin-Young;Choi, Seung-Soo;Kim, In-Dong;Moon, Won-Kyu
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.149-150
    • /
    • 2015
  • 압전 마이크로머신 초음파 트랜스듀서(Piezoelectric micro-machined ultrasonic transducers)는 DC 바이어스 전압을 인가해야 구동되는 특성을 가지고 있다. 따라서 초음파 트랜스 듀서를 구동하기 위한 전력증폭기는 DC 바이어스 전압이 요구되므로 기존의 전력증폭기에 비해 효율이 매우 낮아지게 된다. 이를 해결하기 위해 본 논문에서는 압전 마이크로머신 초음파 트랜스듀서를 구동하기 위한 고효율 전력증폭기를 제안한다. 전력증폭기는 AMP부와 전원부로 나뉘며, AMP부는 Class B Amp를 사용하여 높은 증폭 선형성을 갖는다. 전원부는 Amp를 구동하기위한 DC-DC converter가 에너지 회수 동작을 하므로 전력증폭기의 효율을 높일 수 있다. 본 연구에서는 압전 마이크로머신 초음파 트랜스듀서를 구동하기 위한 전력증폭기 회로를 제시하고 시뮬레이션과 실험을 통해 동작 특성을 검증한다.

  • PDF

A research on Dynamic characteristic of Submerged pipe ; Support, Flange, Upper pump (수위변화에 따른 파이프 시스템의 진동 특성 변화에 대한 연구)

  • Jung, Hwee Kwon;Kim, Jong Yoon;Park, Gyuhae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.699-705
    • /
    • 2013
  • This paper presents vibration testing, control, and finite element analysis of a piping system, which is subjected to the changes in fluid levels. Nuclear power plants typically employ a cooling system that uses sea water. These systems are subjected to dynamic characteristic changes caused by sea-level variations, which introduces failures of cooling system components. Therefore in this study, analytical and experimental studies were performed to understand the effect of sea-level changes on the dynamic characteristics of piping systems. It was shown that, as the sea-level increases, pipe's natural frequencies decreases in relation to its mode shape. A 1/14 scale model was also built to compare the results obtained by the analytical study. A good agreement between experiment and analytical studies were observed. Finally, an on-line resonant frequency identification system was proposed and developed, which utilizes piezoelectric transducers as sensors and actuators, in order to avoid catastrophic failure of piping systems.

  • PDF

Two-Dimensional Numerical Modeling and Simulation of Ultrasonic Testing

  • Yim, Hyun-June;Baek, Eun-Sol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.6
    • /
    • pp.649-658
    • /
    • 2002
  • As an attempt to further improve the reliability and effectiveness of ultrasonic testing (UT), a two-dimensional numerical simulator of UT was developed. The simulator models the wave medium (or test object) using the mass-spring lattice model (MSLM) that consists of mass-points and springs. Some previous simulation results, obtained by using MSLM, are briefly reviewed in this paper, for propagation, reflection, and scattering of ultrasonic waves. Next, the models of transmitting and receiving piezoelectric transducers are introduced with some numerical results, which is a main focus of this paper. The UT simulator, established by combining the transducer models with the MSLM, was used to simulate many UT setups. In this paper, two simple setups are considered as examples, and their simulated A-scan signals are discussed. The potential of the MSLM, transducer models, and the UT simulator developed in this study to be used in the actual UT is confirmed.