Effectiveness of the Respiratory Gating System for Stereotectic Radiosurgery of Lung Cancer (폐암 환자의 정위적 방사선 수술 시 Respiratory Gating System의 유용성에 대한 연구)

  • Song Heung-Kwon;Kwon Kyung-Tae;Park Cheol-Su;Yang Oh-Nam;Kim Min-Su;Kim Jeong-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.125-131
    • /
    • 2005
  • Purpose : For stereotactic radiosurgery (SRS) of a tumor in the region whose movement due to respiration is significant, like Lung lower lobe, the gated therapy, which delivers radiation dose to the selected respiratory phases when tumor motion is small, was performed using the Respiratory gating system and its clinical effectiveness was evaluated. Materials and Methods : For two SRS patients with a tumor in Lung lower lobe, a marker block (infrared reflector) was attached on the abdomen. While patient' respiratory cycle was monitored with Real-time Position Management (RPM, Varian, USA), 4D CT was performed (10 phases per a cycle). Phases in which tumor motion did not change rapidly were decided as treatment phases. The treatment volume was contoured on the CT images for selected treatment phases using maximum intensity projection (MIP) method. In order to verify setup reproducibility and positional variation, 4D CT was repeated. Results : Gross tumor volume (GTV) showed maximum movement in superior-inferior direction. For patient #1, motion of GTV was reduced to 2.6 mm in treatment phases ($30{\sim}60%$), while that was 9.4 mm in full phases ($0{\sim}90%$) and for patient #2, it was reduced to 2.3 mm in treatment phases ($30{\sim}70%$), while it was 11.7 mm in full phases ($0{\sim}90%$). When comparing two sets of CT images, setup errors in all the directions were within 3 mm. Conclusion : Since tumor motion was reduced less than 5 mm, the Respiratory gating system for SRS of Lung lower lobe is useful.

  • PDF

Study on the Morphology of the PC/ABS Blend by High Shear Rate Processing (PC/ABS 블렌드의 고속전단성형에 따른 모폴로지 변화에 관한 연구)

  • Lee, Dong Uk;Yong, Da Kyoung;Lee, Han Ki;Choi, Seok Jin;Yoo, Jae Jung;Lee, Hyung Il;Kim, Seon-Hong;Lee, Kee Yoon;Lee, Seung Goo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.3
    • /
    • pp.382-387
    • /
    • 2014
  • The PC/ABS blends were manufactured with high shear rate processing. Changes of the blend morphology were analyzed according to the screw speed and processing time. To find optimal conditions of the high shear rate processing of the PC/ABS blend, blend morphology and size of the dispersed phase, ABS, were observed with a SEM. Also, tensile properties of the PC/ABS blends were measured to investigate the effect of the high shear rate process with the screw speed of 500 rpm to 3000 rpm for processing times of 10s to 40s. Especially, to observe the dispersed phase of the PC/ABS blend clearly, fracture surfaces of the PC/ABS blend were etched with chromic acid solution. As screw speed and processing time increase, dispersed phase size of the PC/ABS blend decreases and mechanical properties of the blend decrease as well. Especially, at screw speed over than 1000 rpm of high shear rate processing, mechanical properties of the PC/ABS blends decrease drastically due to the degradation of the blend during the high shear rate processing. Consequently, the optimal condition of screw speed of the high shear processing of the PC/ABS blend is set at 1000rpm, in this study. Under optimal condition, the PC/ABS blend has relatively high mechanical properties with the relatively stable micro-structure having nanometer scale dispersed phase.

Multiple Linear Analysis for Generating Parametric Images of Irreversible Radiotracer (비가역 방사성추적자 파라메터 영상을 위한 다중선형분석법)

  • Kim, Su-Jin;Lee, Jae-Sung;Lee, Won-Woo;Kim, Yu-Kyeong;Jang, Sung-June;Son, Kyu-Ri;Kim, Hyo-Cheol;Chung, Jin-Wook;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.317-325
    • /
    • 2007
  • Purpose: Biological parameters can be quantified using dynamic PET data with compartment modeling and Nonlinear Least Square (NLS) estimation. However, the generation of parametric images using the NLS is not appropriate because of the initial value problem and excessive computation time. In irreversible model, Patlak graphical analysis (PGA) has been commonly used as an alternative to the NLS method. In PGA, however, the start time ($t^*$, time where linear phase starts) has to be determined. In this study, we suggest a new Multiple Linear Analysis for irreversible radiotracer (MLAIR) to estimate fluoride bone influx rate (Ki). Methods: $[^{18}F]Fluoride$ dynamic PET scans was acquired for 60 min in three normal mini-pigs. The plasma input curve was derived using blood sampling from the femoral artery. Tissue time-activity curves were measured by drawing region of interests (ROls) on the femur head, vertebra, and muscle. Parametric images of Ki were generated using MLAIR and PGA methods. Result: In ROI analysis, estimated Ki values using MLAIR and PGA method was slightly higher than those of NLS, but the results of MLAIR and PGA were equivalent. Patlak slopes (Ki) were changed with different $t^*$ in low uptake region. Compared with PGA, the quality of parametric image was considerably improved using new method. Conclusion: The results showed that the MLAIR was efficient and robust method for the generation of Ki parametric image from $[^{18}F]Fluoride$ PET. It will be also a good alternative to PGA for the radiotracers with irreversible three compartment model.

Characteristics of the Electro-Optical Camera(EOC) (다목적실용위성탑재 전자광학카메라(EOC)의 성능 특성)

  • Seunghoon Lee;Hyung-Sik Shim;Hong-Yul Paik
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.3
    • /
    • pp.213-222
    • /
    • 1998
  • Electro-Optical Camera(EOC) is the main payload of the KOrea Multi-Purpose SATellite(KOMPSAT) with the mission of cartography to build up a digital map of Korean territory including a Digital Terrain Elevation Map(DTEM). This instalment which comprises EOC Sensor Assembly and EOC Electronics Assembly produces the panchromatic images of 6.6 m GSD with a swath wider than 17 km by push-broom scanning and spacecraft body pointing in a visible range of wavelength, 510~730 nm. The high resolution panchromatic image is to be collected for 2 minutes during 98 minutes of orbit cycle covering about 800 km along ground track, over the mission lifetime of 3 years with the functions of programmable gain/offset and on-board image data storage. The image of 8 bit digitization, which is collected by a full reflective type F8.3 triplet without obscuration, is to be transmitted to Ground Station at a rate less than 25 Mbps. EOC was elaborated to have the performance which meets or surpasses its requirements of design phase. The spectral response, the modulation transfer function, and the uniformity of all the 2592 pixel of CCD of EOC are illustrated as they were measured for the convenience of end-user. The spectral response was measured with respect to each gain setup of EOC and this is expected to give the capability of generating more accurate panchromatic image to the users of EOC data. The modulation transfer function of EOC was measured as greater than 16 % at Nyquist frequency over the entire field of view, which exceeds its requirement of larger than 10 %. The uniformity that shows the relative response of each pixel of CCD was measured at every pixel of the Focal Plane Array of EOC and is illustrated for the data processing.

Study of Surface Reaction and Gas Phase Chemistries in High Density C4F8/O2/Ar and C4F8/O2/Ar/CH2F2 Plasma for Contact Hole Etching

  • Kim, Gwan-Ha
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.2
    • /
    • pp.90-94
    • /
    • 2015
  • In this study, the characterizations of oxide contact hole etching are investigated with C4F8/O2/Ar and CH2F2/C4F8/O2/ Ar plasma. As the percent composition of C4F8 in a C4F8/O2/Ar mixture increases, the amount of polymer deposited on the etched surface also increases because the CxFy polymer layer retards the reaction of oxygen atoms with PR. Adding CH2F2 into the C4F8/O2/Ar plasma increases the etch rate of the oxide and the selectivity of oxide to PR. The profile of contact holes was close to 90°, and no visible residue was seen in the SEM image at a C4F8/(C4F8+O2) ratio of 58%. The changes of chemical composition in the chamber were analyzed using optical emission spectroscopy, and the chemical reaction on the etched surface was investigated using X-ray photoelectron spectroscopy.

Experimental Study on Behavior of Green Water for Rectangular Structure (사각형 해양구조물의 청수현상 발생과정에 대한 실험적 연구)

  • Chae, Young Jun;Lee, Kang Nam;Jung, Kwang Hyo;Suh, Sung Bu;Lee, Jae Yong
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.44-50
    • /
    • 2016
  • An experimental study was performed to investigate the behavior of green water on a structure with a rectangular cross section under wave conditions, along with the flow characteristics in bubbly water flow. An experiment was conducted in a two-dimensional wave flume using an acrylic model (1/125) of FPSO BW Pioneer operating in the Gulf of Mexico under its design wave condition. The occurrence of green water, including its development, in front of the model was captured using a high-speed Charge Coupled Device (CCD) camera with the shadowgraph technique. Using consecutive images, the generation procedure for green water on the model was divided into five phases: flip through, air entrapment, wave run-up, wave overturning, and water shipping. In addition, the distinct water elevations of the green water were defined as the height of flip through, height of splashing jet, and height of freeboard exceedance, and showed a linear relationship with the incoming wave height.

Ultrasonographic Analysis of the Size and Shape of the Muscles (근육의 크기와 형태의 초음파적 분석)

  • Kim, Kwang-Baek
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.2
    • /
    • pp.9-15
    • /
    • 2011
  • In this paper, we propose a method to extract the external oblique muscle of abdomen images that is often excluded by previous method due to image distortion. In the preprocessing phase of the proposed method, we emphasize the brightness contrast with Ends-in search stretching algorithm after removing noise from the initial ultrasonic images. Then we apply average binarization in vertical direction to extract candidate fascia areas. After removing other areas than fascia with morphological characteristics, the lost part in the fascia during the process is restored with such characteristic information and location information. Then the skin area is also removed with information from the arc appearing in convex filming and the candidate muscle areas are extracted by overlapping two results two way up-down search algorithm. Another noise removing process is done to determine the muscle area. In case of obtaining obscure result, after restoring the muscle area by smearing method, the thickness of the muscle is measured by min square method. The experiment verifies that the proposed method is sufficiently effective to analyze the size and shape of muscles in abdomen in ultrasonography than previously used methods.

A Study on the Muscovite-Pyrophyllite Mixed Phase in the Shale from the Manhang Formation, Taebaek Area (태백지역 만항층 셰일에서 산출되는 백운모-파이로필라이트 혼합상에 대한 연구)

  • Choi, Seung-Hyun;Mun, Hyang-Ran;Lee, Young-Boo;Lee, Jung-Hoo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.313-320
    • /
    • 2011
  • Mica-type phyllosilicate particles in the shales of the Manhang formation at the Taeback area in the Kangwon Province were studied using electron probe microanalysis (EPMA) and transmission electron microscopy (TEM). The average chemical formula of the mica-type phyllosilicate mineral analysed by EPMA is $K_{1.35}(Fe_{0.18}Mg_{0.03}Al_{3.86})(Si_{6.55}Al_{1.45})O_{20}(OH)_4$. Low K contents compared to the ideal chemistry of muscovite indicate the presence of illite in the mica-type phyllosilicate particle. X-ray diffraction study showed that pyrophyllite commonly coexists with muscovite in the shales from the Manhang Formation. TEM observations showed both the interlayer and intralayer mixing of $9.3-{\AA}$ pyrophyllite and $10-{\AA}$ muscovite layers. The low K content of the mica-type phyllosilicates apparently come from the close mixing of pyrophyllite and muscovite.

The 3D Depth Extraction Method by Edge Information Analysis in Extended Depth of Focus Algorithm (확장된 피사계 심도 알고리즘에서 엣지 정보 분석에 의한 3차원 깊이 정보 추출 방법)

  • Kang, Sunwoo;Kim, Joon Seek;Joo, Hyonam
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.2
    • /
    • pp.139-146
    • /
    • 2016
  • Recently, popularity of 3D technology has been growing significantly and it has many application parts in the various fields of industry. In order to overcome the limitations of 2D machine vision technologies based on 2D image, we need the 3D measurement technologies. There are many 3D measurement methods as such scanning probe microscope, phase shifting interferometry, confocal scanning microscope, white-light scanning interferometry, and so on. In this paper, we have used the extended depth of focus (EDF) algorithm among 3D measurement methods. The EDF algorithm is the method which extracts the 3D information from 2D images acquired by short range depth camera. In this paper, we propose the EDF algorithm using the edge informations of images and the average values of all pixel on z-axis to improve the performance of conventional method. To verify the performance of the proposed method, we use the various synthetic images made by point spread function(PSF) algorithm. We can correctly make a comparison between the performance of proposed method and conventional one because the depth information of these synthetic images was known. Through the experimental results, the PSNR of the proposed algorithm was improved about 1 ~ 30 dB than conventional method.

Effect of Walk Training on Physical Fitness for Prevention in A home Bound Elderly (걷기 훈련이 재택 노인의 낙상방지 체력에 미치는 영향)

  • Choe, Myeong-Ae;Jeon, Mi-Yang;Choe, Jeong-An
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.5
    • /
    • pp.1318-1332
    • /
    • 2000
  • The purpose of this study was to determine the effect of walk training on leg strength, flexibility, postural stability, balance and gait in home bound elderly women. Eighteen elderly women of the experimental group aged between 70 and 90 years image who have normal vision, hearing and Romberg test. They participated in the 12 week walk training. The subjects of the experimental group practiced walk training 3 times a week for during 12 weeks. During the 40 minute workout, the subjects practiced 5 minutes of warming-up exercises, 30 minutes of conditioning exercises and 10 minutes of a cool-down exercise. The intensity for the conditioning phase was determined by subject' heart rates, which ranged from 60% to 70% of age-adjusted maximum heart rates. The body composition, leg strength, flexibility, postural stability, balance and gait were measured prior to and after the experimental treatment. The body fat, lean body mass, leg strength (ankle dorsiflexor, plantarflexor, inversor and eversir, knee flexor, extensior), flexibility (range of motion of ankle dorsiflexion, plantarflexion, inversion and eversion), and postural stability of the experimental group were significantly greater than those of the control group. Duration of standing on the right foot and that of standing on the left foot of the experimental group was greater than that of the control group. Total balance scores of the experimental group were significantly higher than those of the control group. Among 13 items for balance, the scores of experimental group in balance with eyes closes, turning balance, sternal nudge, neck turning, one leg standing balance and back extension were higher than those of the control group. Total scores of gait of the experimental group were significantly higher than those of the control group following the walking training. Scores of experimental group in step height, step length and walk stance while walking among 9 items for gait were significantly higher than those of the control group. The results suggest that walk training can improve physical fitness for prevention in home bound elderly women.

  • PDF