Gait Analysis of Parkinson's Disease Patients (파킨슨 질환 환자의 보행분석)

  • You, Jae-Eung;Choi, Byung-Ok;Jung, Seok
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.4
    • /
    • pp.569-574
    • /
    • 2005
  • The purposes of this study were to present the basic reference data of age and specipic gait parameters for Parkinson's disease patients. The basic gait parameters were extracted from 20 patients of parkinson's disease and 20 healthy control subjects using VICON 512 Motion Analyzer. The temporal gait parameters and kinematic parameters is data of Parkinson' s Disease Patients. The results were as follows: (1) In patients' group, cadence, walking velocity were less than control group (p<.05). (2) In patients' group, maximum flexion of hip, maximum adduction of hip and maximum flexion of the knee were less than control group (p<.05). (3) In patients' group, maximum varus of the knee were more than control group (p<.05).

  • PDF

Relative merits of different types of multi-wavelength observations to constrain galaxy physical parameter

  • Pacifici, Camilla
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.35.2-35.2
    • /
    • 2013
  • I will present a new approach to constrain galaxy physical parameters from the combined interpretation of stellar and nebular emission in wide ranges of observations. This approach relies on a comprehensive library of synthetic spectra, assembled using state-of-the-art models of star formation and chemical enrichment histories, stellar population synthesis, nebular emission and attenuation by dust. We focus on the constraints set by 5-band photometry and low- and medium-resolution spectroscopy at optical rest wavelengths on a few physical parameters characterizing the stars and interstellar medium. Since these parameters cannot be known a priori for any galaxy sample, we assess the accuracy to which they can be retrieved by simulating 'pseudo-observations' using models with known parameters. We find that the combined analysis of stellar and nebular emission in low-resolution (50A FWHM) galaxy spectra provides valuable constraints on all physical parameters. The approach can be extended to the analysis of any type of observation and during this talk i will present some applications to observed galaxies up to redshift 1.5.

  • PDF

Kinematic Characteristics during of Gait in Parkinson's Disease Patients (파킨슨 질환 환자의 보행시 운동형상학 특성)

  • You, Jae-Eung;An, Chang-Sik
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.2
    • /
    • pp.453-458
    • /
    • 2001
  • The aim of this study is to present the basic reference data of age and specific gait parameters for Parkinson's Disease Patients. The basic gait parameters were extracted from 5 patients, 5 men and 65 years of age using VICON 512 Motion Analyzer. The temporal gait parameters and kinematic parameters is data of Parkinson's Disease Patients. The results were as follows; 1. The cadence, velocity, stride length decreased and single limb support period, double limb support period increased than normal adult in the temporal parameters. 2. The mean angles of joint pelvic tilt and hip, knee, ankle joint decreased than normal adult at kinematic characteristics on sagittal plane. 3. The mean angles of joint pelvic tilt and hip, knee joint has no difference than normal adult at kinematic characteristics on coronal plane. 4. The mean angles of joint pelvic tilt, hip joint no difference and internal, external rotation in ankle joint significantly decreased than normal adult at kinematic characteristics on transverse plane.

  • PDF

An SVM-based physical fatigue diagnostic model using speech features (음성 특징 파라미터를 이용한 SVM 기반 육체피로도 진단모델)

  • Kim, Tae Hun;Kwon, Chul Hong
    • Phonetics and Speech Sciences
    • /
    • v.8 no.2
    • /
    • pp.17-22
    • /
    • 2016
  • This paper devises a model to diagnose physical fatigue using speech features. This paper presents a machine learning method through an SVM algorithm using the various feature parameters. The parameters used include the significant speech parameters, questionnaire responses, and bio-signal parameters obtained before and after the experiment imposing the fatigue. The results showed that performance rates of 95%, 100%, and 90%, respectively, were observed from the proposed model using three types of the parameters relevant to the fatigue. These results suggest that the method proposed in this study can be used as the physical fatigue diagnostic model, and that fatigue can be easily diagnosed by speech technology.

Effects of hallux valgus angle on one-legged stance and gait parameters in young adults: a preliminary study

  • Ji, Minkyung;Park, Hyodong;Lee, Heeyeon;Yoo, Minjoo;Ko, Eunsan;Woo, Youngkeun
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.1
    • /
    • pp.10-17
    • /
    • 2020
  • Objective: Hallux valgus (HV) is a common musculoskeletal deformity that is accompanied with pain and continues to decrease one's quality of life and ability to perform daily life activities by affecting gait and static stability. Therefore, this study aimed to investigate the effect of the angle of HV (HVA) and to compare the one-legged stance and gait parameters in young adults with less HV and severe HV. Design: Cross-sectional study. Methods: Forty young adults were divided into two groups, where HVA ≥15° (n=20) was defined as HV, and HVA <15° (n=20) was defined as normal. For balance ability, the center of pressure (COP) path, velocity, length of axis of the COP path, deviation of the x-axis and y-axis, and percentage of foot pressure were measured, and gait, the foot rotation angle, step length, percentage of each phase of the gait cycle, time change from the heel to forefoot, and maximum pressure of the forefoot and midfoot were measured. Results: Significant differences were found in sway length and time change from heel to forefoot during walking between the normal and HV groups (p<0.05). Most parameters were not associated with the HVA, but parameters such as length of axis and time to change from heel to forefoot were significantly associated with the HVA (p<0.05). Conclusions: These results suggest that most one-legged stance and gait parameters were not significantly affected by the HVA in young adults; therefore, future studies are needed in order to address other dynamic parameters and other methods of gait analysis for detecting clinically meaningful conditions.

Determination of Physical Camera Parameters from DLT Parameters (직접선형변환 매개변수로부터 물리적 사진기 매개변수의 산정)

  • Jeong, Soo;Lee, Chang-No;Oh, Jae-Hong
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.13 no.2 s.32
    • /
    • pp.39-43
    • /
    • 2005
  • In this study, we analyzed the accuracy of the conversion from DLT parameters to physical camera parameters and optimized the use of DLT model for non-metric cameras in photogrammetric tasks. Using the simulated data, we computed two sets of physical camera parameters from DLT parameters and Bundle adjustment for various cases. Comparing two results based on the RMSE values of check points, we optimized the arrangement of GCPs for DLT.

  • PDF

The Immediate Effects of Elastic Taping on Center of Pressure and Foot Pressure Distribution

  • Jung-Hee Kim;Jong-Ho Kook;Sang-Mi Lee;Eun-Bin Ko;Song-Yi Han;Yeon-Jeong Kim;Byeong-Jun Min
    • PNF and Movement
    • /
    • v.22 no.1
    • /
    • pp.23-30
    • /
    • 2024
  • Purpose: Ankle instability is a common issue in both daily activities and sports, often leading to recurrent injuries. Elastic taping is a non-pharmacological intervention used to improve ankle stability. This study aimed to investigate the immediate effects of elastic taping on ankle stability, center of pressure (COP) movement, and foot pressure distribution. Methods: A single-group pre-posttest design was employed, with 30 participants included in the study. Plantar pressure and COP parameters were measured before and after the application of elastic taping. Taping was administered in three distinct patterns to enhance ankle stability. Results: Immediate effects of elastic taping were evident in COP parameters. Following taping application, there was a significant decrease in COP total displacement, COP area, and COP velocity. However, no significant changes were observed in plantar pressure parameters. Conclusion: The application of elastic taping in this study demonstrated immediate effects on ankle stability and COP parameters, indicating its potential as a viable intervention for improving balance. Further research with larger sample sizes and long-term follow-up is needed to elucidate the sustained effects of elastic taping on ankle stability.

The effect of geometrical parameters on the radon emanation coefficient and different radon parameters

  • Entesar H. El-Araby;A. Azazi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4096-4101
    • /
    • 2023
  • Radon is a radioactive gas produced from the uranium-238 series. Radon gas affects public health and is the second cause of lung cancer. The study samples were collected from one area of the city of Jazan, southwest of the Kingdom of Saudi Arabia. The influence of engineering and physical parameters on the emanation coefficient of gas and other gas parameters was studied. Parameters for radon were measured using a CR-39 Solid-State Nuclear Track Detector (SSNTD) through a sealed emission container. The results showed that the emanation coefficient was affected directly by the change in the grain size of the soil. All parameters of measured radon gas have the same behavior as the emanation coefficient. The relationship between particle size and emanation coefficient showed a good correlation. The values of the emanation coefficient were inversely affected by the mass of the sample, and the rest of the parameters showed an inverse behavior. The results showed that increasing the volume of the container increases the accumulation of radon sons on the wall of the container, which increases the emission factor. The rest of the parameters of radon gas showed an inverse behavior with increasing container size. The results concluded that changing the engineering and physical parameters has a significant impact on both the emanation coefficient and all radon parameters. The emanation coefficient affects the values of the radiation dose of an alpha particle.

Relationship between the values of blood parameters and physical status in Korean native calves with diarrhea

  • Lee, Sung-Hwan;Choi, Eun Wha;Kim, Doo
    • Journal of Veterinary Science
    • /
    • v.21 no.2
    • /
    • pp.17.1-17.11
    • /
    • 2020
  • Dehydration, electrolyte disturbance, and acid-base imbalance are the most significant consequences of diarrhea in calves. We aimed to determine blood gas, hematological, electrolyte, and biochemical values and investigate the relationship between the physical status and blood parameters in Korean native calves (KNCs) with diarrhea. One hundred eighty KNCs with diarrhea (age < 75 days) were investigated. Blood samples were collected from the external jugular vein and analyzed using a portable clinical blood gas analyzer. The measured parameters were statistically compared according to the status of physical activity, dehydration, or prognosis. The mean values of parameters in the Calves with diarrhea showed metabolic acidosis, hyponatremia, and azotemia. The mean values of potassium, chloride, hematocrit, and hemoglobin were in the upper limit of their reference ranges. More than 75% of the calves had metabolic acidosis caused by bicarbonate loss, and 63.6% had high blood urea nitrogen (BUN) values. Moreover, BUN showed the highest correlation with the physical activity status and dehydration. pH, base excess of the extracellular fluid (BE), anion gap, potassium, hematocrit, bicarbonate, and hemoglobin were closely correlated with physical deterioration and dehydration (p < 0.001). BUN, pH, BE, and anion gap were closely correlated with physical deterioration and dehydration. These correlations between clinical symptoms and blood gas parameters can be clinically relevant in predicting the status of parameters according to clinical symptoms.

The Comparative Study on Age-associated Gait Analysis in Normal Korean (우리나라 연령별 보행분석 비교연구)

  • Yoon, Na-Mi;Yoon, Hee-Jong;Park, Jang-Sung;Jeong, Hwa-Su;Kim, Geon
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.2
    • /
    • pp.15-23
    • /
    • 2010
  • Purpose: This study was done to establish reference data for temporo-spatial, kinematic and kinetic parameters for normal Koreans as they age. Methods: Normal adults and children without a previous history of musculoskeletal problems were enrolled in this study. The normal subjects were divided by age into three groups: Group I: children ($11.95{\pm}0.29$ years); Group II: young adults ($23.90{\pm}3.67$ years); Group III: older adults ($71.40{\pm}4.08$ years). The temporo-spatial and kinematic data were measured using 6 MX3 cameras while each subject walked through a 10 m walkway at a self-selected speed. The kinetic data were measured using 2 force plates and were calculated by inverse dynamics. Results: Motion patterns are typically associated with a specific phase of the gait cycle. Our results were as follows: 1. There were significant differences between the different age groups in temporo-spatial parameters such as cadence, double support, time of foot off, stride length, step length, and walking speed. 2. There were significant differences between the groups in kinematic parameters such as range of motion (ROM) of the hip, knee and ankle in the sagittal plane, ROM of the pelvis, hip and knee in the coronal plane and ROM of the pelvis, hip and ankle in the transverse plane. 3. There were significant differences between the groups in kinetic parameters such as joint moments of force, joint mechanical power generation or absorption and ground reaction forces. Conclusion: The results of this study can be utilized (a) as a reference for kinematic and kinetic data of gait analysis in normal Koreans, and (b) as an aide in evaluating and treating patients who have problems relating to gait.