• Title/Summary/Keyword: Phenolic foam insulation

검색결과 7건 처리시간 1.251초

가속화 시험을 통한 페놀폼 단열재의 장기성능 비교분석에 관한 연구 (Study on Long-term Performance of Phenolic Foam Insulation through Accelerated Aging Test)

  • 김진희;김상명;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제40권2호
    • /
    • pp.11-23
    • /
    • 2020
  • The application of the high-performance insulation materials for buildings seems to be an essential measure for reducing energy use in buildings. Phenolic foam is a readily available insulation material with thermal conductivity of about 0.018 to 0.020 W/(mK). It has the advantage of higher thermal resistance and better fire resistance compared to other conventional building insulation materials. Insulation material used for building envelope is regarded as one of the decisive factors for building's energy load. Furthermore, the degradation of its thermal performance over time increasingly affects the building's energy use demand. Generally, the life span of conventionally built buildings is expected to be more than 50 years, so the long-term performance of insulation materials is critical. This paper aims to evaluate the long-term performance of phenolic form boards through an accelerated aging test. The tests were conducted according to BS EN 13166 and KS M ISO 11561. Based on the results of the accelerated aging test, the thermal performance variation of the material was analyzed, and then its aged value after 25 years was computed. Also, the characteristics of the phenolic foam board's long-term performance were also examined based on the standard testing methods adopted.

건축물 외단열재의 열전달평가를 통한 화재 억제 방안 연구 (Study on the Fire Suppression by Heat Transfer of Thermal Insulation Materials)

  • 류화성;신상헌;송성용;김득모
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.277-278
    • /
    • 2018
  • Improvement of insulation performance of buildings is a major part. Adiabatic method The adiabatic method minimizes the heat loss of the building. External insulation uses insulation to prevent fire. Ambient air hazards are less prone to fire. When a fire occurs, a phenolic pattern is formed and bond strength with the wall increases. EPS insulation and phenol foam were used to compare external heat transfer and external heat transfer. The heat transfer properties of phenolic foam and styrofoam were evaluated as follows. In the mortar and styrofoam structure, the problem of styrofoam reaching the burning point occurred before the collapse of the mortar, and the phenol foam had a problem in that when the direct fire was continued on the phenol foam. The characteristics of continuous infiltration appeared. In the case of mortar and phenol foam + styrofoam, the heat penetrated into the interior due to the shrinkage due to the shrinkage of the carbon screen on the phenol foam. However, when reinforced with glass mesh on the outer surface, And to reduce infiltration.

  • PDF

다층형 단열재의 구성 형식에 따른 강도 특성 연구 (Strength Properties of Multi-layered Insulation according to the Type of Configuration)

  • 류화성;신상헌;송성용;김득모
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.141-142
    • /
    • 2019
  • As part of the recent low-energy policy, insulation standards for buildings are increasing every year. In addition, the conventional styrofoam heat insulation material has a problem in that the thickness of the heat insulation material to achieve the standard heat transmission rate is rapidly increased. Although the risk of spreading the structure vulnerable to fire due to insufficient spacing between buildings due to thickened insulation is increasing, the high cost of high efficiency insulation is difficult to solve. On the other hand, it is known that the method to be used as a formwork using insulation is excellent in cost reduction effect by reducing the amount of formwork used and simplifying the subsequent insulation work. The purpose of this study is to evaluate the strength characteristics of multi - layered insulation materials with appropriate strength by reducing the thickness of the insulation by appropriately combining high performance phenolic foam insulation and styrofoam insulation.

  • PDF

유기질 단열재 종류별 수중정치기간에 따른 pH 변화에 관한 연구 (SOrganic matter insulation by type of Study on pH change according to underwater settling period)

  • 홍상훈;유남규;서은석;김해나;김봉주;정의인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.87-88
    • /
    • 2019
  • Research has been conducted in many fields for the zero energy of domestic buildings. Among them, the development of insulation has become an essential element. Accordingly, researches are being made to improve the performance of organic insulating materials, and PF boards having the lowest thermal conductivity among organic insulating materials have been in the spotlight. However, problems have arisen due to the problems of durability of insulation materials such as PF boards and past acidification, and the durability of insulation materials is deteriorated when moisture or water enters due to crack gaps during the insulation of the basement layer or the external insulation method. In regard to the durability of the insulation, when the organic insulators of different kinds were placed in water, the pH was weakly basic in all organic insulation materials except PF, and the PF was about 4 pH. As a result, the PF should be continuously reviewed, and further analysis should be carried out to determine what causes acidification.

  • PDF

고성능 진공단열재의 건축적인 적용에 관한 연구 (Research on the Architectural Applications of High-Performance Vacuum Insulation Panel)

  • 권영철;김석
    • 토지주택연구
    • /
    • 제10권3호
    • /
    • pp.23-32
    • /
    • 2019
  • 현존하는 단열재 중 가장 열전도율이 낮은 진공단열재(VIP; Vacuum Insulation Panel)는 특수한 재질의 외피재(Envelope)와 외피재 내부의 심재(Core Material), 그리고 단열재 내부의 공기를 흡착하는 흡착제(Getter)로 구성되어 있고, 단열성능을 극대화하기 위해 내부를 진공처리한 제품이다. 진공단열재의 외피재는 알루미늄 박막 필름이 주로 사용되며, 진공단열재의 수명 및 신뢰성을 결정하는 중요한 소재이다. 본 연구를 통하여 불연성이 확보된 Fiber Glass 심재 진공단열재의 방화성능 및 단열성능 확인과 함께 건축적인 적용가능성을 검토하였으며 그 내용을 정리하면 다음과 같다. 1) 20mm 두께의 Fiber Glass 심재 진공단열재의 열전도율이 0.00177W/m·K로, 두께 20mm로 지역별, 부위별 강화된 단열기준을 모두 충족할 수 있음을 알 수 있었다. 2) 진공단열재에 대한 불연성능시험과 가스유해성시험 결과, 불연재료로 적합한 것으로 나타났다. 3) 불연 진공단열재의 장기내구성 시험결과, 25년이 지나더라도 스치로폼 및 유리섬유에 비해 10배 이상의 단열성능을 유지할 수 있음을 알 수 있었다. 4) 건물의 외벽 열관류율 0.12W/㎡K 이하를 만족하기 위해, 준불연성능이 확보된 단열재인 "가"등급의 비드법 보온판 2종 4호와 페놀폼을 사용한다면 각각 280mm, 170mm 이상을 써야하지만, 불연 진공단열재는 20mm 두께로 동일 단열기준을 만족할 수 있는 것으로 나타났다.5) 고성능 진공단열재는 열관류율 0.12W/㎡K 이하를 기준으로 가격경쟁력이 페놀폼 대비 약 1,500원/㎡ 뛰어난 것으로 나타났다.

다층형 단열재를 사용한 영구거푸집의 처짐 특성 (Deflection Characteristics of Permanent Formwork Using Multi-layer Insulation)

  • 류화성;신상헌;송성용;김득모
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.130-131
    • /
    • 2019
  • As part of recent low-energy policies, thermal insulation standards for buildings are being tightened every year. In addition, the conventional styrofoam insulating material has a problem that the thickness of the heat insulating material to achieve a standard heat permeability is rapidly increased. Due to the thick insulation, there is a high risk of spreading vulnerable structures such as fire due to lack of space between buildings. On the other hand, the method of using the insulation as a formwork is known to be excellent cost saving effect through the reduction of the formwork usage and the simplification of the external insulation work. In order to solve this problem, this study aims to fabricate a multi-layered insulator that combines high-performance phenolic foam insulation and styrofoam insulation and evaluate the deflection characteristics for use as formwork.

  • PDF

가스유해성 평가방법에 따른 유기단열재의 연소특성에 관한 연구 (A Study on the Combustion Characteristics of Organic Insulation Materials According to the Gas Toxicity Evaluation Method)

  • 심지훈;이재걸;한경호;김주완;송석훈;조형원;윤도영
    • Korean Chemical Engineering Research
    • /
    • 제60권4호
    • /
    • pp.519-524
    • /
    • 2022
  • 국내 건축물 마감재는 국토교통부 고시에 따라 KS F 2271 기준에 의해 평가되어지고 있으며, 이 실험은 실험동물을 사용하여 평가하고 있다. 본 연구에서는 가연성이 높은 유기물 단열재 EPS, 우레탄, 페놀폼에 대해 실험을 진행하였다. 이 3종의 단열재가 연소 시 발생되는 유해성 가스에 의한 실험용 쥐의 평균행동정지시간을 측정하여, 실험용 쥐의 행동정지에 대한 원인을 분석하고자 하였다. 실험용 쥐의 행동정지에 대한 원인분석방법으로는 FTIR 분석과 연기밀도실험을 진행하였고, 마우스의 행동정지 원인을 입자상물질에 의한 질식과 가스상물질에 의한 독성흡입으로 구분하여 실험결과를 분석하였다. 실험결과 우레탄이 가장 유해한 단열재로 평가되었으며, 가스유해성 실험결과에 대한 원인분석으로 FTIR분석과 연기밀도 실험을 진행한 결과, 독성흡입에 의한 영향보다 질식에 의한 실험용 쥐의 행동정지가 높은 것으로 나타났다. 본 연구는 유해성가스의 원인분석에 대한 기초연구로서, 독성의 근거를 마련하고 나아가 다양한 재료와 가스에 대한 분석을 통하여 보다 구체적인 독성평가의 기준이 마련될 수 있을 것으로 기대된다.