• Title/Summary/Keyword: Physiological Signals

Search Result 263, Processing Time 0.057 seconds

Immunohistochemical study on the expression of bcl-2 protein during follicular development and atresia in the rat ovary (흰쥐 난포의 성장과 퇴화에 따른 bcl-2 단백질 발현에 관한 면역조직화학적 연구)

  • Koh, Phil-ok;Jeong, Sung-yoon;Cho, Gyeong-jae;Choi, Wan-sung;Kwak, Soo-dong
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.1
    • /
    • pp.27-33
    • /
    • 1999
  • In the mammalian ovary, follicular development and atresia continuously occur during the reproductive cycles. Follicular atresia occurs through granulosa cell apoptosis. Apoptosis is known as the physiological cell death, which is regulated by bcl-2 gene family. In the bcl-2 gene family, bcl-2 and bcl-xLong are known as inhibitors of apoptosis, whereas bax and bcl-xShort are known as inducer of apoptosis. We thought that bcl-2 protein is associated with follicular development and atresia. But it is not known that the distribution of cells containing bcl-2 protein during follicular development and atresia. Therefore, to examine the distribution of cells with bcl-2 protein during ovarian follicular development and atresia, the immunohistochemistry was used in the rat ovary. Bcl-2 immunoreactivity was localized in the interstitial cells, theca externa cells and granulosa cells around of antrum. All positive signals were observed in the cytoplasm of these cells. Positive signals were strongly observed in the interstitial and theca externa cells of growing antral follicles. While, positive signals were weakly observed in these cells from atretic antral follicles. Positive signals were very weakly observed in the granulosa cells of growing and atretic antral follicles. According to these data, we suggested that bcl-2 proteins which were strongly expressed in the interstitial cells and theca externa cells of growing antral follicles inhibit follicular atresia. And we purposed that bcl-2 proteins regulated follicular development and atresia through the action of bcl-2 gene family.

  • PDF

User Activity Estimation by Non-intrusively Measurement (무구속적인 측정에 의한 사용자 활동 상태 추정 기법)

  • Baek, Jong-Hun;Yun, Byoung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.5
    • /
    • pp.101-110
    • /
    • 2009
  • The unconscious and non-intrusive measurements of activity signals or physiological signals represent important enabling technologies for realizing a ubiquitous healthcare environment as well as a related UI. Particularly, non-intrusive measurements should be used in activity monitoring system for long-term monitoring. This paper is based on activity estimation by measuring the activity signals of a user using a handhold device with an accelerometer. The user activity estimation system (UAES) presented in this paper makes non-intrusive measurements of activity signals to minimize inconveniencing a user and to create a more practical implementation in real life. Thus, a variety of positions in which the handhold device can be carried by a user for daily use is considered, such as in the front/hip/shirt pockets, a backpack, on the waist, and in the hand.

Design of Computer Access Devices for Severly Motor-disability Using Bio-potentials (생체전위를 이용한 중증 운동장애자들을 위한 컴퓨터 접근제어장치 설계)

  • Jung, Sung-Jae;Kim, Myung-Dong;Park, Chan-Won;Kim, Il-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.11
    • /
    • pp.502-510
    • /
    • 2006
  • In this paper, we describe implementation of a computer access device for the severly motor-disability. Many people with severe motor disabilities need an augmentative communication technology. Those who are totally paralyzed, or 'locked-in' cannot use conventional augmentative technologies, all of which require some measure of muscle control. The forehead is often the last site to suffer degradation in cases of severe disability and degenerative disease. For example, In ALS(Amyotrophic Lateral Sclerosis) and MD(Muscular dystrophy) the ocular motorneurons and ocular muscles are usually spared permitting at least gross eye movements, but not precise eye pointing. We use brain and body forehead bio-potentials in a novel way to generate multiple signals for computer control inputs. A bio-amplifier within this device separates the forehead signal into three frequency channels. The lowest channel is responsive to bio-potentials resulting from an eye motion, and second channel is the band pass derived between 0.5 and 45Hz, falling within the accepted Electroencephalographic(EEG) range. A digital processing station subdivides this region into eleven components frequency bands using FFT algorithm. The third channel is defined as an Electromyographic(EMG) signal. It responds to contractions of facial muscles and is well suited to discrete on/off switch closures, keyboard commands. These signals are transmitted to a PC that analyzes in a time series and a frequency region and discriminates user's intentions. That software graphically displays user's bio-potential signals in the real time, therefore user can see their own bio-potentials and control their physiological signals little by little after some training sessions. As a result, we confirmed the performance and availability of the developed system with experimental user's bio-potentials.

A Cell Phone-based ECG, Blood Pressure Monitoring System for Personal Healthcare Applications using Wireless Sensor Network Technology

  • Toh, Sing-Hui;Lee, Seung-Chul;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.505-508
    • /
    • 2008
  • Electrocardiogram (ECG) and blood pressure (BP) are main vital signs which are the standards in most medical settings in assessing the most basic body functions. Multi parameters are desired in providing more information for health professionals in order to detect or monitor medical problems of patients more precisely. This study urges us to develop a robust wireless healthcare monitoring system which has multiple physiological signs measurements on real time that applicable to various environments which integrates wireless sensor network technology and code division multiple access (CDMA) network with extended feature of locally standalone diagnosis algorithms that implemented in tell phone. ECG signal and BP parameter of the patients are routinely be monitored, processed and analyzed in details at cell phone locally to produce useful medical information to ease patients for tracking and future reference purposes. Any suspected or unknown patterns of signals will be immediately forwarded to hospital server using cell phone for doctors' evaluation. This feature enables the patients always recognize the importance of self-health checking so that the preventive actions can be taken earlier through this analytic information provided by this monitoring system because "Prevention is better than Cure".

  • PDF

Cryptanalysis of an 'Efficient-Strong Authentiction Protocol (E-SAP) for Healthcare Applications Using Wireless Medical Sensor Networks'

  • Khan, Muhammad Khurram;Kumari, Saru;Singh, Pitam
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.5
    • /
    • pp.967-979
    • /
    • 2013
  • Now a day, Wireless Sensor Networks (WSNs) are being widely used in different areas one of which is healthcare services. A wireless medical sensor network senses patient's vital physiological signs through medical sensor-nodes deployed on patient's body area; and transmits these signals to devices of registered medical professionals. These sensor-nodes have low computational power and limited storage capacity. Moreover, the wireless nature of technology attracts malicious minds. Thus, proper user authentication is a prime concern before granting access to patient's sensitive and private data. Recently, P. Kumar et al. claimed to propose a strong authentication protocol for healthcare using Wireless Medical Sensor Networks (WMSN). However, we find that P. Kumar et al.'s scheme is flawed with a number of security pitfalls. Information stored inside smart card, if extracted, is enough to deceive a valid user. Adversary can not only access patient's physiological data on behalf of a valid user without knowing actual password, can also send fake/irrelevant information about patient by playing role of medical sensor-node. Besides, adversary can guess a user's password and is able to compute the session key shared between user and medical sensor-nodes. Thus, the scheme looses message confidentiality. Additionally, the scheme fails to resist insider attack and lacks user anonymity.

The Role of the Gamma System in Movement and Posture (${\gamma}$계(系)의 자세(姿勢) 및 운동(運動)에 대(對)한 조절기능(調節機能)에 관(關)하여 - Stretch reflex feed back system에 있어서 ${\gamma}$계(系)의 작용(作用)을 중심(中心)으로 -)

  • Kim, Jeh-Hyub
    • The Korean Journal of Physiology
    • /
    • v.4 no.2
    • /
    • pp.19-24
    • /
    • 1970
  • Since the discovery of the muscle spindle by Hassall (1831), an intensive studies of its anatomical and physiological characteristics had been undertaken. Recent morphological studies of Boyd (1962) demonstrated that the muscle spindles have two different intrafusal muscle fibers, nuclear bag and nuclear chain fiber, and these intrafusal fibers are under independent motor innervation by ${\gamma}_1$ and ${\gamma}_2$ motor neurone. Neurophysiological studies of Hunt and Kuffler (1951) showed regulatory effect of ${\gamma}$ motor neurone upon the excitability of the spindle afferents. Harvey and Mathews (1961) observed the dynamic and static characteristics of the two different spindle afferents, the primary and secondary ending. Furthermore, Mathews (1962) postulated the functional existance of two kind of ${\gamma}$ motor neurones, namely, the dynamic and static fusimotor fiber. Recent report of Kim and Partridge(1969) pointed out that the descending vestibular signals had increased the slope of the length-tension relationship in stretch reflex; Kim (1967) demonstrated that the descending vestibular impulses act upon the stretch reflex loop through the ${\gamma}$ motor pathway. These experimental evidences from the morphological and neurophysiological studies on the muscle spindles support the concept that the stretch reflex action of the skeletal muscle operates as a negative feedback control system. The author had discussed the way by which the f system participates in the control of stretch relfex feed back system. that was taken for a prototype of posture and movement.

  • PDF

The Effect of Cold Air Stimulation on Electroencephalogram and Electrocardiogram during the Driver's Drowsiness (운전자 졸음시 냉풍 자극이 뇌파 및 심전도 반응에 미치는 영향)

  • Kim, Minsoo;Kim, Donggyu;Park, Jongil;Kum, Jongsoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.134-141
    • /
    • 2017
  • The purpose of this study was to analyze physiological changes via a cold air reaction experiment to generate basic data that are useful for the development of an automobile active air conditioning system to prevent drowsiness. The $CO_2$ concentration causing drowsiness in vehicle operation was kept below a certain level. Air was blown to the driver's face by using an indoor air cooling apparatus. Sleepiness and the arousal state of the driver in cold wind were measured by physiological signals. It was evident in the EEG that alpha waves decreased and beta waves increased, caused by cold air stimulation. The ${\alpha}/{\beta}$ ratio was reduced by about 52.9% and an alert state confirmed. In the electrocardiogram analysis, the efficiency of cold air stimulation was confirmed by the mean heart rate interval change. The R-R interval had a delay time of about one minute compared to the EEG response. The findings confirmed an arousal effect from sleepiness due to cold air stimulation.

Cardiac Auricular Reflexology Effect Analysis System Based on the Bio Signal (생체 신호 기반의 심장 이혈 효과 분석 시스템)

  • Kim, Bong-Hyun;Cho, Dong-Uk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4C
    • /
    • pp.283-289
    • /
    • 2012
  • Web-based physiological signal monitoring system can provide appropriate healthcare services to transmit bio-signal processing, analysis of bulk in medical centers. Therefore, we constructed a design of system to analyze effect of cardiac associated auricular acupuncture reflexology based on physiological signals. System to analyze effect cardiac associated auricular acupuncture reflexology, which carried out analysis and measurement of bio-signal to apply cardiac-related biometrics input in biometric image and voice signal. In addition, we also confirmed through statistical analysis actual home healthcare system to performance evaluation of system on subjects 20.

A Study on Visual and Auditory Emotion under Color and Music Stimuli (색과 음악 자극에 의한 시청각 감성지표에 관한 연구)

  • 김남균;김지훈;유충기
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.539-546
    • /
    • 1998
  • The purpose of this study is to estimate human emotion quantitatively under colors and music stimuli and to examine the for correlation between color and music sensibility. Physiological signals(electroencephalogram, electrocardiogram, Galvanic skin conductivity and respiration rate) were measured to compare color with music sensibilities. The personality of the subject were investigated using factor analysis and semantic differential method of 20 items(7 interval scaled). The results showed that red, yellow and violets color provoked active and exciting senses mainly as dance, rock and blues music. While blue, cyan and pink colors ware involved in tranquil and resting emotions deeply as classic and ballade music.

  • PDF

Implementation of Wavelet Transform for a Real time Monitoring ECG Telemetry System (웨이브렛 변환을 이용한 실시간 모니터링 ECG 텔레미트리 시스템 구현)

  • 박차훈;서희돈
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.1
    • /
    • pp.27-32
    • /
    • 2002
  • In this study, we fabricated the advanced telemetry system that transmitting media use radio frequency(RF) for the middle range measurement of the physiological signals and receiving media use optical for electromagnetic interference problem. The telemetry system within a size of 65$\times$125$\times$45mm consists of three parts: RF transmitter, optical receiver and physiological signal processing CMOS one chip. Advantages of proposed telemetry system is wireless middle range(50m) FM transmission, reduce electromagnetic interference to a minimum which enables a comfortable bed-side telemetry system. The monitoring system was designed in the structure of dual-processor for the real time processing. The use of the one channel in our study made it possible the real time wavelet transformation of electrocardiogram data of 360Hz, 16 bits for every 1.42 seconds.

  • PDF