• 제목/요약/키워드: Photo diode

검색결과 256건 처리시간 0.03초

광다이오드를 이용한 산소포화도 및 맥박 측정기 설계 (Design of blood oxygen concentration and heart beat rate measuring system using photo diode)

  • 김인건;남태훈;정익주
    • 산업기술연구
    • /
    • 제33권A호
    • /
    • pp.49-54
    • /
    • 2013
  • The U-healthcare is increasingly important as there is a growing tendency for elderly people to acquire chronic disease such as heart problems and high blood pressure. In this paper, we implemented an oximeter which can interact and communicate with the smart devices such as smartphones through which users can manage their measuring data. The designed pulse oximeter is capable of detecting hemoglobin saturation levels in the range of 70-100% and the heart beat rate(BPM) in the range of 30-240 BPM.

  • PDF

주변 조도 변화에 따라서 TFT LCD의 Contrast Ratio를 자동 조절하는 방법 (Automatic control method of the TFT LCD's Contrast Ratio according to ambient light)

  • 김상현;손재식;한관영;이준신
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.125-129
    • /
    • 2005
  • Mobile display는 사용자가 이동하면서 화면을 보기 때문에 주변 luminance의 변화에 따라서 contrast ratio 변화가 심하다. 특히 햇빛 아래에서는 Mobile display의 화면을 알아보기 어렵다. 본 연구에서는 주변 조도가 증가할수록 TFT LCD의 black 휘도의 변화율이 white 휘도 변화율보다 크게 작용하여 전체 contrast ratio(이하 CR)가 크게 감소함올 확인하였다. 또한, 반투과형 LCD는 반사창을 통해서 외부 빛올 반사시키기 때문에 주변 조도가 높아도 일정 수준의 CR은 유지할 수 있다. 그러나 투과형 LCD보다 CR이 낮았다. 본 논문에서는 투과형 TFT LCD에 back light 광원으로 LED를 사용하고, photo diode와 LED drive IC를 이용하여 주변 조도의 광량에 따라서 LCD의 back light LED의 휘도를 3단계 조절할 수 있는 회로를 구성하였다. 이렇게 함으로써 주변 조도에 따라 자동으로 back light 휘도 조절이 가능한 결과을 얻었다.

  • PDF

ppb Level 실리카 측정시스템 개발에 관한 연구 (A Study on the Development of ppb Level Dissolved Silica Measuring System)

  • 정경열;오상훈;이후락;동은석;이수태;류길수
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2000년도 추계학술대회 논문집(Proceeding of the KOSME 2000 Autumn Annual Meeting)
    • /
    • pp.143-151
    • /
    • 2000
  • Dissolved silica is make some critical trouble at steam turbine. And, we must measure it to ppb level. We were looking for the best measuring method of the silica. Via this study, we could found it in the N-IR spectroscopy technology. This dissertation have been discuss about system structure, system fundamentals and performance test. At the test, we were study in the spectral interference of $NH_3$. We know that existing system had some problem. It is structural frailties of single beam type. Therefore we were study for double beam type structure. And we obtain a good result. In the result, it have been discuss that conduct a test of $NH_3$ effect.

  • PDF

Michelson 간섭계에 의한 고체의 선팽창계수 측정방법 (Measurement Method of Linear Expansion Coefficient for Solid Matter using Michelson Interferometer)

  • 김홍균;김영선
    • 공학교육연구
    • /
    • 제16권2호
    • /
    • pp.24-30
    • /
    • 2013
  • This paper deals with the measurement theory and technique of linear expansion coefficient for solid material using Michelson interferometer. The Michelson interferometer produces interference fringes by splitting a beam of monochromatic light so that one beam strikes a fixed mirror and the other a movable mirror. When the reflected beams are brought back together, an interference pattern results. Precise distance measurements until a quarter of wave length can be made with the Michelson interferometer by moving the mirror and counting the interference fringes which move by a photo diode. This paper represents the application of Michelson interferometer for measuring infinitesimal length system and shows the measurement method of linear expansion coefficients for various materials like copper, aluminum and iron. the results are good agreement with theoretical value within margin of error for each materials.

3차원 레이저 스캐너용 ND 필터의 시뮬레이션 (Simulation of ND Filter for Terrestrial Laser Scanner)

  • 양수효;오동근;정중연
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2009년도 춘계학술발표회 논문집
    • /
    • pp.65-73
    • /
    • 2009
  • The terrestrial laser scanner measures the signal delay time of electronic circuit in EDM(Electronic Distance Measurement) Module for distance measurement. To measure signal delay time precisely, transmitting laser beam of terrestrial laser scanner is divided optically. Therefore, 10% of the laser beam power is entered into the electronic circuit and the others go out through lens. But, measure of delay time is severe in the laser scanner system that the laser beam power is changed dynamically by reflectance of a object, because characters like gain of electronic circuit involving APD(Avalanche Photo Diode) and so on are changed by incident laser beam. Therefore, we adapt ND(Neutral Density) filter that has grid pattern to the laser scanner system to keep constant the incident laser beam power. In this paper, we propose the simulation program for efficient design of ND filter pattern. Finally, to affirm simulation program, we conduct the experimental test of simulated ND filter that has linearly transmittance change, and we consider the experiment result.

  • PDF

SOI 기판을 이용한 Thermal Probe 어레이 제작 및 특성 평가 (Fabrication and Characterization of Thermal Probe Array on SOI Substrates)

  • 조주현;나기열;박근형;이재봉;김영석
    • 한국전기전자재료학회논문지
    • /
    • 제18권11호
    • /
    • pp.990-995
    • /
    • 2005
  • This paper reports the fabrication and characterization of $5\;\times\;5$ thermal cantilever array for nano-scaled memory device application. The $5\;\times\;5$ thermal cantilever array with integrated tip heater has been fabricated with MEMS technology on SOI wafer using 7 photo masking steps. All single-level cantilevers have a diode in order to eliminate any electrical cross-talk between adjacent tips. Electrical measurements of fabricated thermal cantilever away show its own thermal heating mechanism. Thermal heating is demonstrated by the reflow of coated photoresist on the cantilever array surface.

광파이버를 이용한 관절각 센서의 개발 (The development of joint angle sensor using optical fiber)

  • 이현희;임승관;정호춘;이태호;진달복
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 B
    • /
    • pp.593-596
    • /
    • 1997
  • The main purpose of this paper is to develop sensing device of joint angle using loss of opfical fiber. The source of light to optical fiber is infrared rays diode, and receiver is a photo transistor. The bent angle of optical fiber is measured with rotary encoder, and The change of voltage due to the loss of light is measured with micro computer PIC16C74. The sensing device may be used to Functional Electrical stimulation(FES) System for Rehabilitation patient.

  • PDF

Decision directed PLL을 이용한 BPSK Homodyne 광 수신기의 성능에 관한 연구 (A Study on the Performance of BPSK Homodyne Optical Receiver User the Decision Directed PLL)

  • Lee, Ho-Joon
    • 대한전자공학회논문지
    • /
    • 제27권4호
    • /
    • pp.598-603
    • /
    • 1990
  • This study evaluates the performance of an optical receiver for binary phase shift keying (BPSK) signals in the presence of short noise originating from the photo diode and phase noise of the optical source. The case of using I.O. hybrid compare with the fiber optic hybrid to mix received optical signal and laser local oscillator signal. The impact of these noise is minimized if loop natural frequency and power split ratio between data and carrier recovery branch are choosen optimally. Then it is obtained that required laser linewidt to achieve a BER of 10**-9. The results are the same except theat in case of using the fiber optic hybrid the required optical power is twice as much as the I.O. hybrid.

  • PDF

휴대용 근적외선 분광분석기를 이용한 비침투 혈당 측정 (Non-invasive Blood Glucose Measurement by a Portable Near Infrared (NIR) System)

  • 강나루;우영아;차봉수;이현철;김효진
    • 약학회지
    • /
    • 제46권5호
    • /
    • pp.331-336
    • /
    • 2002
  • The purpose of this study is to develop a non-invasive blood glucose measurement method by a portable near infrared (NIR) system which was newly integrated by our lab. The portable NIR system includes a tungsten halogen lamp, a specialized reflectance fiber optic probe and a photo diode array type InGaAs detector; which was developed by a microchip technology based on the lithography. Reflectance NIR spectra of different parts of human body (finger tip, earlobe, and inner lip) were recorded by using a fiber optic probe. The spectra were collected over the spectral range 1100 ∼ 1740 nm. Partial least squares regression (PLSR) was applied for the calibration and validation for the determination of blood glucose. The calibration model from earlobe spectra presented better results, showing good correlation with a glucose oxidase method which is a mostly used standard method. This model predicted the glucose concentration for validation set with a SEP of 33 mg/dL. This study indicated the feasibility for non-invasive monitoring of blood glucose by a portable near infrared system.

Splitted Beam Type On-line 실리카 분석기 개발에 관한 연구 (A Stuty on Development of Spitted beam Type On-line Silica Analyzing sysyem)

  • 정경열;이후락
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.43-56
    • /
    • 2000
  • N-IR spectroscopy technology is very useful. And, the technology has wide application range. In the range, we know that single beam type silica analyzer has some handicap. So we were studied Splitted beam type silica analyzer. This dissertation have been discuss about system structure, system fundamentals and performance test. At the test, we were study in the spectral interference of NH3. We know that existing system had some problem. It is structural frailties of single beam type. Therefore we were study for Splitted beam type structure. And we obtain a good result. We have $\pm$5% accuracy and 0.5 ppb level measuring range. But, we have a question. It is ppt level measuring technology by the laser beam spectroscopy.

  • PDF