• Title/Summary/Keyword: Photoelastic

Search Result 197, Processing Time 0.021 seconds

Measurement of Stress and Displacement Fields in Particle Assembly subjected to Shallow Foundation Loading via Photoelasticity Technique (광탄성 기법을 이용한 얕은 기초 하중을 받는 입상체의 응력 및 변위장 측정)

  • Byeon, Bo-Hyeon;Jung, Young-Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1947-1955
    • /
    • 2013
  • The purpose of this paper is to present an photoelasticity technique for measuring the displacement and stress distribution in particle assembly subjected to shallow foundation loading. Photoelastic measurement technique was employed to visualize the force transmission of a particle assembly. A model assembly bounded by a steel frame was built by stacking bi-dimensional circular particles made of polycarbonate elastomer. Each particle was coated by a thin photoelastic sheet so that the force transmission represented by bright light stripes can be visualized. In a contacted particle, both magnitude and orientation of principal stress difference can also be measured via the photoelasticity technique. The different distributions of the contact stresses at the initial loading and near the failure were quantitatively compared. The photoelastic patterns and displacement fields observed in the pre-failure state disappears immediately after the buckling of confined force chains.

The simple measurement of physical properties and stress fringe value for photo-elastic orthotropic material (광탄성 직교이방성체의 물성치와 응력 프린지치 간이 측정법)

  • 황재석;이광호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.23-36
    • /
    • 1990
  • The various composite materials have been developed with the development of high strength material and the increasement of composite material usage. Therefore many researchers have studied about the stress analysis and the fracture mechanics for composite materials through the experiment or the theory. Among the experimental methods, the photoelastic experiments have been used for the stress analysis of the isotropic structures or the anisotropic structures. To analyze the stresses in the orthotropic material with photoelastic experiment, the basic physical properties ( $E_{L}$, $E_{T}$, $G_{LT}$ , .nu.$_{LT}$ ) and the basic stress fringe values ( $f_{L}$, $f_{T}$, $f_{LT}$ )are needed, therefore the relationships between the basic physical properties and the stress fringe values were derived in this paper. When the stress fringe value is very large, it was assured by the experiment that the relationships are established both in the room temperature and in the high temperature (T = 130.deg. C). Therefore the basic physical properties can be obtained from the relationships by measuring stress fringe values instead of measuring the basic physical properties.rties.

A PHOTOELASTIC STRESS ANALYSIS OF FIXED PARTIAL DENTURES WITH BICON IMPLANTS ON MANDIBULAR POSTERIOR AREA (하악구치부에서 Bicon 임플란트에 의해 지지되는 고정성 국소의치의 광탄성 응력분석)

  • Kang, Jong-Un;Kim, Nan-Young;Kim, Yu-Lee;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.4
    • /
    • pp.412-424
    • /
    • 2004
  • Statement of problem: Several prosthetic options are available for the restoration of multiple adjacent implants. A passively fitting prosthesis has been considered a prerequisite for the success and maintenance of osseointegration. Passivity is a particular concern with multiple implants because of documented inaccuracies in the casting and soldering process. One way to avoid this problem is to restore the implants individually, however, the restorations of individual adjacent impants requires careful adjustment of interproximal contacts. Purpose: The purpose of this study was to compare the stress distribution pattern and amount surrounding Bicon implants with individual crowns and splinted restorations. Material and method: A photoelastic model of a human partially edentulous left mandible with 3 Bicon implants($4{\times}11mm$) was fabricated. For non-splinted restorations, individual crowns were fabricated on 3 abutments ($4{\times}0.65mm,\;0^{\circ}$, 2.0 mm post, Bicon Inc., Boston, USA) After the units were cemented, 4 levels of interproximal contact tightness were evaluated: open, ideal ($8{\mu}m$ shim stock drags without tearing), medium($40{\mu}m)$), and heavy($80{\mu}m$). Splinted 3-unit fixed partial dentures were fabricated and cemented to the model. Changes in stress distribution under simulated non-loaded and loaded conditions(7.5, 15, 30 lb) were analyzed with a circular polaricope. Results: 1. Stresses were distributed around the entire body of fin in Bicon implants. 2. Splinted restorations were useful for distribution of stress around implants especially with higher loads. 3. By increasing the contact tightness between the individually restored three implants, the stress increased in the coronal portion of implants. Conclusions: Ideal adjustment of the contact tightness was important to reduce the stresses around individually restored Bicon implants.

The Stress Distribution Property on the Customized Ankle Foot Orthoses During the Gait Period (보행주기에 따른 맞춤형 단하지보조기의 응력분포 특성)

  • Choi, Young-Chul;Rhee, Kun-Min;Choi, Hwa-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.165-175
    • /
    • 2008
  • An ankle-foot orthosis(AFO) is a brace for persons with gait disabilities to support or replace the function of ankle joint. Ankle-foot orthoses(AFO's) are usually prescribed to alleviate the drop-foot by constraining the excessive plantar flexion. The shape and the strength of the AFO are often based on 'trial and error' due to a lack of knowledge of the stress distribution in the AFO. In this study, an improved stress-freezing method was proposed to measure the stress distribution characteristics in the AFO. As a result, a photoelastic material with low freezing temperature was developed to measure the stresses under a person's direct contact loading condition. The three-dimensional stress-1rozen photoelastic models of AFO's for five stages of stance phase such as heel contact, foot flat, mid stance, heel off, and toe off were produced. The results of photoelastic analysis revealed that the stresses developed in the AFO were varied considerably from tensile to compressive or vice versa, during walking. At the posterior part of ankle joint in the AFO, the maximum compressive stress of 1.81MPa was observed in the mid stance, and the maximum tensile stress of 0.74MPa was observed during heel contact. The overall stress levels in the AFO's were low in the toe off phase. The results suggested that the posterior part of ankle joint might be the most fragile part in the AFO.

Fringe Analysis around an Inclined Crack Tip of Finite-Width Plate under Tensile Load by Photoelastic Phase-Shifting Method (광탄성 위상이동법을 이용한 인장판 경사균열 선단주위의 프린지 해석)

  • Li, Weizheng;Baek, Tae-Hyun;Hong, Dong-Pyo;Lee, Byung-Hee;Seo, Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.27-33
    • /
    • 2012
  • Photoelasticity is a technique of experimental methods and has been widely used in various domains of engineering to determine the stress distribution of structures. Without complicated mathematical formulation, this technique can conveniently provide a fairly accurate whole-field stress analysis for a mechanical structure. Here, stress distribution around an inclined crack tip of finite-width plate is studied by 8-step phase-shifting method. This method is a kind of photoelastic phase-shifting techniques and can be used for the determination of the phase values of isochromatics and isoclinics. According to stress-optic law, the stress distribution could be obtained from fringe patterns. The results obtained by polariscope arrangement combined with 8-step method and ABAQUS FEM simulations are compared with each other. Good agreement between them shows that 8-step phase-shifting method is reliable and can be used for determination of stress by experiment.

Measurement of Isochromatic Fringe Distribution of a TV Glass Panel by Use of Photoelastic 4-step Phase Shifting Method (광탄성 4단계 위상이동법을 이용한 TV유리패널의 등색프린지 분포측정)

  • Baek, Tae-Hyun;Kim, Myung-Soo;Cho, Seong-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • This paper presents the experimental results measured by photoelastic 4-step phase shifting method for the isochromatic fringe distribution in a TV glass panel. In the conventional photoelastic method, the isochromatic fringe orders are measured manually point by point. The 4-step phase shifting method uses four images obtained from a circular polariscope by rotating the analyzer to $0^{\circ},\;45^{\circ},\;90^{\circ}$, and $135^{\circ}$. In order to use the 4-step phase shifting method, the elements of a polariscope should be aligned to isoclinic direction at a point and/or along a line where isochromatic fringe distribution is measured. Experimental results obtained from the 4-step phase shifting method are compared with those measured by the Senarmont compensation method. Both results are well agreed. Then, isochromatic fringe distributions in the TV glass panel that is heat-treated before and after are compared. Maximum and minimum isochromatic fringe orders in the TV glass panel with before- and after-heat treatment are changed approximately two times.

A PHOTOELASTIC STUDY ON EFFECTS OF BONE REDUCTION FORCEPS ON MANDIBULAR FRACTURE REDUCTION (골절정복겸자가 하악골 골절정복에 미치는 효과에 관한 광탄성 연구)

  • Park, Jin-Hyoung;Choi, Byung-Ho;Yoo, Tae-Min;Huh, Jin-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.6
    • /
    • pp.464-471
    • /
    • 2002
  • The purpose of this study was to evaluate the stress patterns within fractured mandibles generated by reduction forceps and to determine the optimal position of the reduction forcep. Twenty-seven mandibular models were fabricated using a photoelastic resin. Each of the three sets of mandible models prepared was osteotomized according to one of three different fracture types(symphysis, parasymphysis and body fractures). After reducing the cut segments, a reduction forcep was placed into different engagement holes to compress the segments. Photoelastic stress analysis was used to visualize the stress patterns within the fractured mandiblular models generated by the reduction forcep. In the case of symphysis or parasymphysis fractures, an optimum distribution of stress over the fracture site was achieved when placing the reduction forcep more than 12.5mm on either side of the fracture line between the midway level bisecting the mandible and 5mm below the level. In the case of body fractures, optimum stress distribution was achieved when the reduction forcep was placed more than 15mm from the fracture line on the midway level. In conclusion, a correct use of reduction forceps helps to provide a precise threedimensional reduction for mandibular fractures.

Analysis of Stress Distribution of a Curved Beam Using Photoelasticity (광탄성법을 이용한 곡선보 평판의 응력분포 해석)

  • Baek, Tae-Hyun;Kim, Myung-Soo;Kim, Soo-Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.3
    • /
    • pp.200-206
    • /
    • 1999
  • This paper describes the stress analysis of a curved beam by using photoelasticity. In order to measure accurate isochromatic fringe orders at certain locations. fringes are doubled and sharpened by digital image processing. After fringe multiplication and sharpening. fringe orders can be read as a quarter order interval (N=0, 1/4, 2/4, 3/4,...). The results obtained from photoelastic experiment are compared with those calculated by using theory. Two results are agreed well even though there are some scatter bands with maximum 8 percent for the results of photoelastic measurements and theoretical calculation. Difference may be occurred due to the slight misalignment of the direction to which axial load is applied in photoelastic experiment. It is confirmed that accurate measurement of stress distribution can be possible by using the techniques of fringe multiplication and sharpening in photoelasticity.

  • PDF

Photoelastic stress analysis of the mandibular unilateral free-end removable partial dentures according to the design (하악 편측 유리단 가철성 국소의치의 설계에 따른 광탄성 응력 분석)

  • Park, Cheol-Woo;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.206-214
    • /
    • 2009
  • Statement of problem: There are common clinical cases in which the mandibular first and second molars are missing unilaterally. Purpose: This study was designed to compare and evaluate the magnitude and distribution of stress produced by four kinds of mandibular unilateral free-end removable partial dentures that could be applied clinically in Kennedy class II cases. Material and methods: Four unilateral free-end removable partial dentures using clasp, Konus crown, resilient attachment, and flexible resin were fabricated on the photoelastic models of the Kennedy class II cases. The vertical load of 6㎏ was applied on the central fossa of the first molar of every removable partial denture in the stress freezing furnace and the photoelastic models were frozen according to the stress freezing cycle. After these models were sliced mesio-distally to a thickness of 6mm, the photoelastic isochromatic white and black lines of the sliced specimens were examined with the transparent photoelastic experiment device and photographs were taken with a digital camera. The fringe order numbers at eight measuring points in the photograph were measured with the naked eye. Results: The maximum fringe order number of each sliced specimen and the fringe order number at the residual ridge just below the loading point were in the decreasing order of the unilateral removable partial dentures using flexible resin followed by clasp, resilient attachment, and Konus crown. The fringe order number at the root apex of the second premolar was in the decreasing order of the unilateral removable partial dentures using clasp followed by flexible resin, Konus crown, and resilient attachment. Conclusion: The removable partial denture using Konus crown showed the most equalized stress distribution to the supporting alveolar bone of abutment teeth and residual ridge under the vertical loads. The removable partial denture using flexible resin can be applied to the case that has a better state of residual ridge than abutment teeth.

A photoelastic study of the stress distribution on canine retraction by segmented TMA T-loop spring (Segmented TMA T-loop spring에 의한 견치 후방이동시의 응력분포에 관한 광탄성법적 분석)

  • Yoon, Young-Jooh;Kim, Kwang-Won;Yu, Pil-Sik
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.199-207
    • /
    • 2001
  • The segmented TMA T-loop spring, used for reciprocal space closure and described by Burstone, was used to achievebodily movement of canine. Photoelastic analysis is a technique for the transformation of internal stress into visible light patterns. The two-dimensional photoelastic stress analysis was performed, and stress distribution was recorded by photography. The purpose of this study was to visualize photoelastically the distribution of forces transmitted to the alveolus and surrounding structures using new segmented TMA T-loop spring for canine retraction. The results were as follows: 1. Decreased activation produced decreased stress of upper 1st. premolar extraction site and increased intrusive stress of upper 1st. molar, regardless of T-loop position. 2. At 5mm activation, More posterior positioning of T-loop Produced an increased stress in upper 1st. premolar extraction site. 3. At 3mm activation, More posterior positioning of T-loop produced an increased stress in upper 1st. premolar extraction site and mesial lower half of upper 1st. molar mesio-buccal root. 4. At 1mm activation, More anterior positioning of T-loop produced an increased stress in upper mesial and blew apex area of upper canine root. 5. 0.25 B/L ratio and 3mm activation produced bodily movement of canine. To summarize, desired tooth movement and anchorage requirement is possible by altering the activation and mesio-distal position of the T-loop spring.

  • PDF