• 제목/요약/키워드: Phase Difference

검색결과 3,099건 처리시간 0.033초

Measurement of electron density of atmospheric pressure Ar plasma jet by using Michelson interferometer

  • Lim, Jun-Sup;Hong, Young June;Choi, Eun Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.195.1-195.1
    • /
    • 2016
  • Currently, as Plasma application is expanded to the industrial and medical industrial, low temperature plasma applications became important. Especially in medical and biology, many researchers have studied about generated radical species in atmospheric pressure low temperature plasma directly adapted to human body. Therefore, so measurement their plasma parameter is very important work and is widely studied all around world. One of the plasma parameters is electron density and it is closely relative to radical production through the plasma source. some kinds of method to measuring the electron density are Thomson scattering spectroscopy and Millimeter-wave transmission measurement. But most methods have very expensive cost and complex configuration to composed of experiment system. We selected Michelson interferometer system which is very cheap and simple to setting up, so we tried to measuring electron density by laser interferometer with laser beam chopping module for measurement of temporal phase difference in plasma jet. To measuring electron density at atmospheric pressure Ar plasma jet, we obtained the temporal phase shift signal of interferometer. Phase difference of interferometer can occur because of change by refractive index of electron density in plasma jet. The electron density was able to estimate with this phase difference values by using physical formula about refractive index change of external electromagnetic wave in plasma. Our guiding laser used Helium-Neon laser of the centered wavelength of 632 nm. We installed chopper module which can make a 4kHz pulse laser signal at the laser front side. In this experiment, we obtained more exact synchronized phase difference between with and without plasma jet than reported data at last year. Especially, we found the phase difference between time range of discharge current. Electron density is changed from Townsend discharge's electron bombardment, so we observed the phase difference phenomenon and calculated the temporal electron density by using phase shift. In our result, we suggest that the electron density have approximately range between 1014~ 1015 cm-3 in atmospheric pressure Ar plasma jet.

  • PDF

기본교란 및 분수조화교란을 이용한 원형제트에서의 보텍스병합 (Vortex pairing in an axisymmetric jet using fundamental and subharmonic forcing)

  • 조성권;유정열;최해천
    • 대한기계학회논문집B
    • /
    • 제21권10호
    • /
    • pp.1350-1362
    • /
    • 1997
  • An experimental study has been performed on vortex pairing under fundamental and subharmonic forcing with controlled initial phase differences through hot-wire measurements and a multi-smoke wire flow visualization. For the range of St$_{D}$ < 0.6, vortex pairing was controlled by means of fundamental and subharmonic forcing with varying initial phase differences. Much larger mixing rate was achieved by two-frequency forcing with a proper phase difference than one frequency forcing. As St$_{D}$ decreased, vortex pairing was limited to a narrow region of the initial phase difference between two disturbances and higher amplitudes of the fundamental and its subharmonic at the nozzle exit were required for more stable pairing. As the amplitude of the subharmonic at the nozzle exit increased for fixed St$_{D}$ and fundamental amplitude, the distribution of the subharmonic mode against the variation of the initial phase difference changed from a sine function form into a cusp-like form. Thus, vortex pairing can be controlled more precisely for the former case. For St$_{D}$ > 0.6, non-pairing advection of vortices due to the improper phase difference was sometimes observed in several fundamental forcing amplitudes when only the fundamental was applied. However, when its subharmonic was added, vortex pairing readily occurred. As the initial amplitude of this subharmonic increased, the position of vortex pairing moved upstream. This was thought to be due to the fact that the variation of the initial phase difference between the fundamental and its subharmonic has less effects on vortex pairing in the region of fundamental-only vortex pairing.pairing.

유성기어 소음저감을 위한 캐리어 위상차 설계에 관한 연구 (A Study on the Design of the Carrier Phase Difference for the Planetary Gear Noise Reduction)

  • 박기호;김태훈;정상진;위혁;이국선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.230-231
    • /
    • 2011
  • There is a merit a planetary gear set disperses a delivery load, and to decrease loss of friction and noise. But, in addition to meshing this internal and external gear simultaneously and phase difference by the tooth contact point and the time difference occurs asymmetric and symmetric sideband noise and vibration caused by the modulation in the vehicle. Existing planetary gear set research have progressed to reduce the cause of the sideband as run-out, pitch error and imbalance. In this paper presents a method for the design of the carrier phase difference by developing various theorys and experiments for gear noise.

  • PDF

Analysis of Phase Error Effects Due to Grid Frequency Variation of SRF-PLL Based on APF

  • Seong, Ui-Seok;Hwang, Seon-Hwan
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.18-26
    • /
    • 2016
  • This paper proposes a compensation algorithm for reducing a specific ripple component on synchronous reference frame phase locked loop (SRF-PLL) in grid-tied single-phase inverters. In general, SRF-PLL, which is based on all-pass filter to generate virtual voltage, is widely used to estimate the grid phase angle in a single-phase system. In reality, the estimated grid phase angle might be distorted because the phase difference between actual and virtual voltages is not 90 degrees. That is, the phase error is caused by the difference between cut-off frequency of all-pass filter and grid frequency under grid frequency variation. Therefore, the effects on phase angle and output current attributed to the phase error are mathematically analyzed in this paper. In addition, the proportional resonant (PR) controller is adapted to reduce the effects of phase error. The validity of the proposed algorithm is verified through several simulations and experiments.

교류 AT급전방식에서 병렬급전시 변전소간 전압위상차에 의한 루프전류에 관한 연구 (A Study on the Loop Current Induced by Voltage Phase Difference Substations during Parallel Feeding under the Alternating Current AT Electric Power Feeding Method)

  • 박재석;송중호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1997-2004
    • /
    • 2011
  • The $2{\times}25kv$ AT electric power feeding method in the A.C. electric train adopts the one-phase power feeding method as the standard due to a voltage phase difference, and the distance between the two neighboring substations is 50km due to voltage drop. The one-phase power feeding method makes the system operation feasible, while making it unfavorable for power supply. Moreover, railroad involves large-capacity single-phase load, and if it is expected to continue to rise, it is necessary to research on measures to stabilize the supply of power to railroad cars with the existing facilities. In this study, a parallel power feeding method between neighboring substations is proposed to stabilize the supply of electric power to electric railroad cars under the 2*25kv AT power feeding method and the loop current induced by voltage phase difference between the two neighboring substations during parallel power feeding is investigated.

  • PDF

A Preconditioning Method for Two-Phase Flows with Cavitation

  • Shin B.R.;Yamamoto S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 The Fifth Asian Computational Fluid Dynamics Conference
    • /
    • pp.181-182
    • /
    • 2003
  • A preconditioned numerical method for gas-liquid to-phase flow is applied to solve cavitating flow. The present method employs a density based finite-difference method of dual time-stepping integration procedure and Roe's flux difference splitting approximation with MUSCL-TVD scheme. A homogeneous equilibrium cavitation model is used. The method permits simple treatment of the whole gas-liquid two-phase flow field including wave propagation, large density changes and incompressible flow characteristics at low Mach number. By this method, two-dimensional internal flows through a venturi tuve and decelerating cascades are computed and discussed.

  • PDF

편마비 환자의 계단과 경사로 보행 동안 하지의 운동학적 분석 (Kinematic Analysis of Lower Extremities during Staris and Ramp Walking with Hemiplegic Patients)

  • 천동환
    • The Journal of Korean Physical Therapy
    • /
    • 제25권5호
    • /
    • pp.297-302
    • /
    • 2013
  • Purpose: This study was conducted in order to investigate the kinematic gait parameter of lower extremities with different gait conditions (level walking, stair, ramp) in hemiplegic patients. Methods: Ten hemiplegic patients participated in this study and kinematic data were measured using a 3D motion analysis system (LUKOtronic AS202, Lutz-kovacs-Electronics, Innsbruk, Austria). Statistical analysis was performed using one-way repeated measure of ANOVA in order to determine the difference of lower extremity angle at each gait phase with different gait conditions. Results: Affected degree of ankle joint in the heel strike phase showed significant difference between level walking and climbing stairs, and toe off phase showed significant difference between level walking and climbing stairs, ramps, and climbing stairs. Affected degree of knee joint showed no significant difference in all attempts. Affected degree of hip joint in the toe off phase showed significant difference between level walking, ramps and stairs, and climbing ramps. Swing phase showed significant difference between sides for level walking and stairs, climbing ramps. Affected ankle joint of heel strike and toe off, and affected hip joint of toe off and the maximum angle of swing phase in the angle was increased. Unaffected side of the ankle joint, knee joint, and hip joint showed a significant increase in walking phase. Conclusion: These findings indicate that compared with level walking, different results were obtained for joint angle of lower extremity when climbing stairs and ramps. In hemiplegia patient's climbing ramps, stairs, more movement was observed not only for the non-affected side but also the ankle joint of the affected side and hip joint. According to these findings of hemiplegic patients when climbing stairs or ramps, more joint motion was observed not only on the unaffected side but also on the affected side compared with flat walking.

전압차 제어에 의한 초음파 모터의 속도 및 토오크 특성 (Speed and Torque characteristics of Ultrasonic Motor by Voltage difference control)

  • 김영동;오금곤
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제10권6호
    • /
    • pp.88-95
    • /
    • 1996
  • 초음파 모터(ultrasonic motor : USM)는 압전 세라믹소자(piezoelectric ceramics)의 초음파 진동을 이용한 마찰 구동형 모터이다. 기존의 전자식 모터와는 달리 자기화로 즉 철심과 코일이 없는 단순 구조를 갖는 특수 소형 모터로서 저속 고토오크의 특성을 지니고 있으므로 다이랙트 드라이브 방식의 액츄에이터로 활용이 가능하다. 그리고 자장이 강한 특수 환경에서도 외란의 영향을 받지 않아도 산업계 전바에 걸쳐 제어용 모터로서 높이 평가받고 있다. 따라서 실용화를 위한 여러 가지 파라미터에 대한 특성 실험과 그에 따른 제어법 개발이 시급하다. 본 논문에서는 2상 입력 전원의 전압차 제어(voltags)를 제안한다. 먼저 전압차 제어에 의하여 이론적으로 고찰하고 초음파 모터의 구동원이 되는 고정자의 한 질점에서 발생하는 타원 궤적을 시뮬레이션을 통하여 알아봄으로써 초음파 모터의 속도와 토오크 특성을 예측하였다. 그리고 입력 전압워 전압차를 조절하여 초음파 모터의 속도와 토오트 특성을 실험하였다. 그 결과를 토대로 전압차 제어가 초음파 모터의 새로운 구동 방식이 될 수 있음을 밝혔다.

  • PDF

헬리컬 기본교란과 축대칭 분수조화교란을 이용한 원형제트에서의 보텍스 병합 및 제트확산 (Vortex Pairing and Jet-Spreading in an Axisymmetric Jet under Helical Fundamental and Axisymmetric Subharmonic Forcing)

  • 조성권;유정열;최해천
    • 대한기계학회논문집B
    • /
    • 제22권11호
    • /
    • pp.1610-1624
    • /
    • 1998
  • An axisymmetric jet is forced with two helical fundamental waves of identical frequency spinning in opposite directions and an additional axisymmetric sub harmonic wave. The subharmonic component rapidly grows downstream from subharmonic resonance with the fundamental, significantly depending on the initial phase difference. The variations of the subharmonic amplitude with the initial phase difference show cusp-like shapes. The amplification of the sub harmonic results in 'vortex pairing of helical modes'. Furthermore, azimuthal variation of the amplification induces an asymmetric jet cross-section. When the initial subharmonics is imposed with an initial phase difference close to a critical value, the jet-cross section evolves into a three-lobed shape. One lobe is generated by the enhanced vortex pairing and the other two lobes are generated by the delayed vortex pairing. Thus, it is confirmed that the initial phase difference between the fundamental and the subharmonic plays an important role in controlling the jet cross-section.

요통에 따른 프로 골퍼의 드라이버 스윙에 관한 근전도 분석 (The Effect of Low Back Pain on the EMG of Professional Golfer's Drive Swing)

  • 박종율
    • 한국운동역학회지
    • /
    • 제15권4호
    • /
    • pp.67-74
    • /
    • 2005
  • The purpose of this study is to compare and analyze the muscle activations between the professional golfers without low back pain symptom and the professional golfers with low back pain symptom, and so identify the stress related to golf swings, and provide the basic data to minimize the low back pain and the injury risk. Using surface electrode electromyography, we evaluated muscle activity in 6 male professional golfers during the golf drive swing. Surface electrodes were used to record the level of muscle activity in the Abdominal Oblique, Elector Spinae, Rectus Abdominis, Gluteus Maximus muscles during the golfer's swing. These signals were compared with %RVC(Reference voluntary contraction) which was normalized by IEMG(Integrated EMG). The golf swing was divided into five phases: take away, forward swing, acceleration, early follow through, late follow through. we observed patterns of trunk muscle activity throughout five phases of the golf swing. The results can be summarized as follows: RES(Right Elector Spinae) had statistically significant difference in take away phase, LGM(Left Gluteus Maximus), LRA(Left Rectus Abdominis), LOA(Left Oblique Abdominal) had statistically significant difference in forward swing phase, RES(Right Elector Spinae), RGM(Right Gluteus Maximus), ROA(Right Oblique Abdominal) had statistically significant difference in acceleration phase, RES(Right Elector Spinae), RGM(Right Gluteus Maximus) had statistically significant difference in early follow-through phase, LES(Left Elector Spinae), RGM(Right Gluteus Maximus) had statistically significant difference in late follow through phase.