• Title/Summary/Keyword: Physical protection

Search Result 725, Processing Time 0.039 seconds

Polymerized Organic Thin Films and Comparison on their Physical and Electrochemical Properties

  • Cho, S.H.;You, Y.J.;Kim, J.G.;Boo, J.H.
    • Journal of Surface Science and Engineering
    • /
    • v.36 no.1
    • /
    • pp.9-13
    • /
    • 2003
  • Plasma polymerized organic thin films were deposited on Si(100), glass and metal substrates at $25∼100 ^{\circ}C$ using thiophene and toluene precursors by PECVD method. In order to compare physical and electrochemical properties of the as-grown thin films, the effects of the RF plasma power in the range of 30∼100 W and deposition temperature on both corrosion protection efficiency and physical properties were studied. We found that the corrosion protection efficiency ($P_{k}$), which is one of the important factors for corrosion protection in the interlayer dielectrics of microelectronic devices application, was increased with increasing RF power. The highest $P_{k}$ value of plasma polymerized toluene film (85.27% at 70 W) was higher than that of the plasma polymerized thiophene film (65.17% at 100 W), indicating inhibition of oxygen reduction. The densely packed and tightly interconnected toluene film could act as an efficient barrier layer to the diffusion of molecular oxygen. The result of contact angle measurement showed that the plasma polymerized toluene films have more hydrophobic surface than those of the plasma polymerized thiophene films.

Comparative Study on the Protective Functions of Clothes (의복의 보호론에 관한 이론적 고찰)

  • Lim Sook Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.9 no.3
    • /
    • pp.71-78
    • /
    • 1985
  • This research is designed to systemize the protection theory as well as to supplement the missing theory by organizing various studies on the protective functions of celothes by domestic and foreign scholers of clothing. Human environments is classified two standpoints : (1) Physical environments, and (2) man built psychological environments including socio-physical environments, socio-biological environments, behavioral environments, socio-psychological environments and institution environments. Clothes acting as a physical protection might be of (1) extreme air temperature: Parka; (2) high relative humidity: raincoat; (3) air movement: windbreaker; (4) radiation: space suit; (5) atmospheric pressure: deep sea diver suit; (6) mechanical agent: bullet proof vest; (7) physical agent: (8) chemical agent: (9) biological agent: surgeon's gown, cap, and mask. Also dresses act to support the body comfort, health and the well-being; corset for bad back patient, wrist band for people with weak wrist, bottom half of pressure suit for people with low blood pressure. Clothes acting as a psychological protection might be of (1) influence of magic and of spirits: (2) moral danger; (3) the general unfriendliness of the world as a whole; a reassurance against the lack of love. Clothes should provide the maximum of satisfaction in accordance with the full recognition of reality. The reality should aim at the formulation of general laws concerning the most pleasing forms, colors, and styles to suit. The complex physiological anatomical and psychological aspects of individual personalities.

  • PDF

Vital Area Identification Rule Development and Its Application for the Physical Protection of Nuclear Power Plants (원자력발전소의 물리적방호를 위한 핵심구역파악 규칙 개발 및 적용)

  • Jung, Woo Sik;Hwang, Mee-Jeong;Kang, Minho
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.3
    • /
    • pp.160-171
    • /
    • 2017
  • US national research laboratories developed the first Vital Area Identification (VAI) method for the physical protection of nuclear power plants that is based on Event Tree Analysis (ETA) and Fault Tree Analysis (FTA) techniques in 1970s. Then, Korea Atomic Energy Research Institute proposed advanced VAI method that takes advantage of fire and flooding Probabilistic Safety Assessment (PSA) results. In this study, in order to minimize the burden and difficulty of VAI, (1) a set of streamlined VAI rules were developed, and (2) this set of rules was applied to PSA fault tree and event tree at the initial stage of VAI process. This new rule-based VAI method is explained, and its efficiency and correctness are demonstrated throughout this paper. This new rule-based VAI method drastically reduces problem size by (1) performing PSA event tree simplification by applying VAI rules to the PSA event tree, (2) calculating preliminary prevention sets with event tree headings, (3) converting the shortest preliminary prevention set into a sabotage fault tree, and (4) performing usual VAI procedure. Since this new rule-based VAI method drastically reduces VAI problem size, it provides very quick and economical VAI procedure. In spite of an extremely reduced sabotage fault tree, this method generates identical vital areas to those by traditional VAI method. It is strongly recommended that this new rule-based VAI method be applied to the physical protection of nuclear power plants and other complex safety-critical systems such as chemical and military systems.

Analysis of Physical Component Considered for The Development of Smart Card Protection Profile (스마트 카드 보호프로파일 개발을 위하여 고려하여야 하는 물리적 위협 요소 분석)

  • Kim, Tai-Hoon;Kim, Min-Chul;Sung, Yune-Gie;Cho, Kyu-Min;No, Byung-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2747-2749
    • /
    • 2003
  • Security is concerned with the protection of assets from threats, where threats are categorised as the potential for abuse of protected assets. All categories of threats should be considered, but in the domain of security greater attention is given to those threats that are related to malicious or other human activities ISO/IEC 15408 requires the TOE(Target of Evaluation) Security Environment section of a Protection Profile(PP) or Security Target(ST) to contain a list of threats about the TOE security environment or the intended usage of the TOE. This paper presents a specific physical threats should be considered in the smart card PP which developers of smart card PP must consider.

  • PDF

Environmental Radiation Protection in Medical Institutions

  • Han, Eun-Ok;Dong, Kyung-Rae
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.91-95
    • /
    • 2010
  • The study aimed to measure the levels of radiation protection for radiologists in medical institutions in three environmental categories (physical, administrative and social) and to establish a data base which can be used to increase awareness of environmental radiation protection in medical institutions within Korea. The study surveyed 10% of radiologists working in radiology departments in medical institutions which are supervised by the National Dose Registry overseen by the Korean Food and Drug Administration(KFDA). This study found that the level of environmental radiation protection was higher in the capital area and in larger hospitals. On the other hand, the study shows environmental radiation protection was lower in the Youngnam area and in clinics. Results from the questionnaires indicate the level of environmental radiation protection was higher when radiologists were given an individual dosimeter but lowest when the radiation protection apron quality test was conducted. Environmental radiation protection is an important factor for radiologists to conduct activities in a safe and protected environment. However, this study shows there are differences in the level of environmental radiation protection in medical institutions and location within Korea. In particular, the level of environmental radiation protection was lower in clinics, appropriate intervention strategies befitting these conditions are needed based on medical institution classification and location in order to improve the level of environmental protection.

Development of Polymer Mortar Protection Block for Erosion Control Works (폴리머 모르터를 이용한 사면보호재의 개발)

  • Ryu, Neung-Hwan;Yeon, Kyu-Seok;Kim, Ki-Sung;Lee, Youn-Su
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.5
    • /
    • pp.52-58
    • /
    • 1998
  • The objective of this study was to develop a polymer mortar protection block with high strength and durability using unsaturated polyester resin to complement defects of conventional cement mortar protection block. Physical and mechanical properties of the polymer mortar protection block were also investigated. Low absorptivity, high impact strength, and great bending strength of the polymer mortar protection block was compared with those of the conventional cement protection block. In conclusion, the polymer mortar protection block is excellent and useful as industrial products for erosion control works.

  • PDF

A Study of Euro NCAP Pedestrian Protection Protocol in Upper Leg Area (유럽 신차 안전도 평가방법을 적용한 보행자 대퇴부 상해 영향 분석)

  • Hyungjoon Oh;Hanchun Cho;Junyi Kim;Seungki Kim
    • Journal of Auto-vehicle Safety Association
    • /
    • v.6 no.1
    • /
    • pp.16-21
    • /
    • 2014
  • Recently Korea and many countries are legislated for pedestrian protection as following the GTR(Global Technical Regulation). Most NCAP organization have been applying pedestrian protection results in their own rating system in individual or overall rating. Euro NCAP agency has been introduced it first. From the beginning, Euro NCAP had assessed occupant and pedestrian protection. It has become to strengthen a pedestrian protection protocol every time published. Korea NCAP also has been rating pedestrian protection with overall rating system. This paper proposed to study new pedestrian protection protocol especially upper leg in order to find injury response based on physical test. On Euro NCAP, the upper leg injury are assessed two kind of value which are bending moment and force.

Relationship between Functional Fitness and Break Response in Elderly Drivers: Comparison with Young Driver

  • Kim, Ga Eun;Choi, Ye Eun;Yang, Su Seong;Kim, Sun A;Bae, Young Sook
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.5
    • /
    • pp.187-192
    • /
    • 2018
  • Purpose: This study compared the functional fitness and brake response of elderly and young drivers to confirm the correlation between the functional fitness and brake response. Methods: This study was a cross sectional observational design. Older drivers (>65age, n=21) and young adult drivers (20-40aged, n=20) were enrolled as subjects. The functional fitness of the subjects was measured using a senior fitness test consisting of a back scratch (BS), chair sit and reach (CSR), arm curl (AC), chair stand up (CSU), foot up and go (8-FUG), and 2-minute step (2-MS). The brake response used the virtual driving simulator to measure the brake reaction time (BRT) and braking distance (BD) according to the pedestrian protection and traffic signal compliance. Results: The older drivers had a lower BS (p<0.000), CSU (p=0.040), and 8-FUG (p=0.011) than the young adult drivers. BS and 8-FUG showed a significant positive correlation with the BRT and BD of pedestrian protection and traffic signal compliance. CSU showed a significant negative correlation with the BRT of pedestrian protection and traffic signal compliance. Conclusion: These findings suggest that the flexibility of the upper extremity, lower extremity strength, and agility are strongly correlated with the driving performance of elderly drivers.

Alginic acid-silica hydrogel coatings for the protection of ssmotic distillation membranes against wet-out by surface-active agents

  • Xu, J.B.;Spittler, D.A.;Bartley, J.P.;Johnson, R.A.
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.354-354
    • /
    • 2006
  • Alginic acid-silica hydrogel films was prepared for testing as protective coating materials for PTFE OD membranes. Unprotected hydrophobic membranes are subject to wet-out when contacted by surface-active agents. Films were characterised using SEM, XRD, DSC, mechanical strength measurements, and water-swelling measurements. In OD trials using coated membranes, no wet-out occurred over the 15 h duration of three consecutive 5 h OD trials using orange oil-water mixtures. In the case of detergent solutions, the coating afforded protection to the membrane for 4-5 h. In a separate trial, no wet-out occurred when the coated side of the membrane was placed in contact with 1.2 wt % orange oil for 72 hours.

  • PDF