• 제목/요약/키워드: Photo detector

검색결과 196건 처리시간 0.034초

Performance and functionality of SRI detector array and focal plane electronics

  • Kim, Young-Sun;Kong, Jong-Pil;Heo, Haeng-Pal;Park, Jong-Euk;Chang, Young-Jun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.804-807
    • /
    • 2006
  • The SRI(Super Resolution Imager) with 800mm aperture primary mirror is the ground development model of the high resolution satellite camera. The SRI focal plane electronics including detector array generates the data for high-resolution images by converting incoming light into digital stream of pixel data. Since the focal plane including a detector is the basic building block of the camera system, the main system performances is directly determined by its performance. This paper measures the SRI focal plane electronics’ performance such as the dark signal, the dark signal noise, the linearity, the PRNU(Photo Response Non-Uniformity), the SNR(Signal to Noise Ratio) and the sensor saturation capability. In addition, this paper verifies the various functionalities of the SRI focal plane electronics. The electrical test equipment with the specialized software and the optical test equipments such as the integrating sphere, the rotation stage and the target are implemented and used to verify these functionalities and performances.

  • PDF

감마선 조사에 의한 농약 성분의 분해 연구 (Study on Decomposition of Several Pesticides by Gamma-Irradiation)

  • 이주상;정수연;오승열;장범수;박상현
    • 방사선산업학회지
    • /
    • 제6권3호
    • /
    • pp.205-209
    • /
    • 2012
  • The decomposition of 50 pesticides present in an aqueous solution using ${\gamma}-irradiation$ from a $^{60}Co$ gamma-ray source was investigated using laboratory-scale experiment. The rates of decomposition were determined using a gas chromatography-electron capture detector (GC-ECD), high-performance liquid chromatography-photo diode array detector (HPLC-PDA), and HPLC-fluorescence detector (FLD). When the initial concentration of pesticides was 10 ppm, and the radiation dose was 2, 5, 10, 20, and 30 kGy, respectively, 14 pesticide samples showed high removal rates (>50%) at absorbed doses of more than 10 kGy. With the exception of procymidone, they were all completely removed at a 30 kGy irradiation dose. These results provide fundamental data on the reactivity between gamma-irradiation and pesticides in an aqueous solution. Further, an evaluation of the toxicity of radiolytic intermediate products is required.

광통신을 위한 소자 기술

  • 박운출
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1991년도 광학 및 양자전자학 워크샵
    • /
    • pp.83-83
    • /
    • 1991
  • 1970年代 初에 開發된 光纖維는 化合物 半導體, Laser lc Photo-detector의 硏究開發과 더불어 光通信의 可能性을 確信케 했다. 國際的의 關心과 치열한 硏究開發 競爭으로 光通信技術은 1980年代 이미 實用化 段階에 到達케 되었음은 周知의 事實이다. 光通信 分野의 技術開發은 指定되어 電子部品이나 電子素子를 包含하지 않고 오직 光部品 또는 光素子만으로 構成된 全光通信 System이 廣帶域 ISDN(Broad Band ISDN)으로 곧 國際化 될 것이며, 21 世紀에는 光帶域 通信網이 Video, Audio, Data의 統合 Service 通信網으로 浮上 情報化 社會의 Ingra-structure가 될 것이다. 本發表에서는 이러한 光通信網을 構築하는데 必要한 部品 및 素子의 製造技術을 深度있게 說明코저 한다.

  • PDF

레이저 회절성을 이용한 입자크기 분포의 계측 및 해석 (Paticle size analyzer using laser diffraction)

  • 남부희;강성귀;유태우;방병렬;지규인
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.81-85
    • /
    • 1992
  • We design a multi-element photo-detector to measure the size of particles using the diffracted light energy distribution. The scattered profile measured by the photodetector is sampled by a 32 channel analog-to-digital converter. A nonnegative least squares analysis translates the light energy distribution into the corresponding unique particle size distribution. The responses of the particle sizing system are studied theoretically and experimentally.

  • PDF

Stretchable electronic eye-camera of silicon nano-ribbon photo-detector arrays

  • 하정숙
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.29-29
    • /
    • 2010
  • 기존의 반도체 공정을 기반으로 하는 소자구조는 주로 평면의 웨이퍼상에 만들어져왔다. 그러나, 제작된 소자 어레이를 늘림이 가능한 (stretchable) 폴리머 기판에 프린팅 전이하는 방식을 이용하면 어떤 형태의 곡면에도 소자 제작이 가능해진다. 이러한 프린팅 방식으로, 다양한 곡면에 실리콘 소자 어레이를 제작한 연구결과를 발표하고자 한다. 한 응용 예로 사람의 눈과 같은 반구형 표면에 실리콘 나노 리본으로 만든 광다이오드 어레이를 배열하여 전자 눈 카메라를 제작하여 성능을 확인하였다. 또한 수차를 최소화할 수 있는 포물면에 전자눈 카메라를 제작하여 평면카메라에 비해 이미지의 균일성이 우수함을 보여주고자 한다.

  • PDF

Measurement of Photo-Neutron Dose from an 18-MV Medical Linac Using a Foil Activation Method in View of Radiation Protection of Patients

  • Yucel, Haluk;Cobanbas, Ibrahim;Kolbasi, Asuman;Yuksel, Alptug Ozer;Kaya, Vildan
    • Nuclear Engineering and Technology
    • /
    • 제48권2호
    • /
    • pp.525-532
    • /
    • 2016
  • High-energy linear accelerators are increasingly used in the medical field. However, the unwanted photo-neutrons can also be contributed to the dose delivered to the patients during their treatments. In this study, neutron fluxes were measured in a solid water phantom placed at the isocenter 1-m distance from the head of an18-MV linac using the foil activation method. The produced activities were measured with a calibrated well-type Ge detector. From the measured fluxes, the total neutron fluence was found to be $(1.17{\pm}0.06){\times}10^7n/cm^2$ per Gy at the phantom surface in a $20{\times}20cm^2$ X-ray field size. The maximum photo-neutron dose was measured to be $0.67{\pm}0.04$ mSv/Gy at $d_{max}=5cm$ depth in the phantom at isocenter. The present results are compared with those obtained for different field sizes of $10{\times}10cm^2$, $15{\times}15cm^2$, and $20{\times}20cm^2$ from 10-, 15-, and 18-MV linacs. Additionally, ambient neutron dose equivalents were determined at different locations in the room and they were found to be negligibly low. The results indicate that the photo-neutron dose at the patient position is not a negligible fraction of the therapeutic photon dose. Thus, there is a need for reduction of the contaminated neutron dose by taking some additional measures, for instance, neutron absorbing-protective materials might be used as aprons during the treatment.

15센티 이격거리의 수중 객체간 P2P VLC 음원전송 기술에 관한 연구 (A Study on P2P VLC Sound Transmission Technology between Underwater Object of 5cm Distance)

  • 김영민;신재권;차재상
    • 한국위성정보통신학회논문지
    • /
    • 제10권3호
    • /
    • pp.44-47
    • /
    • 2015
  • 본 논문에서는 15센티 이격거리의 수중 객체간 P2P VLC 음원전송 기술에 대하여 제안하였다. P2P VLC 음원전송 기술을 제시하였으며, 이와 더불어 LED 송신모듈와 PD(Photo Detector) 수신모듈간 15센티 이격거리에서의 P2P VLC 음원전송 기술을 개발하였다. 수중환경이라는 가정 하에 LED 송신부와 PD 수신부간 음원 전송을 위한 수중 객체간 P2P VLC 음원 전송 실험을 진행하였으며, 이를 통하여 제안기술의 유용성을 입증하였다. 본 논문에서 제안한 15센티 이격거리의 수중 객체간 P2P VLC 음원전송 기술은 수중 환경에서 객체간 P2P VLC 음원전송 기술을 이용할 수 있다는 점에서 다양한 분야에 널리 사용될 수 있을 것으로 기대된다.

주파수 천이를 이용한 광무선 시스템에서 EOM의 바이어스 방식에 따른 광링크 성능 분석 (Optic Link Performances on EOM′s Biasing in Fiber-radio System)

  • 오세혁;양훈기;최영완
    • 대한전자공학회논문지SD
    • /
    • 제38권2호
    • /
    • pp.128-136
    • /
    • 2001
  • 본 논문은 주파수 천이를 적용시킨 광무선(fiber-radio)시스템의 광링크부에 대한 성능분석을 한다. 제시된 광링크부는 CS(control station)에서 얻어진 밀리미터파 대역 광파일럿톤(optical pilot tone)이 하향링크뿐 아니라 상향링크에도 공급되도록 하여 BS(base station)의 구조를 간단히 하였다. 광파일럿톤을 얻기 위해 CS의 EOM(electro-optic modulator)을 MAB(maximum bias), MIB(minimum bias), QB(quadrature bias)로 바이어스를 달리할 수 있으며 각각의 경우에 따라 링크의 성능을 분석한다. 분석은 레이저 광원의 전력이 일정한 경우와 PD(photo detector)에 수신되는 광 DC 전력이 일정한 경우에 대해서 행하여지며 각 경우에 대해서 최적의 하향링크 CNR 및 상향링크 SFDR(spurious free dynamic range)을 얻기 위해 효과적인 바이어스 방식을 제시한다

  • PDF

Broad Beam Gamma-Ray Spectrometric Studies with Environmental Materials

  • El-Kateb, Abdul-Hamid Hussein
    • Journal of Radiation Protection and Research
    • /
    • 제43권2호
    • /
    • pp.75-84
    • /
    • 2018
  • Background: Gamma-ray spectrometry helps in radiation shielding problems and different applications of radioisotopes. Experimental arrangements including broad beam geometries are widely used. The aim is to investigate and evaluate the ${\gamma}-ray$ spectra via attenuation by environmental materials. Materials and Methods: The photo peak to nominated parts in the ${\gamma}-ray$ spectra and the attenuation coefficients ${\mu}_b/{\rho}$ from broad beam geometries are measured for the materials water, soil, sand and cement at the energies 0.662, 1.25, and 1.332 MeV with a $3{^{\prime}^{\prime}}{\times}3{^{\prime}^{\prime}}$ NaI(Tl) detector. Results and Discussion: The ${\gamma}-ray$ spectra vary according to changes in the effective atomic number $Z_{eff}$ of the attenuator, the photon energy and the solid angle. The peak to total ratios are the most sensitive parts to variations in the experimental conditions and overturn in the region 0.663 MeV to 1.332 MeV. This is indicated as inversion trend. The results are discussed in view of $Z_{eff}$ and the experimental conditions. The intensity build-up is larger at the lower energy and larger scattering angles in agreement with Klein-Nishina formula and other results. The build-up factor B is$${\sim_=}$$1 at high ${\gamma}-energies$ and small scattering angles. Conclusion: The sensitivity to material characteristics decrease gradually from peak: to total, to Compton valley, to Compton plateau ratios. Rigorous collimation is necessary at small energies. Cement, of the largest $Z_{eff}$, is characterized by the maximum broad beam mass attenuation coefficients ${\mu}_b/{\rho}$. The obtained results provide information to decide for the suitable experimental set-up based on aim of the work.

가스절연기기(GIS)의 인위적 결함에 의한 부분방전의 검출을 위한 Probe-Type Pockels Sensor의 적용 가능성 (A possible application of the partial discharge measurement due to artificial defect using Pockets sensor in GIS(Gas Insulated Switchgear))

  • 류철휘;이재호;마지훈;강원종;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1770-1772
    • /
    • 2003
  • 본 연구는 국내에서 최초로 제안되고 적용가능성이 입증되어 설계, 제작된 Probe-type Pockets sensor(HY-Pockets Sensor)를 GIS등의 고전압 장비들에 응용한 레이저 부분방전 진단 시스템 개발을 목표로 하고 있다. 이러한 목적으로, 170kV 급 실 규모 GIS내부의 전류 도체에 다양한 곡률 반경의 침 전극을 부착시켜 부분 방전에 기인된 불평등 전계를 형성시켜 개발된 센서의 실규모 적용 가능성을 고찰하였다. 본 레이저 계측 시스템은 He-Ne laser, single multi-mode optical fiber, $2{\times}2$ 50/50 laser to single mode fiber coupler, probe-type Pockets sensor, photo detector 등으로 구성하여 레이저의 진행을 유도하고, 신호의 특성을 분석하였다. probe-type Pockets sensor로부터 의 출력 신호는 photo detector를 통해 전기적 신호로 변환되어 digital oscilloscope에 의해 측정되고, 또한 PC를 통해 데이터의 저장과 통계적, 분석적 처리 과정을 수행하게 된다. 본 연구의 결과로서 부분방전원에서 생성된 방전 신호에 대한 거리에 따른 센서 감도 결정, 그에 대한 센서 감도의 보정 향상, 전계의 세기의 변화에 따른 센서의 선형성 등이 도출되었고, 이러한 실험결과를 통해 실 GIS(170kv급) 내부에서 발생하는 부분방전의 검출에 본 레이저 부분방전 진단 시스템의 적용 가능성이 제시 되었다.

  • PDF