• Title/Summary/Keyword: Phast

Search Result 54, Processing Time 0.021 seconds

A Study on Facility Criteria of Small Petrol Stations based on Quantitative Risk Assessment (정량적 위험성 평가에 기반한 간이 주유취급소 시설기준에 대한 연구)

  • Park, Wooin;Ku, Jae-Hyun;Song, Yong-Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.44-52
    • /
    • 2014
  • Small petrol stations have great potential for a wide distribution in metropolitan area in which the land value possesses primary installation cost of the facility. The objective of the present study is to propose appropriate facility regulations of small petrol stations in Korea that can be popularly installed in the future in terms of securing safety in addition to serviceability. The hazard analysis and damage prediction from the possible fire and explosion accidents were performed using a software, PHAST v.6.5. As essential components of the facility regulations proposed in this study, the regulations about the refueling lot, maximum capacity of underground tank, location of fixed refueling facilities, height of firewall for small petrol stations were subsequently compared with those for regular-sized petrol stations.

A Development of Intelligent Decision System by Safely Distance of GAS Storage Tank (가스 저장탱크 안전거리의 지적 결정 시스템 개발)

  • Leem Sa-Hwan;Huh Yong-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.721-726
    • /
    • 2006
  • This paper is on intelligent decision system by safety distance of gas storage tank(IDSG). The safety distance fixed up by law is used to prevent from the injury by explosion of storage tank on the spot. However, it is not easy for a layman to decide a proper safety distance considering the size, shape and place of the storage tank. Therefore, this thesis shows the user-friendly intelligent decision system which a layman can decide the Bas related law, the size, shape and place of the storage tank by the intelligent decision, and it is to make assurance doubly sure for safety supervision on the spot. Also, the paper can make the data for the damage influence distance of overpressure by the explosion of the storage tank calculated by the scaling law of Hopkinson with the fixed distance by law, and safety range can be grasped with the graphic which is printed by the PHAST(Process Hazard Analysis Software Tool) model using this data.

  • PDF

Explosion Simulations for the Quantitative Risk Analysis of New Energy Filling Stations (신에너지 충전소의 정량적 위험성 평가를 위한 폭발 시뮬레이션)

  • Dan, Seung-Kyu;Park, Kyung-Jun;Kim, Tae-Ok;Shin, Dong-Il
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.1
    • /
    • pp.60-67
    • /
    • 2011
  • The interest about new and renewable energy is increasing to reduce the burden of problems by depletion of fossil fuels and air pollutions. For example, LNG/CNG and LPG are expected to be replaced, especially in transportation use, by HCNG mixture and DME-LPG mixture, respectively. Because these new energies are still flammable gases, it is not inherently safe from the explosion. In this research, the quantitative risk analysis for using alternative mixtures in existing recharging facilities has been studied by using three types of explosion models (TNT equivalency model, PHAST and CFD-based FLACS) to manage the risk effectively. The differences of results by models were compared against, and the practical ways of when and how to use these models were suggested. It was also predicted that conventional gas filling stations would be converted as new energy stations without additional explosion risk.

Process Hazard Review and Consequence Effect Analysis for the Release of Chlorine Gas from Its Storage Tank (염소저장탱크에서의 가스 누출시 공정위험검토 및 결과영향분석)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.61-73
    • /
    • 2003
  • Most of the accidents occurred from the chemical plants are related to the catastrophic gas release events when the large amount of toxic materials is leaked from its storage tank or transmitting pipe lines. In this case, the greatest concerns are how the spreading behaviors of leakages are depended on the ambient conditions such as air stability and other environmental factors. Hence, we have focused on the risk assessments and consequential analysis for chlorine as an illustrative example. As appeared in the result, Fire & Explosion Index depicted it a bit dangerous with presenting the comprehensive degrees of hazard 90.7. And as a result of Phast6.0/ALOHA, the trends of each scenario appeared considerably identical although there are some differences in the resulting effects according to the input data for the Gas Model. The consequence analysis is performed numerically based on the dense gas mode. In the future, using more correct input data, material properties, and topographical configuration, the method of this research will be useful for the guideline of the risk assessment when the release of toxicants breaks out.

A Study on Damage Analysis Safety Distance Setting for LPG BLEVE (LPG BLEVE 피해분석 및 안전거리 설정에 관한 연구)

  • Kim, Jonghyuk;Lee, Byeongwoo;Kim, Jungwook;Jung, Seungho
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.6
    • /
    • pp.25-31
    • /
    • 2020
  • Boiling Liquid Expanding Vapor Explosion(BLEVE) can cause not only economic damage to the plant but also serious casualties. LPG accidents account for 89.6 percent of all accidents caused by gas leaks in Korea over the past nine years, while casualties from accidents also account for 73 percent of all accidents, according to statistics from the Korea Gas Safety Corporation. In addition, a potential explosion and a fire accident from one LPG storage tank may affect the nearby storage tanks, causing secondary and tertiary damage (domino effect). The safety distance standards for LPG used by LPG workplaces, charging stations, and homes in Korea have become stricter following the explosion of LPG charging stations in Bucheon. The safety distance regulation is divided into regulations based on the distance damage and the risk including frequency. This study suggests two approaches to optimizing the safety distance based on the just consequence and risk including frequencies. Using the Phast 7.2 Risk Assessment software by DNV GL, the explosion overpressure and heat radiation were derived according to the distance caused by BLEVE in the worst-case scenario, and accident and damage probability were derived by considering the probit function and domino effect. In addition, the safety distance between LPG tanks or LPG charging stations was derived to minimize damage effects by utilizing these measures.

Risk Assessment for High Capacity Multiport Hydrogen Refueling Station (대용량 멀티포트 동시 충전 기반 수소충전소 안전성 평가 연구)

  • CHOONGHEE JOE;SEUNGKYU KANG;BUSEUNG KIM;KYUNGSIK LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.5
    • /
    • pp.505-513
    • /
    • 2023
  • Hydrogen infrastructure is expanding. High-capacity hydrogen refueling stations offer advantages because they can refuel a variety of light and heavy-duty vehicles, and multi-port refueling technology is developing to reduce charging time for heavy-duty vehicles. In this study, we suggest directions to lower the risk by analyzing the risk factors for each process involved in the installation of a high-capacity multi-port hydrogen refueling station in Changwon city. We conducted both qualitative and quantitative risk assessments of the equipment to evaluate the station. A hazard and operability study was performed for qualitative risk assessment, and PHAST/SAFETI were used for quantitative risk assessment. Quantitative risk assessment was used to calculate the consequence analysis of the facility to ensure secure design prior to station development and to predict individual and societal risks in various scenarios. As a result, the station's risk level was determined to be as low as reasonably practicable.

A Study on Damage Effect from Major Accident of LPG Charging Facility - A case study of an LPG Charging and Automotive Outlet - (LPG 충전소 중대사고의 피해효과에 관한 연구 - 부천 LPG충전소 사고 사례를 중심으로 -)

  • Roh, Sam-Kew;Kim, Tae-Hwan;Ham, Eun-Gu;Hong, Chang-Moon
    • Korean Security Journal
    • /
    • no.2
    • /
    • pp.83-98
    • /
    • 1999
  • The LPG station's explosion at Bucheon city was a major accident which with rare frequency of occurrence but large damage effect. Therefore, to prevent similar accident in the future from LPG chargings stations which located at inner urban area, it needs to identify the damage effects of such facilities by comparing theoretically quantities risks-PHAST. The BLEVE effects from the accident showed similar level in case of heat flux, however, the over pressure level reflected at reduced distance. The structure damage to the nearby area showed comparatively large reduction of concrete strength and shape changes through by heat effect while the overpressure effect was small.

  • PDF

Performance Evaluation of Weir Structures Under Blast Loads (폭발하중에 의한 다기능-수중보 구조물 거동평가)

  • Jeon, Jun-Tai;Jung, Woo-Young;Ju, Bu-Seog
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2015.11a
    • /
    • pp.168-169
    • /
    • 2015
  • 최근 위험물질에 의한 폭발 및 테러의 위험성 증가로 인하여 사회간접자본 시설물인 댐/보, 원자력 발전소, 병원 구조물과 같은 주요 시설물의 폭발 안전성 평가 연구가 이슈화 되고 있어, 본 연구에서는 가스폭발에 의한 다기능 보 구조물의 거동을 평가하고 안전성을 분석 하고 자 한다. 본 연구에서 폭발 해석에 필요한 하중 조건 산정은 PHAST 프로그램을 사용하여 주변 온도 및 공기 특성 등을 고려한 약 5톤의 가스 폭발 조건을 구축 하였다. 또한 다기능 보 구조물의 거동 분석을 위해 구조물-지반 상호 작용을 고려한 2차원 유한 요소 모델을 구축하여 폭발에 의한 구조물 거동을 평가 하였다. 다기능 보 구조물의 수치해석 결과 보 구체와 Stilling Basin구조물 사이의 연결부에 응력집중 현상이 발생하는 것으로 평가 되었다.

  • PDF

A Development of Consequence Analysis System for Combustible Materials Release Events Based on HTML5 Web (HTML5 웹 기반 가연성 물질 누출 피해영향평가 시스템 개발)

  • Lee, Ugwiyeon;Ji, Hyunmin;Oh, Jeongseok;Cho, Wansu
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.39-60
    • /
    • 2019
  • Korea Gas Safety Corporation is developing consequence analysis system for combustible materials release events to enhance risk assessment technology and its efficiency. Unlike general consequence analysis programs, the final consequence area was implemented through ETA analysis based on API-581 standard, and a convenient user interface was constructed based on HTML5-based responsive web technology. In addition, a phase equilibrium module using third-order state equations (such as Peng-Robinson, SRK, and RK) and fugecity was implemented to analyze the mixture quality. Also. using the consequence analysis algorithm introduced in CCPS books and TNO Yellow Book, we developed material leak analysis module, fireball, pool fire, jet fire, flash fire, and vapor cloud explosion consequence assessment module. In addition, the conditions for calculating the safety distance were prepared with using the control values in the EIGA standard, PAC, and Bevi Reference Book.

A Study on Validation for Mapping of Gas Detectors at a BTX Plant (BTX 공정에서 Gas Detector Mapping 적정성 검토에 관한 연구)

  • Seo, Ji Hye;Han, Man Hyoeng;Kim, Il Kwon;Chon, Young Woo
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.168-178
    • /
    • 2017
  • In order to prevent major and chemical accidents, some of the plants which would like to install and operate hazard chemicals handling facilities must submit Off-site Consequence Analysis due to recent arisen leak accidents since 2015. A lot of chemical industrials choose gas detectors as mitigation equipment to early detect gas vapor. The way of placement of gas detectors has two methods; Code-based Design(CBD) and Performance-based Design. The CBD has principles for gas detectors to be installed with consideration for the place that is expected to accumulate gas, and the leak locations according to legal standards and technical guidelines, and has a possibility to be unable to detect by these rules to locate gas detectors by vapor density information. The PBD has two methods; a Geographic Method and Scenario based Method. The Scenario-based Method has been suggested to make up for the Geographic Coverage Method. This Scenario-based Method draw the best optimum placement of gas detectors by considering leak locations, leak speed information, leak directions and etc. However, the domestic placement guidelines just refers to the CBD. Therefore, this study is to compare existing placement location of gas detectors by the domestic CBD with placement locations, coverages and the number of gas detectors in accordance with the Scenario-based Method. Also this study has measures for early detecting interest of Vapor Cloud and suitable placement of gas detectors to prevent chemical accidents. The Phast software was selected to simulate vapor cloud dispersion to predict the consequence. There are two cases; an accident hole size of leak(8 mm) from API which is the highst accident hole size less than 24.5 mm, and a normal leak hole size from KOSHA Guide (1.8 mm). Detect3D was also selected to locate gas detectors efficiently and compare CBD results and PBD results. Currently, domestic methods of gas detectors do not consider any risk, but just depend on domestic code methods which lead to placement of gas detectors not to make personnels recognize tolerable or intolerable risks. The results of the Scenario-based Method, however, analyze the leak estimated range by simulating leak dispersion, and then it is able to tell tolerable risks. Thus it is considered that individuals will be able to place gas detectors reasonably by making objectives and roles flexibly according to situations in a specific plant.