• Title/Summary/Keyword: Physiological measurements

Search Result 247, Processing Time 0.033 seconds

Determination of Heavy Metals in Sea Salt Using Anodic Stripping Voltammetry

  • Kim, Yong Hoon;Kim, Giyoung
    • Food Engineering Progress
    • /
    • v.21 no.2
    • /
    • pp.180-186
    • /
    • 2017
  • Salt, as food, is the most essential element for human survival due to its significant physiological functions. Here, we report the simultaneous detection of Pb and Cd in sea salt by square wave anodic stripping voltammetry (SWASV). Stripping voltammetric measurements were conducted using a manufactured rotating disk electrode system (MRDES). The detection limit was $3.6{\pm}0.18{\mu}gL^{-1}$ for Pb and $3.9{\pm}0.37{\mu}gL^{-1}$ Cd in NaCl solution. When the pH increased from 5.5 to 8.5, the peak currents of Pb and Cd decreased. At a pH of 8.3, the ratio of the current drop compared with that at a pH of 5.5 was 0.6 for Pb and 0.73 for Cd. The concentrations corrected by the current drop are in agreement with the concentrations obtained with ICP (inductively coupled plasma). This system demonstrates the reliable detection of heavy metals in aqueous media and, at a high $Na^+$ concentration, the successful application for the determination of Pb and Cd in sea salts.

Comparison of alarm systems for advanced control room

  • Lee, H.C.;Oh, I.S.;Sim, B.S.;Koo, I.S.;Kim, J.T.;Lee, K.Y.;Park, J.K
    • Proceedings of the ESK Conference
    • /
    • 1997.10a
    • /
    • pp.303-309
    • /
    • 1997
  • This study is carried out to investigate performance differences between two alarm presentation methods from the viewpoint of human factors and to provide items to be improved. One of the alarm display methods considered in this study displays alarm lists on VDT combined with hardwired alarm panels. The other method displays alarms on plant mimic diagrams of VDT. This alarm display method has other features for operator aid with which operator can get detailed information on the activated alarm in the mimic diagrams, and the capability for alarm processing such as alarm reduction and prioritization. To compare the twodisplay methods, a human factor experiment was performed with a plant simulator in the ITF(Integrated Test Fcility) that plant operators run for 4 event scenarios. During the experiment, physiological measurements, system and operator action log, and audio/video recordings were collected. Operators' subjective opinion was collected as well after the experiment. Time, error rate and situation awareness were major human factor criteria used for the comparison during the analysis stage of the experiment. No statistical significance was found in the results of our statistical comparison analysis. Several findings were identified, however, through the analysis of subjective opinions.

  • PDF

Development of Personalized Respiratory Training Device with Real-time Feedback for Respiratory Muscle Strengthening

  • Merve Nur Uygun;Yeong-geol Bae;Yejin Choi;Dae-Sung Park
    • Physical Therapy Rehabilitation Science
    • /
    • v.12 no.3
    • /
    • pp.251-258
    • /
    • 2023
  • Objective: The practice of breathing exercises involves altering the depth and frequency of respiration. Strengthening respiratory muscles plays a crucial role in maintaining overall health and well-being. The efficiency of the respiratory system affects not only physical activity but also various physiological processes including cardiovascular health, lung function, and cognitive abilities. The study evaluated the reliability of the developed device for inspiratory/expiratory training using pressure sensors and Bluetooth connectivity with a smartphone application. Design: Design & development research Methods: The research methodology involved connecting a custom-made respiratory sensor to an IMT-PEP BIC Breath device. Various pressure conditions were measured, and statistical analyses were performed to assess reliability and consistency. Results showed high Intraclass Coefficient Correlation (ICC) values for both inspiratory and expiratory pressures, indicating strong test-retest reliability. The device was designed for ease of use and wireless monitoring through a smartphone app. Results: This study conducted at expiratory pressure confirmed the proper operation of the IMT/PEP breathing trainer at the specified pressure setting in the product. The pressure sensor demonstrated high test-retest reliability with an ICC value of 0.999 for both expiratory and inspiratory pressure measurements. Conclusions: The developed respiratory training device measured and monitored inspiratory and expiratory pressures, demonstrating its reliability for respiratory training. The system could be utilized to record training frequency and intensity, providing potential benefits for patients requiring respiratory interventions. Further research is needed to assess the full potential of the device in diverse populations and applications.

The Effects of CO2 Enrichment on the Radial Growth of Pinus densiflora

  • En-Bi CHOI;Hyemin LIM;Jeong-Wook SEO
    • Journal of the Korean Wood Science and Technology
    • /
    • v.52 no.3
    • /
    • pp.289-299
    • /
    • 2024
  • The current study aimed to investigate the impact of CO2 enrichment on the width of annual tree rings, earlywood and latewood, and the area of annual growth of Pinus densiflora Siebold & Zucc. grown in open-top chamber (OTC). To this end, two CO2 enrichment cases were considered, namely 1.4 × increment (560 ppm in OTC-II) and 1.8 × (720 ppm in OTC-III) were compared with the current atmosphere (400 ppm in OTC-I). The CO2 enrichment conditions for a period of 12 years (2010-2021) were considered, and all measurements were done through image analysis. The study showed that the increment in CO2 concentrations positively affected the tree growth. The measurement data from the trees in OTC-III were considerably higher than those from OTC-I, whereas those from OTC-II were slightly higher than those from OTC-I. Decreasing patterns of the measured widths and area in 6-7 years after the beginning of CO2 enrichment was found for all the OTCs. These patterns were possibly due to changes in the physiological features, such as aging. The findings of the present study can have potential uses as fundamental data for forest management considering CO2 concentrations.

Effects of Using Carbon Dioxide on Heart Rate and Arterial Blood Pressure during Laparoscopic Ovariohysterectomy in Dogs (개에서 복강경을 이용한 난소자궁절제술시 $CO_2$가스에 의한 기복증이 심박수와 동맥혈압에 미치는 영향)

  • Cho, Seong-Su;Kim, Young-Ki;Park, Se-Jin;Lee, Seung-Yong;Lee, Scott-S.;Lee, Hee-Chun;Lee, Hyo-Jong;Chang, Hong-Hee;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.28 no.1
    • /
    • pp.40-45
    • /
    • 2011
  • Cardiovascular changes caused by $CO_2$ pneumoperitoneum during laparoscopic ovariohysterectomy (LOVH) were measured in nine healthy mixed breed dogs ($16.7{\pm}4.6kg$). The dogs were premedicated with the combination of atropine, acepromazine, and butorphanol. General anesthesia was induced with propofol and maintained with isoflurane in oxygen. Controlled ventilation maintained partial pressure of end-tidal $CO_2$ between 35-45 mmHg. The $CO_2$ pneumoperitoneum was maintained at a constant pressure of 12 mmHg and the dog was placed in the $15^{\circ}$ Trendelenburg position as LOVH was performed. Dorsal pedal artery was catheterized for measurements of heart rate (HR) and invasive arterial blood pressure (IBP). Prior to the intraperitoneal insufflation, baseline measurements of HR and IBP were made every minute for a total of 10 min. Then, measurements of HR and IBP were made every 5 min following intraperitoneal insufflation and were also made every 5 min following desufflation for a total of 10 min. The $CO_2$ pneumoperitoneum during LOVH resulted in a significant (P < 0.05) increase in systolic arterial blood pressure at the time of the onset of insufflation. In addition, diastolic and mean arterial blood pressure increased significantly (P < 0.05) at the time of the onset of insufflation and 5 min following insufflation. The mean heart rate did not change significantly during LOVH. Although IBP showed sharp initial rise following the $CO_2$ pneumoperitoneum, the changes were within physiological acceptable limits in these healthy, ventilated dogs.

Studies on the Indirect Measuring Method of the Maximum Voluntary Ventilation (최대환기능의 간접측정법에 관한 연구)

  • Park, Hae-Kun;Kim, Kwang-Jin;Sung, Hae-Sook;Jeon, Byung-Sook
    • The Korean Journal of Physiology
    • /
    • v.11 no.2
    • /
    • pp.45-50
    • /
    • 1977
  • The maximum voluntary ventilation (MVV) is one of the most widely used pulmonary function test, but its measuring method was very difficult and unreliable. However, it is need to get more easy and simple measuring method of MVV. Therefore, this study was attempted to get more easy and simple measuring method of MVV by means of the forced expiratory volume $(FEV_{T})$. The young and healthy 1,000 Korean students(592 male and 408 female) were cheesed for this purpose and whose ages were from 8 to 20 years. A spirometer (9L, Collins Co.) was used for the MVV and FEV, and they were measured 3 times at standing position, and the highest value was used. In the measurements, the subjects for MVV were asked for the breath as fast and deeply as possible for 12 seconds, and for FEV were asked for the rapid and forceful exhalation after a maximal inhalation (forced expiratory curve). In the FEV measurements toward the end of the expiration, the subjects were exhaused to continue the effort until no further gas was expired. During these measurements, the investigator stood by the subject to give a constant encouragement. FEV were calculated in the volume exhaled during the one-half $(FEV_{0{\cdot}5,}\;ml)$, the first second $(FEV_{1{\cdot}0,}\;ml)$ and the percentage of the total vital capacity exhaled during the one-half second $(FEV_{0{\cdot}5,}\;%)$. The results are summarized as follows: 1) The values of MVV were increased linearly with ages until 20 in both sexes. The values of male at the age of 20 was $168.2{\pm}2.5L/min$, and female at the age of 17 was $112.3{\pm}3.0L/min$, respectively. 2) The values of FEV (ml) were increased linearly with ages until 20 in both sexes. The values of $FEV_{0{\cdot}5}$ were $2,797{\pm}65.7ml$ in the male of 20 years and were $2,088{\pm}54.6ml$ in the female of 17 years, and of $FEV_{1{\cdot}0$ were $4,119{\pm}68.2ml$ in the male of 20 years and were $2,897{\pm}65.9ml$ in the female of 17 years, respectively. 3) The correlation coefficients between MVV and $FEV_{0{\cdot}5}\;or\;FEV_{1{\cdot}0$ (ml) were 0.82 or 0.85 in the male, and 0.77 or 0.79 in the female, respectively. 4) The prediction formulae for MVV to be derived from above results were: For male: MVV (L/min) =7.19+$0.05{\times}FEV_{0\cdot5}(ml)$, MVV (L/min)=11.25+$0.04{\times}FEV_{1\cdot0}(ml)$ For female: MVV (L/min)=16.03+$0.05{\times}FEV_{0\cdot5}(ml)$, MVV (L/min)=9.47+$0.03{\times}FEV_{1\cdot0}(ml)$.

  • PDF

Measurements of Setup Error and Physiological Movement of Liver by Using Electronic Portal Imaging Device in Patients with Hepatocellular Carcinoma (간암환자에서 Electronic Portal Imaging Device(EPID)를 이용한 자세 오차 및 종양 이동 거리의 객관적 측정)

  • Keum Ki Chang;Lee Sang-wook;Shin Hyun Soo;Kim Gwi Eon;Sung Jinsil Seong;Lee Chang Geol;Chu Sung Sil;Chang Sei-Kyung;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.107-113
    • /
    • 2000
  • Purpose : The goal of this study 닌as to improve the accuracy of three-dimensional conformal radiotherapy (3-D CRT) by measuring the treatment setup error and physiological movement of liver based on the analysis of images which were obtained by electronic portal imaging device (EPID). Materials and Methods : For 10 patients with hepatocellular carcinoma, 4-7 portal images were obtained by using EPID during the radiotherapy from each patient daiiy. We analyzed the setup error and physiological movement of liver based on the verification data. We also determined the safety margin of the tumor in 3-D CRT through the analysis of physiological movement. Results : The setup errors were measured as 3mm with standard deviation 1.70 mm in x direction and 3.7 mm with standard deviation 1.88 mm in y direction respectively. Hence, deviation were smaller than 5mm from the center of each axis. The measured range of liver movement due to the physiological motion was 8.63 mm on the average. Considering the motion of liver and setup error, the safety margin of tumor was at least 15 mm. Conclusion : EPID is a very useful device for the determination of the optimal margin of the tumor, and thus enhance the accuracy and stability of the 3-D CRT in patients with hepatocellular carcinoma.

  • PDF

Effects of Physiological Factors and Lifestyles on Bone Mineral Density in Postmenopausal Women (생리적 요인과 생활습관이 폐경 후 여성의 골밀도에 미치는 영향)

  • Sung, Chung-Ja;Choi, Yun-Hee
    • Journal of Nutrition and Health
    • /
    • v.40 no.6
    • /
    • pp.517-525
    • /
    • 2007
  • This study was performed to assess the effects of physiological factors and lifestyles on bone mineral density (BMD) in 64 postmenopausal women. Sixty four subjects were selected out of 223 postmenopausal women in Seoul and Kyunggido. The BMD of the lumbar spine (L2 ${\rightarrow}$ L4) and femoral neck were measured dual energy X-ray absorptiometry (DEXA). Subjects were assigned to one of three groups such as normal (T-score > -1, n = 20), osteopenia (-2.5 < Tscore ${\leq}$ -1, n = 24), and osteoporosis (T-score ${\leq}$ -2.5, n = 20). Anthropometric measurements and questionares were administered to these women. The mean age, height, weight and BMI were 62.09 yrs, 153.78 cm, 56.09 kg and 23.70 $kg/m^2$ respectively. The BMDs of lumbar spines (L2 ${\rightarrow}$ L4), femoral neck were 0.84 $g/cm^2$, 0.71 $g/cm^2$ respectively. Years after menopause and age of last delivery of the osteoporosis and osteopenia group were significantly longer than the normal group (p < 0.05). The hours of exercise and outdoor activity of the normal group were longer than the osteoporosis and osteopenia group, but there were no significant differences among the three groups. The BMDs of these two sites were positively correlated with weight, BMI, hip and body fat and negatively correlated with LBM, TBW. These results show there are no consistent effects on bone mineral density, adjusting for age and BMI, of physiological factors and lifestyles in postmenopausal women. Therefore. this study confirmed that one of the most effective ways to minimize bone loss in postmenopausal women would be to maintain an adequate body weight.

Effect of Wear Training on Temperature Adaptability of the Obese Children (비만아동의 온도적응성에 대한 착의훈련 효과)

  • Jeong, Woon-Seon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.3 s.151
    • /
    • pp.407-411
    • /
    • 2006
  • This study was carried out to investigate the physiological responses of obese children after a short-term wear training and education. A ten-week program was conducted on thirteen obese elementary school children of six boys and seven girls in the 4th to the 6th grade. During the program, the children were instructed to measure daily ambient temperature and weight of their clothing. Physiological responses of the sedentary children in 100$\%$ cotton short sleeved t-shirt (0.13clo) and T/C short pants(0.09clo) were observed in the climatic chamber of 23.0$\pm$0.5$^{circ}C$ and 50$\pm$5$\%$RH before and after program. During the experiment, internal ear temperature ($T_{ear}$), seven site skin temperatures, systolic blood pressure, diastolic blood pressure, heart rate, and subjective responses of thermal comfort and thermal sensation were measured every 5minutes. Mean skin temperature($T_{sk}$) and mean arterial pressure(MAP) were calculated. Obtained data are statistically analyzed and main results are as follows. There was highly significant correlation between the ambient temperature and the total clothing weight. $T_{ear}$ and MAP were reduced in the post-program compared to the pre-program. The obese girls felt slightly warmer than the obese boys and the girls were likely to prefer lower ambient temperature in the post-program than the pre-program. It was concluded that the 10 week wear training is apt to be more applicable to the obese girls than the obese boys. However, a more comprehensive study including. diverse measurements of deep body temperature with a long-term training would be needed to clarify the improvement of temperature adaptability in the obese children.

Effect of human biosignal according as foot was heating with hot water (발 부분 온수 열자극시 인체 현상에 미치는 영향)

  • Lee, Woo-Cheol;Min, Kyeug-Kee;SaKong, Sug-Chin
    • 전자공학회논문지 IE
    • /
    • v.43 no.1
    • /
    • pp.5-15
    • /
    • 2006
  • In this paper, we measured the biosignal using hot-water system(STYX ford202) on foot. The biosignal transition data is observed from hot-water thermotherapy on foot. pre and post demonstration conditions under 43$^{\circ}C$ and 45$^{\circ}C$ are checked about 9 physiological factors for 10 persons and 10 days. (Checking Time: pre-test, post-test(5, 10, 15, 20 minutes)). The biosignal transition of demonstration's results showed as belows; Forehead Temperature($^{\circ}C$): -0.69 $\pm$ 0.01 dec, Leg Temperature($^{\circ}C$): 1.51 $\pm$ 0.22 inc, Blood Flow($m\ell/min$): 1.18 $\pm$ 0.50 inc, Blood Pressure(mmHg): (max) -1.49$\pm$ 2.81, (min) -0.06 $\pm$ 0.13 dec, Heart Rate(bpm): 6.97 $\pm$ 0.72 inc, Blood Sugar($mg/d\ell$) : -2.41 $\pm$ 1.55 dec, Oxygen Saturation(%): 1.34 $\pm$ 0.28 inc, Body Fat(%) -1.75 $\pm$ 0.15 dec, Weight(kg): -0.10 $\pm$ 0.04 dec. (dec: decrease, inc: increase)