• Title/Summary/Keyword: Photon Knife

Search Result 8, Processing Time 0.021 seconds

Verification of Target Position in Stereotactic Radiosurgery Based on Photon Knife System (Photon Knife 시스템에 근거한 뇌정위 방사선수술에서 표적위치 확인)

  • 최태진;김진희;김옥배
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.99-107
    • /
    • 2003
  • This study was performed to prepare the verification film for localizing beam-target position with the Photon Knife radiosurgery system (PKRS) using linear accelerator(Mitsubishi, Model ML-15MDX). We developed a laser calibration system using a reticle of transparent lucite to detect Inlet and outlet beams. We verified fixation of the second collimator with film mounted on a holder in the shape of an octagon block 5cm apart from the isocenter. The film was exposed to photon beams of linear accelerator at an interval of 45 degrees during the gantry movement. There were no shifts in the beam of the second collimator during gantry movement. We used a position marker which is designed a head-shaped small lead block and a 10 mm in diameter of steel bead in the plastic tube. The position marker helped to verify the beam directions with patient position in multi-arc and trans-multi-arc of PKRS The verification of beam alignments showed an average 0.8$\pm$0.26 mm discrepancy in LINAC-gram images of PKRS. In our study, the couch movement was $\pm$5 mm laterally, while it shook $\pm$ 2 mm toward the couch axis. The couch, however, was immediately returned to the initial site after shaking. Thus, we postulate that the beam-target position(s) should be verified with LINAC-gram in a stereotactic radiosurgery system to achieve the accuracy of beam-target alignment.

  • PDF

Radiosurgery with Linac Based Photon Knife in Cerebral Arteriovenous Malformation (선형가속기를 이용한 Photon Knife 방사선수술에 의한 뇌동정맥기형의 치료)

  • Kim, Jin-Hee;Choi, Tae-Jin
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.1-9
    • /
    • 2003
  • Purpose : The purpose of this study was to analyze the effect of a Linear accelerator based Photon Knife Radiosurgery System developed by the staff of Keimyung University Dongsan Medical Center for the treatment of cerebral arterlovenous malformation Material and Methods : Between December 1993 and October 2000, 30 patients with cerebral arteriovenous malformation (AVM) were treated with the Linac based Photon knife Radlosurgery System In the Department of Therapeutlc Radiology at Keimyung University Dongsan Medical Center. The median age was 34, ranging from 7 to 63 years, with a 2 : 1 male to female ratio. The locations of the AVM nidi were the frontal lobe (motor cortex), parletal lobe, and the thalamus, In that order. The diameters of the AVM nidi ranged 1.2 to 5.5 cm with a mean on 2.9 cm, and target volumes of between 0.5 and 20.5 cc, with a mean of 5.8 cc. The majority of patients received radiation doses of between 1,500 and 2,500 cGy, w14h a mean of 2,000 cGy, at 80% the isodose line. Twenty-five patients were treated with one isocenter, 4 with two, and 1 with four. The follow-up radiological evaluations were peformed with cranial computed tomogram (CT) or MRI between 6 month and one year interval, and if the AVM nidus had completely disappeared in the CT or MRI, we confirmed thls was a complete obliteration, with a cerebral or magnetic resonance angiogram (MRA). The median iollow-up period was 39 months with a range of 10 to 103 months. Results : Twenty patients were radloiogicaiiy followed up ior over 20 months, with complete obliteration observed in 14 (70%). According to the maximal diameter, all four of the small AVM (<2 cm) completely obliterated, 8 of the 10 patients with a medium AVW (2~3 cm) showed a complete obliteration, and two showed partial obliteration. Among the patients with a large AVM (>3 cm), only one showed complete obliteration, and S showed partial obliteration, but 3 oT these underwent further radiosurgery 3 years later. One who followed up for 20 months fellowing further radiosurgery eventually showed complete obliteration. Ten patients with seizure symptoms had no recurrent seizure due to radiosurgery and medication. One of the eleven patients who suffered intracranlal bleeding developed further bleeding at 9 and 51 months fellowing the radiosurgery although complete obliteration was eventually observed and the patient was managed in hospital then recovered. No patient suffered severe complications fellowing the radiosurgery. Conclusion : The radiosurgery with Linac-based Photon knife radiosurgery system, developed by the staff at our hospital, is a safe and effective treatment for AVM patients having diameters or volumes of less than 3 cm or 10 cm$^{3}$, respectively, located In Inoperable areas or who refused neurosurgery. We suggest that staged AVM radiosurgery may initially be considered, if the AVM target volume is above 10 cm$^{3}$

Methodologic Aspect of LINAC-based Stereotactic Radiosurgery (선형가속기 기반 뇌정위 방사선 수술기법)

  • Choi, Tae Jin
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.127-137
    • /
    • 2012
  • A conversing beam is firstly designed for radiosurgery by a neurosugern Lars Leksell in 1949 with orthogonal x-rays tube moving through horizontal moving arc to focusing the beam at target center. After 2 decades he composits 201 source of the Co-60 for gamma knife which beams focused at locus. Sveral linac-based stereotactic radiosurgery using the circular collimated beam which size range for 0.4~4.0 cm in a diameter by non-coplanar multiarc have been developed over the decades. The irregular lesions can be treated by superimposing with several spherical shots of radiation over the tumour volume. Linac based techniques include the use of between 4 and 11 non-co-planar arcs and a dynamic rotation technique and use photon beam energies in the range of 6~10 MV. Reviews of the characteristics of several treatment techniques can be found in the literature (Podgorsak 1989, Schell 1991). More in recent, static conformal beams defined by custom shaped collimators or a mini- or micro-multileaf collimator (mMLC) have been used in SRS. Finally, in the last few years, intensity-modulated mMLC SRS has also been introduced. Today, many commercial and in-house SRS programs have also introduced non-invasive immobilization systems include the cyberknife and tomotherapy and proton beam. This document will be compared the characteristics of dose distribution of radiosurgery as introduced gamma knife, BrainLab include photon knife in-house SRS program and cyberknife in currently wide used for a cranial SRS.

A New Approach with Combined Stereotactic Trans-multiarc Beams for Radiosurgery Based on the Linear Accelerator : Photon Knife (입체적횡다증회전조사를 병합한 방사선수술의 새로운 접근 : 포톤나이프)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.149-158
    • /
    • 1996
  • Purpose : To get an accute steepness of dose gradients at outside the target volume in intracranial lesion and a less limitation of beam selection avoiding the high dose at normal brain tissue, this Photon Knife Radiosurgery System was developed in order to provide the three-dimensional dose distribution through the reconstruction of CT scan and the combined stereotactic trans-multiarc beam mode based on linear accelerator photon beam. Materials and methods : This stereotactic radiosurgery, Photon Knife based on linear accelerator photon beam was provided the non-coplanar multiarc and trans-multiarc irradiations. The stereotactic trans-multiarc beam mode can be obtained from the patient position in decubitus. This study has provided the 3-dimensional isodose curve and anatomical structures with the surface rendering technique. The dose distribution from the combined two trans-multiarcs (2M 2TM) was compared to that of four non-coplanar multiarcs (4M) with same collimator size of 25 mm in a diameter and total gantry movements. Results : In this study, it shows that the dose distributions of stereotactic beam mode are significantly depended on the selected couch and gantry angle in same collimator size. Practical dose distribution of combined stereotactic trans-multiarc beam has shown a more small rim thickness than that of the non-coplanar multiarc beam mode in axial, sagittal and coronal plane in our study. 3-Dimensional dose line displayed with surface rendering of irregular target shape is helpful to determine the target dose and to predict the prognosis in follow-up radiosurgery. Conclusions : 3-Dimensional dose line displayed with surface rendering of irregular target shape is essential in stereotactic radiosurgery. This combined stereotactic trans-multiarc beam has shown a less limitation of the selection couch and gantry beam angles for the target surrounding critical organs. It has shown that the dose distribution of combined trans-multiarc beam greatly depended on the couch and gantry angles. In our experiments, the absorbed dose has been decreased to $27%$ / mm in maximum at the interval of $50\%$ to $80\%$ of isodose line.

  • PDF

Linac Based Radiosurgery for Cerebral Arteriovenous Malformations (선형가속기 방사선 수술을 이용한 뇌동정맥기형의 치료)

  • Lee, Sung Yeal;Son, Eun Ik;Kim, Ok Bae;Choi, Tae Jin;Kim, Dong Won;Yim, Man Bin;Kim, In Hong
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.8
    • /
    • pp.1030-1036
    • /
    • 2000
  • Objective : The aim of this study was to retrospectively analyze the safety and effect of Linac based Photon Knife Radiosugery System(PKRS) for treatment of cerebral arteriovenous malformation. Patients and Methods : The authors analyzed the clinical method and results of ten patients who were followed up more than two years, among the 18 patients who had radiosurgery on arteriovenous malformation from June, 1992, to Dec. 1997, with Linac based Photon knife radiosurgery system(PKRS) which was developed in our hospital. Results : The average age of the patients was 30.4(with the range of 13-49), and the sex was seven males and three females. For the initial clinical symptoms, there were five patients with headache, three with seizure, one with hemiparesis, and one with vomiting. Before the radiosurgery, computed tomography, MRI, and cerebral angiogram were done. For the location of arteriovenous malformation, it was found on six patients of cerebral hemisphere, two of thalamus, one of brainstem, and one of corpus callosum. Regarding the size of nidus, there were seven patients of smaller than 3cm, and three patients of larger than 3cm. Computed tomography, MRI, and cerebral angiogram were done periodically for sixth months, first year, and second year after the radiosurgery of PKRS for the completeness of obliteration. Six cases showed complete obliteration, and four partial obliterations were observed among ten cases, and interestingly, six cases of complete obliteration were observed among seven cases of small AVM of smaller than 3cm(the rate of complete obliteration : 85.7%). All patients tolerated the treatment and no significant complication were seen. Conclusion : In this study, linac based radiosurgery using PKRS onto arteriovenous malformation showed excellent effects, therefore authors believe that it is an ideal method for small sized or deep seated AVM.

  • PDF

3-Dimensional Dosimetry of Small Field Photon Beam (광자선의 소조사면에서의 3차원적 선량 측정)

  • Jang, Ji-Sun;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.54-61
    • /
    • 2012
  • A polymer gel dosimeter was fabricated. A 3-dimensional dosimetry experiment was performed in the small field of the photon of the cyberknife. The dosimeter was installed in a head and neck phantom. It was manufactured from the acrylic and it was used in dosimetry. By using the head and neck CT protocol of the CyberKnife system, CT images of the head and neck phantom were obtained and delivered to the treatment planning system. The irradiation to the dosimeter in the treatment planning was performed, and then, the image was obtained by using 3.0T magnetic resonance imaging (MRI) after 24 hours. The dose distribution of the phantom was analyzed by using MATLAB. The results of this measurement were compared to the results of calculation in the treatment planning. In the isodose curve on the axial direction, the dose distribution coincided with the high dose area, 0.76mm difference on 80%, rather than the low dose area, 1.29 mm difference on 40%. In this research, the fact that the polymer gel dosimeter and MRI can be applied for analyzing a small field in a 3 dimensional dosimetry was confirmed. Moreover, the feasibility of using these for the therapeutic radiation quality control was also confirmed.

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

Feasibility Study of Dose Evaluation of Stereotactic Radiosurgery using GafChromic $EBT^{(R)}$ Film (GafChromic $EBT^{(R)}$ 필름을 이용한 뇌정위방사선치료의 선량분석 가능성 평가)

  • Jang, Eun-Sung;Lee, Chul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Purpose: We have performed SRS (stereotactic radiosurgery) for avm (arterry vein malformation) and brain cancer. In order to verify dose and localization of SRS, dose distributions from TPS ($X-Knife^{(R)}$ 3.0, Radionics, USA) and GafChromic $EBT^{(R)}$ film in a head phantom were compared. Materials and Methods: In this study, head and neck region of conventional humanoid phantom was modified by substituting one of 2.5 cm slap with five 0.5 cm acrylic plates to stack the GafChromic $EBT^{(R)}$ film slice by slice with 5 mm intervals. Four films and five acrylic plates were cut along the contour of head phantom in axial plane. The head phantom was fixed with SRS head ring and adapted SRS localizer as same as real SRS procedure. CT images of the head phantom were acquired in 5 mm slice intervals as film interval. Five arc 6 MV photon beams using the SRS cone with 2 cm diameter were delivered 300 cGy to the target in the phantom. Ten small pieces of the film were exposed to 0, 50, 100, 200, 300, 400, 500, 600, 700, 800, 900 cGy, respectively to calibrate the GafChromic $EBT^{(R)}$ film. The films in the phantom were digitized after 24 hours and its linearity was calibrated. The pixel values of the film were converted to the dose and compared with the dose distribution from the TPS calculation. Results: Calibration curve for the GafChromic $EBT^{(R)}$ film was linear up to 900 cGy. The R2 value was better than 0.992. Discrepancy between calculated from $X-Knife^{(R)}$ 3.0 and measured dose distributions with the film was less than 5% through all slices. Conclusion: It was possible to evaluate every slice of humanoid phantom by stacking the GafChromic EBT film which is suitable for 2 dimensional dosimetry, It was found that film dosimetry using the GafChromic $EBT^{(R)}$ film is feasible for routine dosimetric QA of stereotactic radiosurgery.

  • PDF