• Title/Summary/Keyword: Physiologic parameters

Search Result 75, Processing Time 0.033 seconds

Contributing Factors on Pharmacokinetic Variability in Critically Ill Neonates (신생아중환자의 약동학적 다양성에 영향을 미치는 요인)

  • An, Sook Hee
    • Korean Journal of Clinical Pharmacy
    • /
    • v.27 no.2
    • /
    • pp.63-68
    • /
    • 2017
  • Neonates have large inter-individual variability in pharmacokinetic parameters of many drugs due to developmental differences. The aim of this study was to investigate the factors affecting the pharmacokinetic parameters of drugs, which are commonly used in critically ill neonates. Factors that reflect physiologic maturation such as gestational age, postnatal age, postconceptional age, birth weight, and current body weight were correlated with pharmacokinetic parameters in neonates, especially preterm infants. Comorbidity characteristics affecting pharmacokinetics in critically ill neonates were perinatal asphyxia, hypoxic ischemic encephalopathy, patent ductus arteriosus (PDA), and renal dysfunction. Administration of indomethacin or ibuprofen in neonates with PDA was associated with the reduced clearance of renally excreted drugs such as vancomycin and amikacin. Therapeutic hypothermia and extracoporeal membrane oxygenation were influencing factors on pharmacokinetic parameters in critically ill neonates. Dosing adjustment and careful monitoring according to the factors affecting pharmacokinetic variability is required for safe and effective pharmacotherapy in neonatal intensive care unit.

Analysis of Relations Between Physiologic Parameters and Pulse Transit Time on the Ultrasound Therapy (초음파 재활치료 시 PTT와 생리변수의 상관관계 분석)

  • Kim, Sung-Min;Choi, Sang-Hyuk;Lee, Man-Pyo;Choi, Byeong-Cheol;Jung, Whoi-Seong;Park, Sung-Yoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1514-1520
    • /
    • 2007
  • Currently, the signal of the human body is measured with various methods, and a noninvasive investigation of various methods is useful diagnosis method. PTT(Pulse Transit Time) which is noninvasive investigation make use of to estimate the physiological phenomena. PTT has a latent information of cardiovascular system. So we have the experiments for analysis of the relations between PTT and physiological parameters. We examine to correlate to the physiological parameters, an age and degree of paralysis on the ultrasound therapy. The 40 patients who has a such paralysis join our experiment, and we obtain the PTT data that normal condition and states after ultrasound therapy. We study that PTT after the ultrasound therapy for patients who have a paralysis was related to an age and degree of paralysis.

Objective in Vivo Quantification of Emphysema by Thin-Section CT: Correlation with Physiologic Findings (고해상 전산화단층촬영을 이용한 폐기종의 정량적 분석: 폐기능 검사와의 비교)

  • Lee, Jee-Young;Lee, Kye-Young;Choi, Eun-Kyoung;Kim, Sang-Joon;Choi, Young-Hi
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.992-999
    • /
    • 1998
  • Background: To correlate the emphysema score for quantification of the overall extent of emphysema in both lungs by CT with physiologic fingings and to get more objective and simple method to assess the extent of emphysema. Method: Thin-section CT and pulmonary function test(PFT) were performed in 17 patients with emphysema (all males, mean age, 62 years). Emphysema score was obtained as percentage of emphysematous lung area, dividing the total area of the emphysema(voxels with attenuation value less than -880, -900, -920HU, respectively) by the overall area of both lungs(voxels with attenuation value less than -400HU) with highlighting voxels using "Density mask" program. Emphysema score was calculated from whole lung(ESV) and 5 representative scans(ESR) using "Density mask", Visual emphysema score(ESV) was obtained by visual assessment from 5 representative scans. Correlation of these emphysema scores(ESW, ESR, ESV) and physiologic findings were performed, comparing the ESW with ESR and ESV. Results: ESW had correlation with DLCO(r=0.53-0.64) and $FEV_1/FVC$(r=0.42-0.57) among PFT parameters. ESR had good correlation with ESW and with PFT parameters as well. ESV did not correlate with PFT parameters except DLCO. Conclusion: CT quantification of emphysema using "density mask" correlated well with physiologic findings. To assess the severity of emphysema, both ESW and ESR are more reliable than ESV, and ESR is recommended in routine practice as it is objective, simple and reliable.

  • PDF

Analysis of Voice Parameters on Different Phonatory Tasks using Multi-Channel Phonatory Function Analyzer in Healthy Adults (다채널 음성분석장치를 이용한 정상 성인에서의 발성 방식에 따른 음성변수 분석)

  • 성명훈;이상준;김광현;노종렬;권택균;이강진;박광석;최종민
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.13 no.2
    • /
    • pp.132-138
    • /
    • 2002
  • Background and Objectives : The complex physiologic structure of the larynx can vibrate in three or more different ways that yield acuostically and perceptually distinct vocal quality. The purpose of this study is to examine the normal range of voice parameters in Multi-Channel Phonatory Function Analyzer and investigate the difference of voice parameters according to the phonatory patterns. Materials and Methods : Forty normal adult speakers (20 men and 20 women) with age ranging from third to forth decades pronounce low, comfortable, and high tone /a/ ; comfortable tone /${\ae}$/, /i/, /o/, and /u/ : fry, falsetto. Voice was analyzed by Newly developed multi-channel phonatory function analyzer. Results : The normal range of voice parameters in this system was similar to the existing data. Fry shows high jitter and falsetto low SQ. Fry and falsetto show low OQ in men but no difference in women. Jitter, OQ and SQ were different between men and women in modal register, whereas there was no gender difference in fry and falsetto. In frequency magnitude spectrum and EGG, modal register, fry and falsetto have distinguishing pattern. Conclusions : Modal register, fry and falsetto are distinguishable in voice parameters and show different vibratory patterns.

  • PDF

A Study on the Development of a Single-Chamber Cardiac Pacemaker Tester (Single-Chamber 페이스메이커 테스터의 개발에 관한 연구)

  • Kang, B.Y.;Shin, J.W.;Yoon, Y.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.119-120
    • /
    • 1998
  • In this study, the design of the single-chamber pacemaker tester is presented. It is important to test the functions of the pacemaker before it is implanted into the patient. A pacemaker tester, that is presented in this study, is able to examine pacemaker parameters such as sensing threshold and refractory period. We need to make artificial intracardiac electrogram in order to test the pacemaker parameters. We know from the previous practical examples that a triangle pulse is similar to the physiologic intracardiac electrogram. The tester generates the simplified electrograms and PC software examines the output pulses of the pacemaker which is VVIR mode in closed-loop simulation.

  • PDF

Physiologic Cervical Alignment Change between Cervical Spine X-ray and Computed Tomography

  • Lee, Ho Jin;Kim, Il Sup;Hong, Jae Taek
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.784-790
    • /
    • 2021
  • Objective : The purpose of this study was to investigate the correlations among various radiological parameters used to determine cervical alignment from cervical spine radiographs (X-CS) and cervical spine computed tomography (CT-CS), both within and between modalities. Methods : This study included 168 patients (≤60 years old) without a definite whole spine deformity who underwent CT-CS and X-CS. We measured occipital slope (O-s), C1 slope, C2 slope, C7 slope, sella turcica - C7 sagittal vertical axis (StC7-SVA), spino-cranial angle, T1 slope, and C27-SVA. We calculated the O-C2 angle, O-C7 angle, and C2-7 angle from the measured parameters and conducted correlation analyses among multiple parameters. Results : The intrinsic correlation features among multiple cervical parameters were very similar for both X-CS and CT-CS. The two SVA parameters (C27-SVA and StC7-SVA) were mainly influenced by the upper cervical slope parameters (r=|0.13-0.74|) rather than the lower slope cervical parameters (r=|0.08-0.13|). The correlation between X-CS and CT-CS for each radiological parameter was statistically significant (r=0.26-0.44) except for O-s (r=0.10) and StC7-SVA (r=0.11). Conclusion : The correlation patterns within X-CS and CT-CS were very similar in this study. The correlation between X-ray and CT was statistically significant for most radiological parameters, and the correlation score increased when the horizontal gaze was consistently maintained. The lower cervical parameters were not statistically associated with translation-related parameters (C2-7 SVA and StC7-SVA). Therefore, the upper cervical segment may be a better predictor for determining head and neck translation.

The Correlation between HRCT Emphysema Score and Exercise Pulmonary Testing Parameters (HRCT Emphysema Scoring과 운동부하 폐기능검사 지표들 간의 상관관계)

  • Choi, Eun-Kyoung;Choi, Young-Hee;Kim, Doh-Hyung;Kim, Yong-Ho;Yoon, Se-Young;Park, Jae-Seuk;Kim, Keun-Youl;Lee, Kye-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.4
    • /
    • pp.415-425
    • /
    • 2001
  • Background : The correlation between the high resolution computed tomography(HRCT) emphysema score and the physiologic parameters including resting and exercise pulmonary function test was investigated in 14 patients($60.6{\pm}10.3$ years) with pulmonary emphysema. Methods : The patients underwent a HRCT, a resting pulmonary function test, and incremental exercise testing(cycle ergometer, 10 W/min). Computed tomography scans were obtained on a GE highlight at 10 mm intervals using 10 mm collimation, from the apex to the base after a full inspiration. The emphysema scores were determined by a CT program 'Density mask' outlining the areas with attenuation values less than -900 HU, indicating the emphysema areas, and providing an overall percentage of lung involvement by emphysema. Results : Among the resting PFT parameters, only the diffusing capacity(r=-0.75) and $PaO_2$ (r=-0.66) correlated with the emphysema score(p<0.05). Among the exercise test parameters, the emphysema score correlated significantly with the maximum power(r=-0.74), maximum oxygen consumption(r=-0.68), anaerobic threshold(V-slope method: r=-0.69), maximal $O_2$-pulse(r=-0.73), and the physiologic dead space ratio at the maximum workload(r=-0.80)(p<0.01). Conclusion: We could find that exercise testing parameters showed a much better correlation with the HRCT emphysema score, which is known to have a good correlation with the pathologic severity than the resting PIT parameters. Therefore it is suggested that exercise testing is superior to resting PIT for estimating in the estimation of the physiologic disturbance in emphysema patients.

  • PDF

Physiologic state and behavioral response to sponge bathing in premature infants (스폰지 목욕에 대한 미숙아의 생리적상태 및 행동반응)

  • Lee Hae Kyung;Hong Kyung Ja;Nam Eun Sook;Lee Young Hee;Jung Eun Ja
    • Child Health Nursing Research
    • /
    • v.6 no.1
    • /
    • pp.32-50
    • /
    • 2000
  • A descriptive exploratory design was used in this study to evaluate the effects of sponge bathing on physiological(heart rate, heart period, vagal tone, oxygen saturation, respiration) and behavioral responses in newly born 40 preterm infants from intensive care unit of S University Hospital in Seoul. Data has been collected from October, 1997 to March, 1999. The infants were between 27-33 weeks gestational age at birth, and were free of congenital defects. The subjects entered the protocol when they were medically stable (determined by initiation of feeding and discontinuation of all respiratory support) but still receiving neonatal intensive care. The infants' physiologic parameters were recorded a 10 - minute before, during, and after bathing. Continuous heart rate data were recorded on a notebook computer from the infant's EKG monitor. The data were digitized off-line on software(developed by Lee and Chang in Wavelet program) which detected the peak of the R wave for each heart beat and quantified sequential R-R intervals in msec(i.e. heart periods). Heart period data were edited to remove movement artifact. Heart period data were quantified as : 1) mean heart period; 2) vagal tone. Vagal tone was quantitfied with a noninvasive measure developed by Porges(1985) in Mxedit software. To determine behavioral status, tools were developed by Scafidi et al(1990) were used. Collected data were analyzed with the SPSS program using paried t-test, ANOVA, and Pearson correlation. The result were as follow. 1. The results of the ANOVAs indicated that vagal tone were signifcantly lower during bathing than baseline and post-bathing. There were significant differences in heart period and heart rate levels across the bathing. But the mean oxygen saturations and respirations were no differences. Also, there were no significant differences on behavioral sign, motor activity, behavioral distress, weight changes, morbidity, and hospitalization period. 2. To evaluate the relation between vagal tone and subsequent parameters, the two groups (the high group had 19 subjects and low group had 21subjects) were divided by the mean baseline vagal tone. Vagal tone measured prior to bathing were significantly associated with respiration before bathing, vagal tone during bathing, and the magnitude of change in both vagal tone. But, other subsequent reactivities were no differences in two groups. 3. Correlations were also calculated between vagal tone and the subsequent physiological reactivities from baseline through after- bathing. Correlations were significant between baseline vagal tone and baseline heart rate, between baseline vagal tone and baseline heart period, between baseline vagal tone and oxygen saturation after bathing. In summary, the bathing in this study showed a stressful stimulus on premature infants through there was significance in the physiological parameters. In addition, our study represents the documentation that vagal tone reactivity in response to clearly defined external stimulation provides an index of infant's status.

  • PDF

Study of Ryodoraku Parameters for Diagnosing Gastric Dysmotility in Functional Dyspepsia (기능성 소화불량증에서 위운동성 장애 진단을 위한 양도락 지표 연구)

  • Kim, So-Yeon;Yoon, Sang-Hyup;Kim, Yoon-Bum;Jung, Sung-Ki
    • The Journal of Internal Korean Medicine
    • /
    • v.29 no.2
    • /
    • pp.401-412
    • /
    • 2008
  • Objectives : The aim of this study was to investigate the characteristics of Ryodoraku and association of Ryodoraku with gastric dysmotility in functional dyspepsia(FD). Methods : Subjects were 154 patients with FD and 18 patients with asthma. We calculated the average Ryodoraku score(RS, ${\mu}A$) and each variation from physiologic range of 12 Ryodoraku points, and investigated the incidence when left and right points were simultaneously below(bilateral deficiency) or above(bilateral excess) physiologic range. Postprandial regularity of normal slow waves, power ratio, and postprandial % of bowel sound were obtained by electrogastrography and enterotachography, and were used as gastric dysmotility index. Results : 1. Bilateral excess of H4, H5, F1, and F4 and bilateral deficiency of H4, H5, and H6 were characteristic in FD compared with asthma patients. 2. Incidence of gastric dysmotility in bilateral deficiency of H4, H5, and H6 was 100%, and was higher than in total FD patients(88.3%). 3. There was a positive correlation between the variation of H6 and % postprandial bowel sound. 4. Deficient tendency of H4, H5, and H6 was more evident when RS was above $40{\mu}A$ in FD. Conclusions : These findings suggest that gastric dysmotility in FD can be diagnosed when a pattern of H4, H5, H6 bilateral deficiency and F1, F4 bilateral excess is shown at the same time. We think this phenomenon is related to low activity of the vagus nerve rather than meridian pathway with result based on positive correlation between variation of H6 and postprandial % of bowel sound.

  • PDF

Study of Ryodoraku Parameters for Diagnosing Idiopathic Facial Paralysis Patients (특발성 안면신경마비 환자의 진단도구로서의 양도락 지표 연구)

  • Yoo, Seung-Yeon;Kwon, Hyo-Jung;Kim, Young-Jin;Lee, Seung-Hoon;Chung, Jie-Youn;Kwak, Hyun-Young;Kim, Ji-Hye;Seon, Jong-In;Lim, Sung-Keun;Park, Young-Bae
    • Journal of Acupuncture Research
    • /
    • v.27 no.6
    • /
    • pp.95-100
    • /
    • 2010
  • Objectives : The aim of this study was to investigate the characteristics of Ryodoraku and association of Ryodoraku in Idiopathic Facial Paralysis Patients Methods : Subjects were 53 patients with Facial palsy patients and 28 normal people. We calculated the average Ryodoraku score(RS, ${\mu}A$) and each variation from physiologic range of 12 Ryodoraku points, and investigated the incidence when left and right points were simultaneously below(bilateral deficiency) or above(bilateral excess) physiologic range. Results : The electric current value of several meridian of normal group was more higher in idiopathic facial palsy group than in normal group. The measurement value of Ryodoraku followed sex was not significant statistically. Conclusions : These findings suggest that the measurement value of several Meridians of Ryodoraku is more higher in idiopathic facial palsy group than in normal group, because Ryodoraku has low correlation with Parasympathetic nerve.