• Title/Summary/Keyword: Phase sequence

Search Result 925, Processing Time 0.031 seconds

Fault Phase Selection Algorithm using Unit Vector of Sequence Voltages for Transmission Line Protection (대칭분 전압 단위 벡터를 이용한 송전선로 보호용 고장상 선택 알고리즘)

  • Lee, Myeong-Su;Lee, Jae-Gyu;Kim, Su-Nam;Yu, Seok-Gu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.9
    • /
    • pp.460-466
    • /
    • 2002
  • A reliable fault phase selection algorithm plays a very important role in transmission line protection, Particularly in Extra High Voltage (EHV) networks. The conventional fault phase selection algorithm used the phase difference between positive and negative sequence current excluding load current. But, it is difficult to pick out only fault current since we can not know when a fault occurs and select the fault phase in weak-infeed conditions that dominate zero-sequence current in phase current. The proposed algorithm can select the accurately fault phase using the sum of unit vectors which are calculated by positive-sequence voltage and negative-sequence voltage.

Zero Sequence Impedance of Yg-Yg Three Phase Core Type Transformer (Yg-Yg 3상 내철형 변압기의 영상분 임피던스 분석)

  • Jo, Hyunsik;Cho, Sungwoo;Shin, Changhoon;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.940-945
    • /
    • 2016
  • In this paper, zero sequence equivalent circuit of Yg-Yg three phase core-type transformer is analyzed. Many problems by iron core structure of the three phase transformer due to asymmetric three phase lines, which includes line disconnection, ground fault, COS OFF, and unbalanced load are reported in the distribution system. To verify a feasibility of zero sequence impedance of Yg-Yg type three phase transformer, fault current generation in the three phase core and shell-type Yg-Yg transformer is compared by PSCAD/EMTDC when single line ground fault is occurred. As a result, shell-type transformer does not affect the flow of fault current, but core-type transformer generate an adverse effect by the zero sequence impedance. The adverse effect is explained by the zero sequence equivalent circuit of core-type transformer and Yg-Yg type three phase core-type transformer supplies a zero sequence fault current to the distribution system.

Phase Offset Enumeration Method with Error Detection and Its Application to Synchronization of PN Sequences

  • Song Young-Joan
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.1
    • /
    • pp.26-30
    • /
    • 2005
  • It is important to know phase offsets of PN(Pseudo Noise) sequences in spread spectrum communications since the acquisition is equivalent to making a phase offset between a receiving PN sequence and a PN sequence of local PN generator be identical. In this paper, a phase offset enumeration method for PN sequences with error detection, and its application to the synchronization are proposed. The phase offset enumeration for an n-tuple PN sequence and its error detection are performed when one period of the sequence is received. Once the phase offset of the receiving sequence is calculated, we can easily accomplish the synchronization by initializing shift registers of a local PN generator according to the phase offset value. The mean acquisition time performance of the proposed scheme was derived analytically. Since this synchronization scheme can be realized by using simple circuit and acquires very rapid acquisition in high SNR but shows performance degradation in low SNR, it can be especially useful in indoor and office environments.

The Analysis of Zero Sequence Components in Dynamic Voltage Restorer System (영상성분을 고려한 DVR 기기 해석)

  • Jeong, Il-Yeop;Park, Sang-Yeong;Won, Dong-Jun;Mun, Seung-Il;Park, Jong-Geun;Han, Byeong-Mun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.4
    • /
    • pp.169-174
    • /
    • 2002
  • The magnitude and phase of the compensating voltage in Dynamic Voltage Restorer (DVR) system depend on the voltage sag in the phases affected by the fault and on the influence of the zero sequence components. If the delta connection of the transformer is used, the zero sequence components do not appear on the load side. But nowadays, Y connected transformers with grounded neutral, that is 3-phase 4-wire system, are usually used. Therefore the zero-sequence components are occurred during faults. The zero-sequence components result in the high insulation costs and the asymmetry of the phase and magnitude of the terminal voltages. In this paper 3 phase 4 wire distribution system and 3 phase 3 wire system are analyzed and characteristics of voltage sag are presented. And this paper proposes the method that can mitigate the zero-sequence under the unbalance faults causing voltage sage and phase angle iumps.

A Coherent Phase Sequence Detection Scheme for SLM-based OFDM Systems without Side Information (위상 신호에 대한 부가 정보가 없는 SLM 기반 OFDM 시스템을 위한 동기식 위상 신호 검출 방식)

  • Ryu, Chang Su;Joo, Jung Suk
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.6
    • /
    • pp.15-20
    • /
    • 2016
  • In this paper, we consider selective mapping (SLM) based OFDM systems without side information, where SLM is one of the promising peak-to-average power ratio (PAPR) reduction techniques due to its simplicity and no distortion in the transmitted signal. First, we construct a new phase sequence where a part of phase sequence is replaced by an orthogonal sequence. Based on the proposed phase sequence, we propose a new scheme for detecting coherently the index of the phase sequence used in transmitter without side information. Computer simulation shows that the proposed detection scheme performs well in SLM-based OFDM systems, and specifically outperforms the existing ones when channel variation is relatively small between sub-carriers used in phase sequence detection.

Power Assist Control for Walking Aid by HAL Based on Phase Sequence and EMG

  • Lee, Suwoong;Yoshiyuki Sankai
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.46.1-46
    • /
    • 2001
  • This paper describes a control method of hybrid power assistive system for lower body, HAL, with the techniques of Phase Sequence and the application of EMG. Our objective is to attain the power assist control of motion in the lower body effectively with these two methods. The Phase Sequence which performs basic motion controls of HAL is the method that a motion, the Task, is accomplished by dividing each motion into the unit named Phase and ...

  • PDF

Phase Selection Algorithm using Sequence Voltages for Transmission Line Protection (대칭분 전압을 이용한 송전선로 보호용 고장상 선택 알고리즘)

  • Lee, Myoung-Soo;Kim, Soo-Nam;Lee, Jae-Gyu;You, Seok-Ku
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.124-126
    • /
    • 2001
  • A reliable fault type identification (phase selection) plays a very important role in transmission line protection, particularly in Extra High Voltage(EHV) networks. The conventional fault type identification algorithm used the phase difference between positive and negative sequence current excluding load current. But, it is difficult to pick out only fault current since we can not know when a fault occurs and identify the fault type in weak-infeed conditions that dominate zero-sequence current in phase current. The proposed algorithm can identify the accurately fault type using the sum of unit vectors which are calculated by positive-sequence votage and negative-sequence voltage.

  • PDF

Analysis and Control of Instantaneous Voltage Compensator Using New Phase Angle Detection Method Synchronized by Positive Sequence of Unbalanced 3-Phase Source (3상 불평형 전원 시스템의 새로운 위상각 검출기법을 이용한 순간전압보상기의 해석 및 제어)

  • 이승요;고재석;목형수;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.275-284
    • /
    • 1999
  • Unbalanced source voltage in the 3-phase power system is decomposed into positive, negative and zero sequence c components. Also, assuming there is no neutral path in the system, the zero sequence component is not shown on the l load side. Therefore, in the unbalanced power system without neutral path. it is possible to provide balanced voltage to t the load side by compensating negative sequence component and also to regulate the voltage amplitude by controlling t the positive sequence component. In addition, the symmetrical components due to voltage unbalance can be effectively d detected on the synchronous reference frame by using dlongleftarrowq transformation. In this paper, an algorithm not only c compensating unbalanced source voltage by canceling the negative sequence component on the synchronous reference f frame but also maintaining load voltages constantly is proposed. Also a novel method for phase angle detection s synchronized by positive sequence component under unbalanced source voltage is suggested and this detected phase a angle is used for d-q transformation. The performances and characteristics of the proposed compensating system are a analyzed by simulation and verified through experimental results.

  • PDF

Optimum signal setting based on phase sequence and interval in an isolated intersection (교통신호의 페이스순서 및 페이스간격을 고려한 신호최적화)

  • 김경철;임강원
    • Journal of Korean Society of Transportation
    • /
    • v.14 no.2
    • /
    • pp.45-58
    • /
    • 1996
  • In a large signal intersection, it is the most important to set phase sequences and phase intervals of traffic signal in order to improve the efficiency of the capacity as well as safety. These setting allows to select the best sequence of signal phase among several alternatives, and thus to rearrange the starting and ending points of the individual phase using an effective interphase periods (EIP). The EIP is a gap between previous and current traffic movements at a potential collision point in an intersection. Each of traffic movements has an equality for safety and efficiency at the balanced condition of EIP. This paper presents how to set optimally the phase sequences and intervals of traffic signal in an intersection using phase based approach. And in the second part, we applied the theory developed in the first part. In particular, a numerical example of phase base signal setting is presented using a matrix computation method in order to select the best sequence among several alternatives, and thus to rearrange the starting and ending points of the individual phase using the EIP. This method also allows to apply to optimum signal setting even in five-lag or staggered-type intersection.

  • PDF

Analysis of Shrinking Generator Using Phase Shifts (위상이동차를 이용한 수축 생성기의 분석)

  • Hwang, Yoon-Hee;Cho, Sung-Jin;Choi, Un-Sook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.11
    • /
    • pp.2507-2513
    • /
    • 2010
  • In this paper, we show that the shrinking generator with two LFSR whose characteristic polynomials are primitive is an interleaving generator and analyze phase shifts in shrunken sequence. Also for a given intercepted sequence of shrunken sequence, we propose. the method of reconstructing some deterministic bits of the shrunken sequence using phase shifts.