• Title/Summary/Keyword: Photographic measuring

Search Result 21, Processing Time 0.023 seconds

The indirect measuring of two-dimensional photos using VENUS program (비너스 프로그램을 이용한 2차원 사진의 간접측정)

  • 정재은;남윤자;이준옥
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.6
    • /
    • pp.790-794
    • /
    • 2004
  • The study is about practical use of the computer program developed to obtain more efficient and accurate photographic measurement of body. Measuring measurements automatically using this program, the observational errors can be reduced considerably, so that the accuracy of photographic measurement are improved. The program has several functions as follow; First, free rotation of body by horizontal and perpendicular control of photo data. Second, recognition of body outline of photo data and automatic measuring of 45 basic items as well as freehand measuring of height, width, depth, angle. Third, obtaining database of photographic measurements of each subject without additional process such as data input.

Development of an Automatic Measuring Program for the Craniovertebral Angle Using Photographic Image (사진 영상을 이용한 머리척추각 자동 측정 프로그램 개발)

  • Soo-Young Ye;Jong-Soon Kim
    • PNF and Movement
    • /
    • v.22 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • Purpose: The prevalent use of mobile devices may contribute to musculoskeletal disorders, such as forward head posture (FHP), among users. The measurement of the craniovertebral angle (CVA) using photographic images is frequently employed in assessing FHP. Although manual CVA measurement using photographic images is reliable in clinical settings, computer programs or mobile applications to support tele-physical therapy are not yet fully developed. Therefore, in the current study, we propose an automatic method for extracting CVA from photographic images of FHP subjects to facilitate tele-physical therapy. Methods: To develop the automatic CVA measuring computer program, photographic images were obtained from 10 FHP participants. The location information obtained from the markers attached to the tragus and the spinous process of the seventh cervical vertebra were used as coordinates. Using these coordinates, straight line 1 was generated by connecting the seventh spinous process of the cervical vertebra and the tragus, while straight line 2 was drawn parallel to the coordinate obtained from the seventh spinous process of the cervical vertebra. The arc tangent function was used to calculate the angle between the two straight lines. The automatic CVA measurement computer program utilizing photographic images was developed using MATLAB (ver. 2016b). Results: The results showed that the automatic CVA measurement computer program demonstrated stable repeatability and high accuracy. Conclusion: The proposed approach was able to automatically estimate the CVA using photographic images. The developed computer program can potentially be used for easier and more reliable clinical assessment of FHP.

JPEG(Joint Photographic Experts Group)표준 영상 압축기법을 이용한 원격측정에 관한 연구

  • 김상철;왕지남
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1995.04a
    • /
    • pp.290-300
    • /
    • 1995
  • 본 연구는 JPEG(Joint Photographic Experts Group)표준 영상압축 방법을 이용한 원격측정 (remote measuring) 시스템을 다룬다. 많은 디지탈 비디오(digital video)이 응용중에서 주요 어려움은 디지탈 영상(digital image)을 직접적으로 표현하기 위해 필요한 방대한 데이터의 처리문제이다. 그리고 디지탈 영상의 직접적인 사용은 고수준 기억용량(high storage)과 전송비용(transmission costs)으로 인하여 응용상 여러가지 제약조건이 수반되었다. 이런 이유로 인하여 여러가지 영상압축 기법이 개발되어왔으며 본 연구는 정지영상(still pictures)에 대하여 JPEG 표준을 사용한 영상압축과 압축된 영상을 사용하여 실제 제조업의 공정검사에 응용하는 것이다. 수행도 평가척도로서 원래영상과 압축된 영상과의 압축비, 원래영상과 압축된 영상과의 픽셀(pixel)의 회색도 값(gray-level value)의 평균과 RMSE(root mean square error), 그리고 원래영상과 압축된 영상을 원거리(또는 근거리)로 전송하여 전송된 압축영상을 푼 후 두 지점간의 거리 측정에 따르는 실제거리와 측정거리에 대한 오차를 이용하였다.

  • PDF

A Study on the Rotating Displacement Measurement of Rigid Body by ESPI Method (ESPI법에 의한 강체 회전 변위 측정에 관한 연구)

  • 김경석;홍명석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.2
    • /
    • pp.125-133
    • /
    • 1993
  • Electronic Speckle Pattern Interferometry(ESPI) using a CW laser, a video system and image processor was applied to the rotating displacement of rigid body. ESPI require no special surface preparation or attachments and displacements between any two arbitrary points on the surface can be measured. The characteristic speckle pattern formed when imaging a scattering surface illuminated by laser light retains phase information, which can be used for interferometric measurement of surface displacement. The application of this principle to measuring in-plane displacement resolved in one direction is described, together with the novel use of television equipment to detect and process the information contained in the speckle pattern. This is faster, and more convenient and versatile than customary photographic methods.

  • PDF

Comparison of somatotypes from various classification methods - Between 18 and 24 years old Korean Women - (체형분류 방법에 따른 체형 유형 간 비교 - 18~24세 여성을 대상으로 -)

  • Lee, Jeong-Yim;Nam, Yun-Ja
    • Fashion & Textile Research Journal
    • /
    • v.6 no.2
    • /
    • pp.221-228
    • /
    • 2004
  • The purpose of this study was to compare somatotypes from various classification methods, to analyze the interrelation among each somatotype or each high frequency type, and to suggest the basis to interpret body size and shape more accurately. As a sample, the subjects were 97 Korean females between 18 and 24 years old. They were measured both anthropometric and photographic measuring in November, 1999. Their somatotypes were classified by three kinds of classification methods. The first method was based on the lateral view of body, the second involved Factor and Cluster analysis with the photographic measurements of anterior and lateral body, and the third involved Factor and Cluster analysis with the anthropometric measurements of whole body. The upper body was classified into three types, and the lower body was classified into 6 types from the lateral view of body. The bend-forward/q-2 was found to be the 'High-frequency type from the lateral view of body', and the Straight/n-1 was found to be the 'Straight type from the lateral view of body'. From the classification by the analysis of photographic measurements, the anterior body was classified into three types, the lateral was classified into 4 types. The X/${\varepsilon}$ type was found to be the 'High-frequency type from the analysis of photographic measurements of anterior and lateral body'. From the classification by the analysis of anthropometric measurements, the whole body was classified into three types. The i type was found to be the 'High-frequency type from the analysis of anthropometric measurements of whole body'. The significant interrelation was certified among some somatotypes or some High-frequency types. We found that both the view of body and the statistical analysis would make the clear definition of each somatotype possible. In order to certify the representativeness of High-frequency type, further analysis would be required of subjects who were in the High-frequency type and their body parts were in the High-frequency range.

A Study on the Plan Photogrammetry for Clothing Design (피복구성학적 인체계측방법에 관한 연구 - 평면사진계측방법을 중심으로 -)

  • 박찬미;서미아
    • The Research Journal of the Costume Culture
    • /
    • v.5 no.1
    • /
    • pp.151-164
    • /
    • 1997
  • This study pursues the problems of plan photogrammetry which is widely used in somatotyping at present, and find out a method which can improve accuracy of measurement on the basis of principles and mechanisms of photography-the basic foundation of the photographic analysis methods. As a result, this study proposes a new method which is based on the reference point method and perspective coordinate system. And the test measurement was operated to compare the measurement accuracy of the proposed method and the method based on reference grid screen method and perpendicular coordinate system which is commonly used at present. The result of this test measurement showed that the proposed method has higher accuracy. Two reasons can be pointed out for the improvement of measuring accuracy. The first reason is that the proposed perspective coordinate system reduces the perspective distortion of photography. And second reason is that measuring points can be closely placed to the scale and coordinate reference plan of measurement by the proposed reference point method which make possible to place measuring object (or person) at the center of scale and coordinate reference plan by utilizing reference points of measurement in the three dimensional space not on screen.

  • PDF

Chair side measuring instrument for quantification of the extent of a transverse maxillary occlusal plane cant

  • Naini, Farhad B.;Messiha, Ashraf;Gill, Daljit S.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.21.1-21.3
    • /
    • 2019
  • Background: Treatment planning the correction of a transverse maxillary occlusal plane cant often involves a degree of qualitative "eyeballing", with the attendant possibility of error in the estimated judgement. A simple chair side technique permits quantification of the extent of asymmetry and thereby quantitative measurements for the correction of the occlusal plane cant. Methods: A measuring instrument may be constructed by soldering the edge of a stainless steel dental ruler at 90° to the flat surface of a similar ruler. With the patient either standing in natural head position, or alternatively seated upright in the dental chair, and a dental photographic retractor in situ, the flat under-surface of the horizontal part of this measuring instrument is placed on a unilateral segment of a bilateral structure, e.g. the higher maxillary canine orthodontic bracket hook. The vertical ruler is held next to the contralateral canine tooth, and the vertical distance measured directly from the canine bracket to the flat under-surface of the horizontal part of the measuring instrument. Results: This vertical distance quantifies the overall extent of movement required to level the maxillary occlusal plane. Conclusions: This measuring instrument and simple chair side technique helps to quantify the overall extent of surgical levelling required and may be a useful additional technique in our clinical diagnostic armamentarium.

On Automatic Apparatus for Cryoscopy and Improvement in Experimental Method (Cryoscopy 裝置와 方法의 改良에 關한 硏究)

  • Shin, Yun-Kyong;Lee, Joon
    • Journal of the Korean Chemical Society
    • /
    • v.18 no.2
    • /
    • pp.143-149
    • /
    • 1974
  • The traditional cryoscopic measurement had performed by inconvenient manual operation which accompanies various unavoidable errors. For example, the irregularity of hand stirring, difference of visual angle in reading Beckmann thermometer and furthermore, its large heat capacity acts as the decreasing effect of the sensitivity. In these studies, the author devised new automatically measuring cryoscopic apparatus with temperature recording system in which temperature variation is changed to electric current. The light beam from the galvanometer is absorbed by the photographic paper on the rotating cylinder. On the other hand, the use of sodium sulfate decahydrate in cryoscopy causes considerable error, because small crystal particles adhere on the upper wall of the measuring tube. As an improvement, anhydrous sodium sulfate is used and then the desired amount of water is added.

  • PDF

The plastic design of dart location from the viewpoint of visual-spatial division (시각적 공간분할로 본 Dart 위치의 조형적 설계)

  • 정옥임
    • Journal of the Ergonomics Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.33-40
    • /
    • 1987
  • To study the body trunk basic to Clothing construction, and study the peculiarities of visual spatial division, necessary items are measured indirectly from 216 unmarried women from 19 to 24 years old by a photographic net-work method. In so doing, the problem of Fashion Design in establishing the location of Darts for Basic Dress is not considered. The following results are obtained. 1) Indirect measuring method, is obtained approximate to actual size, with an error of .+-. 2.8cm. 2) In the modeling plan of Dart location viewed from the visual-spatial division in Basic Dress, it is concluded that Darts are to be placed at the point of 1/3k+1/5k form the waist. From the aesthetic point of wiew, it is more appealling for darts to be placed at the point of 6cm .+-. 0.6cm right or left of center. 3) From direct measurement dart location can be set based on bust point width, and from indirect measurement, dart location can be set based on waist width.

  • PDF

Spray droplet size measurement using image processing technique (영상처리기법을 이용한 분무액적 크기의 측정)

  • 김인구;이상용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.5
    • /
    • pp.1121-1129
    • /
    • 1988
  • An economic and efficient system for measuring drop sizes was developed. Pattern recognition technique was used with conventional oil-bath sampling and photographic method. The system was designed to measure and count relatively large number of drops in a very short time, and also to filter out abnormal images such as drops in contact or overlap as well as odd-shaped foreign materials. In this measuring system, most important error originates from the process of converting the original image to the binary image. If the photograph contains a large number of spray drops, the relative size of the pixel to the drops is not infinitesimally small; thus the proper choice of threshold level to convert the original image to the binary image becomes very important. In present case, most of the images lay in one of the two separate bands of brightness level and the arithmetic mean of the most popular brightness levels from each band was chosen as the threshold level. Present image processing system reduces the subjective error by the observers in counting and measuring drops and turns out to be substantially effective. The processing time can be further reduced by improving the hardware system concerned with the digital image coding.