• Title/Summary/Keyword: Photon Search

Search Result 13, Processing Time 0.016 seconds

Brightness and Fluctuation of Mid-Infrared Sky from AKARI Observations

  • Pyo, Jeong-Hyun;Matsumoto, Toshio;Jeong, Woong-Seob;Matsuura, Shuji
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.117.1-117.1
    • /
    • 2011
  • We present the smoothness of mid-infrared sky brightness from the Japanese infrared astronomical satellite, AKARI observations. AKARI monitored the north ecliptic pole (NEP) during its cold phase with nine wavebands from 2.4 to 24 ${\mu}m$, out of which six mid-infrared bands are used in this study. Simple sinusoidal fit to the seasonal variation of the sky brightness shows that the mid-infrared brightness towards the NEP is not affected by small-scale features of the interplanetary dust cloud. We applied the power spectrum analysis to the images to search for the fluctuation of sky brightness. The fluctuation powers at 200 arcsecond are estimated to be at most $1.58{\pm}0.33\;nW\;m^{-2}sr^{-1}$ or 0.13% of the total brightness at $7{\mu}m$ and a tleast $0.64{\pm}0.11\;nW\;m^{-2}sr^{-1}$ or 0.02% at $18{\mu}m$. The residual fluctuations at a few arcminute scales at short mid-infrared wavelengths (7, 9, and 11 ${\mu}m$) are consistent with those expected from the diffuse galactic light. At long mid-infrared wavelengths (15, 18, and 24 ${\mu}m$) the measured fluctuations are comparable to or smaller than the one caused by photon noise and their sources are not identified. We conclude that the upper limit of the fluctuation in the zodiacal light is about 0.02% of the sky brightness.

  • PDF

Development of Monte Carlo Simulation Code for the Dose Calculation of the Stereotactic Radiosurgery (뇌 정위 방사선수술의 선량 계산을 위한 몬테카를로 시뮬레이션 코드 개발)

  • Kang, Jeongku;Lee, Dong Joon
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.303-308
    • /
    • 2012
  • The Geant4 based Monte Carlo code for the application of stereotactic radiosurgery was developed. The probability density function and cumulative density function to determine the incident photon energy were calculated from pre-calculated energy spectrum for the linac by multiplying the weighting factors corresponding to the energy bins. The messenger class to transfer the various MLC fields generated by the planning system was used. The rotation matrix of rotateX and rotateY were used for simulating gantry and table rotation respectively. We construct accelerator world and phantom world in the main world coordinate to rotate accelerator and phantom world independently. We used dicomHandler class object to convert from the dicom binary file to the text file which contains the matrix number, pixel size, pixel's HU, bit size, padding value and high bits order. We reconstruct this class object to work fine. We also reconstruct the PrimaryGeneratorAction class to speed up the calculation time. because of the huge calculation time we discard search process of the ThitsMap and used direct access method from the first to the last element to produce the result files.

Dosimetric Characteristics of Dual Photon Energy Using Independent Collimator Jaws (고에너지 선형가속기의 Independent Collimator를 이용한 비대칭 방사선 조사시 방사선량 결정에 미치는 요인에 관한 연구)

  • Kim Jeung-kee;Choi Young-Min;Lee Hyung-Sik;Hur Won-Joo
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.237-244
    • /
    • 1996
  • Purpose : The accurate dosimetry of independent collimator equipped for 6MV and 15MV X-ray beam was investigated to search for the optimal correction factor. Materials and Methods : The field size factors, beam quality and dose distribution were measured by using 6MV, 15MV X-ray Field size factors were measured from $3{\times}3cm^2$ to $35{\times}35cm^2$ by using 0.6cc ion chamber (NE 2571) at Dmax. Beam qualities were measured at different field sizes, off-axis distances and depths. Isodose distributions at different off-axis distance using $10\times10cm^2$ field were also investigated and compared with symmetric field. Result: 1) Relative field size factors was different along lateral distance with maximum changes in $3.1\%$ for 6MV and $5\%$ for 15MV. But the field size factors of asymmetric fields were identical to the modified central-axis values in symmetric field, which corrected by off-axis ratio at Dmax. 2) The HVL and PDD was decreased by increasing off-axis distance. PDD was also decreased by increasing depth For field size more than $5{\times}cm^2$ and depth less than 15cm, PDD of asymmetric field differs from that of symmetric one ($0.5\~2\%$ for 6MV and $0.4\~1.4\%$ for 15MV). 3) The measured isodose curves demonstrate divergence effects and reduced doses adjacent to the edge close to the flattening filter center was also observed. Conclusion . When asymmetric collimator is used, calculation of MU must be corrected with off-axis and PDD with a caution of underdose in central axis.

  • PDF