Impact of testicular shielding in liposarcoma to scrotum by using radio-photoluminescence glass dosimeter (RPLGD): a case report

  • Oonsiri, Puntiwa;Saksornchai, Kitwadee;Suriyapee, Sivalee
    • Radiation Oncology Journal
    • /
    • 제36권3호
    • /
    • pp.248-253
    • /
    • 2018
  • Radiation protection in the scrotum to reduce the risk of genetic effect in the future is very important. This study aimed to measure the scrotal dose outside the treatment fields by using the radio-photoluminescence glass dosimeter (RPLGD). The characteristics of RPLGD model GD-302M were studied. Scattered dose to scrotum was measured in one liposarcoma case with the prescribed dose of 60 Gy. RPLGDs were placed in three different locations: one RPLGD was positioned at the posterior area which closer to the scrotum, and the other two RPLGDs were placed between the penis and the scrotum. Three RPLGDs were employed in each location. The scattered doses were measured in every fraction during the whole course of treatment. The entire number of 100 RPLGDs showed the uniformity within ±2%. The signal from RPLGD demonstrated linear proportion to the radiation dose (r = 0.999). The relative energy response correction factor was 1.05. The average scrotal dose was 4.1 ± 0.9 cGy per fraction. The results presented a wide range since there was a high uncertainty during RPLGD placement. The total scrotal dose for the whole course of treatment was 101.9 cGy (1.7% of the prescribed dose). The RPLGD model GD-302M could be used to measure scattered dose after applying the relative energy correction factor.

폐암의 정위적 체부 방사선치료 시 체적 설정과 호흡주기에 따른 선량평가 (Evaluation of Dose According to the Volume and Respiratory Range during SBRT in Lung Cancer)

  • 이득희;박은태;김정훈;강세식
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권3호
    • /
    • pp.391-397
    • /
    • 2016
  • 저병기 폐암은 정위적 체부 방사선치료 방식이 높은 효과를 나타내지만, 호흡에 의한 움직임으로 인해 정확한 선량의 조사가 쉽지 않다. 이에 본 연구는 움직이는 표적을 대상으로 영상획득 방식에 따른 체적을 분석하고, 체적 설정방식 및 호흡주기에 따른 선량을 유리선량계를 이용하여 평가하였다. 그 결과, 체적 획득의 경우 4D CT가 $10.4cm^3$로 실제 체적인 $12.3cm^3$에 가장 근접한 결과를 나타냈다. 선량평가에서는 ITV가 처방선량 10, 15, 20 Gy에서 각각 10.82, 16.88, 21.90 Gy로 가장 높은 값을 보였으며, RGRT가 좀 더 높은 값을 나타내었으나 호흡주기에 따른 결과는 유의한 차이를 나타내지 않았다. 따라서 움직이는 종양의 치료 시 4D CT를 이용하여 영상을 획득 후 ITV를 설정하여 RGRT방식으로 치료하는 것이 유리할 것으로 사료된다.

자궁난관 조영술 검사 시 Speculum 재질에 따른 흡수선량의 변화에 관한 연구 (Research about the absorbed dose with speculum material-related in Hysterosalpingography)

  • 김연민
    • 대한디지털의료영상학회논문지
    • /
    • 제13권1호
    • /
    • pp.1-6
    • /
    • 2011
  • The purpose of our study was to determine the entrance surface dose and absorbed dose in ovary when using the metal speculum and plastic speculum in hysterosalpingography respectively. The examinations was performed in anthropomorphic phantom into which calibrated photoluminescence glass dosimeter were placed on symphysis pubis level surface and ovary area. We checked average fluoroscopy time and spot expose times during the hysterosalpingography. It was average fluoroscopy time 58 sec, spot expose 5 times. We divided the subjects into two different groups to used metal and plastic speculum. We measured 10 times of absorbed dose in the same condition of the anthropomorphic phantom. We compared two groups adsorbed dose on ovary with speculum material-related. The entrance surface dose on of plastic Speculum using group was average 17.23 mGy, absorbed dose on ovary was average 3.51 mGy. The entrance surface dose on ovary of metal Speculum using group was average 19.95 mGy, absorbed dose on ovary was average 4.14 mGy. Plastic speculum using group shows a decrease absorbed dose(17.9%) as compared with metal speculum using group. The method of plastic speculum using in hysterosalpingography. might provide us with lower radiation dose, especially in patients with childbearing stage.

  • PDF

CT 검사에서 유리선량계를 이용한 수정체의 비스무트 차폐 효과 (Effectiveness of Bismuth Shield to Reduce Eye Lens Radiation Dose Using the Photoluminescence Dosimetry in Computed Tomography)

  • 정미영;권대철;권수일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권3호
    • /
    • pp.307-312
    • /
    • 2009
  • CT 검사에서 수정체 차폐용 비스무트(bismuth)를 사용하여 수정체 선량의 감소효과를 유리선량계로 측정하여 비스무트 차폐효과 및 영상을 평가하였다. 안구 및 두부 CT 검사에서 차폐용 비스무트를 사용하여 수정체 선량의 감소와 차폐 효과를 평가하기 위해 인체모형 팬텀으로 유리선량계를 이용하여 수정체 선량을 평가하였다. 유리선량계를 이용하여 비스무트를 사용하기 전의 평균 선량은 21.54 mGy이었고, 사용 후의 선량은 10.46 mGy로 51.3%의 선량 감소효과가 있다. 차폐용 비스무트를 사용한 안구 64 MDCT 촬영에서 선량감소 효과가 있어 수정체를 포함한 안구 CT 스캔에서는 비스무트를 사용하여 검사하도록 권고한다.

  • PDF

치과방사선 검사에서 두부(brain)의 흡수선량 평가 (Evaluation the absorbed dose in brain of dental radiography)

  • 전운선;한동균
    • 한국방사선학회논문지
    • /
    • 제5권6호
    • /
    • pp.343-349
    • /
    • 2011
  • 치과 방사선검사에 있어 두부 내의 흡수선량에 관한 평가를 하고자 인체모형팬텀 내부의 뇌하수체와 안구, 상악동, 악하선, 갑상선, 식도에 유리형광소자를 삽입하고 X-선을 조사하였다. 사용된 장치로는 Kodak 2200, Kodak 8000C dental radiographic systems과 computed tomography(Lightspeed VCT)이고 촬영조건은 임상에서 사용하는 인자와 동일하게 설정하였다. 이때 구내 X-선 검사의 경우 흡수선량은 0.02~2.47cGy로 가장 높게 측정된 곳은 상악 대구치 촬영 시 2.47cGy인 갑상선이었고 가장 낮은 곳은 하악 전치부 촬영에서 0.02cGy인 악하선이었다. 그리고 구외 X-선 검사의 경우 흡수선량은 세파로에서 0.36~3.44cGy, 파노라마에서 0.14~12.82cGy, 전산화단층촬영에서 8.17~253.63cGy 가장 높게 측정된 곳은 상악 CT 촬영 시 253.63cGy인 악하선이었고 가장 낮은 곳은 파노라마 촬영에서 0.14cGy인 안구이었다. 구외 X-선 검사가 구내 X-선 검사 보다 많은 흡수선량이 측정되었다. 특히 CT를 이용한 검사에서는 구내 촬영보다 100배 이상 높게 측정되었다. 따라서 구외 X-선 검사에 있어서 가이드라인을 제시하여야 하며 방사선에 의한 흡수선량을 줄이기 위한 노력이 요구된다.