• Title/Summary/Keyword: Photodiode

Search Result 532, Processing Time 0.029 seconds

Signal and Noise Analysis of Indirect-Conversion Digital Radiography Detectors Using Linear-systems Transfer Theory (선형시스템 전달이론을 이용한 간접변환방식 디지털 래디오그라피 디텍터의 신호 및 잡음 분석)

  • Yun, Seung-Man;Lim, Chang-Hwy;Han, Jong-Chul;Joe, Ok-La;Kim, Jung-Min;Kim, Ho-Kyung
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.261-273
    • /
    • 2010
  • For the use of Indirect-conversion CMOS (complementary metal-oxide-semiconductor) detectors for digital x-ray radiography and their better designs, we have theoretically evaluated the spatial-frequency-dependent detective quantum efficiency (DQE) using the cascaded linear-systems transfer theory. In order to validate the developed model, the DQE was experimentally determined by the measured modulation-transfer function (MTF) and noise-power spectrum, and the estimated incident x-ray fluence under the mammography beam quality of W/Al. From the comparison between the theoretical and experimental DQEs, the overall tendencies were well agreed. Based on the developed model, we have investigated the DQEs values with respect to various design parameters of the CMOS x-ray detector such as phosphor quantum efficiency, Swank noise, photodiode quantum efficiency and the MTF of various scintillator screens. This theoretical approach is very useful tool for the understanding of the developed imaging systems as well as helpful for the better design or optimization for new development.

Correlation of Lignan Contents with Protein and Oil Contents in the Seeds of Sesamum indicum L.

  • Lee, Jin-Hwan;Baek, In-Youl;Ko, Jong-Min;Shim, Kang-Bo;Kang, Nam-Suk;Kim, Hyun-Tae;Kang, Churl-Hwan;Park, Keum-Yong;Park, Ki-Hun;Ha, Tae-Joung
    • Journal of Applied Biological Chemistry
    • /
    • v.51 no.1
    • /
    • pp.20-27
    • /
    • 2008
  • The contents of lignan, protein, and oil of nine Sesamum indicum cultivars were analyzed. To determine the lignan contents, sesamin 1 and sesamolin 2 were isolated from the ethylacetate extracts of the Suwon cultivar, and the structures were fully characterized by spectral and physical methods. The seeds of nine cultivars were screened for two lignans, which were determined by HPLC using a $C_{18}$ reversed phase column coupled with a photodiode array detector. Suwon cultivar showed the highest concentration (1: $6.24{\pm}0.04$ and 2: $3.58{\pm}0.01\;mg/g$), whereas Soonheuk displayed the lowest (1: $0.91{\pm}0.01$ and 2: $0.73{\pm}0.01\;mg/g$). The average content ratio of sesamin 1 (3.64 mg/g) was significantly higher than that of sesamolin 2 (2.57 mg/g). The protein content ranged from $21.52{\pm}0.35$ to $31.22{\pm}0.25%$, Suwon containing the highest level and Soonheuk had the lowest. Kwangbaek showed the highest oil level ($49.84{\pm}0.40%$), while Soonheuk exhibited the lowest ($42.52{\pm}0.05%$). Sesamin 1 exhibited a stronger radical-scavenging activity in the ABTS ($IC_{50}:\;63.2{\pm}2.4\;{\mu}M$) than its DPPH radical-scavenging activity ($IC_{50}>200\;{\mu}M$). These results lead to the conclusion that lignan content is affected by protein and oil contents. Concentration of the chemical components in the cultivars could be a key factor in the selection process of a high quality species.

Fiber-optic Goniometer to Measure Knee Joint Angle for the Diagnosis of Gait Disturbance (보행장애 진단을 위한 무릎관절 각도 측정용 광섬유 각도센서)

  • Kim, S.G.;Shin, S.H.;Jeon, D.;Hong, S.H.;Sim, H.I.;Jang, K.W.;Yoo, W.J.;Lee, B.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.1009-1013
    • /
    • 2013
  • In this study, we developed a fiber-optic goniometer for the continuous measurement of knee joint angle which provides important medical information on Alzheimer's disease. The fiber-optic goniometer is composed of a light-emitting diode (LED), a plastic optical fiber (POF), and a voltage output photodiode (PD). As a sensing part of the fiber-optic goniometer, a unclad fiber with regular intervals of 1 mm was fabricated to improve efficiency of bending loss according to the angle variation of knee joint. The emitting light with a center wavelength of 470 nm from a LED is guided by a POF to the PD, the transmitted light is then attenuated by the bending loss inside the bent POF. The intensity variation of the light transmitted from the POF gives rise to a change in output voltage in the fiber-optic goniometer. Therefore, we measured the real-time output voltage of the proposed fiber-optic goniometer using the unclad fiber according to the knee joint angle. Through the repeated experiments, the fiber-optic goniometer shows that it has a reversibility and a wide measurable angle range.

A Study on Optical Coherence Tomography System by Using the Optical Fiber (광섬유를 이용한 광영상단층촬영기 제작에 관한 연구)

  • 양승국;박양하;장원석;오상기;이석정;김기문
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.34-40
    • /
    • 2004
  • In this paper, we have studied the OCT(Optical Coherence Tomography) system which has been advantages of high resolution, 2-D cross-sectional images, low cost and small size configuration. The characteristics of light source determine the resolution and coherence length. The light source has a commercial SLD with a central wavelength of 1,285 ill11, 35.3 nm(FWHM). The optical delay line is necessary to make equal with the optical path length to scattered light or reflected light from a sample. In order to make equal the optical path length, the stage that is attached to a reference mirror is controled by a step motor. And the interferometer is configured with the Michelson interferometer by using a single mode fiber, and the scanner can be focused on the sample by using a reference ann Also, the 2-dimension cross-sectional images were measured with scanning the transverse direction of the sample by using a step motor. After detecting the internal signal of lateral direction, a scanner is moved to obtain the cross-sectional image of 2-dimension by using step motor. A photodiode, which has high detection sensitivity and excellent noise characteristics has been used. The detected small signal has a noise and interference. After filtering and amplifying the signal, the output signal is demodulated the waveform And then, a cross-sectional image is seen through converting this signal into a digitalized signal by using an AID converter. The resolution of the sample is about 30${\mu}{\textrm}{m}$, which corresponds to the theoretical resolution. Also, the cross-sectional images of onion cells were measured in real time scheme.

Simultaneous Analysis of Bangpungtongseong-san and Its Antioxidant Effect (방풍통성산의 동시분석 및 항산화 효능 연구)

  • Seo, Chang-Seob;Kim, Ohn Soon;Shin, Hyeun-Kyoo
    • Herbal Formula Science
    • /
    • v.21 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Objectives : We carry out the simultaneous quantification for quality control of four components in Bangpungtongseong-san (BPTSS) sample. In addition, we assessed the antioxidant effects of BPTSS sample. Methods : The used column for separation and analysis of four compounds was Luna C18 column and column oven temperature was maintained at $40^{\circ}C$. The mobile phase for simultaneous determination consisted of two solvent systems, 1.0% acetic acid in water and 1.0% acetic acid in acetonitrile. High performance liquid chromatography-photodiode array (HPLC-PDA) method for analysis was performed at a flow rate of 1.0 mL/min with PDA detection at 254 and 280 nm. The injection volume was 10 ${\mu}L$. The antioxidant activities of BPTSS were evaluated by measuring free radical scavenging activities on 2,2'-Azinobis-3-ethyl-benzothiazoline-6-sulfonic acid (ABTS) and 1-1-diphenyl-2-picrylhydrazyl (DPPH). The inhibitory effects on low-density lipoprotein (LDL) oxidation were evaluated by the formation of thiobarbituric acid relative substances (TBARS) and relative electrophoretic mobility (REM). Results : Calibration curves were acquired with $r^2{\geq}0.9999$. The values of limit of detection (LOD) and quantification (LOQ) were 0.06-0.29 ${\mu}g/mL$ and 0.20-0.98 ${\mu}g/mL$, respectively. The amounts of geniposide, liquiritin, baicalin, and glycyrrhizin in BPTSS were 5.06, 7.33, 27.56, and 7.81 mg/g, respectively. The BPTSS showed the radical scavenging activity in a dose-dependent manner. The concentration required for 50% reduction (RC50) against ABTS and DPPH radicals were 72.51 ${\mu}g/mL$ and 128.49 ${\mu}g/mL$. Furthermore, GMGHT reduced the oxidation properties of LDL induced by CuSO4. Conclusions : The established HPLC-PDA method will be helpful to improve quality control of BPTSS. In addition, BPTSS has potentials as therapeutic agent on anti-atherosclerosis.

Fabrication and Characterization of a One-dimensional Fiber-optic Dosimeter for Electron Beam Therapy Dosimetry (치료용 전자선 계측을 위한 1차원 광섬유 방사선량계의 제작 및 특성분석)

  • Jang, Kyoung-Won;Cho, Dong-Hyun;Shin, Sang-Hun;Yoo, Wook-Jae;Jun, Jae-Hun;Lee, Bong-Soo;Moon, Joo-Hyun;Park, Byung-Gi
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.285-290
    • /
    • 2008
  • In this study, we have fabricated a one-dimensional fiber-optic dosimeter for electron beam therapy dosimetry. Each fiber-optic dosimeter has an organic scintillator with a plastic optical fiber and it is embedded and arrayed in the plastic phantom to measure one-dimensional high energy electron beam profile of clinical linear accelerator. The scintillating lights generated from each sensor probe are guided by plastic optical fibers to the multi-channel photodiode amplifier system. We have measured one-dimensional electron beam profiles in a PMMA phantom according to different field sizes and energies of electron beam. Also, the isodose and three-dimensional percent depth dose curves in a PMMA phantom are obtained using a one-dimensional fiber-optic dosimeter with different electron beam energies.

  • PDF

Isolation and Development of Quantification Method for Cyanidin-3-Glucoside and Cyanidin-3-Rutinoside in Mulberry Fruit by High-Performance Countercurrent Chromatography and High-Performance Liquid Chromatography

  • Choi, Soo-Jung;Jeon, Heejin;Lee, Chang Uk;Yoon, Shin Hee;Bae, Soo Kyung;Chin, Young-Won;Yoon, Kee Dong
    • Natural Product Sciences
    • /
    • v.21 no.1
    • /
    • pp.20-24
    • /
    • 2015
  • Cyanidin-3-glucoside (C3G) and cyanidin-3-rutinoside (C3R) were isolated by high-performance countercurrent chromatography (HPCCC) using a two-phase solvent system composed of tert-butyl methyl ether/n-butanol/acetonitrile/water/trifluoroacetic acid (1 : 3 : 1 : 5 : 0.01, v/v) to give pure C3G (34.1 mg) and C3R (14.3 mg) from 1.5 g crude mulberry fruit extract. Using the pure C3G and C3R, a reliable high-performance liquid chromatography (HPLC) method was developed and validated to determine the C3G and C3R contents in mulberry fruit. C3G and C3R were separated simultaneously using an Eclipse XDB-C18 column ($4.6{\times}250mm$ I.D., $5{\mu}m$) coupled with a photodiode array detector (PDA). The gradient elution of the mobile phase consisting of acetonitrile (0.5% formic acid) and water (0.5% formic acid) was applied (1.0 mL/min), and the detection wavelength was 520 nm. The calibration curves of C3G and C3R showed good linearity (both with $r^2=0.9996$) in the concentration range $15.625-500{\mu}g/mL$, and the relative standard deviations (RSD%) of intra- and inter-day variability were in the ranges 2.1 - 8.2% and 4.1 - 17.1%, respectively. The accuracies were ranged 96.5 - 102.6% for C3G and C3R, respectively. The developed HPLC method was used to determine the contents of C3G and C3R in newly harvested mulberry from eight different provinces of Korea.

Analysis of Phenolic Compounds in Sorghum, Foxtail Millet and Common Millet

  • Jeon, Hyun-Seok;Chung, Ill-Min;Ma, Kyung-Ho;Kim, Eun-Hye;Yong, Soo-Jung;Ahn, Joung-Kuk
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.56 no.4
    • /
    • pp.361-374
    • /
    • 2011
  • The cereal grain crops have strong flexibility against adverse environment and they have various functional compounds. The objective of the present study was to screen phenolic compounds in sorghum [Sorghum bicolor (L.) Moench], foxtail millet (Setaria italica), common millet (Panicum miliaceum L.) by high performance liquid chromatography (HPLC) with photodiode array (PDA) detector. Sorghum contained the highest amount of phenolic compounds among three different crops (sorghum, foxtail millet, common millet). Especially Moktaksusu showed the highest amount of phenolic compounds concentrations and biggest regional differences. The comparison of average phenolic compounds in sorghums by regions showed order to Milyang ($963.3\;{\mu}g{\cdot}g^{-1}$), Yeongyang ($923.1\;{\mu}g{\cdot}g^{-1}$), Gijang ($831.3\;{\mu}g{\cdot}g^{-1}$) and Bonghwa ($735.6\;{\mu}g{\cdot}g^{-1}$). Among the sorghum cultivars, Moktaksusu ($1407.9\;{\mu}g{\cdot}g^{-1}$) had the highest concentration of phenolic compounds. The average phenolic compounds of foxtail millets showed similar amount among Milyang ($319.0\;{\mu}g{\cdot}g^{-1}$), Gijang ($288.1\;{\mu}g{\cdot}g^{-1}$) and Bonghwa ($281.9\;{\mu}g{\cdot}g^{-1}$) areas. The phenolic compounds of Yeongyang ($246.6\;{\mu}g{\cdot}g^{-1}$) slightly low and that showed similar concentrations among three different regions. The concentration of phenolic compounds in foxtail millets, Chungchajo ($335.6\;{\mu}g{\cdot}g^{-1}$) showed the highest concentrations. The average phenolic compounds of common millets showed the highest concentrations in Milyang ($305.5\;{\mu}g{\cdot}g^{-1}$), Bonghwa ($262.0\;{\mu}g{\cdot}g^{-1}$), Gijang ($195.1\;{\mu}g{\cdot}g^{-1}$), Yeongyang ($237.2\;{\mu}g{\cdot}g^{-1}$) in decreasing order. The concentration of phenolic compounds of common millets was the highest in the Norangchalgijang ($337.0\;{\mu}g{\cdot}g^{-1}$), Hwanggumgijang ($250.0\;{\mu}g{\cdot}g^{-1}$) was also relatively higher than others. The results of this study will provide basic information for breeding sorghums, foxtail millets and common millets with higher phenolic compound concentrations.

Image Quality Evaluation of Medical Image Enhancement Parameters in the Digital Radiography System (디지털 방사선시스템에서 영상증강 파라미터의 영상특성 평가)

  • Kim, Chang-Soo;Kang, Se-Sik;Ko, Seong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.329-335
    • /
    • 2010
  • Digital imaging detectors can use a variety of detection materials to convert X-ray radiation either to light or directly to electron charge. Many detectors such as amorphous silicon flat panels, CCDs, and CMOS photodiode arrays incorporate a scintillator screen to convert x-ray to light. The digital radiography systems based on semiconductor detectors, commonly referred to as flat panel detectors, are gaining popularity in the clinical & hospital. The X-ray detectors are described between a-Silicon based indirect type and a-Selenium based direct type. The DRS of detectors is used to convert the x-ray to electron hole pairs. Image processing is described by specific image features: Latitude compression, Contrast enhancement, Edge enhancement, Look up table, Noise suppression. The image features are tuned independently. The final enhancement result is a combination of all image features. The parameters are altered by using specific image features in the different several hospitals. The image in a radiological report consists of two image evaluation processes: Clinical image parameters and MTF is a descriptor of the spatial resolution of a digital imaging system. We used the edge test phantom and exposure procedure described in the IEC 61267 to obtain an edge spread function from which the MTF is calculated. We can compare image in the processing parameters to change between original and processed image data. The angle of the edge with respect to the axes of detector was varied in order to determine the MTF as a function of direction. Each MTF is integrated within the spatial resolution interval of 1.35-11.70 cycles/mm at the 50% MTF point. Each image enhancement parameters consists of edge, frequency, contrast, LUT, noise, sensitometry curve, threshold level, windows. The digital device is also shown to have good uniformity of MTF and image parameters across its modality. The measurements reported here represent a comprehensive evaluation of digital radiography system designed for use in the DRS. The results indicate that the parameter enables very good image quality in the digital radiography. Of course, the quality of image from a parameter is determined by other digital devices in addition to the proper clinical image.

Design and Fabrication of APD-FET Module for 2.5 Gbps Optical Communicating System (광통신용 APD-FET 광수신모듈 설계 및 제작)

  • 강승구;송민규;윤형진;박경현;박찬용;박형무;윤태열;이창희;심창섭
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.166-172
    • /
    • 1994
  • The fiber optic receiver, ETRI APD-FET 1.0, is developed for the application of optical communication. This fiber optic receiver includes PD sub-module and pre-amplifier case. A single lens system is introduced for the PD sub-module. The sub-module consists of the avalenche photodiode(APD), GRIN rod lens, and a single mode fiber. The above components are enclosed into the stainless steel 304L housings. By bevelling the fiber end, the single mode fiber provides less than ~ 28 dB of optical return loss. The area of image focus is controlled by adjusting the length of spacer located in-between the fiber and the GRIN rod lens. The laser welding technique is applied to achieve the maximum coupling efficiency for the joining of each housing. In the pre-amplifier case, GaAs FET pre-amplifier workes for photocurrent amplification and the thermister is mounted to control the APD bias. The performance of ETRI APD-FET1.0 shows the sensitivity of - 30.3 dBm at $10^{-10}$ BER(bit error rate) and 2.5 Gbps optical random signal of $2^{23}-1$ word length. The fiber optic receiver is one of the essensial parts of the transmission module for B-ISDN. Also, the above optical packaging technology will be adapted for the developement of 10 Gbps transmission application 2.5 Gbps 5 Gbps

  • PDF