• Title/Summary/Keyword: Photovoltaic array (PV)

Search Result 188, Processing Time 0.026 seconds

A Study on the Optimal Design of Large-scale Photovoltaic Array (대용량 PV 어레이의 최적설계에 관한 연구)

  • Hwang, In-Ho;Kim, Eui-Hwan;Ahn, Kyo-Sang
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.8-14
    • /
    • 2011
  • Recently, a number of large-scale photovoltaic(PV) power generation system has been installed all over the world. Thus, in order to improve the system efficiency, the optimal design of the large-scale PV systems has become an important issue. DC cable loss of PV array is one of the design factors related to the system efficiency. This paper introduces the array design method of a 500kW Photovoltaic power plant. Three types of the PV array are suggested. Also, string cables, sub-array cables and array cables are designed within 1% of voltage drop in the line, and the DC cable losses are analyzed. The results of this paper show that the DC cable loss of large-scale PV array can be reduced by adopting a proper sub-array design method.

Impedance Analysis and Surge Characteristics of PV Array

  • Lee, Ki-Ok;So, Jeong-Hoon;Yu, Gwon-Jong;Park, Ju-Yeop
    • Journal of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.259-264
    • /
    • 2003
  • Photovoltaic (PV) array, which is generally installed outside, has the possibility of being damaged by high voltage due to lightning. primarily because the electrical characteristics of PV array have not been fully identified by lightning yet, there is a very important issue whether PV array should be connected with a ground or not. In this paper, a basic model of PV array is provided considering the PV cell's barrier capacitance and ground capacitance for analysis of electrical characteristics by lightning.

Study for Reducing Ripples of the PV Array Output in Grid-Connected Photovoltaic Power System (계통연계헝 태양광인버터의 PV Array 출력리플 저감을 위한 연구)

  • Kim, Hee-Jung;Chung, Yong-Ho;Lee, Ki-Su;Jon, Young-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.202-205
    • /
    • 2006
  • In the PV power system, output of the PV array must contain inherent ripples due to the single-phase inverter. So the function of maximum power point tracking to increase the output efficiency of PV system is degraded. Therefore, to overcome this problem, this paper presents a control strategy for the reducing ripples of the PV array output in grid-connected photovoltaic power system. The proposed control system consists of two loops the maximum power point tracking loop using the perturbation and observation method is used to calculate the reference solar array terminal voltage(Vref) for reducing ripples of the PV array output and the PI control loop is used to regulate the solar array output voltage according to the Vref. The performance of proposing control strategy is analyzed by means of the PSCAD/EMTDC simulation. As a result, we may obtain the high performance of the proposed control strategy.

  • PDF

Study on the Grid-connected Photovoltaic Power System for Reducing Ripples of the PV Array Output (PV Array 출력리플 저감을 위한 계통연계형 태양광 인버터에 관한 연구)

  • Kim, H.J.;Chung, Y.H.;Lee, K.S.;Jon, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1211-1212
    • /
    • 2007
  • In the PV power system, output of the PV array must contain inherent ripples due to the single-phase inverter. So, the function of maximum power point tracking to increase the output efficiency of PV system is degraded. Therefore, to overcome this problem, this paper presents a control strategy for the reducing ripples of the PV array output in grid-connected photovoltaic power system. The proposed control system consists of two loops; the maximum power point tracking loop using the perturbation and observation method is used to calculate the reference solar array terminal voltage(Vref) for reducing ripples of the PV array output and the PI control loop is used to regulate the solar array output voltage according to the Vref. The performance of proposing control strategy is analyzed by means of the PSCAD/EMTDC simulation and experiment. As a result, we may obtain the high performance of the proposed control strategy.

  • PDF

On Line Monitoring and Diagnosis Technique for the Array of Photovoltaic Energy System (태양광 발전시스템 전지모듈의 온라인 감시 진단 시스템 개발)

  • Lee, Jong-Pil;Ji, Pyeong-Shik;Byun, Sang-Zoon;Lim, Jae-Yoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.4
    • /
    • pp.168-172
    • /
    • 2007
  • The global environment deteriorating which originated from using of fossil fuel is an serious problem for human being to solve. The photovoltaic energy has been considered as a solution. In advanced countries, research and development for photovoltaic(PV) energy system is carrying on. Once installed, a PV array requires maintenance and fault diagnosis other than an occasional cleaning. In this research, the proposed system monitor and diagnosis the output of PV array by on-line for maintenance of PV power plant. The validity of proposed system is verified using sample system.

A Study on PV System Output Changes by PV Array Installation Position and Mount Angle Change (태양광 어레이 설치 위치 및 각도변경 전후의 태양광 발전 시스템의 출력 변화에 관한 연구)

  • Yoon, Jeong-Phil;Cha, In-Su;Choi, Jeong-Sik;Kim, Dong-Mook;Park, Jong Bock;Ha, Min Ho;Kim, Won Bae
    • Current Photovoltaic Research
    • /
    • v.2 no.4
    • /
    • pp.189-194
    • /
    • 2014
  • In this paper, We have simulated the output variation of the PV arrays installation with position & angle change. The existing 3 solar array system are $43^{\circ}$ southeast and each of the mounting angle is $17^{\circ}$. The PV output power is 240 kW. The composite studied systems in this paper arrays altered 2 PV array among 3 PV array system- the output 144kW. We simulated this system using Solar Pro ver.4.1. The simulation conditions are southwest $43^{\circ}/array$, mount angle $27^{\circ}/array$. Because the southeast have shadow effect-higher mountain The purpose of southwest $43^{\circ}$ is reduce the shadow effect. The simulation results of the suggestion design algorithm compared to 1,590 kWh/year output is increased with the southeast.

Modeling and Simulation Analysis of Grid-Connected Photovoltaic Generation System in terms of Dynamic behavior (계통연계형 태양광발전시스템의 동특성 모델링 및 모의해석)

  • Kim, Eung-Sang;Kim, Seul-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.127-131
    • /
    • 2005
  • The paper addresses modeling and analysis of a grid-connected photovoltaic generation system (PV system). PSCAD/EMIDC. an industry standard simulation tool for studying the transient behavior of electric power system and apparatus. is used to conduct all aspects of model implementation and to carry out extensive simulation study. An equivalent circuit model of a solar cell has been used for modeling solar array. A PWM voltage source inverter (VSI) and its current control scheme have been implemented. A maximum power point tracking (MPPT) technique is employed for drawing the maximum available energy from the PV array. Comprehensive simulation results are presented to examine PV array behaviors and PV system control performance in response to irradiation changes. In addition, dynamic responses of PV array and system to network fault conditions are simulated and analysed

  • PDF

A BIFUNCTIONAL UTILITY CONNECTED PHOTOVOLTAIC SYSTEM WITH POWER FACTOR CORRECTION AND U.P.S. FACILITY

  • Kim. S.;Yoo, Gwonjong;Song, Jinsoo
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.103-108
    • /
    • 1996
  • In this paper, a novel utility connected photovoltaic power generation system with unity power factor and uninterruptable power system facility and its control strategy are proposed. The proposed photovoltaic(PV) system is connected in parallel between utility and load. The PV system provides an uninterruptable voltage to load, a maximum power tracking to solar array, and power factor correction to the utility. The proposed system has the following advantages compared with the conventional utility connected PV system. 1. Harmonic elimination Function 2. Feeding the photovoltaic energy to the utility 3. Providing the uninterruptible power source along battery to the load In case that the photovoltaic array system is on the poor power generation, the battery and capacitor of the PV system are charged by three phase utility source and the inverter in the PV system only provides the reactive current to eliminate the harmonic current exited on the utility. In the normal operation mode, the PV system supplies active power to load and reactive power to utility in order to maintain the unity power factor and to regulate ac load voltage.

  • PDF

Development of PSCAD User-defined Model for the Simulation of a PV Array (PV 어레이의 계통연계 모의를 위한 PSCAD 사용자 정의 모델 개발)

  • Ahn, Seon-Ju;Choi, Joon-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.134-139
    • /
    • 2011
  • Since large and small scale photovoltaic(PV) systems have been commercialized in many countries, it is necessary to assess the effects of PV systems on the electric power system. For this, the development of accurate simulation model of PV arrays is very important. PSCAD/EMTDC, a widely used simulation tool for analyzing the transient behavior of electrical apparatus and networks, does not have a standard model of a PV array. Therefore in order to simulate the PV array, users have to develop their own simulation model. However, the block-diagram-based model is very complicated, and it is hard to modify the model parameters. In this study, we develop the user-defined model of a PV array by using the Design Editor, which is provided by PSCAD program. The mathematical model of a PV array and the method to determine the parameters of nonlinear I-V equation are implemented in a Fortran code. The graphical user interface provides the users with easy and simple way to modify the PV array parameters and simulation conditions. In order to help the users, this model also provides the parameters of 10 commercial PV arrays.

The Influence of Changing PV Array Interconnections under a Non-uniform Irradiance

  • Ding, Kun;Feng, Li;Qin, Si-Yu;Mao, Jing;Zhang, Jing-Wei;Wang, Xiang;Peng, Tao;Zhai, Quan-Xin
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.631-642
    • /
    • 2016
  • Usually, the output characteristics of a photovoltaic (PV) array are significantly affected by non-uniform irradiance which is caused by ambient obstacles, clouds, orientations, tilts, etc. Some local maximum power points (LMPP) in the current-voltage (I-V) curves of a PV array can result in power losses of the array. However, the output power at the global maximum power point (GMPP) is different in different interconnection schemes in a PV array. Therefore, based on the theoretical analysis and mathematical derivation of different topological structures of a PV array, this paper investigated the output characteristics of dual series PV arrays with different interconnections. The proposed mathematical models were also validated by experimental results. Finally, this paper also concluded that in terms of performance, the total cross tied (TCT) interconnection was not always the optimal structure, especially in a dual series PV array. When one of the PV modules was severely mismatched, the TCT worked worse than the series parallel (SP) structure. This research can provide guidance for switching the interconnection to gain the greatest energy yield in a changeable- structure PV system.