• Title/Summary/Keyword: Photoluminescence glass dosimeter

Search Result 5, Processing Time 0.023 seconds

Impact of testicular shielding in liposarcoma to scrotum by using radio-photoluminescence glass dosimeter (RPLGD): a case report

  • Oonsiri, Puntiwa;Saksornchai, Kitwadee;Suriyapee, Sivalee
    • Radiation Oncology Journal
    • /
    • v.36 no.3
    • /
    • pp.248-253
    • /
    • 2018
  • Radiation protection in the scrotum to reduce the risk of genetic effect in the future is very important. This study aimed to measure the scrotal dose outside the treatment fields by using the radio-photoluminescence glass dosimeter (RPLGD). The characteristics of RPLGD model GD-302M were studied. Scattered dose to scrotum was measured in one liposarcoma case with the prescribed dose of 60 Gy. RPLGDs were placed in three different locations: one RPLGD was positioned at the posterior area which closer to the scrotum, and the other two RPLGDs were placed between the penis and the scrotum. Three RPLGDs were employed in each location. The scattered doses were measured in every fraction during the whole course of treatment. The entire number of 100 RPLGDs showed the uniformity within ±2%. The signal from RPLGD demonstrated linear proportion to the radiation dose (r = 0.999). The relative energy response correction factor was 1.05. The average scrotal dose was 4.1 ± 0.9 cGy per fraction. The results presented a wide range since there was a high uncertainty during RPLGD placement. The total scrotal dose for the whole course of treatment was 101.9 cGy (1.7% of the prescribed dose). The RPLGD model GD-302M could be used to measure scattered dose after applying the relative energy correction factor.

Evaluation of Dose According to the Volume and Respiratory Range during SBRT in Lung Cancer (폐암의 정위적 체부 방사선치료 시 체적 설정과 호흡주기에 따른 선량평가)

  • Lee, Deuk-Hee;Park, Eun-Tae;Kim, Jung-Hoon;Kang, Se-Seik
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.391-397
    • /
    • 2016
  • Stereotactic body radiotherapy is effective technic in radiotherapy for low stage lung cancer. But lung cancer is affected by respiratory so accurately concentrate high dose to the target is very difficult. In this study, evaluated the target volume according to how to take the image. And evaluated the dose by photoluminescence glass dosimeter according to how to contour the volume and respiratory range. As a result, evaluated the 4D CT volume was 10.4 cm3 which was closest value of real size target. And in dose case is internal target volume dose was 10.82, 16.88, 21.90 Gy when prescribed dose was 10, 15, 20 Gy and it was the highest dose. Respiratory gated radiotherapy dose was more higher than internal target volume. But it made little difference by respiratory range. Therefore, when moving cancer treatment, acquiring image by 4D CT, contouring internal target volume and respiratory gated radiotherapy technic would be the best way.

Research about the absorbed dose with speculum material-related in Hysterosalpingography (자궁난관 조영술 검사 시 Speculum 재질에 따른 흡수선량의 변화에 관한 연구)

  • Kim, Yun-Min
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • The purpose of our study was to determine the entrance surface dose and absorbed dose in ovary when using the metal speculum and plastic speculum in hysterosalpingography respectively. The examinations was performed in anthropomorphic phantom into which calibrated photoluminescence glass dosimeter were placed on symphysis pubis level surface and ovary area. We checked average fluoroscopy time and spot expose times during the hysterosalpingography. It was average fluoroscopy time 58 sec, spot expose 5 times. We divided the subjects into two different groups to used metal and plastic speculum. We measured 10 times of absorbed dose in the same condition of the anthropomorphic phantom. We compared two groups adsorbed dose on ovary with speculum material-related. The entrance surface dose on of plastic Speculum using group was average 17.23 mGy, absorbed dose on ovary was average 3.51 mGy. The entrance surface dose on ovary of metal Speculum using group was average 19.95 mGy, absorbed dose on ovary was average 4.14 mGy. Plastic speculum using group shows a decrease absorbed dose(17.9%) as compared with metal speculum using group. The method of plastic speculum using in hysterosalpingography. might provide us with lower radiation dose, especially in patients with childbearing stage.

  • PDF

Effectiveness of Bismuth Shield to Reduce Eye Lens Radiation Dose Using the Photoluminescence Dosimetry in Computed Tomography (CT 검사에서 유리선량계를 이용한 수정체의 비스무트 차폐 효과)

  • Jung, Mi-Young;Kweon, Dae-Cheol;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.307-312
    • /
    • 2009
  • The purpose of our study was to determine the eyeradiation dose when performing routine multi-detector computed tomography (MDCT). We also evaluated dose reduction and the effect on image quality of using a bismuth eye shield when performing head MDCT. Examinations were performed with a 64MDCT scanner. To compare the shielded/unshielded lens dose, the examination was performed with and without bismuth shielding in anthropomorphic phantom. To determine the average lens radiation dose, we imaged an anthropomorphic phantom into which calibrated photoluminescence glass dosimeter (PLD) were placed to measure the dose to lens. The phantom was imaged using the same protocol. Radiation doses to the lens with and without the lensshielding were measured and compared using the Student t test. In the qualitative evaluation of the MDCT scans, all were considered to be of diagnostic quality. We did not see any differences in quality between the shielded and unshielded brain. The mean radiation doses to the eyewith the shield and to those without the shield were 21.54 versus 10.46 mGy, respectively. The lens shield enabled a 51.3% decrease in radiation dose to the lens. Bismuth in-plane shielding for routine eye and head MDCT decreased radiation dose to the lenswithout qualitative changes in image quality. The other radiosensitive superficial organs specifically must be protected with shielding.

  • PDF

Evaluation the absorbed dose in brain of dental radiography (치과방사선 검사에서 두부(brain)의 흡수선량 평가)

  • Jeon, Woon-Sun;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.343-349
    • /
    • 2011
  • This study was aimed to evaluate the absorbed dose in brain of dental radiography. For radiographic exposure, PLD(photoluminescence dosimetry) chips placed in Rando phantom to measurement the absorbed dose to pituitary gland, orbit, maxillary sinus and submandibular glands, thyroid gland, esophagus. Equipments were used Kodak 2200, Kodak 8000C dental radiographic systems and computed tomography(Lightspeed VCT). The absorbed doses were measured at the same exposure parameters and distance by the clinical factor(kV, mA, sec). The result were as follows ; The absorbed dose for intra-oral radiography were 0.02~2.47cGy, the greatest absorbed dose was 2.47cGy for thyroid gland in maxillary right molar projection. the lowest adsorbed dose was 0.02cGy for submandibular glands in lower anterior projection. The absorbed dose for extra-oral radiography were 0.36~3.44cGy of cephalometric method, 0.14~12.82cGy of panoramic method, 8.17~253.63cGy of computed tomography, the greatest adsorbed dose was 253.63cGy for submandibular glands in maxillary CT scan. the lowest adsorbed dose was 0.14cGy for orbit in panoramic method. As a result, extra-oral radiography was measured more than intra-oral radiography. In particular, method which used computed tomography was measured more than 100 times than intra-oral radiography highly. Therefore, you must show a guideline in extra-oral radiography and an effort to reduce absorbed dose is demanded.