• 제목/요약/키워드: Phase sequence

검색결과 925건 처리시간 0.025초

위상만을 이용한 신호복원의 유일성 판단법 (Uniqueness Criteria for Signal Reconstruction from Phase-Only Data)

  • 이동욱;김영태
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제50권2호
    • /
    • pp.59-64
    • /
    • 2001
  • In this paper, we propose an alternate method for determining the uniqueness of the reconstruction of a complex sequence from its phase. Uniqueness constraints could be derived in terms of the zeros of a complex polynomial defined by the DFT of the sequence. However, rooting of complex polynomials of high order is a very difficult problem. Instead of finding zeros of a complex polynomial, the proposed uniqueness criteria show that non-singularity of a matrix can guarantee the uniqueness of the reconstruction of a complex sequence from its phase-only data. It has clear advantage over the rooting method in numerical stability and computational time.

  • PDF

5지 신호교차로에서의 안전을 고려한 신호현시 설계 (Safety Enhanced Signal Phase Sequence Design of a Rotary with Five Leg Intersection)

  • 박재완;김진태;장명순
    • 대한교통학회지
    • /
    • 제20권7호
    • /
    • pp.23-29
    • /
    • 2002
  • 일반적으로 4지 또는 3지의 교차로가 설계·운영되고 있으나 적지 않게 5지 또는 그 이상 의 원형 신호교차로가 실질적으로 이용되고 있다. 접근로 수에 따른 교차로 형태별 분류에 의하면 5지 이상의 교차로에서의 상충지 점의 수는 4지 교차로의 그것보다 월등히 높아 설계지침에서도 4지 이하의 교차로를 설계할 것을 권하고 있으며 마찬가지로 5지 원형 신호교차로에서도 그 상충지점 수가 많다. 이러한 이유로 5지 신호 교차로의 신호 설계는 교통소통이 아닌 교통안전측면에서 신호현시 순서 및 길이가 결정되어야 할 필요가 있으며 또 그러한 현시순서는 교차로 내 원활한 교통의 흐름을 심각한 수준으로 방해하지 않을 필요가 있다. 본 연구에서는 5지 신호교차로의 안전을 고려한 현시순서설계 방안을 제시한다. 울산광역시에서 운영중인 공업탑 5지 신호교차로를 대상으로 현장자료를 수집하였으며, 신호시간 설계모형은 TRANSYT-7F를 적용했다. TRANSYT-7F에서의 최적 신호현시의 길이를 토대로 기본적으로 "한 현시에 2개 교통류의 이동" 원칙에 따라 재배열하였다. 제안된 방법으로 보정된 신호현시 순서 및 길이를 사용하여 모의실험한 결과 TRANSYT-7F에서 제시한 최적 신호현시 순서 및 길이를 적용한 것에 비하여 평균 6.2%지체도 증가가 있었으나 교차로 내 상충수를 61.5% 줄이는 결과를 도출하였다.

Nrf2 and Keap1 Regulation of Antioxidant and Phase II Enzyme Genes

  • Yamamoto, M.
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2002년도 Current Trends in Toxicological Sciences
    • /
    • pp.24-42
    • /
    • 2002
  • Antioxidant responsive element (ARE) mediates the transcriptional activation of the genes encoding phase II drug metabolizing enzymes and antioxidative stress genes. The ARE consensus sequence shows high similarity to NF-E2 binding sequence, a cisacting erythroid gene regulatory element.(omitted)

  • PDF

가속 방사광을 활용한 Fe함유 Al-Si-Cu 주조용 합금의 응고과정 실시간 관찰 및 분석 (Real-time Observation and Analysis of Solidification Sequence of Fe-Rich Al-Si-Cu Casting Alloy by Synchrotron X-ray Radiography)

  • 김봉환;이상환;야스다 히데유키;이상목
    • 한국주조공학회지
    • /
    • 제30권3호
    • /
    • pp.100-110
    • /
    • 2010
  • The solidification sequence and formation of intermetallic phase of Fe-rich Al-Si-Cu alloy were investigated by using real-time imaging of synchrotron X-ray radiation. Effects of cooling rate during uni-directional solidification on the resultant solidification behavior was also studied in a specially constructed vacuum chamber in the SPring-8 facility. The series of radiographic images were complementarily analyzed with conventional analysis of OM and SEM/EDX for phase identification. Detailed solidification sequence and formation mechanisms of various phases were discussed based on real-time image analysis. The growth rates of $\alpha$-AlFeMnSi and ${\beta}-Al_5FeSi$ were measured in order to understand the growth behavior of each phase. It is suggested that real-time imaging technique can be a powerful tool for the precise understanding of solidification behavior of various industrial materials.

3상 4선 계통에서의 순시전력 보상이론 (Instantaneous Power Compensation Theory in Three-phase Four-wire Systems)

  • 김효성
    • 전력전자학회논문지
    • /
    • 제11권2호
    • /
    • pp.172-183
    • /
    • 2006
  • 본 논문은 Akagi에 의해 발표된 p-q 이론과 Nabae 및 Peng에 의하여 발표된 크로스벡터 이론의 대비를 통하여 3상 4선 계통에서 순시전력보상방법을 분석한다. 3상 3선 계통에서 영상성분 전압이 없는 경우 두 이론은 똑같다. 그렇지만 3상 4선 계통에서 영상성분 전압과 전류가 포함되는 경우, 두 이론은 순시무효전력과 순시유효전력을 달리 정의한다. 본 논문에서는 이론적 분석과 컴퓨터 시뮬레이션을 바탕으로 영상성분 전압과 영상성분 전류가 존재하는 3상 4선 계통에서 에너지 저장요소의 필요 없이 무효전력만의 보상을 통하여 계통의 중성선 전류를 완벽히 제거할 수 있는 순시전력보상방법을 제시한다.

3상 계통에서 전류/전압과 순시전력간의 맵핑이론 (The Mapping Theory between Current/Voltage and Instantaneous Powers in Three-phase Systems)

  • 김효성;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.228-232
    • /
    • 1997
  • The relation between instantaneous active/reactive powers and currents is defined by voltage mapping matrix in three-phase four-wire systems. Control strategies for an active filter without energy storage components are proposed on the basis of mapping matrices. It can compensate for the zero-sequence current, irrespectively of whether or not a zero-sequence voltage exists in a three-phase four-wire system.

  • PDF

FUNDAMENTAL RESEARCH OF A NOVEL 3/1 PHASE CONVERTER FOR ELECTRIFIED RAILROAD

  • Farshad, Siamak;Rongtai, Hao
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.955-960
    • /
    • 1998
  • Electrified railroads inject large amount of harmonics, negative sequence and reactive currents to electric supply systems. This paper introduces application of active filter as a 3/1 phase converter for electrified railroad. In this system active filter compensate harmonics, negative sequence and reactive currents and electric railroad and active filter together act as a balance three-phase load with power factor 1

  • PDF

Model Predictive Control of Circulating Current Suppression in Parallel-Connected Inverter-fed Motor Drive Systems

  • Kang, Shin-Won;Soh, Jae-Hwan;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1241-1250
    • /
    • 2018
  • Parallel three-phase voltage source inverters in a direct connection configuration are widely used to increase system power ratings. A zero-sequence circulating current can be generated according to the switching method; however, the zero-sequence circulating current not only distorts current, but also reduces the system reliability and efficiency. In this paper, a model predictive control scheme is proposed for parallel inverters to drive an interior permanent magnet synchronous motor with zero-sequence circulating current suppression. The voltage vector of the parallel inverters is derived to predict and control the torque and stator flux components. In addition, the zero-sequence circulating current is suppressed by designing the cost function without an additional current sensor and high-impedance inductor. Simulation and experimental results are presented to verify the proposed control scheme.

전기로용 다단 H-브릿지 STATCOM의 전류제어 (Current Control in Cascaded H-bridge STATCOM for Electric Arc Furnaces)

  • 권병기;정승기;김태형;김윤현
    • 전력전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.19-30
    • /
    • 2015
  • A static synchronous compensator (STATCOM) applied to rapidly changing, highly unbalanced loads such as electric arc furnaces (EAFs), requires both positive-sequence and negative-sequence current control, which indicates fast response characteristics and can be controlled independently. Furthermore, a delta-connected STATCOM with cascaded H-bridge configuration accompanying multiple separate DC-sides, should have high performance zero-sequence current control to suppress a phase-to-phase imbalance in DC-side voltages when compensating for unbalanced load. In this paper, actual EAF data is analyzed to reflect on the design of current controllers and a pioneering zero-sequence current controller with a superb transient performance is devised, which generates an imaginary -axis component from the presumed response of forwarded reference. Via simulation and experiments, the performance of the positive, negative, and zero-sequence current control of a cascaded H-bridge STATCOM for EAF is verified.

A Novel Fast Open-loop Phase Locking Scheme Based on Synchronous Reference Frame for Three-phase Non-ideal Power Grids

  • Xiong, Liansong;Zhuo, Fang;Wang, Feng;Liu, Xiaokang;Zhu, Minghua;Yi, Hao
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1513-1525
    • /
    • 2016
  • Rapid and accurate phase synchronization is critical for the reliable control of grid-tied inverters. However, the commonly used software phase-locked loop methods do not always satisfy the need for high-speed and accurate phase synchronization under severe grid imbalance conditions. To address this problem, this study develops a novel open-loop phase locking scheme based on a synchronous reference frame. The proposed scheme is characterized by remarkable response speed, high accuracy, and easy implementation. It comprises three functional cascaded blocks: fast orthogonal signal generation block, fast fundamental-frequency positive sequence component construction block, and fast phase calculation block. The developed virtual orthogonal signal generation method in the first block, which is characterized by noise immunity and high accuracy, can effectively avoid approximation errors and noise amplification in a wide range of sampling frequencies. In the second block, which is the foundation for achieving fast phase synchronization within 3 ms, the fundamental-frequency positive sequence components of unsymmetrical grid voltages can be achieved with the developed orthogonal signal construction strategy and the symmetrical component method. The real-time grid phase can be consequently obtained in the third block, which is free from self-tuning closed-loop control and thus improves the dynamic performance of the proposed scheme. The proposed scheme is adaptive to severe unsymmetrical grid voltages with sudden changes in magnitude, phase, and/or frequency. Moreover, this scheme is able to eliminate phase errors induced by harmonics and random noise. The validity and utility of the proposed scheme are verified by the experimental results.