임플랜트 고정체의 형태에 따른 광탄성 응력분석 (PHOTOELASTIC STRESS ANALYSIS OF IMPLANTS ACCORDING TO FIXTURE DESIGN)

  • 문소희;김난영;김유리;조혜원
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.51-62
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate the pattern and the magnitude of stress distribution in the supporting tissues surrounding three different types of implants(ITI, 3i. and Bicon implant system) Material and method: Photoelastic models were made with PL-2 resin(Measurements Group, Raleigh, USA) and three implants of each kind were placed in the mandibular posterior edentulous area distal to the canine. For non-splinted restorations, individual crowns were fabricated on three titanium abutments. For splinted restorations, 3-unit axed partial dentures were fabricated. Photoelastic stress analyses were carried out to measure the fringe order around the implant supporting structure under simulated loaded conditions(15 lb. 30 lb). Conclusion: The results were as follows; 1 Regardless of the implant design, stresses were increased in the apex region of loaded implant when non-splinted restorations were loaded. While relatively even stress distribution occurred with splinted restorations. Splinting was effective in the second implant. 2. Strain around Bicon implant were lower than those of other implants, which confirmed the splinting effect. The higher the load, the more the stress occurred in supporting tissue, which was most obvious in the Bicon system. 3. Stress distribution in the supporting tissue was favorable in the ITI system. while the other side of 3i system tended to concentrate the stress in some parts.

동적 광탄성실험에 의한 응력이완 노치부근에서의 접촉특이응력 해석 (2) (Analysis of Contact Singular Stresses with Relief Notch by Using Dynamic Photoelasticity(II))

  • 이억섭;황시원;나경찬
    • 대한기계학회논문집A
    • /
    • 제20권7호
    • /
    • pp.2097-2107
    • /
    • 1996
  • The dynamic photoelastic technique had been utilized to investigate the possibillity of relieving the large local singular stresses induced at the corner of a right- angle- indenter. The indenter compressed a semi-infinite body dynamically with an impact load applied on the top of the indenter. The effects of the geometric changes of the indenter in terms of the diameter (d) and the location (1) of the stress relieving notch on the behavior of the dynamic contact stresses were investigated. The influence of stress relieving notches positioned along the edge of the semi-infinite body on the dynamic contact stresses were also studied by changing the diameter (D) and the location (L) of the notch. A multi-speak-high speed camera with twelve sparks were used to take photographs of full field dynamic isochromatic fringe patterns. The contact singular stresses were found to be released significantly by the stress relief notches both along the indenter and the edge of the semi-infinite body. The optimal position and geometry of the stress relieving notches were obtained with the aid of limited experimental results.

치과 임플랜트 보철 수복시 각 상부구조의 형태에 따라 발생되는 응력의 광탄성학적 분석 (PHOTOELASTIC ANALYSIS OF STRESSES INDUCED BY VARIOUS SUPERSTRUCTURES ON THE ENDOSTEAL IMPLANT)

  • 최영희;조인호
    • 대한치과보철학회지
    • /
    • 제31권4호
    • /
    • pp.679-686
    • /
    • 1993
  • The osseointegrated implant conducts the stress directly to the bone due to lack of cushoning effect of periodontal ligament. So, the design and material quality of superstructure plays an important role in resolution and diffusion of stress. Recently, the various superstructures have been developed to improve esthetics and resolve various complicated conditions. The purpose of this study was to evaluate the stress induced by various system on the osseointegrated implant using UCLA abutment, EsthetiCone abutment, Anatomic abutment as well as Branemark conventional abutment. The stress distribution was evaluated by the photoelastic method which can simultaneously observe all around stress distribution. The superstructures embedded in epoxy resin specimen were loaded at various angle with a force of 15Kg to analyse the stress distribution of the fixture. The results of this study were obtained as follows : 1. Under vertical loading, the large and broad stress was distributed below the fixture in all systems. 2. The fringe order of the stress was increased in proportion to tillting the specimen. The largest stress was shown in 25 angled degree tilting case. 3. The Branemark conventional abutment showed the lowest value, and EsthetiCone abutment, Anatomic abutment and UCLA abutment showed the stress value in accending order.

  • PDF

切削加工 의 光彈性的 現象 에 관한 硏究( I ) (A Study on Photoelastic Fringe Patterns in Cutting Proces(I))

  • 김정두;이용성
    • 대한기계학회논문집
    • /
    • 제7권2호
    • /
    • pp.161-167
    • /
    • 1983
  • In this study the phenomenon of cutting stress which arises on cutting tools and work pieces in cutting process is investigated by rake angle of cutting tools and feed for this measurement, P$_{s}$-1 (high modulus, photolastic Inc.) was used as a cutting tool, P$_{s}$-3 (medium modulus, photolastic Inc.) was used as work piece and reduction apparatus was attached to the head stock, and orthogonal cutting was adapted as a cutting method and transparent glass was used to block the strain in the orientation of thickness. The followings are the results of this study. (1) Photoelastic experimental equipments have made it possible to make dynamic measurement and analyze stress distribution in cutting tool and work piece surface which has hitherto been conducted only in static measurement and analyzing method. (2) The maximum stress arising at tools and work pieces in cutting process is on the tool edge tip, and the maximum stress arising on the tip of cutting tools is equal to that on the contacting area of work pieces in values. (3) The distributions of maximum shear stress on certain parts of the cutting tools and work pieces are as follows; for cutting tools, .alpha.=12.deg., .alpha.=0.deg., .alpha.=-12.deg. in order, and for work pieces, .alpha.=-12.deg., .alpha.=0.deg., .alpha.=12.deg. in opposite order.der.

직접유지장치 설계 변화에 따른 하악 후방연장 국소의치 지지조직의 광탄성 응력분석 (PHOTOELASTIC STRESS ANALYSIS ON THE SUPPORTING TISSUE OF MANDIBULAR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE WITH VARIOUS DESIGN OF DIRECT RETAINERS)

  • 이창호;김광남;장익태
    • 대한치과보철학회지
    • /
    • 제30권2호
    • /
    • pp.203-224
    • /
    • 1992
  • The purpose of this study was to evaluate the stress distribution developed in supporting structures by distal extension removable partial denture with 4-types of direct retainer. The direct retainers examined were Akers clasp, RPI clasp, RPA clasp and RPL clasp in bilateral & unilateral free end case. 3-dimensional photoelastic stress analysis was used to record the isochromatic fringe patterns and to calculate the compressive stress at measuring points. The results were as follows. 1. In bilateral free end case, RPI clasp exhibited the similar stress distribution on distal and mesial alveolar crest but Akers clasp exhibited higher stress concentration on distal alveolar crest than mesial alveolar crest. 2. In bilateral free end case, RPA clasp and RPL clasp exhibited the similar stress distribution on distal and mesial alveolar crest and RPL clasp exhibited higher stress concentration on buccal alveolar crest than lingual alveolar crest. 3. Akers clasp produced high stress concentration on residual alveolar ridge distally, but RPI clasp, RPA clasp and RPL clasp produced even stress distribution on residual alveolar ridge. 4. Removable partial denture in unilateral free end case exerted higher stress on abutment tooth root apex than bilateral distal extension removable partial denture.

  • PDF

압축하중시 RPI clasp의 3가지 다른 proximal plate 형태에 따른 지대치 주위조직의 광탄성 응력 분석 (Photoelastic Stress Analysis of the Abutment Surrounding Tissue According to Shape of the Proximal Plate of the RPI Clasp)

  • 최정수;김부섭
    • 대한치과기공학회지
    • /
    • 제34권4호
    • /
    • pp.473-482
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the stress distribution of the surrounding tissues according to 3 proximal plate types of the RPI clasp. Methods: The removeable partial denture which mandibular right and left second premolars and mandibular molars were lost was attached to a three dimensional photo elastic epoxy resin model. Then 120N of vertical load was applied. After 3-dimensional photoelastic stress analysis was used to record the isochromatic fringe patterns. Results: Kratochvil type guiding plane exhibited little uniform stress distribution on load center and alveolar ridge, but higher stress concentration on buccal surface of second premolar. Krol type guiding plane exhibited the stress concentration on the front of load center and relatively higher stress concentration on buccal surface of first premolar. However, this type had no effect on canine. Researcher type guiding plane showed the stress concentration on second premolar and molar, but the little stress distribution on first premolar. Conclusion: In all types, excessive stress concentration was appeared and three types were not significant different.

정밀 부착형 유지장치에 따른 양측성 유리단 국소의치의 광탄성 응력분석 (A Photoelastic Stress Analysis of Bilateral Distal Extension Removable Partial Denture with Attachment Retainers)

  • 조혜원;장익태
    • 대한치과보철학회지
    • /
    • 제23권1호
    • /
    • pp.97-112
    • /
    • 1985
  • The purpose of this study was to evaluate the stress patterns developed in supporting structures by removable partial denture with attachment retainers. The attachments tested were Dalbo(miniature) attachment, resilient Ceka attachment, rigid Ceka attachment, precision and sleeve attachment, and R.P.I. clasp as a contrast. 3-dimensional photoelastic stress analysis was used to record the isochromatic and isoclinic fringe patterns and to calculate principal stress components at measuring points. The results showed that: 1. The maximum compressive stress on residual ridge was produced under the loading point with Dalbo and resilient Ceka attachment, distal to the loading point with rigid Ceka and precision and sleeve attachment, and mesial to the loading point with R.P.I. clasp. 2. The Dalbo attachment produced the most stress on residual ridge, and the least stress on abutment teeth. and resilient Ceka attachment showed favorable stress distribution. 3. Rigid Ceka attachment produced higher compressive stress on buccal. alveolar crest, and precision and sleeve attachment produced higher compressive stress on distal alvelolar crest and mesial surface of the root apex in abutment teeth. 4. R.P.I. clasp produced higher compressive stress on mesial alveolar crest.

  • PDF

광탄성 응력측정을 위한 투과형 원형편광기 제작 및 시험 (Construction and Calibration Test of a Transmission-type Circular Polariscope for Photoelastic Stress Measurement)

  • 백태현;김명수
    • 한국정밀공학회지
    • /
    • 제21권3호
    • /
    • pp.38-43
    • /
    • 2004
  • This paper describes the construction of a circular polariscope. Generally, a circular polariscope contains four optical elements and a light source. The first element following the light source is called the linear polarizer. It converts the ordinary light into plane-polarized light. The second element is a quarter wave plate which converts the plane-polarized light into circularly polarized light. Following the quarter wave plate, a specimen made of transparent photoelastic material is located in a loading device. The second quarter wave plate is set and the last element is the analyzer. These polarizing elements, two quarter wave plates and two linear polarizing filters, were purchased from the USA. Frames and other structures for holding polarizing filters were machined and assembled to be rotated. Light box, which includes four incandescent lamps and two sodium-vapor lamps, was made. In order to proof the function of the newly built polariscope, Tardy compensation test was applied to a rectangular shaped specimen made of poly-carbonate material (PSM 1). The error of the fringe constant, which was measured by the newly built polariscope, was within 4.4 percent compared to the standard value of this material. It is possible to make a good quality of polariscope if accurate polarizing filters will be used.

광탄성법을 이용한 인장판의 경사균열 응력확대계수 측정 (Stress Intensity Factor Measurement of Inclined Crack in Tensile Plates by Use of Photoelasticity)

  • 백태현;이춘태;김영철
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제5권2호
    • /
    • pp.215-222
    • /
    • 2015
  • 본 논문에서는 중앙에 경사 균열이 있는 시편을 원형편광기에 설치하여 인장하중을 가한 후 나타나는 등색프린지로부터 디지털 영상처리기법을 사용하여 광탄성 프린지를 2배로 증식하여 세선처리한 후, 이로부터 응력확대계수를 측정하였다. 경사균열 시편으로부터 광탄성 법을 이용하여 응력확대계수를 구한 후 이론식으로 계산한 값과 비교하였다. 실험 결과는 이론값에 근접하였으며 광탄성 법으로 응력확대계수를 정밀하게 측정할 수 있는 가능성을 제시하였다.

목형용(木型用) 춘양목(春陽木)의 절삭가공(切削加工) 특성(特性)에 관(關)한 연구(硏究)(제1보(第1報)) - 절삭중(切削中) 공구면(工具面)의 응력분포에 미치는 접촉(接觸)칩의 영향(影響) - (Study on the Machinability of Pinus densiflora at Chunyang District for Wood Patterns - Effect of Chip-Tool Contact Stress Distribution in Workpiece During of Wood Machining -)

  • 김정두
    • Journal of the Korean Wood Science and Technology
    • /
    • 제16권4호
    • /
    • pp.54-60
    • /
    • 1988
  • Machinabilities means inherent properties of pinus densiflora at Chunyang district to be CNC machined easily or not, and processing abilities of the tool and machine together. This explanation signifies that machinabilities have two phases of signification, depended on considering and stress either materials or tools preferentially. This paper discuss machinabilities, the following items are usually employed as the indices of stress distribution at the cutting tool rake face. The stress distributions on the chip - tool contact surface at the early stage of the chip forming and under the stage of fringe pattern in wood cutting were analyzed the photoelastic method. The tool used in the present experiment was the special cutting tool H.S.S. one made in laboratory. And isochromatic fringe pattern and isolinic line of work piece by chip-behavior during the cutting operation were photographed with the feed camera continuously. The effects on the stress, distribution on the rake face of the epoxy tool and the strain distribution in the work piece of wood plate by chip behavior are cleared in pre cent experiment.

  • PDF