• Title/Summary/Keyword: Physiologic monitoring

Search Result 24, Processing Time 0.018 seconds

Implementation of a Remote Patient Monitoring System using Mobile Phones (모바일 폰을 이용한 원격 환자 관리 시스템의 구현)

  • Park, Hung-Bog;Seo, Jung-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.6
    • /
    • pp.1167-1174
    • /
    • 2009
  • In the monitoring of a patient in a sickroom, not only the physiologic and environmental data of the patient, which is automatically measured, but also the clinical data(clinical chart)of the patient, which is drew up by a doctor or nurse, are recognized as important data. However, since in the current environment of a sickroom, clinical data is collected being divided from the data that is automatically measured, the two data are used without an effective integration. This is because the integration of the two data is difficult due to their different collection times, which leads the reconstruction of clinical data to be remarkably uncertain. In order to solve these problems, a method to synchronize the continuous environmental data of a sickroom and clinical data is appearing as an important measure. In addition, the increase of use of small machines and the development of solutions based on wireless communications provide a communication platform to the developers of health care. Thus, this paper realizes a remote system for taking care of patients based on a web that uses mobile phones. That is, clinical data made by a nurse or doctor and the environmental data of a sick room comes to be collected by a collection module through a wireless sensor network. An observer can see clinical data and the environmental data of a sickroom through his/her mobile phone, integrating and storing his/her data into the database. Families of a patient can see clinical data made by hospital and the environment of the sick room of the patent through their computers or mobile phones outside the hospital. Through the system,hospital can provide better medical services to patients and their families.

Effect of Intracarotid Cold Saline Infusion during Cerebral Ischemia on Brain Edema in the Rabbit (뇌허혈기동안 경동맥으로 냉각 생리식염수 주입이 허혈후 뇌부종에 미치는 영향)

  • Kim, Sae-Yeon;Choi, Kyu-Taek
    • Journal of Yeungnam Medical Science
    • /
    • v.12 no.2
    • /
    • pp.260-268
    • /
    • 1995
  • Ischemia results when the decrease in tissue perfusion exceeds the tissues ability to increase an oxygen extraction from the blood. Brain edema has been defined as an abnormal accumulation of fluid within brain parenchyma associated with a volumetric enlargement of the brain tissue. In most instances, the labelling of edema as vasogenic or cytotoxic is only relative. For cerebral protection, there were many possible techniques which could increase or maintain cerebral perfusion and reduce cerebral metabolic demand for oxygen. This study was carried out the effect of mild brain hypothermia which was induced by infusion with cold saline into the carotid artery, during brief episodes of transient global ischemia on postischemic brain edema in rabbit. Eight rabbits were anesthetized with halothane and mechanically ventilated with oxygen. For isolated cerebral perfusion, polyethylene catheter was inserted left carotid artery for infusion of cold saline, external carotid artery was ligated, vertebral arteries were cautherized, right carotid artery was snared for ischemia and femoral artery and vein were also canulated for monitoring and drug treatment. At 3 hours After transient global ischemia, specific gravity of cerebral cortex and hippocampus was compared with no-perfusion group , perfusion with cold saline group and normal group. There was no significant differences in physiologic variables among the groups before transient global ischemia. But during transient global ischemia, brain temperature of perfusion group was decreased when compared to no perfusion group. Specific gravity of cerebral cortex and hippocampus of no-perfusion group and perfusion group was statistically significant when compared to normal group (p<0.01). The results of this study suggested that mild brain hypothermia with intracarotid cold saline infusion during brief episodes of transient global ischemia had decreased postischemic brain edema in rabbit.

  • PDF

Evaluation of Acid Steatocrit in Korean Infants (한국인 영아에서의 Acid Steatocrit 표준치에 관한 연구)

  • Kim, Kyo-Sun;Park, Ji-He;Sim, Jae-Geon
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.4 no.1
    • /
    • pp.77-82
    • /
    • 2001
  • Purpose: The fecal acid steatocrit is an improved steatocrit method for the evaluation of fecal fat. The present study was set up in order to define the normal range of acid steatocrit values during the first 3 months of life. Methods: Fecal acid steatocrit values were determined in 78 healthy full term and in 21 healthy prematurely born infants between May 1998 and April 2000. The acid steatocrit method was performed in these babies during the first 3 months of life. Results: Steatorrhea occurs during the first month and then decreases, as shown by the fall in the acid steatocrit curve from 1st to 3rd month in our subject. Very high acid steatocrit results (above 90%) were found in all full term and premature infants during the first month of age. Acid steatocrit results of human milk-fed infants were significantly lower than those of formula-fed infants (p=0.0018). Conclusion: We conclude that high acid steatocrit results during the first 1 month of age can be due to physiologic steatorrhea. The acid steatocrit micromethod can be used for the evaluation of milk fat absorption in infants and monitoring steatorrhea instead of other more cumbersome methods.

  • PDF

Comparison of Imposed Work of Breathing Between Pressure-Triggered and Flow-Triggered Ventilation During Mechanical Ventilation (기계환기시 압력유발법과 유량유발법 차이에 의한 부가적 호흡일의 비교)

  • Choi, Jeong-Eun;Lim, Chae-Man;Koh, Youn-Suck;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.3
    • /
    • pp.592-600
    • /
    • 1997
  • Background : The level of imposed work of breathing (WOB) is important for patient-ventilator synchrony and during weaning from mechanical ventilation. Triggering methods and the sensitivity of demand system are important determining factors of the imposed WOB. Flow triggering method is available on several modern ventilator and is believed to impose less work to a patient-triggered breath than pressure triggering method. We intended to compare the level of imposed WOB on two different methods of triggering and also at different levels of sensitivities on each triggering method (0.7 L/min vs 2.0 L/min on flow triggering ; $-1\;cmH_2O$ vs $-2cm\;H_2O$ on pressure triggering). Methods : The subjects were 12 patients ($64.8{\pm}4.2\;yrs$) on mechanical ventilation and were stable in respiratory pattern on CPAP $3\;cmH_2O$. Four different triggering sensitivities were applied at random order. For determination of imposed WOB, tracheal end pressure was measured through the monitoring lumen of Hi-Lo Jet tracheal tube (Mallincrodt, New York, USA) using pneumotachograph/pressure transducer (CP-100 pulmonary monitor, Bicore, Irvine, CA, USA). Other data of respiratory mechanics were also obtained by CP-100 pulmonary monitor. Results : The imposed WOB was decreased by 37.5% during 0.7 L/min on flow triggering compared to $-2\;cmH_2O$ on pressure triggering and also decreased by 14% during $-1\;cmH_2O$ compared to $-2\;cmH_2O$ on pressure triggering (p < 0.05 in each). The PTP(Pressure Time Product) was also decreased significantly during 0.7 L/min on flow triggering and $-1\;cmH_2O$ on pressure triggering compared to $-2\;cmH_2O$ on pressure triggering (p < 0.05 in each). The proportions of imposed WOB in total WOB were ranged from 37% to 85% and no significant changes among different methods and sensitivities. The physiologic WOB showed no significant changes among different triggering methods and sensitivities. Conclusion : To reduce the imposed WOB, flow triggering with sensitivity of 0.7 L/min would be better method than pressure triggering with sensitivity of $-2\;cm\;H_2O$.

  • PDF