PV의 건축물 적용기법에 관한 연구 (A Study on the Application Method of Photovoltaic in Building)

  • 이응직;김회서
    • 한국태양에너지학회 논문집
    • /
    • 제22권2호
    • /
    • pp.1-10
    • /
    • 2002
  • This study is a study on the building integrated method of Photovoltaic. It was analyzed into a basic installation condition and an integrated form in this study. And it was confirmed through the 3D simulation & drawing work of an integrated situation to the real domestic building. The Photovoltaic installation of the country to an optimal efficiency for the year must be installed to the due south with an angle of thirty degrees. And also a module spacing must be more than doubled from the bottom to the top of module to prevent from efficiency falling by a shadow of photovoltaic module in a roof setting of flat roof. If Photovoltaic module is an adequate material that is a basic requirement as a building's finishing material, it's not only an efficiency of alternation with an existing finishing material but also a building's design element.

건축물에 적용된 태양광발전시스템의 운전실태 조사 및 보급 확대에 관한 연구 (A Study on Investigating Actual State of Operation of Building Integrated Photovoltaic for the Spread of BIPV)

  • 김병준;김주영;홍원화
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2005년도 추계학술대회 논문집
    • /
    • pp.327-330
    • /
    • 2005
  • Today, the need for alternative energy has increased due to the global environmental problems and energy depletion. In order to solve a global environmental matter and an energy issue simultaneously, the application of the renewable energies in building has been constantly demanded. therefore, we must develop new energy resources that are abundant and provide substitutes for fossil fuels and we must study the application method of the renewable energies in building. Among renewable energies, the solar energy(photovoltaic system) is clean, inexhaustible, and available everywhere in the world and is judged to have the application possibility in building. Daegu city has a plan of putting a photovoltaic system on large buildings. For instance, EXCO, exhibition and convention building, and dormitory in Kyungpook National University, Dongho elementary school, Osan building in Keimyung University, Young korea academy in Daegu, are on the process of having a photovoltaic system. Therefore a study on the performance of photovoltaic system is important for the system design and maintenance. this paper describes the first invest cost, and performance test of the 95kW utility-interactive photovoltaic power system.

  • PDF

초고층 건축물 시공단계를 위한 태양광시스템의 적용성 분석 (Applicability Analysis of Photovoltaic System in the Construction Phase of High-rise Buildings)

  • 강고운;김태훈;조훈희;강경인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.21-22
    • /
    • 2011
  • Recently, the development of alternative energy technologies has been actively conducted for energy conservation and CO2 emission reduction. Especially, photovoltaic energy has been applied practically in construction industry, and research on the building-integrated photovoltaic system (BIPV) that can replace fossil fuel for building operation and maintenance has been performed. However, this vibrant research has been limited to the use phase of buildings, and few studies have been carried out in the construction phase. The construction duration and the scale of the sites have increased along with the high-rise trend of buildings, and it is forecasted that the temporary electricity use and CO2 emission in the construction phase is increasing. In sight of these developments, this research analyzed applicability of the photovoltaic system for the construction phase that can replace the electricity used on the high-rise construction site.

  • PDF

대학건물의 전력소비패턴 분석을 통한 태양광, ESS 적정용량 산정 및 경제적 효과 분석 (Calculation of Photovoltaic, ESS Optimal Capacity and Its Economic Effect Analysis by Considering University Building Power Consumption)

  • 이혜진;최정원
    • 한국산업융합학회 논문집
    • /
    • 제21권5호
    • /
    • pp.207-217
    • /
    • 2018
  • Recently, the importance of energy demand management, particularly peak load control, has been increasing due to the policy changes of the Second Energy Basic Plan. Even though the installation of distributed generation systems such as Photovoltaic and energy storage systems (ESS) are encouraged, high initial installation costs make it difficult to expand their supply. In this study, the power consumption of a university building was measured in real time and the measured power consumption data was used to calculate the optimal installation capacity of the Photovoltaic and ESS, respectively. In order to calculate the optimal capacity, it is necessary to analyze the operation methods of the Photovoltaic and ESS while considering the KEPCO electricity billing system, power consumption patterns of the building, installation costs of the Photovoltaic and ESS, estimated savings on electric charges, and life time. In this study, the power consumption of the university building with a daily power consumption of approximately 200kWh and a peak power of approximately 20kW was measured per minute. An economic analysis conducted using these measured data showed that the optimal capacity was approximately 30kW for Photovoltaic and approximately 7kWh for ESS.

비정형 건물일체형 태양광 발전 시스템 규칙기반 BIM설계 지원 도구 개발 (Development of a Rule-based BIM Tool Supporting Free-form Building Integrated Photovoltaic Design)

  • 홍성문;김대성;김민철;김주형
    • 한국BIM학회 논문집
    • /
    • 제5권4호
    • /
    • pp.53-62
    • /
    • 2015
  • Korea has been at the forefront of green growth initiatives. In 2008, the government declared the new vision toward 'low-carbon society and green growth'. The government subsidies and Feed-in Tariff (FIT) increased domestic usage of solar power by supplying photovoltaic housing and photovoltaic generation systems. Since 2000, solar power industry has been the world's fastest growing source with the annual growth rate of 52.5%. Especially, BIPV(Building Integrated Photovoltaic) systems are capturing a growing portion of the renewable energy market due to several reasons. BIPV consists of photovoltaic cells and modules integrated into the building envelope such as a roof or facades. By avoiding the cost of conventional materials, the incremental cost of photovoltaics is reduced and its life-cycle cost is improved. When it comes to atypical building, numerous problems occur because PV modules are flat, stationary, and have its orientation determined by building surface. However, previous studies mainly focused on improving installations of solar PV technologies on ground and rooftop photovoltaic array and developing prediction model to estimate the amount of produced electricity. Consequently, this paper discusses the problem during a planning and design stage of BIPV systems and suggests the method to select optimal design of the systems by applying the national strategy and economic policies. Furthermore, the paper aims to develop BIM tool based on the engineering knowledge from experts in order for non-specialists to design photovoltaic generation systems easily.

대구광역시 건축물 적용 태양광발전시스템의 경제성 및 환경성 평가에 관한 연구 (A Study on Economic and Environmental Evaluation of Building Integrated Photovoltaic in Daegu)

  • 소재억;김주영;홍원화
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1232-1237
    • /
    • 2006
  • In Daegu, spread works of photovoltaic have were carrying out from a part of the solar city Daegu but, actual results have were insignificant. According to this study, it analyzed actual conditions of four building integrated photovoltaic system proper to the subject of investigation in Daegu City, in order to investigate the cause of inactive spread of building integrated photovoltaic system. After analyzing of actual state and performance, this study will present not only economic evaluation that Is problem of spread but also, environment evaluation by estimating to have an effect on greenhouse gas reduction.

  • PDF

후면부재에 따른 BIPV 모듈의 특성 분석 (Characteristic Analysis of BIPV Module according to Rear Materials)

  • 김현일;강기환;박경은;유권종;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제29권4호
    • /
    • pp.28-33
    • /
    • 2009
  • In 2008, the global photovoltaic(PV) market reached 5.6GW and the cumulative PV power installed totalled almost 15GW compared to 9GW in 2007. Due to a favourable feed-in-tariff, Korea emerged in 2008 as the 4th largest PV market worldwide. PV power installation rose 495.5 percent to 268MW in 2008 compare to 45MW in 2007. Building integrated photovoltaic(BIPV) has the potential to become a major source of renewable energy in the urban environment. BIPV has significant influenced on the reflection by rear materials such as white back sheet and the heat transfer through the building envelope because of the change of the thermal resistance by adding or replacing the building elements. In this study, to use as suitable building materials into environmentally friendly house like green home, characteristic analysis of BIPV module according to rear materials achieved. Electrical output of PV module with white back sheet is high about 10% compared to other pv module because of 83% reflectivity of white back sheet compared to 8.4% reflectivity of other PV modules with different rear materials(black back sheet and glass). In the result of outdoor experiment during a year, electrical output of four different PV module is decreased about 3.72%.

Building-Integrated Photovoltaic 시스템의 연간 발전 에너지 향상을 위한 커버글라스 패턴의 최적설계 (Optimal Design of Coverglass Pattern in Building-Integrated Photovoltaic for Improved Yearly Electrical Energy)

  • 김태현;이승철;박우상
    • 한국전기전자재료학회논문지
    • /
    • 제33권4호
    • /
    • pp.297-302
    • /
    • 2020
  • A coverglass pattern was designed to improve the annual electrical energy production of a building-integrated photovoltaic (BIPV) module installed in the exterior walls of buildings. The transmittance pattern was calculated using ray tracing, and the results were derived by optimizing the simulation using Taguchi's method. We obtained the optimal pattern by analyzing the conventional patterns for improving the transmittance and derived design factors by quantifying the pattern. By calculating the influence of electrical energy on each design factor, we obtained the optimal coverglass pattern that produced the maximum annual electrical energy. The annual electrical energy production improved by approximately 11.79% compared to the non-patterned coverglass.

12kW급 건물일체형 태양광발전시스템 사례분석 (Case Study on 12kW Building Integrated Photovoltaic System)

  • 박경은;강기환;김현일;소정훈;유권종;김준태;이길송
    • 한국태양에너지학회 논문집
    • /
    • 제29권1호
    • /
    • pp.18-23
    • /
    • 2009
  • We intend to describe a 12kW building-integrated photovoltaic system which was applied into the south wall of a new building. This study showed the results that were appeared from describing the PV module manufacture and installation process, and performing generation performance analysis of BIPV system. From the result we confirmed that the generation performance of the BIPV system was changed by season. The performance ratio(PR) was about 83.6% in winter and it means that performance of this BIPV system was so good in that season. On the other hand, the PR in summer was about 75.0% dropped about 8%. It was believed that the change was influenced by the reduction of solar radiation irradiated into the PV modules by installation position and rainy spell in summer. And we also confirmed that low irradiation condition is cause of the additional loss in the total PV system. In this case, the efficiency ratio of PCS drops significantly at low input loads and the average conversion efficiency of PCS in summer was 76.4% decreased about 10% from 86% in winter.

Toward Net-Zero Energy Retrofitting: Building-Integrated Photovoltaic Curtainwalls

  • Kim, Kyoung Hee;Im, Ok-Kyun
    • 국제초고층학회논문집
    • /
    • 제10권1호
    • /
    • pp.35-43
    • /
    • 2021
  • With the rapid urbanization and growing energy use intensity in the built environment, the glazed curtainwall has become ever more important in the architectural practice and environmental stewardship. Besides its energy efficiency roles, window has been an important transparent component for daylight penetration and a view-out for occupant satisfaction. In response to the climate crisis caused by the built environment, this research focuses on the study of net-zero energy retrofitting by using a new building integrated photovoltaic (BIPV) curtainwall as a sustainable alternative to conventional window systems. Design variables such as building orientations, climate zones, energy attributes of BIPV curtainwalls, and glazed area were studied, to minimize energy consumption and discomfort hours for three cities representing hot (Miami, FL), mixed (Charlotte, NC), and cold (Minneapolis, MN). Parametric analysis and Pareto solutions are presented to provide a comprehensive explanation of the correlation between design variables and performance objectives for net-zero energy retrofitting applications.